252.204-7001 BE FURNISHED
SECTION A - COVER SHEET
(See Section L of the Table of Contents in
You are cautioned to note the "Certification of Non-Segregated Facilities" in the solicitation. Failure to agree to the certification will render your reply nonresponsive to the terms of solicitations involving awards of contracts exceeding $25,000 which are not exempt from the provisions of the Equal Opportunity clause.
"Fill-ins" are provided on the face and reverse of Standard Form 18 and Parts I and IV of Standard Form 33, or other solicitation documents and Sections of Table of Contents in this solicitation and should be examined for applicability.
See the provision of this solicitation entitled "Late Bids, Modifications of Bids or Withdrawal of Bids" or "Late Proposals, Modifications of Proposals and Withdrawals of Proposals."
When submitting your reply,the envelope used must be plainly marked with the Solicitation Number, as shown above and the date and local time set forth for bid opening or receipt of proposals in the solicitation document.
If NO RESPONSE is to be submitted, detach this sheet from the solicitation, complete the information requested on reverse,fold, affix postage, and mail. NO ENVELOPE IS NECESSARY.
Replies must set forth full, accurate, and complete information as required by this solicitation The penalty for making false statements is prescribed in 18 U.S.C.1001.
(X one).
a. SEALED BID
c. NEGOTIATED (RFQ)
INSTRUCTIONS
NOTE THE AFFIRMATIVE ACTION REQUIREMENT OF THE EQUAL OPPORTUNITY CLAUSE WHICH MAY APPLY TO THE CONTRACT
RESULTING FROM THIS SOLICITATION.
3. ISSUING OFFICE
(including attachments).
4. ITEMS TO BE PURCHASED
5 PROCUREMENT INFORMATION
a. THIS PROCUREMENT IS UNRESTRICTED
b. THIS PROCUREMENT IS A ______% SET-ASIDE FOR ONE OF THE FOLLOWING
1. SOLICITATION NUMBER
INFORMATION TO OFFERORS OR QUOTERS
6. ADDITIONAL INFORMATION
(1) Small Business (2) Labor Surplus Area Concerns (3) Combined Small Business/Labor Area Concerns
DD Form 1707, MAR 89 Previous editions are obsolete.
(Brief description)
(Complete mailing address, including Zip Code)
(X one) this solicitation for details of the set-aside.)
(X and complete as applicable)
461/089
2.
b. NEGOTIATED (RFP)
7. POINT OF CONTACT FOR INFORMATION
a. NAME (Last, First, Middle Initial) b. ADDRESS (Include Zip Code)
c. TELEPHONE NUMBER (Include Area Code and Extension) (NO COLLECT CALLS)
NOTE : IT IS REQUESTED THAT THE INFORMATION REQUIRED BY CLAUSES 52.204-4 AND
NOTE THE CLAUSE 52.232-25 ENTITLED "PROMPT PAYMENT" IN THE SOLICITATION.
NOTE : IT IS THE POLICY OF THE DOD TO MAXIMIZE THE NUMBER OF SMALL AND
DISADVANTAGED (SDB) CONCERNS PARTICIPATING IN DEFENSE PRIME AND SUBCONTRACTS.
IT IS REQUIRED THAT PRIME CONTRACTORS' SUBCONTRACT PLANS, WHEN REQUIRED
BY THE SOLICITATION, REFLECT A SDB GOAL OF 5% OR GREATER .
N00104-19-R-FB71
X
18228-0216 (TRIPER )
NAVSUP WEAPON SYSTEMS SUPPORT MECH
5450 CARLISLE PIKE
P O BOX 2020
MECHANICSBURG PA 17055-0788
SEE SCHEDULE
* THIS PROCUREMENT IS 100% SET-ASIDE FOR SMALL BUSINESSES
R. HOFFMAN N743.32
NAVSUP WEAPON SYSTEMS SUPPORT MECH
(717) 605-4048 MECHANICSBURG PA 17055-0788
KKKKKKKKKKKKKKKKKKKJ
KKKKKKKKKKKKKKKKKKKJ
e. OTHER
8. REASONS FOR NO RESPONSE
DD Form 1707 Reverse, MAR 89
(1) Typed or Printed Name
d. DO NOT REGULARLY MANUFACTURE OR SELL THE TYPE OF ITEMS INVOLVED
b. CANNOT MEET DELIVERY REQUIREMENT
c. UNABLE TO IDENTIFY THE ITEM(S)
a. CANNOT COMPLY WITH SPECIFICATIONS
9. MAILING LIST INFORMATION
WE DESIRE TO BE RETAINED ON THE MAILING LIST FOR FUTURE PROCUREMENT OF THE TYPE OF ITEM(S) INVOLVEDYES NO
10. RESPONDING FIRM
a. COMPANY NAME b. ADDRESS
c. ACTION OFFICER
(4) Date Signed
AFFIX
STAMP
HERE
(X all that apply)
FROM
DATE (YYMMDD)
SOLICITATION NUMBER
LOCAL TIME TO
(Last, First, Middle Initial) (YYMMDD)
(2) Title (3) Signature
FOLDFOLD
FOLD FOLD
(Specify)
(X one)
(INCLUDE ZIP CODE)
N00104-19-R-FB71
2019 MAR 11 02:30 P.M.
or if handcarried, in the depository located in until local time (Date)
9. Sealed offers in original and copies for furnishing the supplies or services in the Schedule will be received at the place specified in Item 8, IV
III
III
INSTRS., CONDS., AND NOTICES TO OFFERORS
21. ACCOUNTING AND APPROPRIATION20. AMOUNT19. ACCEPTED AS TO ITEMS NUMBERED
SOLICITATION
M
M
M
Prescribed by GSA FAR (48 CFR) 53.214(c)
EVALUATION FACTORS FOR AWARD
REPRESENTATIONS, CERTIFICATIONS AND
OTHER STATEMENTS OF OFFERORS
LIST OF ATTACHMENTS
CONTRACT CLAUSES
M L
K
J
I
SEC. DESCRIPTION PAGE(S)
SPECIAL CONTRACT REQUIREMENTS
CONTRACT ADMINISTRATION DATA
DELIVERIES OR PERFORMANCE
INSPECTION AND ACCEPTANCE
H G F E D C B A
PACKAGING AND MARKING
DESCRIPTION/SPECS./WORK STATEMENT
SUPPLIES OR SERVICES AND PRICES/COSTS
SOLICITATION/CONTRACT FORM
14. ACKNOWLEDGMENT OF AMENDMENTS
opposite each item, delivered at the designated point(s), within the time specified in the schedule.
from the date for receipt of offers specified above, to furnish any or all items upon which prices are offered at the price set
(60 calendar days unless a different12. In compliance with the above, the undersigned agrees, if this offer is accepted within ______ calendar days
CODE
(Signature of Contracting Officer)
10. FOR INFORMATION
CALL:
(Type or print)
11. TABLE OF CONTENTS
33-132
(If other than Item 7)24. ADMINISTERED BY
CODE
STANDARD FORM 33
IMPORTANT - Award will be made on this Form, or on Standard Form 26, or by other authorized official written notice.
25. PAYMENT WILL BE MADE BY
(If other than Item 7)8. ADDRESS OFFER TO
NSN 7540-01-152-8064
PREVIOUS EDITION NOT USABLE
7. ISSUED BY
RATING PAGE OF
PAGESSOLICITATION, OFFER AND AWARD
2. CONTRACT NO. 5. DATE ISSUED 6. REQUISITION/PURCHASE NO.4. TYPE OF SOLICITATION
A. NAME B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)
15A. NAME
AND
ADDRESS
OF
OFFEROR
16. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN OFFER
(TYPE OR PRINT)
18. OFFER DATE17. SIGNATURE15B. TELEPHONE NO. (Include areacode) 15C. CHECK IF REMITTANCE ADDRESS
IS DIFFERENT FROM ABOVE - ENTER
SUCH ADDRESS IN SCHEDULE
27. UNITED STATES OF AMERICA 28. AWARD DATE
AWARD
(Hour)
NEGOTIATED (RFP)
CODE CODE
FACILITY
NOTE: Item 12 does not apply if the solicitation includes the provisions at 52.214-16, Minimum Bid Acceptance Period.
26. NAME OF CONTRACTING OFFICER
13. DISCOUNT FOR PROMPT PAYMENT
3. SOLICITATION NO.
period is inserted by the offeror)
(See Section I, Clause No. 52-232-8)
(The offeror acknowledges receipt of amendments to the SOLICITATION for offerors and related doc-uments numbered and dated:
10 CALENDAR DAYS 20 CALENDAR DAYS 30 CALENDAR DAYS CALENDAR DAYS
AMENDMENT NO. DATE AMENDMENT NO. DATE
SEC. PAGE(S)DESCRIPTION
(To be completed by Government)
1. THIS CONTRACT IS A RATED ORDER
UNDER DPAS (15 CFR 350)
SEALED BID (IFB)
NOTE: In sealed bid solicitations "offer" and "offeror": mean "bid" and "bidder".
CAUTION - LATE Submissions, Modifications, and Withdrawals: See Section L, Provision No. 52.214-7 or 52.215-10. All offers are subject to all terms and conditions contained in this solicitation.
(REV. 4-85)
22. AUTHORITY FOR USING OTHER THAN FULL AND OPEN COMPETITION:
M ITEM23. SUBMIT INVOICES TO ADDRESS SHOWN IN(4 copies unless otherwise specified)41 U.S.C. 253(c)( )10 U.S.C. 2304(c)( )
OFFER (Must be fully completed by offeror)
PART - THE SCHEDULE PART - CONTRACT CLAUSES
PART - LIST OF DOCUMENTS, EXHIBITS AND OTHER ATTACH.
PART - REPRESENTATIONS AND INSTRUCTIONS
DO-A3 1 84
N00104-19-R-FB71 X 2019 FEB 09 18228-0216 (TRIPER )
N00104
NAVSUP WEAPON SYSTEMS SUPPORT MECH
5450 CARLISLE PIKE
P O BOX 2020
MECHANICSBURG PA 17055-0788
BLDG.410, SOUTH END, CODE N7, BAY B-29 02:30PM 2019 MAR 11
R. HOFFMAN N743.32 (717) 605-4048
X 1 X 35 X 2 X 4 X 62
X 17 X 27
X 28 X 63 X 32 X 73 X 34 X 82
PAGES
OFPAGEREFERENCE NO. OF DOCUMENT BEING CONTINUED
NAME OF OFFEROR OR CONTRACTOR
CONTINUATION SHEET
ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
N00104-19-R-FB71 2 84
0001 NSN 4YH 4820-01-111-9504 L1
VALVE,BALL SHELF LIFE 0-00
SEE TECHNICAL REQUIREMENTS IN SECTIONS C, D, E, AND ATTACHMENTS
HM QUP ICQ PMT CD PM WM CUD CT UC LP IC UCL SP MK PACK UNIT PKWT UNIT PKCU OPI
N 001 000 ZZ 1 00 ZZ LK H F2 A 00 A 00 FFF 706.0 11.484 A
SUP PKG: ZZ = PACKAGE PER MIL-V-3
PACKAGING IS IN ACCORDANCE WITH MIL-STD-2073
SHIP TO
0001AA N00104-18-X-B703 N50286 4 EA
TP: 3
0001AB SEE DD FORM 1423 1 LO NSP
EXHIBIT "A"
0001AC OPTION QTY UP TO 100% OF ITEM 0001
NOTES:
PROSPECTIVE OPTION QUANTITY UP TO 100% WITHIN 365 DAYS.
STEPLADDERS
1EA - 2EA $_____
3EA - 4EA $_____
1. If no unit prices are submitted for item 0001AC, the unit price submitted for item 0001AA will be considered the unit price for item 0001AC.(all stepladder quantities). Offerors shall supply a unit price for eachstepladder quantity shown above. Failure to do so could result in an option exercised for a relatively small quantity at the basic contract price.
2. Any exception to the option may render your offer unacceptable.
3. For evaluation purposes only, the price submitted for the largest stepladder quantity will be utilized. This in no way limits the Government's ability after award to exercise a partial option at the appropriate stepladder unit price. If the stepladder quantities are not where the price breaks occur, the contractor is encouraged to provide different stepladder quantities.
SOLICITATION NOTES:
1. DD1423 Data Item A001 may be waived if already on file at NAVSUP WSS Mechanicsburg.
2. Consistent with FAR 52.216-18, all contractual documents (i.e. contracts, purchase orders, task orders, delivery orders, and modifications) related to the instant procurement are considered to be "issued" by the Government when
PAGES
OFPAGEREFERENCE NO. OF DOCUMENT BEING CONTINUED
NAME OF OFFEROR OR CONTRACTOR
CONTINUATION SHEET
ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
N00104-19-R-FB71 3 84
copies are either deposited in the mail, transmitted by facsimile, or sent by other electronic commerce methods, such as email. The Government's acceptance of the contractor's proposal constitutes bilateral agreement to "issue" contractual documents as detailed herein.
3. This is a TRIPER/AERP item which requires SUBMEPP (Code 1831) approval of certifications prior to shipment of material.
4. In accordance with 52.219-6 this is a total small business set aside.
5. TIN 361 applies to this solicitation.
INSPECTION AT ORIGIN
ACCEPTANCE AT ORIGIN
POC EMAIL: ROYCE.HOFFMAN@NAVY.MIL
N00104-19-R-FB71 PAGE 4 OF 84
PART I - THE SCHEDULE
SECTION B
SUPPLIES OR SERVICES AND PRICES/COSTS
WSSTERMBA00
CONTACT INFORMATION
When a DCMA office is shown on a Contract/Purchase Order, the Administrative Contracting Officer (ACO) is the primary point of contact and all inquiries shall initially be directed to that office for necessary action. PLEASE REFER TO
THE FRONT PAGE BOX 7.
FOR ALL OTHER inquiries and correspondence directed to the Post Award PCO/Contract Specialist should be addressed as follows:
Code: ( <TBD> ) Weapon System LRC: ( <WT6RR> ) Telephone: ( <TBD> ) E-Mail: ( <TBD> )
In the event that the listed PCO contact information is no longer valid and a follow-on PCO cannot be identified, contact NAVSUPWSSITIMPHelpdesk@navy.mil.
WSSTERMBZ04
IMPORTANT NOTICE REGARDING HAZARDOUS MATERIAL
FAR clause 52.223-3, Hazardous Material Identification and Material Safety Data, is incorporated by reference in Section I in this solicitation ad required offerors to--
(1) identify any hazardous material (defined in FED STD 313 as an item or chemical which is a "health or physical hazard" per OSHA in 29 CFR 1910.1200) that will be delivered under a resultant contract, and
(2) provide a Material Safety Data Sheet meeting OSHA/FED STD 313 requirements for all hazardous material identified.
While not an all-inclusive listing of hazardous material, at a minimum, any it em with a four-digit Federal Supply Code (FSC), which correlates to the first four positions of the National Stock Number (NSN), of 6810, 6820, 6830, 6840, 6850, 7930, 8010, 8030, 8040, 9110, 9135, 9140, 9150, or 9160 is considered hazardous material and requires submission of a Material Safety Data Sheet or an appropriate representation that there is no hazardous material contained in the item.
Failure to provide the required information and documentation may render you ineligible for award. If you have questions about whether a solicited item is classified as hazardous, contact the NAVSUP WSS HAZMAT point of contact, NAVSUP WSS Code 0772, at (717)605-1361. (10-06)
PART I - THE SCHEDULE
SECTION C
DESCRIPTION/SPECIFICATIONS/WORK STATEMENT
CLIN: 0001
NIIN: 011119504 ACTIVITY USE ONLY: TDP VERSION NO.: 010
ITEM NAME: VALVE,BALL
1. SCOPE
1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material.
2. APPLICABLE DOCUMENTS
2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order shall take precedence. Nothing in this contract/purchase order, however, shall supersede applicable laws and regulations unless a specific exemption
N00104-19-R-FB71 PAGE 5 OF 84
has been obtained.
2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions.
2.2.1 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order.
2.3 Specification Revisions - The specification revisions listed under "Docu ments References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract.
2.3.1 Documents, drawings, and publications supplied are listed under "Drawing Number". These items should be retained until an award is made.
2.4
DRAWING NO. CAGE REV DOC TYPE DISTR CD SHEET NR REV TYPE SIZE
1889753 53711 J D3 0001 J 49998 0816762
2640-808X1J1 53711 A ER D3 0001 A 49998 0487192
2640-809X10 96169 C D3 0001 C 49998 0046158 4558766 80064 E D3 0001 E 49998 0124267 4558766 80064 E D3 0002 E 49998 0118211 4558766 80064 E D3 0003 E 49998 0098547 4558766 80064 E D3 0004 E 49998 0074376 4558766 80064 E D3 0005 E 49998 0079537 4558766 80064 E D3 0006 E 49998 0082494 4558766 80064 E D3 0007 E 49998 0092812 4558766 80064 E D3 0008 E 49998 0077701 4558766 80064 E D3 0009 E 49998 0089388 4558766 80064 E D3 0010 E 49998 0081709 4558766 80064 E D3 0011 E 49998 0087864 4558766 80064 E D3 0012 E 49998 0070378 4558769 53711 D D3 0001 D 49998 2875470 4558795 80064 F D3 0001 F 49998 0221672 4558796 80064 C D3 0001 C 49998 0271361 7285195 53711 D D3 0001 D 49998 0690343 7285198 53711 L D3 0001 L 49998 0732242 7285297 53711 E D3 0001 E 49998 0862180 7285297 53711 E D3 0002 E 49998 0392982 7285297 53711 E D3 0003 E 49998 0280881 7285297 53711 E D3 0004 E 49998 0204692 7286168 53711 G D3 0001 G 49998 0660728 7286250 53711 J D3 0001 J 49998 0350803 8617511 53711 M D3 0001 M 49998 0842926
DOCUMENT REFERENCES
SPEC NO. SLASH NO. PART NO REV DATE DISTR CD AMEND CHG NTC SUPP
FED-STD-H28 A 28 DEC 94 A
FED-STD-H28 0020 B 21 DEC 94 A 01
ANSI/ASQ Z1.4 01 JAN 08 A
MMM-A-132 B 01 APR 94 A
QQ-N-281 D 23 OCT 85 A 2
QQ-N-286 G 07 DEC 00 A
ASTM-B367 01 JUL 13 A
ASTM-B369 01 APR 09 A
ASTM-B505 01 APR 14 A
TT-P-645 B 12 MAR 90 A
MIL-STD-792 F 19 MAY 06 A
MIL-DTL-1222 J 08 DEC 00 A
ASTM-E1417 01 JUN 13 A
ASTM-E1444 16 JUN 16 A
MIL-STD-2035 A 15 MAY 95 A
N00104-19-R-FB71 PAGE 6 OF 84
SAE AMS 2631 E 01 DEC 17 A
ASTM-D4066 01 JUL 13 A
ASTM-D5363 01 APR 16 A
SAE AMS 6931 D 01 DEC 17 A
ISO_9001 15 NOV 08 A
ISO10012 15 APR 03 A
MIL-DTL-15024 G 03 MAR 18 A
MIL-DTL-15090 E 12 OCT 10 A
ISO/IEC 17025 15 MAY 05 A
MIL-N-25027 0001 A 31 MAR 99 A 1
MIL-I-45208 A 24 JUL 81 A 1
MIL-STD-45662 A 01 AUG 88 A
MIL-S-46163 A 03 FEB 95 A 3
A-A-59004 A 07 SEP 95 A
ANSI/NCSL Z540.3 26 MAR 13 A
AIA/NAS NASM 25027 1 21 DEC 12 A
S9074-AQ-GIB-010/248 01 AUG 95 A
T9074-AS-GIB-010/271 1 11 SEP 14 A
S9074-AR-GIB-010A/278 (CHG A) 14 FEB 13 A
3. REQUIREMENTS
3.1 <The 3 inch Ball Valve shall be in accordance with Naval Sea Systems Command Drawing 845-4558795, Assembly "SIRCWT" (Less hull fasteners and hydraulic actuator item 31), except as amplified or modified herein. All actuator associated pieces shall be supplied in a bag attached to the valve.>
3.2 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise:
Part - <Body, item 3 and Cover, item 7> Material - <ASTM-B369, Alloy UNS C96400>
Part - <Stem, item 11 and Stem, item 13> Material - <QQ-N-286, Form 2, Annealed and Age Hardened>
Part - <Stem Retaining Nut, item 86 and Stem Retaining Nut, item 88> Material - <ASTM-B505, Alloy UNC C90300>
Part - <Studs, item 94> Material - <MIL-DTL-1222, QQ-N-286, Type IV, Annealed and Age Hardened, and Marked .K.>
PART - <Self-Locking Heavy Hex Nuts, item 60> MATERIAL - QQ-N-281, Class A or B, in accordance with MIL-N-25027/1.
All material shall be the same Class.
SELF-LOCKING ELEMENT - ASTM-D4066, Group 01, Class 1 or 2, Grade 1.
For Boilerplate R00375, Part - <Ball, piece 92 and Ball, piece 93> Material - SAE-AMS-6931
OR
Centrifugally cast 6AL-4V, ASTM-B367, Grade C-5, with mechanical properties as listed in supplementary Requirement S6.
Note: Mechanical properties for bars, forgings and forging stock over 10" shall be as specified in the applicable drawing. If the mechanical properties are not provided in the drawing, the mechanical properties specified in SAE-AMS-6931 Table 2 for material 6" to 10", shall be applied. Part - <Seats (Q3), piece 27 and piece 28> Material - MD71-GG Mearthane (Graphite Filled Urethane). Material must be manufactured by Mearthane Products Inc.
Cranston, RI. (Properties Specified Below Only)
ITEM PROPERTY ASTM TEST METHOD VALUE
(A) Hardness D2240 70 +/- 5 Shore D
(B) Specific Gravity D792 1.18 +/- 0.02
(C) Tensile Strength D412 (DIEC) 5000 PSI MIN
(D) Compression-Defl D575 700 PSI MIN @ 2% DEF.
(E) Tensile Impact D1822 300 FT-LB/SQ IN
(Note 1) (TYPE L SPECIMEN)
(F) Water Absorption D570 1.5% MAX
(1 Week at R.T.)
N00104-19-R-FB71 PAGE 7 OF 84
Note 1: These values are minimum averages. Separate specimen values may not vary more than 25% under the specified minimum.
3.3 Testing Certification - Certifications are required for the following tests on the items listed below.
Additional testing on other piece parts (if any) per applicable drawings is still required, but certifications are only required as listed below.
Test - <Liquid Penetrant Inspection> Item - <Studs, item 94> Performance - T9074-AS-GIB-010/271; Sampling shall be per MIL-DTL-1222 Acceptance - MIL-DTL-1222
Test - <Dye Penetrant Inspection for Non-Magnetic Grades> Item - <Self-Locking Heavy Hex Nuts, item 60> Performance - T9074-AS-GIB-010/271 or ASTM-E1417/ASTM-E1444
(Method C solvent removal techniques shall not be used on thread) Acceptance - <NASM25027 with sampling in accordance with MIL-N-25027/1>
Attribute - Annealing and Age Hardening Item - <Stem, piece 11, Stem, piece 13, Studs, piece 94> Performance - QQ-N-286
Test - Weldability Test of ASTM-B369 material Item - <Body, item 3 and Cover, item 7> Performance - ASTM-B369 Acceptance - ASTM-B369
Test - Pressure Tests Item - Each Assembly Performance - <General Notes 6 and 8.B on Drawing 845-4558795. Test 6.A shall be for 5 minutes minimum. The pressure tolerance for all tests is +2% - 0%.> Acceptance - <General Notes 6 and 8.B on Drawing 845-4558795. The maximum torque value for test 8.B shall be 850 in-lbs in lieu of 1120 in-lbs.>
Test - Quality Conformance Tests Item - Self-Locking Nuts Performance - <NASM25027 and MIL-N-25027/1> Acceptance - <NASM25027 and MIL-N-25027/1>
Attribute - Certificate of Completion Item - Self-Locking Nut Nonmetallic Insert Performance - ASTM-D4066, Group 01, Class 1 or 2, Grade 1
Attribute - Certificate of Compliance Item - Self-Locking Nuts Performance - This Certificate shall state that self-locking nuts were manufactured by an approved source. Approved sources are those listed on QPL-25027 for the appropriate fastener. This QPL may also be considered as approved sources for Heavy Hex self-locking nuts.
Attribute - <Torque and Lubrication> Item - <Self-locking Fastener (Piece 60)> Performance - <General Note 17 on Drawing 845-4558795>
3.4 <QQ-N-281 Hot Finished Plate may be used for Piece 49 of drawing 4558795 in lieu of QQ-N-288 compostion A.
Chemical and mechanical certification is not required.>
3.5 Radiography is required on <Body, piece 3, and the Cover, piece 7.> .
3.6 Component Identification - A Triper serial number will be assigned to each component and a nameplate will be provided by NAVSUP WSS MECH, Code N97121, as Government Furnished Equipment (GFE) prior to packaging and shipment.
The Contractor is requested to notify NAVSUP WSS MECH, Code N97121, when the manufacturing process is ready for the nameplate(s), allowing sufficient time for mailing. Individual serial numbers shall to be stamped onto nameplate using 3/16" letters and filled with red paint prior to installation on the components. Nameplates should be attached in the locations specified on the drawing provided for this purpose, utilizing an epoxy compound which meets the requirements of Federal Specification MMM-A-132. The manufacturer's instruction should be followed to ensure proper adhesion. Subsequent to installation, painted surfaces adjacent to the nameplate should be touched up with primer equivalent to TT-P-645 and one coat of light gray paint equivalent to MIL-DTL-15090. Prior to shipment, each packaging container shall have the appropriate Triper program serial number marked externally as follows:
"TRIPER PROGRAM MATERIAL"
SERIAL NUMBER - ______
N00104-19-R-FB71 PAGE 8 OF 84
3.7 A visual inspection shall be performed on the finished seat with acceptance criteria on critical surfaces per CSD167 in the ECDS (Electronic Contractor Data Submission) system at: https://register.nslc.navy.mil/.
3.8 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor shall prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings.
3.9 Seat Stack Height Measurement - To ensure that each seat is within tolerance, check each seat singularly by measuring the seat height over the ball. This measurement is calculated by adding one-half ball diameter to the half stack height dimension on the drawing. Limits are determined by the ball diameter tolerance and the half stack height tolerance. Check dimensions by measuring from the seat back face to top of ball. Manufacturers of seats that do not have a ball of the required size available will be required to manufacture a dummy ball or segment of a ball with sufficient spherical surface to check the above dimension.
3.10 Slow Strain Rate Tensile Test Laboratories - The Slow Strain Rate Tensile Test of QQ-N-286 must be performed by one of the following laboratories:
Huntington Alloys, a Special Metals Company Attn: Frank Veltry huntington, WV 25705 Phone: (304) 526-5759
FAX: (304) 526-5973
Metallurgical Consultants, Inc.
Attn: W. M. Buehler 4820 Caroline PO Box 88046 Houston, TX 77288-0046 Phone: (713) 526-6351
FAX: (713) 526-2964
Naval Surface Warfare Center, Carderock Division Attn: Eric Focht Code 614 9500 Macarthur Blvd West Bethesda, MD 20817-5700 Phone: (301) 227-5032
FAX: (301) 227-5576
Teledyne Allvac Attn: Dr. W. D. Cao 2020 Ashcraft Ave.
Monroe, NC 28110 Phone: (704) 289-4511
FAX: (704) 289-4269
Westmoreland Mechanical Testing and Research Inc.
Attn: Andrew Wisniewski P.O. Box 388 Youngstown, PA 15696-0388
Mannesmann Rohrenwerke Mannesmann Forschungsinstitut (MFI) Attn: Dr. Weiss Postfach 251160 47251 Duisburg Germany Phone: 011-49-0203-9993194
FAX: 011-49-0203-9994415
ThyssenKrupp VDM USA, Inc.
Attn: D. C. Agarwal 11210 Steeplecrest Drive, Suite 120 Houston, TX 77065-4939 Phone: (281) 955-6683
3.11 K-MONEL Fasteners - Material shall be heat treated per QQ-N-286.
3.11.1 Fasteners that have been hot or cold headed or roll threaded shall be solution annealed followed by age hardening subsequent to all heading and thread rolling operations. The mechanical properties on certifications must be actual properties of the annealed and age hardened material and must meet the requirements of QQ-N-286.
N00104-19-R-FB71 PAGE 9 OF 84
3.11.2 QQ-N-286 fasteners that have been headed and/or roll threaded shall not beage hardened unless the material has been solution annealed subsequent to the heading and threading operations. Threads formed after the final age hardening heat treatment shall be cut or ground only.
3.12 K-MONEL Fasteners - K-MONEL externally threaded fasteners shall have mechanical properties determined in accordance with MIL-DTL-1222. Test results shallinclude Tensile, Yield, Elongation and Hardness as required by MIL-DTL-1222. (The Hardness tests shall be performed on a full size fastener.)
3.12.1 Studs require an Axial Tensile test in accordance with MIL-DTL-1222.
3.12.2 Headed fasteners require a Wedge Tensile test as specified elsewhere in this contract/purchase order.
3.13 Thread Inspection Requirements - All threads on threaded parts shall be inspected using appropriate inspection methods, inspection systems, and inspection gages/instruments in accordance with FED-STD-H28 series. Substitution of thecommercial equivalent inspection in accordance with ASME B1 series is acceptable.
3.13.1 System 21 of FED-STD-H28/20 shall be used as a minimum inspection requirement for threads when the design drawing or design specification does not specify an inspection requirement.
3.13.2 For Navy and Shipyard drawings, system 21 of FED-STD-H28/20 may be substituted for System 22 without further Navy approval when the design drawing invokes System 22 and does not cite governing specifications that specifically require system 22. System 22 of FED-STD-H28/20 shall be used when the drawing references other governing specifications that specifically require System 22, such as certain thread types of MIL-DTL-1222.
3.13.3 A written request for concurrence must be submitted when utilizing alternative measuring equipment or measuring systems not applicable to the specified inspection system.
3.14 Thread Lubricant - Thread lubricants containing molybdenum disulfide shall not be used on this material.
Bacteria in water, especially seawater, causes molybdenum disulfide to break down. The by-products of the breakdown form compounds which attack the fasteners. Anti-galling compound A-A-59004 (or copper or nickel based anti-seize compounds if A-A-59004 is not available) shall be used as a replacement when thread lubricant is required for assembly.
3.15 <During reassembly, liberally coat the following surfaces with grease per CID A-A-50433 (Termalene No.2):
ball cavity, stem cavity (excluding threads), ball outer surface, ball seats, O-rings and O-ring mating sealing surfaces, and all stem surfaces (excluding any splines).>
3.16 <For fasteners which require thread-sealing or thread-locking compound, the compound and its application must comply with ASTM-D5363, Grade AN0123 or AN0124, or MIL-S-46163, Type I, Grade K or L, or MIL-S-46163, Type II, Grade M or N. Locking effectiveness of the compound must be checked in accordance with SAEJ2270 or other NAVSEA-approved procedure.>
3.17 Dupont Teflon Coating 850G-204 and 852G-201. Use of Dupont Teflon Coating 851N-204 and 852N-201 is acceptable until exhausted - Teflon coating of ball(s) shall be in accordance with general note <8 and CSD018> of drawing <8617511 item 92> .
3.18 Dupont Teflon Coating 850G-204 and 852G-201. Use of Dupont Teflon Coating 851N-204 and 852N-201 is acceptable until exhausted - Teflon coating of ball(s) shall be in accordance with general note <5 and CSD018> of drawing <7285198 item 93> .
3.19 Contract Support Library - Additional requirements for this item are identified as Contract Support Library Reference Number <CSD 018, CSD019 and CSD099> in ECDS at https://register.nslc.navy.mil/
3.19.1 CSD099 provides guidance for acceptance/rejection of teflon-coated valve balls after valve assembly production testing.
3.20 Internal Threads - All internal threads shall be formed by cutting. Cold forming of internal threads is not acceptable.
3.21 Specification Change - For QQ-N-281, Class B material:
1 - Footnote 9 to Table II of QQ-N-281 does not apply.
2 - When starting material is Round Bar greater than 3" dia, the mechanical properties of Hex Bar apply.
3.22 Component Identification Description (CID) - When applicable drawing(s) and/or specification(s) specify that a nameplate or identification plate is required, the CID number ( <T884245578> ) shall be added. When no plate is specified, an identification plate in accordance with MIL-DTL-15024, Type "C" on brass or Type "H" on aluminum shall be securely attached to each assembly showing the above CID number. No assembly shall be shipped without the CID number attached.
3.23 Welding or Brazing - When welding, brazing, and allied processes are required, they shall be in accordance
N00104-19-R-FB71 PAGE 10 OF 84
with S9074-AR-GIB-010A/278, (S9074-AQ-GIB-010/248 for brazing) by personnel and procedures qualified under S9074-AQ-GIB-010/248 for all production welding and brazing. Repair welding is not permitted <UNS C90300 material> .
Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing.
3.24 Configuration Control - The Contractor shall maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration shall be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order.
3.24.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations shall be designated as Critical, Major, or Minor.
The Contractor shall provide a copy of this request to the QAR. Requests shall include the information listed below.
a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor.
b. Number of units (and serial/lot numbers) to be delivered in this configuration.
c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product.
d. Information about remedial action being taken to prevent reoccurrence of the non-conformance.
3.24.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts shall be submitted using the ECDS (Electronic Contractor Data Submission) system at https://register.nslc.navy.mil/
3.24.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor shall submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs shall be prepared in Contractor format, and shall include the following information:
a. The change priority, change classification (Class I or Class II), and change justification.
b. A complete description of the change to be made and the need for that change.
c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs.
d. Proposed changes to documents controlled by the Government.
e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration.
f. Recommendations about the way a retrofit should be accomplished.
g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product.
h. Impacts to the operational use of the product.
i. Complete estimated life-cycle cost impact of the proposed change.
j. Milestones relating to the processing and implementation of the engineering change.
3.25 Mercury Free - Mercury and mercury containing compounds shall not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection.
3.26 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order. The above documents are for GovernmentUse Only. Further application of the above documents is prohibited.prohibited.
3.26.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners shall be marked with a Material Symbol/Designator as specified elsewhere in this contract.
* QUALITY ASSURANCE REQUIREMENTS *
3.27 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested shall be furnished along with a copy of the test results. Certification shall include the contractor's name, address and date, quantity inspected, identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptance criteria used. Test procedure numbers may also be referenced on test reports. Test reports on weldments shall be identified to weld joint and layer.
3.28 Radiography (RT) - Radiography shall be performed in accordance with T9074-AS-GIB-010/271. RT acceptable criteria for castings to be criticality level Iper the applicable table of S9074-AR-GIB-010A/278. RT acceptance
N00104-19-R-FB71 PAGE 11 OF 84
criteria for weldments to be per the applicable table of S9074-AR-GIB-010A/278 (P-1 piping) or MIL-STD-2035, class 1, as applicable.
3.28.1 See CDRL DI-MISC-80678 (RSS) - The Contractor or activity performing theradiography shall be responsible for preparing the radiographic shooting sketches (RSS) in accordance with T9074-AS-GIB-010/271. Shooting sketches are not required for radiography of weldments. The radiographic standard shooting sketches (RSSS) referenced on the applicable drawing may be used, however, since T9074-AS-GIB-010/271 permits a variety of processes, the RSSS may not be applicable as they will not necessarily depend only on the coverage requirements, but also on the equipment and procedures of the particular radiographic facility. Approval of these shooting sketches or radiographic standard shooting sketches is required per S9074-AR-GIB-010A/278. If this datahas been previously approved by a Navy activity, the original approval letter shall be submitted at the same time as RT film and reader sheet submittal.
3.28.2 All pieces radiographed shall be permanently marked with "RT" and a unique RT serial number. (The unique RT serial number must be directly traceable tothe RT film.)
3.28.3 See CDRL DI-MISC-80678 (Production Radiography) - Production Radiographyrequires final acceptance by the Navy. The items listed below shall be submitted for final acceptance, cataloging, file, and retention. They must be submitted and approved prior to shipment of the applicable hardware. However, when the source certification clause is invoked, they must be submitted a minimum of forty-five (45) working days prior to the date of source certification inspection.
(a) Film
(b) RSS/RSSS
(c) RS
(d) DD250 (with unique RT serial numbers traceable to the RT film)
3.29 Welding Requirements - When production or repair welding is required, the applicable welding procedure(s) and qualification data shall be submitted for review and approval. In addition, the CONSUMED WELD METAL C of C as defined below shall be submitted as part of the certification OQE package submitted by the Contractor.
Note: These requirements do not apply to tack/spot welds.
3.29.1 Approval of the Contractor's qualification data shall be obtained prior to performing any welding (production or repair).
3.29.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process. The approval letter must reference the applicable welding procedure and qualification data report identification/number. Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract shall be submitted at the same time. Welding procedures and qualification data shall be submitted in a commercially available electronic format such as Adobe Acrobat PDF. The contractor shall state the applicability of each weld procedure and qualification data submitted, citing the drawing number and pieces to be welded. (i.e. "WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC." " WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ."). Authority for the repair of Special Repairs in castings and authority for the repair of wrought or forged material material shall be obtained from the Procurement Contracting Officer. This request shall describe the defect; including size, depth, location, and a description of the proposed repair. This request for NAVSUP-WSS Contracts shall be submitted via the Electronic Contractor Data Submission (ECDS) application.
3.29.3 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 48 hour notification to DCMA with an offer to observe the welding of the test assemblies. The 48 hour time limit may be modified upon mutual agreement between the vendor and DCMA.
3.29.4 When drawings require hard facing surface Iron content (Nickel for Monel valves) not to exceed 5%, the contractor shall verify surface Iron or Nickel content by performing chemical testing as defined by the applicable drawing. The chemical test results shall be submitted as part of the qualification data.
3.29.5 Qualification requirements for production hardfacing: The maximum qualified thickness for hardfacing shall be twice the weld deposit thickness measured in the as-welded condition that is subjected to initial NDT (Non-Destructive Testing) and any additional drawing requirements. The minimum qualified thickness is the final machined thickness at which hardness testing, NDT, macro-etch, and any additional drawing requirements are satisfactorily performed.
3.29.6 Additional qualification requirements for production hardfacing thickness less than 1/8-inch: Macro-etch (or legible photomacrographs) shall be submitted for review and show consistent, minimized dilution. All essential elements and any elements not listed in S9074-AQ-GIB-010/248 that influence dilution shall be in the qualification data and weld procedure, with strict limits placed on each essential element.
3.29.7 Qualification requirements for production cladding: The maximum qualified thickness for cladding shall be twice the weld deposit thickness measured in the as-welded condition that is subjected to initial NDT and any additional drawing requirements. The minimum qualified thickness is the final machined thickness at which NDT, side bends, macro-etch testing, and any additional drawing requirements are satisfactorily performed.
N00104-19-R-FB71 PAGE 12 OF 84
3.29.8 When weld repair is required on titanium material, the applicable fabrication plan, facilities procedure, training plan, and active welder qualification shall be submitted for review and approval.
3.29.9 If the contractor's fabrication plan, facilities procedure, training plan, or active welder qualification has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the applicable documentation to expedite the approval process. The approval letter must reference the applicable documentation. Prior approval does not guarantee acceptance for this or any future contracts. The contractor's fabrication plan, facilities procedure, training plan, and active welder qualification shall be submitted at the same time as the applicable welding procedure(s) and weld procedure qualification data. All documentation shall be submitted in a commercially available electronic formation, such as Adobe Acrobat PDF.
3.29.10 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of
S9074-AR-GIB-010A/278.
3.29.11 A Certificate of Compliance is required for all weld filler metals used for production or repair welding, and shall include the following:
a) Filler Metal LOT number(s)
b) Specification and Type
c) A positive statement that the vendor has obtained OQE and verified that each LOT of weld filler material conforms to specification requirements.
d) A positive statement verifying that the weld filler metals were the correct material type or grade prior to consumption.
3.29.12 When production welds or repair welds are performed by a subcontractor, the requirement for submission of all certification documentation required herein shall be passed down to the subcontractor.
3.30 Quality System Requirements - The Contractor furnishing items under this contract/purchase order shall provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012 or ANSI-Z540.3 with ISO-17025. A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate.
3.30.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/non-acceptance by the Government representative to determine the system's effectiveness in meeting the quality requirements established in the Contract/Purchase Order.
3.30.2 The Contractor's quality system shall be documented and shall be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract. The Prime Contractor shall, upon notification, make his facilities available for audit by the contracting Officer or his authorized representative.
3.30.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Level I/SUBSAFE (LI/SS) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting Officer (PCO) prior to award of any contract/purchase order. Suppliers that have a copy of their current quality system procedures on file at the Procuring Activity may request the PCO waive this requirement.
3.30.4 This contract provides for the performance of Government Quality Assurance at source. The place or places of performance may not be changed without the authorization of the Procurement Contracting Officer. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately.
3.30.5 Any changes made by the Contractor to a qualified quality system will require re-submittal to the PCO and concurrence by the Government Quality Assurance Representative prior to adoption.
3.31 Contractor Inspection Requirements - The Contractor shall maintain adequate records of all inspections and tests. The records shall indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved and rejected and the nature of corrective action taken as appropriate. Inspection records shall be traceable to the material inspected.
3.31.1 The supplier's gages, measuring and test equipment shall be made available for use by the Government representative when required to determine conformance with Contract requirements. When conditions warrant, the supplier's personnel shall be made available for operations of such devices and for verification of their accuracy and condition.
3.31.2 All documents and reference data applicable to this contract shall be available for review by the Government representative. Copies of documents required for Government inspection purposes shall be furnished in accordance with the instructions provided by the Government representative.
3.32 Subcontractor Inspection Requirements - The Government has the right to inspect at source, any supplies or services that were not manufactured or performed within the contractor's facility. Such inspection can only be
N00104-19-R-FB71 PAGE 13 OF 84
requested by or under authorization of the Government representative. Any purchasing documents to a subcontractor must cite the applicable portions of the contractually invoked quality system (e.g. calibration requirements), plus any product requirements that apply to the supplies being purchased. When the Government elects to perform source inspection at the subcontractor's facility, applicable purchase documents shall be annotated with the following statement: "A Government inspection is required prior to shipment from your plant. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately."
3.33 The prime contractor's program shall include procedures to assess the capability of the prospective suppliers to produce the products or supply the services in accordance with the contract, prior to the issuance of any purchase document.
3.33.1 Each sub-tier supplier of material or services for items in Section 3 of this contract shall be subjected to a periodic review or audit by the Prime to determine the continued capability of the supplier to control the quality of the products or services specified in the purchase order or contract.
3.33.2 The prime contractor shall ensure that the purchased product conforms to specified purchase requirements and this contract. The type and extent of control applied to the supplier and the purchased product shall be dependent upon the effect of the purchased product on the end item represented by this contract.
3.33.3 The prime contractor shall evaluate the requirements of the contract and select suppliers based on their ability to supply the product in accordance with the prime contractor's requirements and the contract. Criteria for selection and evaluation shall be established. Records of this effort shall be available for review by the government.
3.33.4 The prime contractor's supplier quality assurance program shall provide for a review of purchase documents to assure applicable quality requirements are included or referenced in the documentation for compliance by the supplier.
3.34 Government Furnished Material and/or Equipment (GFM/GFE) - When material or equipment is furnished by the Government, the Contractor shall develop documented control procedures that require at least the following:
3.34.1 Visual examination upon receipt to detect damage during transit.
3.34.2 Inspection for completeness and proper type.
3.34.3 Verification of material quality received.
3.34.4 Periodic inspection and precautions to assure adequate storage conditions and to guard against damage from handling and deterioration during storage.
3.34.5 Functional testing, either prior to or after installation, or both, as required by the Contract to determine satisfactory operation.
3.34.6 Identification and protection from improper use or disposition.
3.34.7 Reporting to the Government, any GFM or GFE property found damaged, malfunctioning, or otherwise unsuitable for use. In the event of damage or malfunction during or after installation, the supplier shall determine and record probable cause and necessity for withholding the material from use.
3.34.8 For GFE material, and as required by the terms of the bailment agreement, the supplier must establish procedures for adequate storage, maintenance, and inspection of bailed Government material. Records of all inspection and maintenance performed on bailed property shall be maintained.
3.34.9 Material returned to the contractor shall be handled as GFM.
3.35 Traceability and Certification Requirements - To assure that correct materials are installed in Level I/SUBSAFE systems, it is imperative that traceability be maintained from the material to the material certification…
This is the start of the file's text. The full file is on GovTribe.