MATERIAL ORDERING DATA
MIL-C-15730M
IDN: N4523A 2133-4000
ICN: 38RTC587AB KO: S01 KOI: 001
Paragraph 6.2 Ordering Data
a) MIL-C-15730M, Coolers, Fluid, Naval Shipboard: Lubricating Oil, Hydraulic Oil, and Fresh Water, dated 24 May 1995, and Amendment 1, dated 28 Mar 1997.
b) Type:1 class:3 and service:Surface ship, hydraulic oil of cooler.
c) Issue of DoDISS to be cited in the solicitation, and if required, the specific issue of individual documents referenced:
d) Identification of fluid to be cooled: MIL-H-22072. Lubricating oil should be designated by specification or military symbol.
e) Rate of flow of fluid to be cooled: 239 gal/min.
f) Inlet temperature of fluid to be cooled: 110 degrees F.
g) Outlet temperature of fluid to be cooled: 105 degrees F, or rate of heat exchange:
475,000 Btu per hour.
h) Identification of coolant: SEAWATER
i) Rate of flow of coolant, if established: 200 gal/min.
j) Design pressure of fluid to be cooled: 150 lb/in2
k) Design pressure of coolant: 55 lb/in2
l) Whether coolers are for submarine, surface ship, landing craft, or small boat application:
SURFACE SHIP.
m) When first article inspection is required: N/A.
n) Space and weight limitations governing the cooler size, if established: SEE ATTACHED
DRAWING COOLER 12090 EF
o) Ship motion and attitude requirements, if other than specified: AS SPECIFIED BY MIL-
C-15730M
p) Allowable design point pressure drops for respective cooler sides: AS SPECIFIED BY
MIL-C-15730M lb/in2, if other than as specified.
q) Inlet temperature of coolant, if other than specified: 85 degrees F.
r) Inlet and outlet connection size: SEE ATTACHED DRAWING COOLER 12090 EF and whether hose connections are required: NO HOSE CONNECTIONS
s) Description of inlet and outlet flanges, if other than specified: SEE ATTACHED
DRAWING COOLER 12090 EF.
t) Size: 1/2" & 1/4" IPS, wall thickness: 0.065" & 0.095", and material: 90/10 & 70/30 CU-
NI respectively (see DWG) of installer-furnished vent and drain tubing.
u) Whether pressure gage connections are required at inlet and outlet of coolant and cooled fluid sides: NOT REQUIRED.
v) Whether o-rings are required in lieu of flat gaskets: SEE ATTACHED DRAWING
COOLER 12090 EF.
w) Gasket width, if other than specified: AS SPECIFIED BY MIL-C-15730M.
x) Gasket material for type I coolers, when metal-to-gasket temperature is greater than 250 deg F, if other than in accordance with MIL-G-24696: N/A.
y) Rubber for o-rings if other than specified: AS SPECIFIED BY MIL-C-15730M.
z) When additional material requirements or restrictions apply: N/A.
aa) Whether steel shell side materials are required or may be used: NO.
bb) Whether aluminum shell side internals are required or may be used: NO
cc) When materials in accordance with Table X are required for synthetic lubricating oil cooler: N/A.
dd) When U-bend tubes are required: NO.
ee) Which of the specified front end construction methods shall be used: HYDRAULIC
FLUID COOLER IAW 3.4.6 OF SPECIFICATION.
ff) Whether a gasket or O-ring shall be used in the tube sheet-to-shell and tube sheet-to-waterbox joint: GASKET.
gg) Whether double-tube-sheet construction is required: YES.
hh) Whether double tube construction is required: YES
ii) Whether shell-side tinning is required: NO
jj) Outside diameter and wall thickness of tubes if other than as specified: AS SPECIFIED
BY MIL-C-15730M.
kk) For Type I, Class I coolers, cyclic life requirements, if other than as specified: N/A.
ll) Diameter and thickness of attached circulating water piping: 3" IPS, 0.095" THK, 90/10
CUNI.
mm) For Type I, Class I coolers, the number of design cycles corresponding to 100% test depth changes, and the number of design cycles corresponding to 50% test depth changes: N/A.
nn) When aluminum alloys are specified for Type II coolers: N/A.
oo) Whether nonmagnetic construction is specified for Type II coolers: N/A.
pp) Additional cleaning and cleanliness requirements for Type I coolers if specified: AS
SPECIFIED BY MIL-C-15730M.
qq) Test fluid cleanliness requirements, when specified: N/A.
rr) Specific test conditions, when specified: N/A.
ss) Shock test requirements, if other than specified: AS SPECIFIED BY MIL-C-15730M.
tt) Hydrostatic test pressures for cooler shell sides: 225PSI, tube sides: 100PSI, and void spaces: 150PSI as applicable, if other than specified.
uu) When proof test cyclic loading is required: NOT REQUIRED.
vv) Level of preservation and packing required: COMMERCIAL.
ww) Oil and water side preservatives if other than specified: NO PRESERVATIVE
REQUIRED.
xx) Fire-retardant requirement when required: N/A.
yy) Special marking required: N/A.
Additional requirements: NONE
Prepared By: DAVID GIFFIN Code: 260.3
File details come from the government source that posted it. Updated .