MATERIAL ORDERING DATA.pdf

PDF 103 KB Posted

Attached to
FLUID COOLER Federal contract opportunity
Solicitation number
SPMYM222Q1896
Issued by
Defense Logistics Agency Land and Maritime

View the file

Other files for this federal contract opportunity

Other files attached to FLUID COOLER, newest first.
File Type Posted
SPMYM222Q1896U0005 AMENDMENT.pdf PDF
SPMYM222Q1896U0003 AMENDMENT.pdf PDF
SPMYM222Q1896U0002 AMENDMENT.pdf PDF
SPMYM222Q1896U0001 AMENDMENT.pdf PDF
SPMYM222Q1896 FLUID COOLER.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MATERIAL ORDERING DATA

MIL-C-15730M

IDN: N4523A 2133-4000

ICN: 38RTC587AB KO: S01 KOI: 001

Paragraph 6.2 Ordering Data

a) MIL-C-15730M, Coolers, Fluid, Naval Shipboard: Lubricating Oil, Hydraulic Oil, and Fresh Water, dated 24 May 1995, and Amendment 1, dated 28 Mar 1997.

b) Type:1 class:3 and service:Surface ship, hydraulic oil of cooler.

c) Issue of DoDISS to be cited in the solicitation, and if required, the specific issue of individual documents referenced:

d) Identification of fluid to be cooled: MIL-H-22072. Lubricating oil should be designated by specification or military symbol.

e) Rate of flow of fluid to be cooled: 239 gal/min.

f) Inlet temperature of fluid to be cooled: 110 degrees F.

g) Outlet temperature of fluid to be cooled: 105 degrees F, or rate of heat exchange:

475,000 Btu per hour.

h) Identification of coolant: SEAWATER

i) Rate of flow of coolant, if established: 200 gal/min.

j) Design pressure of fluid to be cooled: 150 lb/in2

k) Design pressure of coolant: 55 lb/in2

l) Whether coolers are for submarine, surface ship, landing craft, or small boat application:

SURFACE SHIP.

m) When first article inspection is required: N/A.

n) Space and weight limitations governing the cooler size, if established: SEE ATTACHED

DRAWING COOLER 12090 EF

o) Ship motion and attitude requirements, if other than specified: AS SPECIFIED BY MIL-

C-15730M

p) Allowable design point pressure drops for respective cooler sides: AS SPECIFIED BY

MIL-C-15730M lb/in2, if other than as specified.

q) Inlet temperature of coolant, if other than specified: 85 degrees F.

r) Inlet and outlet connection size: SEE ATTACHED DRAWING COOLER 12090 EF and whether hose connections are required: NO HOSE CONNECTIONS

s) Description of inlet and outlet flanges, if other than specified: SEE ATTACHED

DRAWING COOLER 12090 EF.

t) Size: 1/2" & 1/4" IPS, wall thickness: 0.065" & 0.095", and material: 90/10 & 70/30 CU-

NI respectively (see DWG) of installer-furnished vent and drain tubing.

u) Whether pressure gage connections are required at inlet and outlet of coolant and cooled fluid sides: NOT REQUIRED.

v) Whether o-rings are required in lieu of flat gaskets: SEE ATTACHED DRAWING

COOLER 12090 EF.

w) Gasket width, if other than specified: AS SPECIFIED BY MIL-C-15730M.

x) Gasket material for type I coolers, when metal-to-gasket temperature is greater than 250 deg F, if other than in accordance with MIL-G-24696: N/A.

y) Rubber for o-rings if other than specified: AS SPECIFIED BY MIL-C-15730M.

z) When additional material requirements or restrictions apply: N/A.

aa) Whether steel shell side materials are required or may be used: NO.

bb) Whether aluminum shell side internals are required or may be used: NO

cc) When materials in accordance with Table X are required for synthetic lubricating oil cooler: N/A.

dd) When U-bend tubes are required: NO.

ee) Which of the specified front end construction methods shall be used: HYDRAULIC

FLUID COOLER IAW 3.4.6 OF SPECIFICATION.

ff) Whether a gasket or O-ring shall be used in the tube sheet-to-shell and tube sheet-to-waterbox joint: GASKET.

gg) Whether double-tube-sheet construction is required: YES.

hh) Whether double tube construction is required: YES

ii) Whether shell-side tinning is required: NO

jj) Outside diameter and wall thickness of tubes if other than as specified: AS SPECIFIED

BY MIL-C-15730M.

kk) For Type I, Class I coolers, cyclic life requirements, if other than as specified: N/A.

ll) Diameter and thickness of attached circulating water piping: 3" IPS, 0.095" THK, 90/10

CUNI.

mm) For Type I, Class I coolers, the number of design cycles corresponding to 100% test depth changes, and the number of design cycles corresponding to 50% test depth changes: N/A.

nn) When aluminum alloys are specified for Type II coolers: N/A.

oo) Whether nonmagnetic construction is specified for Type II coolers: N/A.

pp) Additional cleaning and cleanliness requirements for Type I coolers if specified: AS

SPECIFIED BY MIL-C-15730M.

qq) Test fluid cleanliness requirements, when specified: N/A.

rr) Specific test conditions, when specified: N/A.

ss) Shock test requirements, if other than specified: AS SPECIFIED BY MIL-C-15730M.

tt) Hydrostatic test pressures for cooler shell sides: 225PSI, tube sides: 100PSI, and void spaces: 150PSI as applicable, if other than specified.

uu) When proof test cyclic loading is required: NOT REQUIRED.

vv) Level of preservation and packing required: COMMERCIAL.

ww) Oil and water side preservatives if other than specified: NO PRESERVATIVE

REQUIRED.

xx) Fire-retardant requirement when required: N/A.

yy) Special marking required: N/A.

Additional requirements: NONE

Prepared By: DAVID GIFFIN Code: 260.3

File details come from the government source that posted it. Updated .