M6700123P0014 MCS Tampa.pdf
PDF 1 MB Posted
- Attached to
- MCASB SC Telephone Equipment Support TAS/ETAS Federal contract opportunity
- Solicitation number
- M6700123P0014
- Issued by
- United States Marine Corps
About this file
This is an award notice for solicitation number M6700123P0014 to provide maintenance contract services for the Telecommunications Unified Communications system and subsystems at Marine Corps Air Station Beaufort in South Carolina. The incumbent contractor, MCS of Tampa, Inc., will receive $457,449.84 to perform maintenance, technical assistance, engineering support, material services, and occasional diagnostics from September 2023 through August 2024. The contract includes options to renew for three additional one-year periods. The services required include support for Avaya, Tellabs, Coriant, Alpha Technologies, Emerson, GEIST, and other equipment listed. The contractor must begin performance within seven days of award and complete all service tasks within twenty-one days.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUM
(No Collect Calls)
X
M6700123Q0014 11-Jul-2023
b. TELEPHONE NUMBER
910-451-7848
8. OFFER DUE DATE/LOCAL TIME
12:00 AM 31 Jul 2023
5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA – FAR (48 CFR) 53.212
(TYPE OR PRINT)
(SIGNATURE OF CONTRACTING OFFICER)
ADDENDA ARE
X
26. TOTAL AWARD AMOUNT (For Gov t. Use Only )
23.
CODE 10. THIS ACQUISITION IS
SUCH ADDRESS IN OFFER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT
BELOW IS CHECKED
TELEPHONE NO.813-786-0067
M670019. ISSUED BY
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK
M6700123P0014 01-Sep-2023
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
PATRICIA QUINONES
2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER
(TYPE OR PRINT)
30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA
27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.
X
25. ACCOUNTING AND APPROPRIATION DATA
1. REQUISITION NUMBER
20.
ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
M501693295288
ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
Waymon D. Gardner / Contracting Officer
See Schedule $457,449.84
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS: SEE SCHEDULE
.11-Jul-2023 YOUR OFFER ON SOLICITATION
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN M6700123Q0014
% FOR:SET ASIDE:UNRESTRICTED ORX
SMALL BUSINESS
17a.CONTRACTOR/ CODE 1GBS1 FACILITY
OFFEROR CODE
M67001
MARINE CORPS FIELD CONTRACTING SYS
PO BOX 8368 BLDG 316
CAMP LEJEUNE NC 28547-8368
MCS OF TAMPA, INC.
CHRIS COLLINS
8510 SUNSTATE ST
TAMPA FL 33634-1312
DFAS COLUMBUS HQ0871
USMC DAI VENDOR PAY
PO BOX 360922
COLUMBUS OH 43213-9022
18a. PAYMENT WILL BE MADE BY CODE HQ0871
RATED ORDER UNDER
DPAS (15 CFR 700)
13a. THIS CONTRACT IS A
13b. RATING
M67001CODE
SCD: C
15. DELIVER TO CODE 16. ADMINISTERED BY
SEE SCHEDULE
Net 30 Days
12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
SEE SCHEDULE
14. METHOD OF SOLICITATION
RFQ IFB RFPX
M67001MARINE CORPS FIELD CONTRACTING SYS
PATRICIA QUINONES
PO BOX 8368
CAMP LEJEUNE NC 28546
FAX:
TEL: SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
8(A)
HUBZONE SMALL
BUSINESS
SIZE STANDARD:
$34,000,000
NAICS:
811210
OFFER DATED
29. AWARD OF CONTRACT: REF.
DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND
X
EMAIL: waymon.gardner@usmc.mil
910-451-1535TEL:
31c. DATE SIGNED
22-Aug-2023
SEE SCHEDULE
SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT
24.22.21.19.
WOMEN-OWNED SMALL BUSINESS (WOSB)
ELIGIBLE UNDER THE WOMEN-OWNED
SMALL BUSINESS PROGRAM
EDWOSB
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
(CONTINUED)
PAGE 2 OF97
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
32b. SIGNATURE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
37. CHECK NUMBER
FINALPARTIALCOMPLETE
36. PAYMENT35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER
FINAL
33. SHIP NUMBER
PARTIAL
38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS
STANDARD FORM 1449 (REV. 2/2012) BACK
Prescribed by GSA – FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
SEE SCHEDULE
20.
SCHEDULE OF SUPPLIES/ SERVICES
21.
QUANTITY UNIT
22. 23.
UNIT PRICE
24.
AMOUNT
19.
ITEM NO.
M6700123P0014
Section SF 1449 - CONTINUATION SHEET
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 12 Months $38,120.82 $457,449.84 Base Period
FFP
In accordance with the PWS maintenance contract for the Telecommunications
Unified Communications (UC) System and Sub Systems (TAS), Remote
Emergency Technical Assistance (ETAS), Engineering Support, Material Services and occasional diagnostics
TO BE PAID MONTHLY IN ARREARS
FOB: Destination
PURCHASE REQUEST NUMBER: M501693295288
PSC CD: DG01
NET AMT $457,449.84
ACRN AA
CIN: M5016932952880001
$457,449.84
1001 12 Months $38,120.82 $457,449.84 OPTION Option Period 1
FFP
In accordance with the PWS maintenance contract for the Telecommunications
Unified Communications (UC) System and Sub Systems (TAS), Remote
Emergency Technical Assistance (ETAS), Engineering Support, Material Services
PSC CD: DG10
2001 12 Months $38,120.82 $457,449.84 OPTION Option Period 2
FFP
In accordance with the PWS maintenance contract for the Telecommunications
Unified Communications (UC) System and Sub Systems (TAS), Remote
Emergency Technical Assistance (ETAS), Engineering Support, Material Services
PSC CD: DG10
3001 12 Months $38,120.82 $457,449.84 OPTION Option Period 3
FFP
In accordance with the PWS maintenance contract for the Telecommunications
Unified Communications (UC) System and Sub Systems (TAS), Remote
Emergency Technical Assistance (ETAS), Engineering Support, Material Services
PSC CD: DG01
INSPECTION AND ACCEPTANCE TERMS
Supplies/services will be inspected/accepted at:
CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY
0001 Destination Government Destination Government
1001 Destination Government Destination Government
2001 Destination Government Destination Government
3001 Destination Government Destination Government
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
0001 POP 01-SEP-2023 TO
31-AUG-2024
N/A M50169 MCAS BEAUFORT
LAUREN BROOKS
795 GEIGER BLVD,
BLDG 599
MCAS BEAUFORT SC 29904
M50169
1001 POP 01-SEP-2024 TO
31-AUG-2025
N/A (SAME AS PREVIOUS LOCATION)
2001 POP 01-SEP-2025 TO
31-AUG-2026
N/A (SAME AS PREVIOUS LOCATION)
3001 POP 01-SEP-2026 TO
31-AUG-2027
N/A N/A
ACCOUNTING AND APPROPRIATION DATA
AA: 044320 017 1106 000 N 20232023 D 0000 M40169_23S1_G60000_ITSERV M50169_630623NCNF_FXVOICE M40169 257
AMOUNT: $457,449.84
ACRN CLIN/SLIN CIN AMOUNT
AA 0001 M5016932952880001 $457,449.84
PERFORMANCE WORK STATEMENT
MCAS Beaufort Telephone Network Technical Assistance and Maintenance Support Services
Introduction.
The S6 Telecommunications Operations Branch provides critical voice and data communications to the Marine
Corps Air Station Beaufort (MCASB) and Townsend Bombing Range (TBR) area and requires technical assistance and maintenance support to provide reliable service.
Scope.
This Performance Work Statement (PWS) establishes and defines the requirements for the contractor to provide technical support, repair/return of parts and on-site maintenance support as required for the Base Telephony
Network for the Marine Corps Air Station and Townsend Bombing Range area. Specifics for each line item are included below.
Places of Performance. (May require shipping to addressees at the below locations)
Supported MCASB locations and/or AOR(s):
1. Marine Corps Air Station Beaufort, Beaufort, SC
2. Townsend Bombing Range, Townsend, GA.
Requirements
1.0 INTRODUCTION.
The purpose of this contract is to provide the Telecommunications Operations Branch, S-6, MCASB with Technical
Assistance Service (TAS), / Extended Technical Assistance Services (ETAS), Return & Repair Replacement
Service, Engineering Support, Upgrades, Material Services and Remote Diagnostics Service for UC/DWDM and other ancillary equipment located aboard MCAS Beaufort and Townsend Bombing Range.
2.0 TECHNICAL REQUIREMENTS
2.1 This support agreement shall include the service requirements of Technical Assistance Service (TAS), /
Extended Technical Assistance Services (ETAS), Return & Repair Replacement, and Remote Diagnostics, Upgrades, based on the Unified Communications (UC) and Dense Wavelength Division Multiplexing (DWDM) suites including Avaya CM8 host and four remotes, Tellabs Coriant 7100 Nano, 7100E, OLAN, Callegra Callware
Messaging system, Compunetix conferencing system, CAIRS Telephony Management System (Unique
Communications), NetApp, K&R Custom Software, Micro Semi GPS clocks, Polycom, Secure Logix voice firewalls, Brocade routers and access switches, Ruckus Networks, Alpha, as noted on attached spreadsheet.
2.1.1 Core TAS/ETAS for the term of the contract.
This core TAS/ETAS support package shall provide the primary services required for day-to-day support of the
MCASB UC/DWDM systems, and all associated systems.
a. The contractor shall provide support to have the system operational 24/7 basis.
b. The contractor shall take incoming service calls.
c. The contractor shall provide initial Tier 1 support and if required Tier II and Tier III support.
d. The contractor shall open ETAS tickets with required company on service issues.
2.1.2 Unlimited Technical Assistance Support Services
a. on-site and remote maintenance
b. diagnostics
c. routine technical assistance
d. emergency technical assistance services
e. testing
f. diagnostic fault isolation
g. problem resolution
h. system restoration from the system company’s TAS facilities for the complete UC/DWDM system
i. remote support shall include but not limited to telephonic assistance, direct remote access, and on-site assistance to the switching system via secure connection as available.
2.2 Special remote terminals to allow the UC/DWDM TAS center to communicate with the system to diagnose fault conditions and recommend corrective actions.
a. Emergency TAS shall be capable of having the system operational 24 hours a day, seven days a week.
b. For those customers requiring non-service threatening support, routine TAS shall be available from 7:00 a.m. to 4:00 p.m. EST, Monday through Friday.
2.3 Repair and Replacement (R&R) of the UC and DWDM suites hardware, including disk drives, power rectifiers and inverter modules. Coverage shall include all equipment on attached parts list and associated ancillary equipment, rectifiers, inverters, voice mail components.
a. Typical turn-around time for R&R service shall be 20 business days or less.
b. During emergency situations, necessary replacements shall be shipped within 24 hours.
2.4 Software, Hardware support of the UC and DWDM suite, including security patches, software, and hardware upgrades; including the operating systems, bios, and any licenses as required by upgrading due to end of life, end of service, or systems no longer supported by the DoD USMC to maintain compliance with the USMC
MARFORCYBER guidelines. Coverage shall include all software and hardware on attached list as well as anything that has been installed because of an upgrade and associated ancillary equipment.
a. Turn-around time for routine software patching and upgrade service shall be 20 business days or less.
b. During emergency situations, necessary patches and program repairs shall be made within 24 hours.
c. Coverage shall include all software on attached list and associated ancillary equipment.
2.5 STATION LEVEL SUPPORT
2.5.1 Repair and Return of Failed Items. The contractor shall utilize all associated companies’ services to support the UC and DWDM telecommunication systems. The contractor shall closely monitor performance to ensure that quality standards are being observed; thereby providing a well-coordinated effort to ensure highly responsive Station
Level Support for all items and support equipment that comprise the UC/DWDM system installed at MCAS
Beaufort, SC.
2.5.2 Station Center Operations. The contractor shall utilize all associated companies dedicated full-time facilities for Station Level Support including the repair of all UC/DWDM and associated equipment. This support shall consist of the repair or replacement of electronic circuit packs, major subassemblies, modules, printed circuit boards, and other repairable items. The depot centers shall be fully staffed during normal duty hours and maintain on call standby coverage to handle emergency orders during all non-duty hours.
2.5.3 Emergency Requests. To meet the Government's high-priority, short lead time emergency requirements, the contractor's emergency replacement service shall ensure the system operates 24 hours a day, seven days per week, 365 days per year for the MCAS Beaufort UC/DWDM system. An emergency is defined as a critical system service outage which significantly impacts customer operations. The Government is responsible for making the final determination of an emergency. The contract will identify the point of contact that has been authorized by the
Government to request this emergency service.
2.5.4 Remote Diagnostics. The contractor shall provide remote diagnostic services for UC/DWDM systems that may occasionally experience hardware or software problems. The contractor shall provide MCAS Beaufort with the phone numbers, addresses, and POCs for the remote diagnostic facilities.
2.5.5 Scope of Remote Diagnostic Services. Remote diagnostic services shall be available for use during emergency situations when all other Government, third-party, and/or on-site contractor support have failed to correct a problem.
Emergencies shall be handled immediately. With non-emergencies, the site shall be called back to work the problem with the ETAS engineer. The contractor shall immediately investigate and resolve emergency situations that occur in the operation and maintenance of the switch systems and continue to work every such situation remotely until the problem is corrected and service is restored.
2.5.6 Remote Diagnostic Service Centers. The Remote Diagnostic Service Centers for the UC/DWDM suite and all associated ancillary equipment shall be available for the system to operate 24 hours a day, seven days per week, 365 days per year for the duration of the contract.
2.5.7 On Site Diagnostic Service. If trouble analysis remote diagnostic services or replacement of contractor supplied parts by local technical experts are unable to isolate and affect repairs, then onsite contractor support shall be required. The contractor shall provide for and assume all costs associated for travel, lodging and subsistence of any support staff required to travel to the MCAS Beaufort sites covered under this support agreement.
3.0 EQUIPMENT LIST
3.1 Hardware, Software, and Battery information is listed in Attachment 1
4.0 Government Furnished Information and Facilities
Government furnished information, such as building locations, required by the contractor for the performance of this contract will be provided with each request. All information received remains the property of the United States
Government. The Contractor may be in contact with data subject to the Privacy Act (Title 5 of U.S. Code, Section
552.a). Reports and data shall be identified and safeguarded accordingly. Agency procedures shall be followed. The
Contractor shall ensure that contractor employees assigned to this requirement are briefed annually on properly identifying and handling privacy act data/ information.
There is no requirement for Government Furnished Facilities. If vendor provides “on-site” support, access will be granted as required.
5.0 Contractor Responsibilities
The Contractor shall provide shipping as required. Government will not pay any travel expenses as part of this
PWS.
4.2 Contracting Officer’s Representative. The Contracting Officer Representatives (COR) will monitor performance to ensure services are received and performed in a satisfactory manner. COR: To be provided at the time of award.
4.3 Quality Control.
The contractor shall establish and maintain a complete quality control program for the performance requirements of this contract. The Contracting Officer’s Representative will evaluate the contractor’s performance based on the
PWS.
5.0 Quality Assurance Surveillance Plan (QASP)
5.1 Purpose. This Quality Assurance Surveillance Plan (QASP) has been developed to provide the standard of surveillance for Telephony Network Maintenance Services. The Contracting Officer (KO) will be appointed at the time of award and COR Contact information will be provided. The COR will also serve as the Quality Assurance
Evaluator (QAE) and will use this QASP to ensure the standards of the contract are being met. The COR/QAE will be referred to as the COR throughout this QASP.
5.2 Performance Standards. The QASP provides a systematic method to evaluate the service the Contractor is required to furnish. The COR will assess the Contractor’s performance to ensure the Contractor is performing up to the specified standards. The standards for this Performance Work Statement (PWS) are stated in the Level of Effort
Requirements Summary (PRS) included in this QASP. The standards for this procurement are subjective since specific metric-driven standards are not appropriate.
5.3 Management and Oversight. The QASP is based on the premise that the Contractor and not the Government, is responsible for the management and any Quality Control action required to meet the terms of the contract. Good management and use of an adequate Quality Control Plan will allow the Contractor to operate within specific performance requirements. QASPs are designed to be objective, fair, and consistent in evaluating Contractor performance against the provided standards.
5.4 Acceptable Quality Levels (AQLs). AQLs have been established in the summary and provide performance standards that the Contractor will meet in performing the contract. If the contractor meets the required AQL, it will be paid the monthly amount agreed upon in the contract. In the event the Contractor does not meet the established
AQLs, the KO has the right to exercise the negative incentives stated in this QASP.
5.5 Primary Method of Surveillance/Evaluation. The COR will evaluate the contractor’s performance using one or more of the following surveillance methods:
a. 100% Inspection: Inspection where specified characteristics of performance are examined.
and tested to determine conformance with defined requirements in the Performance Work Statement (PWS).
b. Random Inspection: Sampling method in which each unit of the population has an equal chance of being selected.
c. Customer Surveys and Feedback: A review method where customers and end users are surveyed to provide input on specific service levels.
5.6 Negative Incentives If any of the performance requirements do not meet the AQL set in the PRS table, the COR shall document the discrepancy(s) and shall notify the Contractor promptly, and the KO, monthly, for appropriate action. When the performance is below the AQL standard, the Government may implement negative incentives that include increased surveillance, reduction in contract price, and/or decision not to exercise next option.
5.7 Notification. The COR will notify the KO, in writing, of unacceptable quality levels. The KO will promptly provide written notification of discrepancies monthly, or immediately if the situation significantly affects the well-being of the project. The Contractor will be given the opportunity to respond, in writing, to each discrepancy.
5.8 Response. The Contractor shall provide a written response to the cause and the corrective action to prevent recurrence within ten (10) working days after receipt of the KO’s notification. The Contractor should cite specific quality assurance program procedures or new procedures instituted to prevent recurrence.
5.9 Ratings. The following criteria will be used for performance evaluations: Exceptional, Satisfactory, Marginal, or Unsatisfactory. Upward or downward arrows may be used to indicate an improving or worsening trend insufficient to change to the assessment status.
a. Exceptional. Indicates performance clearly exceeds contractual requirements. The area of evaluation may contain a few minor problems for which corrective action appears highly effective.
b. Satisfactory. Indicates performance clearly meets contractual requirements. The area of evaluation contains some minor problems for which the corrective actions appear satisfactory.
c. Marginal. Indicates performance meets contractual requirements. The area of evaluation contains one or more serious problems for which corrective actions have not yet been identified, appear only marginally effective, or have not been fully implemented.
d. Unsatisfactory. Indicates the contractor is in danger of not being able to satisfy contractual requirements and recovery is not likely in a timely manner. The area of evaluation contains one or more serious problems for which the corrective actions appear ineffective.
5.10 Documentation. Documentation used and referenced to perform surveillance will consist of monthly reports, contractor plans and procedures, schedules, customer feedback and contract data requirements.
a. Recording Observations. The COR shall use Surveillance Logs to record information on scheduled observations and deficiencies noted. Each observation is recorded on the log. The documents then become a formal record for reference. The contractor is to be told each time that a deficiency is found during scheduled observations. The COR makes a notation on the Surveillance Log of the date and time the deficiency was discovered, then, the COR asks a contractor site manager to initial the notation, documenting notification of the deficiency only.
b. Potential Unacceptable Performance. The COR must identify the specific service that is unacceptable and the possible causes, and ask a few questions which if answered, will probably pinpoint the source of the problem.
c. Documenting Unacceptable Performance. The COR must attempt to resolve the problem with the contractor. The original log and the attempted solution (along with an evaluation of results) are forwarded to the Contracting Officer through the COR.
Based on the severity of the discrepancy and the success of the solution, the COR will notify the KO. The contractor shall complete a response to the unacceptable evaluation if requested by the KO or by its own choice.
5.11 Taking Action.
a. The COR may evaluate the contractor’s performance and document any non-compliance, but only the KO may act against the contractor for an unacceptable rating.
b. When the contractor’s performance is unacceptable and a formal action is indicated, the COR will determine what action is appropriate for the specific circumstances and make a recommendation to the KO.
5.12 Documentation. The COR retains a copy of all inspection schedules and surveillance activity logs while the contract and forwards them for inclusion in the contract file at the end of the surveillance period. However, when a specific service becomes unsatisfactory during a surveillance period, the inspection documentation supporting the contract discrepancy report is forwarded to the KO.
5.14 Performance Requirements Summary. The performance standards for this PWS are stated in the
Performance Requirements Summary (PRS) below.
The contractor shall determine and resolve trouble shooting remote diagnostic services problems within 1 hours of scheduled time. Corrective actions will be due within three days.
The contractor shall provide deliverables in accordance with schedule.
The contractor shall demonstrate effectiveness of improvements/corrective actions in response to customer complaints within 24 hours of scheduled time and provide a plan and corrective action within three days.
Paragraph in PWS
Acceptable
Quality Level
Acceptable
Performance Level
(APL)
Inspection Method
Incentives
2.1
Timeliness
Quality of Service
Performance
85% of support for system to operate
24/7
Random and Monthly
Inspection of provided services
Exercise Option
2.3
Performance
85% of repairs turnaround time of
20 business days or less.
85% of replacements
Random and Monthly shipped within 24
Hours
2.5.1 system to operate
24/7
2.5.5 Timeliness
the system to operate 24/7
6.0 BASE ACCESS INSTRUCTIONS
Base Access. Contractors and/or delivery drivers, must have in their possession: the contract number, delivery/service address, and sponsor’s contact information to gain initial access to the base.
Sponsor: Eaton.Owen
Phone Number: 843-228-7556
Email: Eaton.Owen@usmc.mil
- Contractors must be registered in the Defense Biometrics Identification System (DBIDS). It is the Contractor’s responsibility to ensure all their employees and/or subcontractors are properly registered within DBIDS.
- DBIDS credentials will be valid for the duration of your contract, not to exceed three years; however, re-vetting of individuals' information will occur each year.
- Contractors requiring access for over 60 days will receive a credential valid for up to one year.
- Contractors requiring access for less than 60 days will receive a temporary paper pass.
- Contractor Common Access Card (CAC) Eligibility: Contractor personnel authorized CACs are exempt from
DBIDS enrollment.
- If you have questions regarding base access, Contractor CACs, or DBIDS requirements, contact the Contractor
Vetting Office (CVO). The CVO is in Bldg. 818 adjacent to the Camp Lejeune Main Gate on Holcomb Blvd, just off NC Highway 24. The CVO is open Monday through Friday from 6 a.m. to 2 p.m. and closed on weekends and holidays.
Contractor Vetting Office - Appointments: 910-451-5977
Contractor Vetting Office - Questions: 910-451-0284/0289.
Vetting Office Email: lejeunecontractorvetting@usmc.mil
DBIDS email: https://dbids-global-enroll.dmdc.mil/preenrollui/#!/
- Contractors will report to the Contractor Vetting Office (CVO) to confirm their access requirements, undergo a background check, and receive their credential/pass.
PLEASE NOTE: Individuals with active warrants may be subject to arrest on the spot.
**The Government will not be responsible for any contractor access delays. Delays that may result from inadequate planning are strictly the responsibility of the contractor.
7.0 UNAUTHORIZED WORK PERFORMANCE
mailto:lejeunecontractorvetting@usmc.mil https://dbids-global-enroll.dmdc.mil/preenrollui/#!/
The Contractor shall not perform work that deviates from contract requirements and Performance Work Statement.
If the Contractor deviates from contract requirements and PWS without approval of the CONTRACT
ADMINISTRATOR/CONTRACTING OFFICER, such deviation shall be at the risk of the Contractor and any cost related thereto shall be borne by the Contractor.
8.0 KICKOFF MEETING
The kickoff meeting between the Contracting Officer, the COR, and the Contractor shall be by conference call within 5 days after the contract award date. The award-winning Contractor must provide 60% of Contractor employees within seven days after the award contract and the remaining Contractor employees must be provided within twenty-one days after the award contract. Contractor employee resumes must be delivered to the COR within seven days after the contract award. Critical services of 60% must be performed within the first seven days after contract award. All service tasks must be performed completely by the contractor in accordance with the
Performance Work Statement by the end of the twenty first day after the contract award.
**The Government will not be responsible for any contractor access delays. Delays that may result from inadequate planning are strictly the responsibility of the Contractor.
DEVICE LIST
HWC
I #
OEM Model Baseline
Version
OEM Serial # Description
1 Brocade BR-MLXE-4-MR-M-AC 6.0.0c BGD3813N003 L3 routing switch providing access to the network for all VOIP devices
2 Brocade BR-MLX-10Gx4-X 6.0.0c BMY3236M02D L3 routing switch providing access to the network for all VOIP devices
3 Brocade BR-MLX-1GFx24-X 6.0.0c BND3251M008 L3 routing switch providing access to the network for all VOIP devices
4 Brocade BR-MLX-MR2-M 6.0.0c BVP3202N036 L3 routing switch providing access to the network for all VOIP devices
5 Brocade BR-MLX-MR2-M 6.0.0c BVP3202N043 L3 routing switch providing access to the network for all VOIP devices
6 Brocade BR-MLXE-4-MR-M-AC 6.0.0c BGD3813N001 L3 routing switch providing access to the network for all VOIP devices
7 Brocade BR-MLX-10Gx4-X 6.0.0c BMY3236M028 L3 routing switch providing access to the network for all VOIP devices
8 Brocade BR-MLX-1GFx24-X 6.0.0c BND3251M004 L3 routing switch providing access to the network for all VOIP devices
9 Brocade BR-MLX-MR2-M 6.0.0c BVP3202N016 L3 routing switch providing access to the network for all VOIP devices
10 Brocade BR-MLX-MR2-M 6.0.0c BVP3202N00K L3 routing switch providing access to the network for all VOIP devices
11 Brocade ICX 7450-48 8.0.40b CYQ3349M038 L2 switch providing access to the network for all VOIP devices
12 Brocade ICX7400-4X1GF 8.0.40b CYY3340M00H L2 switch providing access to the network for all VOIP devices
13 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M389 L2 switch providing access to the network for all VOIP devices
14 Brocade ICX 7450-48 8.0.40b CYQ3349M03A L2 switch providing access to the network for all VOIP devices
15 Brocade ICX7400-4X1GF 8.0.40b CYY3340M04E L2 switch providing access to the network for all VOIP devices
16 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M3MK L2 switch providing access to the network for all VOIP devices
17 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M3E3 L2 switch providing access to the network for all VOIP devices
18 Brocade ICX 7450-24 8.0.40b CYT3308N002 L2 switch providing access to the network for all VOIP devices
19 Brocade ICX7400-4X1GF 8.0.40b CYY3303N02A L2 switch providing access to the network for all VOIP devices
20 Brocade ICX7400-1X40GQ 8.0.40b CYX3315N03G L2 switch providing access to the network for all VOIP devices
21 Brocade ICX 7450-24 8.0.40b CYT3310N011 L2 switch providing access
22 Brocade ICX7400-4X1GF 8.0.40b CYY3340M014 L2 switch to the network for all VOIP devices
23 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M2ZG L2 switch providing access to the network for all VOIP devices
24 Brocade ICX 7450-24 8.0.40b CYT3307N01R L2 switch providing access to the network for all VOIP devices
25 Brocade ICX7400-4X1GF 8.0.40b CYY3340M032 L2 switch providing access to the network for all VOIP devices
26 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M3DM L2 switch providing access to the network for all VOIP devices
27 Brocade ICX 7450-24 8.0.40b CYT3307N010 L2 switch providing access to the network for all VOIP devices
28 Brocade ICX7400-4X1GF 8.0.40b CYY3340M01M L2 switch providing access to the network for all VOIP devices
29 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M320 L2 switch providing access to the network for all VOIP devices
30 Brocade ICX 7450-24 8.0.40b CYT3307N02L L2 switch providing access to the network for all VOIP devices
31 Brocade ICX7400-4X1GF 8.0.40b CYY3340M01Z L2 switch providing access to the network for all VOIP devices
32 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M362 L2 switch providing access to the network for all VOIP devices
33 Brocade ICX 7450-24 8.0.40b CYT3307N00F L2 switch providing access to the network for all VOIP devices
34 Brocade ICX7400-4X1GF 8.0.40b CYY3340M04A L2 switch providing access to the network for all VOIP devices
35 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M37D L2 switch
36 Brocade ICX 7450-24 8.0.40b CYT3307N00W L2 switch providing access to the network for all VOIP devices
37 Brocade ICX7400-4X1GF 8.0.40b CYY3336M04D L2 switch providing access to the network for all VOIP devices
38 Brocade ICX7400-1X40GQ 8.0.40b CYX3352M3FE L2 switch providing access to the network for all VOIP devices
39 Brocade ICX 7450-24 8.0.40b CYT3302N03X L2 switch providing access to the network for all VOIP devices
40 Brocade ICX 7450-24 8.0.40b CYT3333N02D L2 switch providing access to the network for all VOIP devices
41 Brocade ICX 7450-48 8.0.40b CYQ3349M02W L2 switch providing access to the network for all VOIP devices
42 Brocade ICX7400-4X1GF 8.0.40b CYY3336M04F L2 switch providing access to the network for all VOIP devices
43 Brocade ICX7400-1X40GQ 8.0.40b CYX3325N00H L2 switch providing access to the network for all VOIP devices
44 Dell Latitude 5414 Rugged Window s 10 Pro
GHH0QSG2 Maintenance
Laptop
45 Dell Latitude 5414 Rugged Window s 10 Pro
DXHMG92 Maintenance
Laptop
46 Dell Latitude 3580 Window s 10 Pro
76Q3MJ2 Maintenance
Laptop
47 Dell Optiplex 7040 Window s 10 Pro
14D0KH2 Maintenance
Desktop
48 Dell Optiplex 7040 Window s 10 Pro
14CYJH2 Maintenance
Desktop
49 Dell Optiplex 7040 Window s 10 Pro
14CZJH2 Maintenance
Desktop
50 Dell 17-CMPUX-016 Compunetix SSE
51 Dell 17-CMPUX-015 Compunetix BSS
52 Contex Summit 00-892X-0192-DAST Contex Summit
53 Dell PowerEdge R330 Server HM5YHH2 ETM Database
Server
54 Dell PowerEdge R330 Server HM5ZHH2 ETM
Management
Server
55 Secure Logix ETM-3200-CHS-AC 3200-A-R-205169 ETM Voice
Firewall
Appliance
56 Secure Logix ETM-1000-CHS-AC 1024CR02133 ETM Voice
Firewall
Appliance
57 Secure Logix ETM-3200-CHS-AC 6170652314 ETM Voice
Firewall
Appliance
58 Microsemi ATS 6580 U68795 GPS Timing
Source
59 Microsemi ATS 6580 U68796 GPS Timing
Source
60 Dell PowerEdge R630 H7WZHH2 Brocade Network
Advisor (BNA)
61 NetApps FAS2620,12x4TB 721733000027 NetApp Backup
62 NetApps FAS2620,12x4TB 721733000028 NetApp Backup
63 Dell PowerEdge R330 HMSWHH2 Voice File Server
64 Dell PowerEdge R630 H7X0JH2 Panorama
65 Dell PowerEdge R330 HMSCJH2 Syslog
66 Dell NX430 75SNKH2 Callware
Voicemail Server
67 Oracle Sparc Solaris
AK00103304 7194 Server
68 Asentria T850 850003666 Teleboss Remote
Access Unit
69 Asentria T850 850019016 Teleboss Remote
Access Unit
70 Asentria T850 850003663 Teleboss Remote
Access Unit
71 Asentria T850 850003664 Teleboss Remote
Access Unit
72 Asentria T850 850003667 Teleboss Remote
Access Unit
73 Belkin 7116567 Kernel Based
Virtual Machine
(KVM)
74 Belkin 7116569 Kernel Based
Virtual Machine
(KVM)
75 Belkin 7113702 Kernel Based
Virtual Machine
(KVM)
76 Belkin 7125190 Kernel Based
Virtual Machine
(KVM)
77 Belkin 7125193 Kernel Based
Virtual Machine
(KVM)
78 Belkin 7125191 Kernel Based
Virtual Machine
(KVM)
79 Dell PowerEdge R330 67K2JH2 ION Remote
Access Server
80 ION SA5600 ION Routing
Device
81 ION SA5600 6170652314 ION Access
Device
82 Avaya HP DL360 G9 AVP
Host 0
CM7
v7.0.1
17AN24200047 Local Session
Controller
83 Avaya HP DL360 G9 CM
Core 0
CM7
v7.0.1
Local Session
Controller
84 Avaya HP DL360 G9 CM
Core 0
OOB
CM7
v7.0.1
Local Session
Controller
85 Avaya HP DL360 G9 AVP
Host 1
CM7
v7.0.1
16AN28200019 Local Session
Controller
86 Avaya HP DL360 G9 CM
Core 1
CM7
v7.0.1
Local Session
Controller
87 Avaya HP DL360 G9 CM
Core 1
OOB
CM7
v7.0.1
Local Session
Controller
88 Avaya HP DL360 G8 Avaya
Aura AE
Services
Release
6.3.3
16AN27500025 Local Session
Controller
89 Avaya HP DL360 G8 Avaya
Aura AE
Services
Release
6.3.3
Local Session
Controller
90 Avaya HP DL360 G8 Avaya
Aura AE
Services
Release
6.3.3
Local Session
Controller
91 Avaya HP DL360 G8 Avaya
Aura AE
Services
16AN27500040 Local Session
Controller
Release
6.3.3
92 Avaya HP DL360 G8 Avaya
Aura AE
Services
Release
6.3.3
Local Session
Controller
93 Avaya HP DL360 G8 Avaya
Aura AE
Services
Release
6.3.3
Local Session
Controller
94 Avaya HP DL360 G8 AVP
Host 0
CM7
v7.0.1
16AN33400013 Local Session
Controller
95 Avaya HP DL360 G8 CMSUR
Core 0
CM7
v7.0.1
Local Session
Controller
96 Avaya HP DL360 G8 CMSUR
Core 0
OOB
CM7
v7.0.1
Local Session
Controller
97 Avaya HP DL360 G8 AVP
Host 1
CM7
v7.0.1
16AN33400017 Local Session
Controller
98 Avaya HP DL360 G8 CMSUR
Core 1
CM7
v7.0.1
Local Session
Controller
99 Avaya HP DL360 G8 CMSUR
Core 1
OOB
CM7
v7.0.1
Local Session
Controller
100 Avaya HP DL360 G8 AVP
Host
CM7
v7.0.1
16AN33400014 Local Session
Controller
101 Avaya HP DL360 G8 CMSUR
Core
CM7
v7.0.1
Local Session
Controller
102 Avaya HP DL360 G8 CMSUR
Core
OOB
CM7
v7.0.1
Local Session
Controller
103 Avaya HP DL360 G8 AVP
Host
CM7
v7.0.1
16AN33500007 Local Session
Controller
104 Avaya HP DL360 G8 CMSUR
Core
CM7
v7.0.1
Local Session
Controller
105 Avaya HP DL360 G8 CMSUR
Core
OOB
CM7
v7.0.1
Local Session
Controller
106 Avaya HP DL360 G8 AVP
Host
CM7
v7.0.1
16AN52500050 Local Session
Controller
107 Avaya HP DL360 G8 CMSUR
Core
CM7
v7.0.1
Local Session
Controller
108 Avaya HP DL360 G8 CMSUR
Core
OOB
CM7
v7.0.1
Local Session
Controller
111 Avaya G450 Gateway 1 16R025640337 Analog Voice
Gateway
Avaya PS4504 15BE39400798
Avaya PS4504 16DT16397305
Avaya MB450 16R025639541
Avaya MM710B PRI 15R029300087
Avaya MM716 ANALOG 18R016400050
Avaya MM716 ANALOG 18R016400078
Avaya MM716 ANALOG 18R016400024
Avaya MM716 ANALOG 18R016400091
Avaya MM716 ANALOG 18R016400023
Avaya MM717 DCP 15R025600099
Avaya MM711 HV46 16R043600020
112 Avaya G450 Gateway 2 15R047481852 Analog Voice
Gateway
Avaya PS4504 15BE25200353
Avaya PS4504 15BE30300350
Avaya MB450 15R047481618
Avaya MM710B PRI 15R029300009
Avaya MM716 ANALOG 18R016400074
Avaya MM716 ANALOG 18R016400058
Avaya MM716 ANALOG 18R016400043
Avaya MM716 ANALOG 18R016400004
Avaya MM716 ANALOG 18R016400083
Avaya MM717 DCP 15R025600130
Avaya VACANT
113 Avaya G450 Gateway 3 16R024442338 Analog Voice
Gateway
Avaya PS4504 15BE25200527
Avaya PS4504 16DT16397369
Avaya MB450 16R024442188
Avaya MM710B PRI 15R029300033
Avaya MM716 ANALOG 18R016400079
Avaya MM716 ANALOG 18R016400060
Avaya MM716 ANALOG 18R016400080
Avaya MM716 ANALOG 18R016400033
Avaya MM716 ANALOG 18R016400029
Avaya VACANT
Avaya VACANT
114 Avaya G450 Gateway 4 16R024442375 Analog Voice
Gateway
Avaya PS4504 15BE25200527
Avaya PS4504 16DT16397289
Avaya MB450 16R024442261
Avaya MM710B PRI 15R029300001
Avaya MM716 ANALOG 18R016400056
Avaya MM716 ANALOG 18R016400100
Avaya MM716 ANALOG 18R016400002
Avaya MM716 ANALOG 18R016400090
Avaya MM716 ANALOG 18R016400010
Avaya VACANT
Avaya VACANT
115 Avaya G450 Gateway 5 16R025442305 Analog Voice
Gateway
Avaya PS4504 17BE01500784
Avaya PS4504 16DT16397374
Avaya MB450 16R025442227
Avaya MM710B PRI 15R029300074
Avaya MM716 ANALOG 18R016400084
Avaya MM716 ANALOG 18R016400088
Avaya MM716 ANALOG 18R016400059
Avaya MM716 ANALOG 18R016400102
Avaya MM716 ANALOG 18R016400099
Avaya VACANT
116 Avaya G450 Gateway 6 16R017225569 Analog Voice
Gateway
Avaya PS4504 17BE01500789
Avaya PS4504 16BE05500264
Avaya MB450 16R016221283
Avaya MM710B PRI 15R029300062
Avaya MM716 ANALOG 18R016400064
Avaya MM716 ANALOG 18R016400076
Avaya MM716 ANALOG 18R016400075
Avaya MM716 ANALOG 18R016400082
Avaya MM716 ANALOG 18R016400034
Avaya VACANT
Avaya VACANT
117 Avaya G450 Gateway 7 16R025442291 Analog Voice
Gateway
Avaya PS4504 17BE01500745
Avaya PS4504 16DT16397271
Avaya MB450 16R025442273
Avaya MM710B PRI 15R029300088
Avaya MM716 ANALOG 18R016400101
Avaya MM716 ANALOG 18R016400009
Avaya MM716 ANALOG 18R016400089
Avaya MM716 ANALOG 18R016400061
Avaya MM716 ANALOG 18R016400008
Avaya VACANT
Avaya VACANT
118 Avaya G450 Gateway 8 16R025640149 Analog Voice
Gateway
Avaya PS4504 16BE25100707
Avaya PS4504 16DT16397313
Avaya MB450 16R025639542
Avaya MM710B PRI 15R017500168
Avaya MM716 ANALOG 18R013600025
Avaya MM716 ANALOG 18R013600080
Avaya MM716 ANALOG 18R013600005
Avaya MM716 ANALOG 18R013600067
Avaya MM716 ANALOG 18R016400035
Avaya VACANT
Avaya VACANT
119 Avaya G450 Gateway 9 16R025640249 Analog Voice
Gateway
Avaya PS4504 15BE25200478
Avaya PS4504 16DT16397317
Avaya MB450 16R025242036
Avaya MM710B PRI 15R029300032
Avaya MM716 ANALOG 18R013600006
Avaya MM716 ANALOG 18R013600069
Avaya MM716 ANALOG 18R013600074
Avaya MM716 ANALOG 18R013600043
Avaya MM716 ANALOG 18R013600058
Avaya VACANT
Avaya VACANT
120 Avaya G450 Gateway 10 16R024442318 Analog Voice
Gateway
Avaya PS4504 15BE25201705
Avaya PS4504 16DT16397285
Avaya MB450 16R024442267
Avaya MM710B PRI 15R029300103
Avaya MM716 ANALOG 18R013600056
Avaya MM716 ANALOG 18R013600073
Avaya MM716 ANALOG 18R013600047
Avaya MM716 ANALOG 18R013600060
Avaya MM716 ANALOG 18R013600072
Avaya VACANT
Avaya VACANT
121 Avaya G450 Gateway 11 16R025640112 Analog Voice
Gateway
Avaya PS4504 15BE25200705
Avaya PS4504 16DT16397362
Avaya MB450 16R025442256
Avaya MM716 ANALOG 18R013600065
Avaya MM716 ANALOG 18R013600002
Avaya MM716 ANALOG 18R013600064
Avaya MM716 ANALOG 18R013600071
Avaya MM716 ANALOG 18R013600007
Avaya MM716 ANALOG 18R013600075
Avaya VACANT
Avaya VACANT
122 Avaya G450 Gateway 12 16R024640414 Analog Voice
Gateway
Avaya PS4504 15BE25200697
Avaya PS4504 16DT16397281
Avaya MB450 16R024639537
Avaya MM716 ANALOG 17R030200126
Avaya MM716 ANALOG 17R046600192
Avaya MM716 ANALOG 17R046600391
Avaya MM716 ANALOG 17R046600288
Avaya MM716 ANALOG 17R046600287
Avaya MM716 ANALOG 17R046600354
Avaya VACANT
Avaya VACANT
123 Avaya G450 Gateway 13 16R024442353 Analog Voice
Gateway
Avaya PS4504 15BE25200600
Avaya PS4504 16DT16397272
Avaya MB450 16R024442236
Avaya MM716 ANALOG 18R016400063
Avaya MM716 ANALOG 17R046600193
Avaya MM716 ANALOG 17R046600194
Avaya MM716 ANALOG 18R016400073
Avaya MM716 ANALOG 17R046600343
Avaya MM716 ANALOG 17R025500146
Avaya VACANT
Avaya VACANT
124 Avaya G450 Gateway 14 16R024442314 Analog Voice
Gateway
Avaya PS4504 17BE01500364
Avaya PS4504 16DT16397370
Avaya MB450 16R024242031
Avaya MM716 ANALOG 18R016400077
Avaya MM716 ANALOG 18R016400081
Avaya MM716 ANALOG 17R025500051
Avaya MM716 ANALOG 18R016400036
Avaya MM716 ANALOG 17R046600304
Avaya MM716 ANALOG 18R016400093
Avaya VACANT
Avaya VACANT
125 Avaya G450 Gateway 15 16R024442371 Analog Voice
Gateway
Avaya PS4504 16BE25101069
Avaya PS4504 16DT16397302
Avaya MB450 16R024442199
Avaya MM716 ANALOG 17R025500052
Avaya MM716 ANALOG 18R016400001
Avaya MM716 ANALOG 18R016400094
Avaya MM716 ANALOG 18R016400086
Avaya MM716 ANALOG 18R016400049
Avaya MM716 ANALOG 18R016400066
Avaya VACANT
Avaya VACANT
126 Avaya G450 Gateway 16 16R025639979 Analog Voice
Gateway
Avaya PS4504 17BE01500743
Avaya PS4504 16DT16397249
Avaya MB450 16R025442254
Avaya MM716 ANALOG 18R016400092
Avaya MM716 ANALOG 18R016400085
Avaya MM716 ANALOG 18R016400026
Avaya MM716 ANALOG 18R016400021
Avaya MM716 ANALOG 18R016400022
Avaya MM716 ANALOG 18R016400087
Avaya VACANT
Avaya VACANT
127 Avaya G450 Gateway 17 16R024442323 Analog Voice
Gateway
Avaya PS4504 17BE01500781
Avaya PS4504 16DT16397366
Avaya MB450 16R024242122
Avaya MM716 ANALOG 18R016400052
Avaya MM716 ANALOG 18R016400011
Avaya MM716 ANALOG 18R016400025
Avaya MM716 ANALOG 18R016400018
Avaya MM716 ANALOG 18R016400020
Avaya MM716 ANALOG 18R016400037
Avaya VACANT
Avaya VACANT
128 Avaya G450 Gateway 18 16R025640111 Analog Voice
Gateway
Avaya PS4504 15BE25200518
Avaya PS4504 16DT16397309
Avaya MB450 16R025242088
Avaya MM716 ANALOG 17R046600215
Avaya MM716 ANALOG 17R046600221
Avaya MM716 ANALOG 17R046600172
Avaya MM716 ANALOG 17R046600173
Avaya MM716 ANALOG 18R016400067
Avaya MM716 ANALOG 17R046600137
129 Avaya G450 Gateway 19 16R024442303 Analog Voice
Gateway
Avaya PS4504 15BE39400577
Avaya PS4504 16DT16397373
Avaya MB450 16R024442197
Avaya MM716 ANALOG 17R046600185
Avaya MM716 ANALOG 18R016400055
Avaya MM716 ANALOG 17R046600188
Avaya MM716 ANALOG 18R016400065
Avaya MM716 ANALOG 18R016400053
Avaya MM716 ANALOG 17R046600183
Avaya VACANT
Avaya MM710B PRI 16R036600214
130 Avaya G450 Gateway 20 16R025640408 Analog Voice
Gateway
Avaya PS4504 15BE25200736
Avaya PS4504 17BE14600592
Avaya MB450 16R025442189
Avaya MM716 ANALOG 17R046600238
Avaya MM716 ANALOG 17R046600307
Avaya MM716 ANALOG 17R046600176
Avaya MM716 ANALOG 17R046600211
Avaya MM716 ANALOG 17R046600239
Avaya MM716 ANALOG 17R046600218
Avaya VACANT
Avaya MM710B PRI 16R036600204
131 Avaya G450 Gateway 21 16R025640415 Analog Voice
Gateway
Avaya PS4504 15BE25200199
Avaya PS4504 16DT16397253
Avaya MB450 16R025442277
Avaya MM716 ANALOG 17R046600217
Avaya MM716 ANALOG 17R046600236
Avaya MM710B PRI 15R029300040
Avaya MM710B PRI 15R029300111
Avaya MM716 ANALOG 17R046600260
Avaya MM716 ANALOG 17R046600184
Avaya VACANT
Avaya VACANT
132 Avaya G450 Gateway 22 16R024442368 Analog Voice
Avaya PS4504 15BE25200571
Avaya PS4504 16DT16397304
Avaya MB450 16R024442282
Avaya MM716 ANALOG 17R046600213
Avaya MM716 ANALOG 17R046600171
Avaya MM716 ANALOG 17R046600213
Avaya MM710B PRI 15R029300116
Avaya MM716 ANALOG 17R046600170
Avaya MM716 ANALOG 17R046600185
Avaya VACANT
Avaya VACANT
133 Avaya G450 Gateway 23 15R020571207 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 15DT07384755
Avaya MB450 16R047463892
Avaya MM710B PRI 15R029300049
Avaya MM710B PRI 15R029300006
Avaya MM716 ANALOG 17R046600182
Avaya MM716 ANALOG 17R046600257
Avaya MM716 ANALOG 18R016400062
Avaya MM716 ANALOG 17R046600032
Avaya VACANT
Avaya VACANT
134 Avaya G450 Gateway 24 15R048481730 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 15DT2739402
Avaya MB450 15R048481599
Avaya MM710B PRI 15R029300013
Avaya MM710B PRI 15R029300034
Avaya MM716 ANALOG 17R046600200
Avaya MM716 ANALOG 18R016400003
Avaya MM716 ANALOG 17R046600426
Avaya VACANT
Avaya VACANT
Avaya VACANT
135 Avaya G450 Gateway 25 16R047463968 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16DT18397796
Avaya MB450 15R019575259
Avaya MM716 ANALOG 17R046600275
Avaya MM716 ANALOG 17R046600404
Avaya MM716 ANALOG 18R016400054
Avaya VACANT
Avaya VACANT
Avaya VACANT
136 Avaya G450 Gateway 26 16R047362891 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16BE25100320
Avaya MB450 16R047463895
Avaya MM716 ANALOG 17R046600174
Avaya MM716 ANALOG 17R046600187
Avaya MM716 ANALOG 17R025500152
Avaya MM716 ANALOG 18R016400030
Avaya MM716 ANALOG 17R025500046
Avaya VACANT
Avaya VACANT
Avaya VACANT
137 Avaya G450 Gateway 27 15R020342761 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 15DT07384380
Avaya MB450 15R019573554
Avaya MM716 ANALOG 17R025500151
Avaya MM716 ANALOG 17R025500056
Avaya MM716 ANALOG 17R025500048
Avaya MM716 ANALOG 17R025500010
Avaya MM716 ANALOG 17R025500009
Avaya VACANT
Avaya VACANT
Avaya VACANT
138 Avaya G450 Gateway 28 16R047463986 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16BE25100524
Avaya MB450 16R047463858
Avaya MM716 ANALOG 17R025500150
Avaya MM716 ANALOG 18R016400012
Avaya MM716 ANALOG 17R025500018
Avaya MM716 ANALOG 17R025500019
Avaya MM716 ANALOG 17R046600214
Avaya MM716 ANALOG 18R016400095
Avaya VACANT
Avaya VACANT
139 Avaya G450 Gateway 29 16R017225457 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 15BE44400167
Avaya MB450 16R018225148
Avaya MM716 ANALOG 17R025500026
Avaya MM716 ANALOG 17R025500025
Avaya MM716 ANALOG 17R025500101
Avaya MM716 ANALOG 17R046600189
Avaya MM716 ANALOG 17R025500021
Avaya MM716 ANALOG 17R046600222
Avaya VACANT
Avaya VACANT
140 Avaya G450 Gateway 30 16R025640104 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16DT16397336
Avaya MB450 16R025442244
Avaya MM716 ANALOG 18R016400028
Avaya MM716 ANALOG 18R016400040
Avaya MM716 ANALOG 18R016400097
Avaya MM716 ANALOG 17R046600175
Avaya MM716 ANALOG 18R016400068
Avaya MM716 ANALOG 18R016400027
Avaya VACANT
Avaya VACANT
141 Avaya G450 Gateway 31 16R024442363 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16DT16397274
Avaya MB450 16R024442222
Avaya MM716 ANALOG 18R016400007
Avaya MM716 ANALOG 17R046600220
Avaya MM716 ANALOG 18R016400098
Avaya MM716 ANALOG 18R016400015
Avaya MM716 ANALOG 18R016400005
Avaya MM716 ANALOG 18R016400013
142 Avaya G450 Gateway 32 16R047464114 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16BE25100619
Avaya MB450 16R047463869
Avaya MM716 ANALOG 18R013600017
Avaya MM716 ANALOG 18R013600016
Avaya MM716 ANALOG 18R016400012
Avaya MM716 ANALOG 18R013600049
Avaya MM716 ANALOG 18R013600050
Avaya MM716 ANALOG 18R013600022
Avaya VACANT
Avaya VACANT
143 Avaya G450 Gateway 33 15R048481992 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 15DT27394025
Avaya MB450 15R048481588
Avaya MM716 ANALOG 17R025500055
Avaya MM716 ANALOG 17R025500054
Avaya MM716 ANALOG 17R025500044
Avaya MM716 ANALOG 17R025500053
Avaya MM716 ANALOG 17RO25500050
Avaya VACANT
Avaya VACANT
Avaya VACANT
144 Avaya G450 Gateway 34 15R020571205 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 15DT07384750
Avaya MB450 15R019573422
Avaya MM716 ANALOG 17R025500028
Avaya MM716 ANALOG 17R025500022
Avaya MM716 ANALOG 17R025500007
Avaya MM716 ANALOG 17R025500108
Avaya MM716 ANALOG 17R025500045
Avaya VACANT
Avaya VACANT
Avaya VACANT
145 Avaya G450 Gateway 35 16R025640410 Analog Voice
Avaya PS4504
Avaya PS4504 16DT16397202
Avaya MB450 16R25442278
Avaya MM716 ANALOG 17R025500012
Avaya MM716 ANALOG 17R025500013
Avaya MM716 ANALOG 17R025500023
Avaya MM716 ANALOG 17R025500014
Avaya MM716 ANALOG 17R025500015
Avaya VACANT
Avaya VACANT
Avaya VACANT
146 Avaya G450 Gateway 36 16R024442308 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16DT16397294
Avaya MB450 16R024442245
Avaya MM716 ANALOG 18R016400006
Avaya MM716 ANALOG 17R025500047
Avaya MM716 ANALOG 17R025500049
Avaya MM716 ANALOG 17R025500008
Avaya MM716 ANALOG 17R025500016
Avaya VACANT
Avaya VACANT
Avaya VACANT
147 Avaya G450 Gateway 37 16R018225652 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 15BE44400112
Avaya MB450 11IS24437146
Avaya MM716 ANALOG 17R046600207
Avaya VACANT
Avaya VACANT
Avaya VACANT
Avaya MM716 ANALOG 17R046600186
Avaya VACANT
Avaya VACANT
Avaya MM711 ANALOG 15R016000036
148 Avaya G450 Gateway 38 16R025640148 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16DT16397246
Avaya MB450 16R025442215
Avaya MM716 ANALOG 17R046600191
Avaya VACANT
Avaya VACANT
Avaya MM710B PRI 15R029300057
Avaya VACANT
Avaya VACANT
Avaya VACANT
149 Avaya G450 Gateway 39 16R047464115 Analog Voice
Gateway
Avaya PS4504
Avaya PS4504 16BE25100300
Avaya MB450 16R04743784
Avaya MM716 ANALOG 17R046600237
Avaya VACANT
Avaya VACANT
Avaya VACANT
Avaya MM710B PRI 15R029300051
Avaya VACANT
Avaya VACANT
Avaya MM710B PRI 16R023300381
579 Alpha
Technologies
0913086-001
CXPS-HX,2.5KA,2x
GJ/3P.5R.3P3W,w/AC,H
P
208Vac 3-Phase Inputs
(5-Feeds total)
>> 30x 4kW Rectifier
Module Positions
>> Distribution: 2X 4-
Position 3-pole High
Capacity Breaker Panel w/ Load LVD, Internal
Return
>> CXC HP Controller
>> 2X 50ft Temp
Sensors
010-623-20-040
Cordex HP CXRF 48-
4.0kW 208-277 VAC
Module, 4RU, Black
L0,58
7400116-001
Cordex HP CXRF 4kW
Module Blank, Black
Plastic
0250002-738
NP3716-10-001 2500A CXPS-HX
-48Vdc Power
Bay System, Parts &
Accessories
3Pole Bolt-In Breaker
Kit, 600A, CXPS-C
580 Alpha
Technologies
Model: AMPS80-3-
75,MBS
026-068-26
AMPS80 Inverter
System, scalable to
75kVA, 60kW, -48V
DC, 120/208V AC 3
phase, 9 inverter shelves, integrated Maintenance
Bypass Switch
>> 120Vac/208VAC 3-
Phase Inputs
>> Internal Maintenance
Bypass Switch
>> Hardwired
Connections
014-201-20
AIM2500 Inverter
Module 2500VA/2000W, -48VDC, 120VAC,Black
741-032-21
AMPS Blanking module
(rectifier or inverter)
495494 75KVA AMPS80
Inverter System, 581 Alpha
Technologies
0180003
PowerAgent BMS; PA
Site Controller; 6 Strings, 240 Bat Max
0180015
PowerAgent BMS, 2 V
Battery Sensor, two wire sensor (no brkt), Low
Voltage
8700144
PowerAgent BMS, Battery Monitoring
Cable Kit, 24 battery
7400220
PowerAgent BMS, 19” rack shelf, site controller mounting
5901456-001
Adaptor, 19"-23" Rack, 1RU, Steel, Zn Plated
SN: NA Poweragent
Battery
Monitoring Kit
582 Alpha
0913XXX-001
CXPS-HX,2KA,3PGJ,2-
CB,4R,3P3W,w/AC,HP
>> 208Vac 3-Phase
This is the start of the file's text. The full file is on GovTribe.