Amendment_0001.pdf
PDF 104 KB Posted
- Attached to
- Fire & Emergency Multi Service Contract Federal contract opportunity
- Solicitation number
- M0068118T0003
- Issued by
- United States Marine Corps
About this file
Amendment Questions and Answers
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M9373718SUSF001
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of the solicitation amendment is to:
1. Answ er questions concerning the solicitation.
2. Change Block 8. Offer Due Date/Local Time from 10:00AM 21 November 2017 to 10:00AM 24 November 2017.
1. CONTRACT ID CODE PAGE OF PAGES
1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 20-Nov-2017
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X M0068118T0003
X 9B. DATED (SEE ITEM 11)
07-Nov-2017
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
20-Nov-2017
CODE
REGIONAL CONTRACTING OFFICE-MCIWEST
P O BOX 555027
CAMP PENDLETON CA 92055-5027
M00681 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
M0068118T0003
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
QUESTIONS AND ANSWERS
1) Paragraph 9.10 Equipment Calibration & Testing -- What is the make, model and serial numbers for the Zoll X
Series Heart monitors?
Make: Zoll
Model: X Series
Serial Numbers: AR13H005275, AR13H005283, AR13H005421, AR13H005451, AR13H005452
2) Paragraph 9.10 Equipment Calibration & Testing. -- What is the range for the 2 torque wrenches?
Craftsman Microtork: 0 - 250 inch pounds
Proto J6177F: 0 - 250 inch Pounds
3) Paragraph 9.10 Equipment Calibration & Testing. -- Please confirm in the items: draft commander pump test trailer, Portable pump test gauges, Piot test gauges, paratech control kit WHETHER they are pressure gauges between 0 and 10,000 psi or vacuum gauges between 0 and -30 in.Hg.?
Draft Commander Trailer Model: DC1911 - 3000 / Serial # 3036-0610
Draft Commander Test Panel: 1- Vacuum Gauge: 0 - 30 in Hg, 1- Pressure Gauge 0 - 400 psi, 2- Pitot
Gauges 0 - 160 psi.
External Test Gauge Set: 1- 0 - 30 in Hg & 1 - 1- Pressure Gauge (0 – 400 psi)
Pitot Gauges (2): Qty: 1 (0 - 160 psi) & Qty: (0 - 300 psi)
HazMat Paratech Pressure Regulator: 0 - 6,000 psi
Rescue Paratech Pressure Regulator: 0 - 400 psi
Paratech Struts Pressure Regulator: 0 - 400 psi
Paratech Medium Air Bags Pressure Regulator: 0 - 30 psi
4) Paragraph 9:13 Nozzles and Appliances. NFPA requires only those attached to a hose to be hydroed and flow tested. Do you wish to have all 60 nozzles and appliances both hydroed and flowtested to cover all units which are in your inventory?
Yes, all nozzles and hose appliances flow need to be tested due to the fact that one of the spares in inventory may need to be placed on a fire apparatus at any given time.
5) Paragraph 9.16 Annual Service and Minor Repair -- Are the PPE Extractor and Dryers currently in service?
What is their model and serial number?
We currently have one extractor and one dryer in service. We have a second PPE dryer that has been delivered and will be placed into service soon.
PPE Extractor: Milnor / Model: 30022V6J / Serial # 060287470406405
Dryer: Cissell / Model: AGC65 / Serial # 6910060351
Dryer: Ready Rack / Model: PPEHD / Serial # 93804M001012
M0068118T0003
6) Paragraph 9.16 Annual Service and Minor Repair -- What is the model number for the paratech struts and extensions?
Paratech Gold Struts:
Model: 235L / Part #22-796342 Qty. 3
Model: 304 Part #22-796720 Qty. 2
Model: 435L Part # 22-796356 Qty.3
Model: 406 Part #22-769730 Qty. 2
Model: 610L Part #22-796360 Qty. 2
Paratech Grey Struts:
22-796200 Qty. 4
22-796012 Qty.1
22-796024 Qty. 4
22-796202 Qty. 8
22-796154 Qty. 1
7) Paragraph 9.17 Turnout Inspection and Testing -- Do you wish to have advanced cleaning and advanced inspections performed onsite using your extractors and dryers? Would you like to have minor repairs included in the quoted price?
Advanced cleaning should be done offsite as we cannot currently control the PPE waste water. The advanced inspection can take place onsite but it does not need to be.
No, any repairs will be performed as over and above work (See Paragraph 7)
8) Paragraph 9.18 Live Fire Trainer -- What is the make, model and serial number of the fire trainer?
Make: Kirila Fire Training
Model: KFP-AR-001
Serial # 5L3EY3436FL000612
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 21-Nov-2017 10:00 AM to 24-Nov-2017 10:00 AM.
(End of Summary of Changes)