LT0742 2021 PASCAL Brochure.pdf
PDF 12 MB Posted
- Attached to
- 6540--Pascal Synthesis (577) Photocogulator System Federal contract opportunity
- Solicitation number
- 36C25621Q1169
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| S02 36C25621Q1169- PASCAL SYNTHESIS 577 LASER - 06-17-21.pdf | ||
| 36C25621Q1169_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PASCAL® Synthesis™
Photocoagulator pascalvision.com | 888.850.1223 | pascalservice@iridex.com
Industry Leading PAttern SCAnning Laser Technology PASCAL® Synthesis™
PASCAL® represents a quantum leap in ophthalmic treatment technology and is committed to helping you deliver effective results for your patients. Demanding ophthalmologists choose PASCAL® because of its speed and ease of use.
Developed in partnership with Stanford University, the PASCAL® method of photocoagulation treats retinal conditions using a single spot or a user-selected pattern array. Most importantly, it was designed to provide control and flexibility in the treatment of eye conditions.
Pattern scanning method is the preferred way and I believe it’s standard of care.
Mark S. Blumenkranz, MD HJ Smead Professor and Chair Director of the Byers Eye Institute at Stanford University
Experience the PASCAL® Advantage The collaboration between researchers and clinical experts resulted in a laser system recognized and used by physicians worldwide.
Overview of PASCAL Synthesis
1. Optional
2. Mauricio Turati, Felix Gil-Carrasco, Adolfo Morales, Hugo Quiroz-Mercado, Dan Anderson, George Marcellino, Georg Schuele, DanielPalanker. “Patterned
Laser Trabeculoplasty.” Ophthalmic Surg Lasers Imaging 2010;41: 538-545.
The PASCAL technology was developed in partnership with Stanford University
Exclusive Precision Spots with Multi-Fiber Beam Technology
Reduced power and short pulses produce less discomfort during treatment
Rapid pattern scanning laser delivery
Precise alignment and continuous laser pulse directed by high speed galvanometers
Enhanced laser delivery slit lamp
Endpoint Management for sub-threshold treatment1
Pattern Scanning Laser Trabeculoplasty (PSLT)1 for IOP reduction2
PASCAL Conventional Laser
Courtesy: Dr. Daniel Palanker Associate Professor Department of Ophthalmology, School of Medicine, and Hansen
Experimental Physics Laboratory Stanford University.
Unlike conventional laser burns, PASCAL’s shorter pulse duration (10ms) results in faster procedures with less pain, collateral damage and scarring for your patients.3
3. Manish Nagpal et. al., “Comparison of laser photocoagulation for diabetic retinopathy using 532-nm standard laser versus multispot pattern scan laser. “ RETINA 30:452-458,2010
Now Featuring A New Laser Delivery Slit Lamp
SL-PA04
Ergonomic Design and Improved Optical Design Improved coaxiality between the slit illumination and the aiming beam provides better visibility of the peripheral retina.
Comfortable Observation with our NEW Binocular System The CB-8 binocular system with 8-degree angle provides clear vision. The smooth movement of the PD adjustment makes it easier to find a comfortable PD range. New magnification configuration improves visibility of the treatment area. The 5x, 8x, 13x, 20x and 32x magnification grouping allows for a wider view of the treatment area.
Power Adjustment Knob Quick and precise adjustment of the laser treatment power.
LED Illumination Sharp and homogeneous LED illumination for comfortable viewing
Gooseneck Fixation Target Easy to adjust the fixation target.
Micro-manipulator Allows precise alignment of aiming beam and treatment delivery.
Endpoint Management™ Sub-threshold Treatment for Retinal Disorders Endpoint Management (EpM)* is a pattern sub-threshold retinal laser therapy that uses a unique algorithm to control laser power and pulse duration, optimizing the therapeutic effect of the laser at sub-visible levels.
Endpoint Management is Mathematically Precise
The Arrhenius Integral coupled with extensive data on retinal laser-tissue interactions defines the algorithms for Endpoint Management. By use of this formula, heat induced changes in the retina are controlled as Endpoint Management simultaneously modulates the laser power and duration, providing linear control over a non-linear process.
Landmark™ Patterns
The Landmark feature is a useful tool for tracking the sub-visible areas which have been treated, assisting with the treatment process and taking the guesswork out of successive treatments.
Easy Operation
The yellow dots displayed on the user interface treatment pattern display indicate the laser spots that will be delivered using the energy level set by Endpoint Management. While Endpoint Management is active, the red dots indicate the laser spots that will be delivered at the titration energy level ("100% level") and will provide the "Landmark" reference points outlining the treated area.
TIME
THRESHOLDS
HEMORRHAGE
BARELY VISIBLE
NON-VISIBLE
FA
OCT
NON-THERAPEUTIC
ENDPOINT
MANAGEMENT
ALGORITHMS
P O
W E
R
EpM ON / Landmark OFF
EpM OFF EpM ON / Landmark ON
40 %
*EpM is optional software
EpM OFF EpM ON / Landmark OFF
EpM ON / Landmark ON
Endpoint Management™
Clinical Case
Diabetic Macular Edema
Diabetic Retinopathy
Dr. Daniel Lavinsky | Porto Alegre, Rio Grande do Sul, Brazil
64 years old with Type 2 DM for over 20 years. Severe nonproliferative diabetic retinopathy with macular edema OU. Patient submitted to one intravitreal injecton of Ranibizumab.
She had a panic attack during the procedure and refused additional injections.
Physician:
Patient:
Pre-EpM VA 20/60
Pre-EpM VA 20/60
1 year and 9 months Post-EpM VA 20/20
1 year Post-EpM VA 20/20
Physician:
Patient:
Dr. Daniel Lavinsky | Porto Alegre, Rio Grande do Sul, Brazil
46 years old, male with decreased visual acuity since childhood due to nystagmus.
Patient refused use of steroids or other medications.
* Courtesy: Lavinsky D, Palanker D. Non Damaging photothermal therapy for the retina: initial clinical experience with chronic central serous retinopathy.Retina. 2015;35(2):213-22.
IOP reduction of >-30% was maintained through 18months
By Miho Nozaki, MD, PHD, and Kaweh Mansouri, MD, MPH/Nov/Dec 2015 Insert to Glaucoma Today
0d 1W 1M 2M 3M 4M 5M 6M 8M 9M 10M 12M 16M 18M
PSLT PG O�
IO
P m m
H g
Follow-up Period
IOP After PSLT
*1 PSLT is optional software
*2 Mauricio Turati, Felix Gil-Carrasco, Adolfo Morales, Hugo Quiroz-Mercado, Dan Anderson, George Marcellino, Georg Schuele, Daniel Palanker.
“Patterned Laser Trabeculoplasty.” Ophthalmic Surg Lasers Imaging 2010;41: 538-545.
PSLT™ (Pattern Scanning Laser Trabeculoplasty) treatment for IOP Reduction
Pattern Scanning Laser Trabeculoplasty (PSLT)*1 is a tissue-sparing laser treatment for reducing intraocular pressure in open angle glaucoma. PSLT provides a rapid, precise, and minimally traumatic computer-guided treatment that applies a sequence of patterns onto the trabecular meshwork.*2
Clear Advantages of PSLT
• Computer guided treatment
• Sub-visible procedure
• Clinical studies show an IOP reduction of 24% in 6 months
• Ability to retreat if necessary
Ease of Operation
PSLT provides a computer guided placement of the treatment patterns ensuring full coverage of the trabecular meshwork and eliminating the chance of overlap.
RPE
ILM
RPE
ILM
PASCAL's® Versatility Maximizes Your Workflow
More Patterns. More Treatment Options.
PASCAL offers a vast selection of patterns. The extensive pattern palette provides many variations to suit nearly every clinical need.
Uninterrupted Aiming Beam
Bright and clear continuous aiming beam can help the operator to precisely aim at the target position.
Multi-Fiber Beam Delivery System
PASCAL Synthesis multi-fiber beam delivery provides one dedicated fiber optic for each spot size.
This increases depth of field compared to zoom optic laser systems.
Multi-Fiber Beam Delivery Zoom optic laser systems
Wide depth of focus
Narrow depth of focus
Profile image of beam delivery:
PASCAL has uniform energy distribution
Profile image of beam delivery:
Other lasers have "hot spots" in the beam profile
Family of Premier Retina Lasers:
Sophisticated Technology, Elegantly Designed In order to help you and your patients, we never stop improving. When you understand the science behind our advancements, you’ll understand why PASCAL is really a synthesis of innovations, all working together to further the field of ophthalmology.
PASCAL® Synthesis
• Available in 577 and 532 nm wavelengths (yellow/green)
• Integrates seamlessly with Topcon SL-PA04,
• SL-D7, Haag-Streit™, BM900 and BQ900
PASCAL® TwinStar
• Includes both 577 nm + 638 nm wavelengths (yellow+red) in a single system
• Integrates seamlessly with Topcon SL-PA04 slit lamp
PASCAL® LIO*
(Laser Indirect Ophthalmoscope)
• Allows physicians to offer laser photocoagulation treatments to patients unable to sit at a slit lamp
• Small and lightweight headset battery offers up to 2 hours of use without recharging
* Optional accessory to Synthesis, not available with TwinStar
Topcon SL-PA04 G4 and Y4
Topcon SL-D7 G7 and Y7
Topcon SL-PA04 (TwinStar)
PASCAL® LIO
Case Images
Proliferative Diabetic Retinopathy Retinal Hole
Post laser photocoagulation Post laser photocoagulation
( 2 months )
Result is greater patient comfort with decreased pain. Much safer, much more effective.
Pravin U. Dugel, MD Retinal Consultants of Arizona
L E A R N M O R E pascalvision.com
*Courtesy: Hiroyuki Nomoto, MD, Nomoto Eye Clinic
IMPORTANT In order to obtain the best results with this instrument, please be sure to review all user instructions prior to operation. Not available for sale in all countries. Please check with your local distributor for availability in your country.
Synthesis (Y7 / G7 / Y4 / G4) Synthesis TwinStar
Laser
Patterns
Power
Power Control
Treatment
Aim Beam
Aim Beam Power
Delivered Spot Size
User Interface
Slit Lamp Compatibility
Laser Console Dimensions
Input Power Requirement
Cooling
*1 : 577nm is for Single, Pattern scan, PSLT and Endpoint Management. 638nm is only for single spot.
*2: Triple arc is only for Angle treatment by PSLT *3: EpM is optional software *4: Optional accessory *5: Pulse Durations 5ms is only for Triple arc
577nm , 638nm*1Available in 577nm or 532nm Optically
Pumped Semiconductor (OPSL)
577nm: 50, 100, 200, 400μm
638nm: 60, 200μm
50, 100, 200, 400μm
Single Spot, Array, Triple Arc*2, Triple Ring, Arc, Line, Circle, Enhanced Octants (EpM*3), Wedge, Hexagon
0 - 2000mW 577nm: 0 - 2000mW
638nm: 0 - 600mW
3-D Controller*4 and Touch Screen User Interface
Pulse Durations 5 to 1000ms*5
635nm diode 670nm diode
Adjustable to < 1mW
3D Controller*4 and Touch Screen Control Panel Display (26.5 cm; 10.4 in)
Haag-Streit BM900 and BQ900,Topcon SL-PA04 and SL-D7 Topcon SL-PA04 Height: 23 cm (9 in)
Length: 31 cm (12 in)
Width: 38 cm (15 in)
Weight: 15 kg (35 lbs)
100 - 240 VAC; 50/60Hz 200VA
TEC / Air Cooled
Specifications pascalvision.com | 888.850.1223 | pascalservice@iridex.com Contact PASCAL® Service today to learn more.
LT0742.A 04.2021
File details come from the government source that posted it. Updated .