KAN RHIB Engine Salient Characteristics.docx

DOCX document 37 KB Posted

Attached to
USNS KANAWHA RHIB Engine Federal contract opportunity
Solicitation number
N3220521Q2556
Issued by
Department of the Navy Military Sealift Command

View the file

Other files for this federal contract opportunity

Other files attached to USNS KANAWHA RHIB Engine, newest first.
File Type Posted
Amend4 N3220521Q2556 Combined Synopsis Solicitation.pdf PDF
Amend3 21Q2556 Combined SS.pdf PDF
Amend2 N3220521Q2556 CSS.pdf PDF
N3220521Q2556 CSS Amend1.pdf PDF
N3220521Q2556 COmbined Synopsis Solicitation.pdf PDF
SSJ Urgent KAN RHIB Engine_redacted.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USNS KANAWHA

T-AO 196

Material Order

Rescue Boat Engine Salient Characteristics

1.0 Technical Data

Air inlet pressure/ inlet manifold temperature

Supply voltage
5 V
Connector
4 pin
Pressure measurement range
50–400 kPa (0.5-4.0 bar)
Temperature measurement range
-40 °C to +130 °C (-40 °F to +262 °F)
Type
Linear/NTC
Max. tightening torque
20 Nm (14.8 lbf.ft.)

Camshaft

Supply voltage
5 V
Connector
3 pin
Type
Hall effect sensor
Max. tightening torque
8 ± 0.5 Nm (5.9 ± 0.37 lbf.ft.)

Coolant temperature

Voltage
3.3 V
Connector
2 pin
Temperature measurement range
-40 °C to +125 °C (-40 °F to +257 °F)
Type
NTC
Max. tightening torque
22 Nm (16.2 lbf.ft.)

Fuel temperature

Voltage
3.3 V
Connector
2 pin
Temperature measurement range
-40 °C to +125 °C (-40 °F to +257 °F)
Type
NTC
Max. tightening torque
22 Nm (16.2 lbf.ft.)

Flywheel (crankshaft)

Connector
2 pin
Type
Inductive sensor

Oil level / oil temperature

Supply voltage
12 V
Connector
3 pin
Max. tightening torque
8.4 Nm (6.2 lbf.ft.)

Oil pressure

Supply voltage
5 V
Connector
3 pin
Pressure measurement range
0–700 kPa (0-7 bar) (0–101.5 kPa)
Type
Linear

Rail pressure

Supply voltage
5 V
Connector
3 pin
Pressure measurement range
0–200 MPa (0-2000 bar) (0–29008 PSI)
Type
Linear
Max. tightening torque
20 ± 2 Nm (14.8 ± 1.48 lbf.ft.)

Water in fuel

Supply voltage
12 V
Connector
2 pin
Contact type
Closes when water is detected

Alternator

Voltage
14 V
Capacity
150 A

Starter motor

Voltage
12 V
Capacity
2.2 kW

Fuses

Protects
EECU, EVC system
Type
Circuit breaker
Ampere
20 A
Protects
Trim pump
Type
Circuit breaker
Ampere
50 A
Protects
Fuel pump
Type
Blade fuse
Ampere
15 A

Electric fuel pump

Voltage, U
Pressure
Current, I
Flow rate
8.0 ± 0.1 V
50 + 10 kPa

(7.3 + 1.5 psi)

< 2.8 A
> 130 l/h

(28.6 US gals/h)

13.0 ± 0.1 V
50 + 10 kPa

(7.3 + 1.5 psi)

< 5.2 A
> 235 l/h

(51.7 US gals/h)

8.0 ± 0.1 V
450 + 10 kPa

(65.2 + 1.5 psi)

< 7.5 A
> 40 l/h

(8.8 US gals/h)

13.0 ± 0.1 V
450 + 10 kPa

(65.2 + 1.5 psi)

< 8.0 A
> 165 l/h

(36.3 US gals/h)

Engine Protection Map

Sensors
Alarm switch
Alarm level

(orange lamp) Derating level (red lamp)

Condition/delay
Derate

Air inlet pressure offset high offset low

30 kPa (4.35 PSI) > map value

30 kPa (4.35 PSI) < map value

30 kPa (4.35 PSI) > map value

Only above 2000 rpm.

10 seconds delay

Yes

No

Coolant Level
when closed
low level
-
-
No
Coolant Temperature
-
98 °C (208.4 °F)
101 °C (213.8 °F)
2 seconds delay
Yes
Fuel Temperature
-
70 °C (158 °F)
70 °C (158 °F)
12 seconds after start

2 seconds after delay Yes

Intake manifold temperature
-
80 °C (176 °F)
90 °C (194 °F)
2 seconds after delay
Yes
Oil temperature
-
-
135 °C (275 °F)
-
Yes
Oil Pressure
-
oil pressure map
oil pressure map
1 seconds delay
Yes
Rail pressure offset
-
rail pressure map ± 200 bar (2900 PSI)
rail pressure map

± 200 bar

(2900 PSI)

Above 740 rpm.

1 seconds delay Yes

Water in Fuel
when closed
water in fuel
-
30 sec
No

[Type here]

File details come from the government source that posted it. Updated .