J-11 Dry Dock Eval Form.docx
DOCX document 39 KB Posted
- Attached to
- USNS RICHARD E. BYRD FY24 MTA Federal contract opportunity
- Solicitation number
- N3220523R4081
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N3220523R4081-0002.pdf | ||
| J-2-Cat-A rev.xlsx | XLSX spreadsheet | |
| J-8 RFC.doc | DOC document | |
| N3220523R4081.pdf | ||
| J-14 Technical Data Non-Disclosure.docx | DOCX document | |
| J-13- Past Perf Questionaire.docx | DOCX document | |
| J-7 MSC Ship Repair Facility Survey.doc | DOC document | |
| J4 REPORT ICO USNS RICHARD BYRD JAN 2024 MTA.xlsx | XLSX spreadsheet | |
| J-12 Past Perf Data.docx | DOCX document | |
| J-9 Disclsr Lobbying Activities.doc | DOC document | |
| J-5 Subcontracting Plan Assessment Checklist.docx | DOCX document | |
| J-3-Cat-B.xlsx | XLSX spreadsheet | |
| J-2-Cat-A.xlsx | XLSX spreadsheet |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N3220520R6501 N3220523R4081
MSC DRYDOCK EVALUATION FORM
| Ship name: |
| USNS RICHARD E. BYRD |
| Hull No: |
| T-AKE 4 |
PART A (to be completed by MSC)
PART B (to be completed by ALL shipyards)
Drydock Certification / Classification Info
Shipyard name
Drydock No.
Drydock Type Graving |_| Floating |_| Marine Railway |_|
Certified? Yes |_| No |_|
Certifying / Classifying Agency
Certificate No.
Date of expiration
| Ship Characteristics |
| English measure |
| Metric measure |
Provide date in English and Metric Units:
| Length, overall |
| 643 |
| ft - |
| 8 |
| In |
| 0.0 m |
Drydock Characteristics
| Breadth, molded |
| 85 |
| ft - |
| 0 |
| In |
| 0.0 m |
Length, overall ft-in m
| Draft, light load line |
| N/A |
| ft - |
| 0 |
| In |
| 0.0 m |
Breadth ft-in m
| Gross Tonnage (U. S.) |
| N/A |
| Tons |
MT
| Displacement, Full Load |
| 20,868 |
| LT |
MT
Maximum drydock lift capability
LT
MT
Minimum Displacement/Draft
| Displacement |
| 20,868 |
| LT |
MT
| Draft – forward |
| 21 |
| ft - |
| 0 |
| In |
| m |
Maximum entry draft rating:
LT
MT
| Draft – aft |
| 25 |
| ft - |
| 0 |
| In |
| m |
| Max stern trim for graving dock |
| 4 |
| ft - |
| 0 |
| In |
| m |
Water depths around dock ft-in m area and approaches, tidal conditions, Anticipated Arrival Draft and any unusual conditions for entering/
| Draft - forward |
| 24 |
| ft - |
| 0 |
| In |
| m |
leaving the drydock.
| Draft - aft |
| 24 |
| ft - |
| 0 |
| In |
| m |
Depth Over Floor ft-in m
Positioning Clearances
Depth Over Blocks ft-in m
| Bottom: keel to drydock floor |
| 5 |
| ft - |
| 0 |
| In |
| m |
Depth Over Sill ft-in m
| Side: hull to drydock wall |
| 5 |
| ft - |
| 0 |
| In |
| m |
Depth Over KEEL ft-in m
Loading Pressures
| Max block loading |
| 20 |
| Tons Per square ft. |
| per sq mtr |
Note: All blocks to be positioned under longitudinal strength members and transverse bulkheads.
MSC DRYDOCK EVALUATION FORM (cont’d)
PART A (to be completed by MSC)
PART B (to be completed by ALL shipyards)
Max Block Loading Capability
Blocking Requirements
Block Capability
LT/ft2
LT/m2
| Construction |
| Hard Wood |
Keel & Side Block Information
| Cap material |
| Soft Wood |
Construction
| Cap thickness (min) |
| 2 |
Cap Material
| Side blocks (e.g., shaped, wedged, etc.) |
| Shaped |
Cap Thickness in cm
Block Age
Hardwood: White Oak, California Laurel, Oregon Myrtle, Iron bark, Height ft-in m
Blue Gum, American Rock Elm or Preserved Red Oak.
Width ft-in m
Softwood: Douglas Fir, Tamarack, Long Leaf Pine or Hemlock
Length ft-in m
Minimum Required Services
Minimum Available Services
Electrical power
Electrical power
| AC volts | |
| 450 | |
| VAC |
AC volts
| number of phases | |
| 3 |
number of phases
VAC
| amperage (total) | |
| 4000 | |
| Amps |
amperage (total)
| frequency | |
| 60 | |
| Hz |
frequency amps
| number of lines | |
| 10 |
number of lines
Hz
Ground connections
Ground connections
| number | |
| 2 |
number
| cable size, each | |
| 500,000 | |
| cir mils |
cable size, each cir mils
Sewage connections
Sewage connections
| number | |
| 1 |
number
| pipe size | |
| 4 | |
| inch ips |
pipe size
| capacity | |
| 60,000 | |
| gals per day | |
| 227,124.7 liters per day |
capacity inch ips cm gal/day ltr/day
Fire Main
Fire Main
| number of connections | |
| 2 |
number of connections
| connection size | |
| 2 1/2 | |
| inch ips |
connection size
| pressure | |
| 125 | |
| Psig | |
| 8.8 | kg per sq cm |
pressure inch ips cm
| capacity | |
| 1,000 | |
| gals per min | |
| 3,785.41 liters per min |
capacity psig kg/m2 gpm ltr/min
Aux Seawater
Aux Seawater
| pressure | |
| 135 | |
| Psig | |
| 9.5 | kg per sq cm |
pressure
| capacity | |
| 3000 | |
| gals per min | |
| 11,356.24 liters per min |
capacity psig kg/m2 gpm ltr/min
Fresh Water
Fresh Water
| pressure | |
| 60 | |
| Psig | |
| 4.2 | kg per sq cm |
pressure
| capacity | |
| 100 | |
| gals per min | |
| 378 | liters per min |
capacity psig kg/m2 gpm ltr/min
MSC DRYDOCK EVALUATION FORM (cont’d)
Compressed Air
Compressed Air
| pressure | |
| 125 | |
| Psig | |
| 8.8 | kg per sq cm |
pressure
| capacity | |
| 750 | |
| cu ft per min | |
| 21,237.64 liters per min |
capacity psig kg/m2 cfm ltr/min
Shore Steam
Shore Steam
| pressure | |
| 145 | |
| psig | |
| 10.19 kg per sq cm |
pressure
| capacity | |
| 6,000 | |
| lbs per hour | |
| 2,722 kg per hour |
capacity psig kg/m2 lb/hr kg/hr
| High Pressure Water Wash pressure | |
| 3,000 | |
| psig | |
| 274.20 | kg per sq cm |
High Pressure Water Wash pressure psig kg per sq cm
Safety Response Plans Required
Safety Response Plans Available (circle correct answer)
| Firefighting | |
| Yes | X |
| No | |_| |
Firefighting
| Flooding (accidental) | |
| Yes | X |
| No | |_| |
| Flooding (accidental) |
| Yes |
| No |
| Earthquake | |
| Yes | |X| |
| No |
| Earthquake |
| Yes |
| No |
| Typhoon | |
| Yes | |X| |
| No |
| Typhoon |
| Yes |
| No |
PART C (to be completed by Shipyard if drydock is not certified by IACS or under MIL STD 1625C)
Dockmaster info
Contractor name
Dockmaster name
Certifying Agency
Certificate No.
Years experience
Drydock Insurance Info
| Is Drydock insured? | |
| Yes |_| | No |_| |
Insurer
Policy No.
Amount Insured
Date of expiration
Attachment J – 11