This document provides an item description for four 400Hz power/frequency converters required by the Department of the Air Force under solicitation number FA812523Q0003. The item description specifies that the converters must be 180kVA, trailer mounted units capable of converting conventional electrical power to 400Hz aircraft power. Each unit must have a dual AC output supplying 90kVA on each of two legs running in parallel. The output and input plugs and cables are defined. The units must be certified for indoor/outdoor use and include an integrated display console with diagnostics. Delivery is required to Tinker Air Force Base with startup service included.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA812523Q00030002 SF 30.pdf | ||
| Solicitation - FA812523Q0003.pdf | ||
| Solicitation Amendment - FA812523Q00030001.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS AIR FORCE SUSTAINMENT CENTER (AFMC)
TINKER AIR FORCE BASE OKLAHOMA
Item Description A23‐008 KC46 Frequency Converters
Four (4) 400Hz Power/Frequency Converters with the following specifications:
• 180kVA, trailer mounted 400Hz power converter
• Be able to convert any conventional electrical power to 400Hz aircraft power
• Output Power o 180kVA o Output shall be Duel AC output power o two (2) legs, each supplying 90KVA
• The output plugs shall be AERO Plug 400 Hz AC 2/0 GPU connector Plug, 6‐
Pole Female, SKU 2014856
• Both output legs shall be ran in parallel to each other o Each cable for the two (2) outputs shall be 60ft long
• The two (2) output legs shall be the same length
• Input Power o 480V, 250 AMP o Plug shall be a 480V, 400amp Appleton plug PN AP40134G o The cable for the input power shall be 100ft long
• Trailer mounted, towable with at least 18‐inch Hazard Area Clearance
• Indoor/outdoor all weather use (hangar/ramp)
• Certified to UL 1012
• Advanced integrated display console containing event log/diagnostics
• Emergency power “OFF” switch
• Input and output cable racks on the trailer
• startup service the units once delivered
• Turn key
• Deliver to Tinker AFB fully assembled
File details come from the government source that posted it. Updated .