Item Description for B-52 Jacking Extensions.pdf
PDF 285 KB Posted
- Attached to
- B-52 Jacking Extensions Federal contract opportunity
- Solicitation number
- FA812524Q0023
About this file
This document provides details for a federal contract solicitation for B-52 jacking extensions. The solicitation number is FA812524Q0023 and is being issued by the Department of the Air Force Materiel Command Air Force Sustainment Center. Interested contractors must have an active 2345 on file through the JCP Portal in order to receive technical drawings and specifications for providing B-52 jacking extensions. The solicitation and associated attachments contain additional requirements for the product. No further information is provided on response dates, pricing terms, or other contract details.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation - FA812524Q0023.pdf | ||
| Updated B-52 Jacking Extensions SOW.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS AIR FORCE SUSTAINMENT CENTER (AFMC)
TINKER AIR FORCE BASE OKLAHOMA
MEMORANDUM FOR RECORD
SUBJECT: Item Description, A24-011 B-52 Jacking Extensions
1. 76 AMXG is requesting the utilization of funds for the purchase of B-52 Jacking Extensions.
The B-52 Jacking Extensions allows PDM to implement a more comprehensive jacking configuration with the 30-ton jack and 60-ton jack, this will allocate additional space for concurrent maintenance.
2. The requested descriptions/specifications are outlined below.
Fabricate two (2) B-52 Bomb Bay Jack Fittings X202316178-10 and two (2) B-52 Bomb Bay Jack Fittings X202316178-30. Non-destructive Inspect (NDI) all welds for cracks and provide inspection report. These units will be use as prototypes to provide functionality and fitment checks prior to fabrication of remaining production units.
Contractor must also proof load one (1) B-52 Bomb Bay Jack Fittings X202316178-10 and one (1) B-52 Bomb Bay Jack Fittings X202316178-30 with a compressive axial proof load of 6500 lbs. thru the 1.0-inch openings in Find No. 10 and 11. Inspect assemblies after proof load for structural damage and NDI welds for cracks/failures.
Inspection report is required to detail condition after proof load.
Once the prototypes have been tested and approved, fabricate ten (10) B-52 Bomb Bay
Jack Fittings X202316178-10 and ten (10) B-52 Bomb Bay Jack Fittings X202316178-
30. Non-destructive Inspect (NDI) all welds for cracks and provide inspection report.
File details come from the government source that posted it. Updated .