1 HVAC Trainer to be purchased. Mini split‐type air conditioner hands on trainer to include an indoor unit (evaporator) mounted remotely from the outdoor unit (condenser). The trainer shall come packaged on a mobile carrier on a mechanical steel base and frame. The frame shall be finished to prevent corrosion. Provide two locking and two non‐locking caster. The indoor unit shall be enclosed in an environmental chamber consisting of clear polycarbonate and steel frame. The environmental chamber shall have an associated heater and thermocouple control for manipulating the environmental conditions of the evaporator. The students will be required to evacuate, charge and troubleshoot the system and shall come with high and low pressure gauges and programmable fault capability. The cooling capacity shall be between 9,000 and 12,000 BTU/H.