Text version

USCGC KENNEBEC (WLIC-802) LODGING FY2016

USCGC KENNEBEC (WLIC 802)

160 FOOT INLAND CONSTRUCTION TENDER

SPECIFICATION FOR LODGING DURING DRYDOCK REPAIRS

FY2016

Developed By: Raymond L. Murray

(29 AUG 2016)

TABLE OF CONTENTS

3Revisions Record

4Lodging, Provide

Revisions RecordThis page is used to record specification revisions, which may have occurred subsequent to a Revision 0 (Rev-0) package. Information listed is intended to provide contractors and field unit personnel a means to ensure all the current specification revision pages are present when reviewing or utilizing this specification package.

DATE
REV#
WORK ITEM#
CHANGES MADE
29 Aug 2016
1
3.1
Changed radius of lodging facility from within 20 miles of Detyens shipyard to a radius of at least 10 miles away but not more than 20 miles away from Detyens shipyard, 1670 Drydock Ave #236, North Charleston, SC 294052114.

NOTE : All work item and paragraph numbers listed above for a given revision correspond to same numbers in the previous revision. This revised specification is self-contained with all of the above listed changes incorporated.

86353_1111_SOW_FLT

Lodging, Provide

1. SCOPE

1.1 Intent. This work item describes the requirements for the Contractor to provide temporary lodging for 15 Coast Guard personnel.

1.2 Government-furnished property.

None.

2. APPLICABLE DOCUMENTS

Coast Guard Drawings None.

Coast Guard Publications None.

Other References AAA/CAA -http://www.aaanewsroom.net/Main.asp?CategoryID=9&SubCategoryID=22& Hotel and Motel Fire Safety Act of 1990 (PL101-391) FORBES (formerly MOBIL) Travel Guide - http://www.forbestravelguide.com/

3. REQUIREMENTS

3.1 Lodging requirements. The Contractor shall provide quality temporary lodging for 15 Coast Guard personnel.The lodging facility shall be at least 10 miles and no more than 20 miles of Detyens Shipyard Incorporated, 1670 Drydock Ave # 236, North Charleston, SC 294052114.

3.1.1 Occupancy particulars. Provide 06 double occupancy and 03 single occupancy rooms for Coast Guard personnel.

3.1.2 Commencement and completion. Ensure that lodging shall commence 20 SEPT 2016 and terminate 08 NOV 2016.

3.2 Regulations and standards. The Contractor shall ensure that all lodging facilities provided shall meet the following minimum standards:

· Meet the Hotel and Motel Fire Safety Act of 1990 (PL101-391) and be listed on the Hotel-Motel Master List (see 4.1 (Hotel and Motel Fire Safety Act of 1990 (PL101-391).

· Lodging Facility shall be at least 10 miles and no more than 20 miles of Detyens Shipyard Incorporated, 1670 Drydock Ave # 236, North Charleston, SC 294052114.

· Facility shall meet at a minimum the requirements of either three stars for a Mobil Travel Guide rating, three diamonds for an American Automotive Association (AAA) rating or Cranley Rating Level six (6).

· Full indoor laundry facility on premises with 24/7 guest access.

· Full access and use of a workout facility or fitness center in designated exercise room w/ dedicated equipment specialized for the use of working out (e.g. treadmill, rowing machine, elliptical machine, weight machine, free weights etc.). Facility shall be either on the lodging facility premises or within walking distance (not to normally exceed ½ mile or 5 minute commute via vehicle).

· Access to internet in all rooms.

· Include daily cleaning, change of linen, and replenishment of toiletries.

· Iron and Ironing Board in every room

· Full Bath

· Each room shall be equipped for extended stay and include at a minimum a refrigerator, stove-top w/oven, kitchen sink, cooking utensils and eating utensils.

· Berthing facility room entrances shall be accessible only by internal hallway(s). The berthing facilities internal hallway(s) shall have locked exterior doors, accessible by key-holding facility guests only. Internal hallway(s) shall be accessible by the berthing facility’s lobby. The berthing facilities lobby shall be manned by a front desk attendant 24 hours a day and 7 days a week.

3.3 Parking. The Contractor shall ensure that the lodging facility must have parking available for a minimum of 3 vehicles during the entire duration of the stay.

4. NOTES

4.1 Hotel and Motel Fire Safety Act of 1990 (PL101-391). Information on the Safety Act and the Master Hotel list can be found at http://www.usfa.fema.gov/applications/hotel/.

4.2 Rating criteria. Rating criteria can be found at the following websites:

· AAA/CAA - http://www.aaanewsroom.net/Main.asp?CategoryID=9&SubCategoryID=22& Select “Diamond Ratings.”

· FORBES (formerly MOBIL) Travel Guide - http://www.forbestravelguide.com/

5
(Rev-1)