This document outlines specifications for work to be accomplished on the YRBM 32 naval vessel. The specifications cover a range of repair, replacement, inspection, and cleaning work items throughout the vessel, including replacing deteriorated steel decking; inspecting and testing systems like the telephone, firemain, and potable water systems; removing and replacing an aqueous potassium carbonate fire extinguishing system; inspecting and testing the accommodation ladder; resealing windows; and conducting a deep clean of all interior spaces. The related federal contract opportunity is a pre-solicitation notice for contract N32253-24-R-0002 regarding work on YRBM32 under the Department of the Navy Naval Sea Systems Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| YRBM 32 Questions and Answers.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE NAVY
HRMC (NMD)
YRBM 32 (YRBM 13204)
SPECIFICATIONS FOR WORK TO BE ACCOMPLISHED
SPECIFICATION NUMBER: HRMC-008-24
INCLUDES ALL CHANGES THROUGH 10/6/2023
INDEX
SHIP: YRBM 32 (YRBM 13204) HRMC-008-24
ITEMS THAT ARE STRUCK OUT IN THIS INDEX DO NOT APPLY TO THIS CONTRACT.
CATEGORY I. FY-24 STANDARD ITEMS APPLICABLE TO THIS JOB ORDER WITHOUT FURTHER REFERENCE.
ITEM_NO. TITLE CHANGE DATE CHANGE
009-01 General Criteria; accomplish 09/27/2022 Original
009-02 Environmental Compliance Report for Material Usage; accomplish 09/27/2022 Original
009-03 Toxic and Hazardous Substance; control 09/27/2022 Original
009-04 Quality Management System; provide 09/27/2022 Original
009-05 Temporary Access; accomplish 09/27/2022 Original
009-06 Maintaining Protection and Cleanliness from Non-Radioactive Operations;
accomplish
09/27/2022 Original
009-07 Confined Space Entry, and Certification; accomplish 09/27/2022 Original
009-08 Shipboard Fire Protection and Fire Prevention; accomplish 02/28/2023 CH-1
009-10 Asbestos-Containing Material (ACM); control 09/27/2022 Original
009-18 Mine Warfare Ships Magnetic Material; control 09/29/2022 Original
009-19 Provisioning Technical Documentation (PTD); provide 09/27/2022 Original
009-20 Government Property; control 09/27/2022 Original
009-21 Logistics and Technical Data; provide 09/27/2022 Original
009-23 Interference; remove and install 09/29/2022 Original
009-24 Authorization, Control, Isolation, Blanking, Tagging, and Cleanliness; accomplish 09/27/2022 Original
009-34 Fire Protection of Unmanned Vessel at Contractor Facility; accomplish 09/27/2022 Original
009-39 Technical Manual Contract Requirement (TMCR) for a New Technical Manual for
Commercial Equipment/Component; accomplish
09/27/2022 Original
009-40 Contractor Crane, Multi-Purpose Machine and Material Handling Equipment at a
Naval Facility; provide
09/27/2022 Original
009-60 Schedule and Associated Reports for CNO Availabilities; provide and manage 09/30/2022 Original
009-61 Shipboard Use of Fluorocarbons; control 09/27/2022 Original
009-67 Integrated Total Ship Testing; manage 09/27/2022 Original
009-69 Heavy Weather/Mooring Plan; provide 09/27/2022 Original
009-70 Confined Space Entry, Certification, Fire Protection, Fire Prevention and
Housekeeping for Unmanned Vessels; accomplish
09/27/2022 Original
009-72 Physical Security at a Private Contractor Facility; accomplish 09/30/2022 Original
009-73 Shipboard Electrical/Electronic Cable Procedure; inspect, test, install, remove, and repair
09/30/2022 Original
009-74 Occupational, Safety and Health Plan; accomplish 09/30/2022 Original
009-80 Ship Facilities; maintain 09/27/2022 Original
009-81 Compartment Closeout; accomplish 09/30/2022 Original
009-82 Installation of Equal Component Vice Specified Component; report 09/27/2022 Original
009-84 Threaded Fastener Requirements; accomplish 09/30/2022 Original
009-88 Collection, Holding and Transfer (CHT) and Motor Gasoline (MOGAS) Tanks, Spaces, and Piping, including Sewage or MOGAS-Contaminated Tanks, Spaces, and Piping; certify
09/27/2022 Original
009-93 Emergency Planning and Community Right-to-Know Act (EPCRA) and Pollution
Prevention Act (PPA) Information; provide
09/27/2022 Original
009-99 Ship Departure Report; provide 09/27/2022 Original
ITEM_NO. TITLE CHANGE DATE CHANGE
009-100 Ship's Stability; maintain 09/30/2022 Original
009-101 Ship Transit and Berthing; accomplish 09/27/2022 Original
009-106 Work Authorization Form Coordinator (WAFCOR); provide 09/27/2022 Original
009-109 Non-SUBSAFE Work on SUBSAFE-Certified Vessel; accomplish 09/27/2022 Original
009-110 Non-Nuclear Work on a Nuclear Vessel; accomplish 09/27/2022 Original
009-111 Schedule and Associated Reports for non-CNO Availabilities; provide and manage
09/30/2022 Original
009-117 Combat Systems, Light-Off Suport; provide 09/30/2022 Original
009-118 CG Deck Loading; accomplish 09/27/2022 Original
009-120 Fact Finding and Critique of Unplanned Event; manage 09/30/2022 Original
009-122 Temporary Padeye; install and remove 09/30/2022 Original
009-125 Boats Less Than 65 Feet Long; accomplish 10/25/2022 Original
099-01PH Waste Generated on Government Property, including Satellite Accumulation area (SAA), Managing and Disposing of Hazardous Waste (HW) and non-HW;
accomplish
01/20/2023 Original
099-02PH Dry Dock Requirement; accomplish 01/20/2023 Original
099-03PH Additional Environmental Requirements; accomplish 01/20/2023 Original
099-04PH Industrial Wastewater/Oily Wastewater Disposal; accomplish 01/20/2023 Original
099-007PH Radiological Fallout Controls; accomplish 07/13/2023 CH-3
099-08PH Safety of Ship Requirement; provide 01/17/2023 Original
099-40PH Additional Requirements for Contractor Cranes, Multi-Purpose machine, and
Material Handling Equipment at Joint Base Pearl Harbor Hawaii; accomplish
01/17/2023 Original
099-69PH Pier Laydown for Pearl Harbor Naval Shipyard & IMF (PHNSY & IMF)
Availability; accomplish
07/06/2023 CH-2
CATEGORY II. FY-24 STANDARD ITEMS WHICH MAY BE INVOKED IN THE WORK ITEMS OF THIS JOB ORDER.
TITLE CHANGE DATEITEM NO. CHANGE
009-11 Insulation and Lagging; accomplish 09/27/2022 Original
009-12 Weld, Fabricate, and Inspect; accomplish 09/27/2022 Original
009-25 Structural Boundary Test; accomplish 09/29/2022 Original
009-32 Cleaning and Painting Requirements; accomplish 09/29/2022 Original
009-90 Technical Representative; provide 09/27/2022 Original
ITEM NO. TITLE
Hazardous Waste Produced on Naval Vessels; control077-11-001
Deck; replace150-11-001
Barge Dial Telephone System, One MC Announcing System; inspect and groom
432-11-001
Firemain; inspect and test521-11-001
Potable Water Pressure Gauge; Remove, Calibrate and Install533-11-001
Aqueous Potassium Carbonate (APC) Fire Extinguishing System; inspect555-60-001
Accommodation Ladder; inspect and test611-11-001
Windows; repair624-11-001
Deep Clean; accomplish992-11-001
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 077-11-001
COAR: 16 PCN:
CMP:
PLANNER:
SERV-L108
NONE
SSP: HRMC-008-24 1 of 5 ITEM NO: 077-11-001
1. SCOPE:
1.1 Title: Hazardous Waste Produced on Naval Vessels; control
1.2 Location of Work:
1.2.1 Throughout the Ship
1.3 Identification:
1.3.1 Not Applicable
2. REFERENCES:
2.1 Resource Conservation and Recovery Act (RCRA)
2.2 Federal Hazardous Materials Transportation Act, 49 U.S.C. 5103
2.3 Applicable Hazardous Waste Manifest Form
2.4 10 U.S.C. 7311
3. REQUIREMENTS:
3.1 Manage and dispose of all hazardous waste listed in 3.5 in accordance with 2.1 and 2.2.
3.1.1 When a Navy generator number is required by this Work Item, submit the original of 2.3 to the SUPERVISOR for assignment of Environmental Protection Agency (EPA) or delegated state environmental agency identification number.
3.1.2 Manage and transport for Navy disposal, Navy-generated
hazardous waste listed in 3.5 in accordance with 2.1 and 2.2, as designated by the SUPERVISOR.
3.1.3 Submit one legible copy of 2.3 signed by the owner or operator of the disposal facility to the SUPERVISOR within 48 hours of receipt from owner or operator of disposal facility.
3.2 Complete documentation required by 2.1 and 2.2, using EPA or delegated state environmental agency identification number in accordance with 2.4.
3.2.1 Documentation related to hazardous waste generated solely by the physical actions of Ship's Force or Navy employees (termed Navy- Generated Hazardous Waste) on board the vessel shall only bear a generator identification number issued to the Navy pursuant to applicable law. The contractor shall obtain SUPERVISOR'S concurrence with the categorization of the waste as Navy-generated before completion of the manifest. The manifest prepared shall be presented to the SUPERVISOR for completion after the hazardous waste has been identified.
3.2.2 Documentation related to hazardous waste generated solely by the physical actions of contractor personnel (termed Contractor- Generated Hazardous Waste) shall bear a generator identification number issued to the contractor pursuant to applicable law.
Regardless of the presence of other material in or on the shipboard systems or structure which may have qualified a waste stream as hazardous, where the contractor performs work on a system or
SHIP: YRBM 32 (YRBM 13204)
SSP: HRMC-008-24 2 of 5 ITEM NO: 077-11-001 structure using materials (whether or not the use of such materials was specified by the Navy) which by themselves would cause the waste from such work to be a hazardous waste, documentation related to such waste shall only bear a generator number issued to the contractor.
3.2.3 Documentation related to hazardous waste generated by the combined physical actions of Navy and contractor personnel (termed Co-Generated Hazardous Waste) shall bear a generator identification number issued to the contractor pursuant to applicable law and shall also cite in the remarks block a generator identification number issued to the Navy pursuant to applicable law. When the contractor merely drains a system and such drainage creates hazardous waste or the contractor performs work on system or structure using materials which by themselves would not cause the waste from such work to be hazardous waste but such work nonetheless creates a hazardous waste, documentation related to such waste shall bear a generator identification number issued to the contractor and shall also cite in the remarks block a generator identification number issued to the Navy. The contractor shall sign the generator certification on the Uniform Hazardous Waste Manifest whenever use of the manifest is required for disposal. The contractor shall obtain SUPERVISOR's concurrence with the categorization of the wastes as co-generated before completion of the manifest. Manifests prepared shall be presented to the SUPERVISOR for completion after the hazardous waste has been identified.
3.3 If the contractor, while performing work at a Government facility, cannot obtain a separate generator identification number from the state in which the availability will be performed, the contractor shall notify the SUPERVISOR within three business days of receipt of written notification by the state. After obtaining approval of the SUPERVISOR, the contractor shall use the Navy site generator identification number and insert in the remarks block the contractor generator identification number issued for the site where his main facilities are located.
3.4 If, for availabilities at a contractor-owned or controlled facility, the Navy cannot obtain a separate generator identification number for use at a contractor facility, the Navy shall notify the contractor within three business days of receipt of notification by the state. The contractor shall dispose of hazardous waste in accordance with 2.1, 2.2, and 3.2.3.
3.5 Hazardous waste, as identified in 2.1, expected to be produced during performance of this Job Order:
AMOUNT
TYPE NAVY CO-GENERATED CONTRACTOR
Acid Solutions (may include _____ ____________ __________ spent sulfamic, citric, chromic, nitric, sulfuric, hydrochloric, etc.)
Ethylene Glycol (Antifreeze) _____ ____________ __________
Sodium Hydroxide _____ ____________ __________
Cleaning Solvents _____ ____________ __________
SSP: HRMC-008-24 3 of 5 ITEM NO: 077-11-001
Sodium Phosphates (Tri, Bi, _____ ____________ __________ or Mono)
Fluorocarbons _____ ____________ __________
Morpholine _____ ____________ __________
Sodium Chromates _____ ____________ __________
Hydrazine _____ ____________ __________
Methyl Ethyl Ketone _____ ____________ __________
Spent Abrasive Blast Material _____ ____________ __________
(contaminated with a known hazardous waste)
Trichloroethane _____ ____________ __________
Miscellaneous Chemicals _____ ____________ __________
(Rust Preventative)
Miscellaneous Chemicals _____ ____________ __________
(Corrosive)
Miscellaneous Chemicals _____ ____________ __________
(TCLP Toxic)
Miscellaneous Chemicals _____ ____________ __________
(Reactive)
Oil (Synthetic) _____ ____________ __________
Paints (Enamel, Latex, _____ ____________ __________
Epoxy, thinners, oil based, rubber paint, non-skid, lacquer, remover, varnishes)
Paints (May include lead, _____ ____________ __________ cadmium, or chrome)
Paint Strippers (phenols, _____ ____________ __________ lead, chromium)
Sludges (Contaminated with _____ ____________ __ a known hazardous waste)
Wool Felt (contaminated _____ ____________ __________ with chromium and PCB's)
Lube/Fuel Oil Soaked Rags _____ ____________ __________
Paint/Flakes (Pressure Washing _____ ____________ __________
Ext Hull Surfaces)
Fuel Oil(Residual) _____ ____________ __________
Bilge Water _____ ____________ __________
SSP: HRMC-008-24 4 of 5 ITEM NO: 077-11-001
Oil/Water _____ ____________ __________
AFFF/Water _____ ____________ __________
MEK Contaminated Rags _____ ____________ __________
3.5.1 Provide zero dollars for managing and disposing of all
hazardous waste listed in 3.5. Total cost greater or less than above dollar amount will be the subject of an equitable adjustment.
3.6 Submit one legible copy, in approved transferrable media of a report identifying type, amount, and disposal cost of waste listed in 3.5 that was removed during the performance of this Job Order to the SUPERVISOR.
3.6.1 The report shall include analysis or other method used to identify the waste and state whether each listed waste was hazardous (with generator assignment), non-hazardous, or did not exist.
3.6.1.1 Chemical analysis shall be accomplished by laboratories with state or EPA approved quality assurance programs.
3.6.2 The contractor shall make an effort to minimize hazardous waste generation by reducing the volume or toxicity by neutralizing, recycling, or otherwise removing it from the requirements of Subtitle C of 2.1 and include a description of such efforts in the report.
3.7 Nothing contained in this Work Item shall relieve the contractor from complying with applicable federal, state, and local laws, codes, ordinances, and regulations, including the obtaining of licenses and permits in connection with hazardous waste handling and disposal in the performance of this contract.
4. NOTES:
4.1 The waste listed in 3.5 is based on the best information available at the time of preparation of the solicitation. Hazardous waste generated during the actual performance of the work may vary in type or amount from waste listed in 3.5 which may result in renegotiation for credit or increase pursuant to Paragraph (b) of 2.4. The contractor is expected to use best management practice to identify and dispose of all hazardous waste. Some of the substances listed in 3.5 may be neutralized, recycled, or otherwise removed from the requirements of Subtitle C of 2.1. Inclusion of these substances in the waste listed in
3.5 does not preclude the contractor from taking action consistent with
2.1 to reduce or eliminate the hazardous constituents of any waste required to be disposed of under the contract in accordance with 2.2.
Processes that add hazardous constituents to the bilges may require that bilge water be disposed of as a hazardous waste.
4.1.1 The types and amounts of wastes listed in 3.5 are estimates of waste to be disposed of under this contract as required by 2.4. They are not estimates of the amount of the work involved in generating that waste. The work requirements of each individual Work Item specify the actual work to be accomplished.
4.2 Hazardous wastes are determined by one or more of the following methods:
4.2.1 Chemical analysis which shows that the material
characteristics of ignitability, corrosivity, reactivity, and/or toxicity (Toxicity Characteristic Leachate Procedure - TCLP) exceed the limits for that material in 40 CFR 261.20 Subpart C.
SSP: HRMC-008-24 5 of 5 ITEM NO: 077-11-001
4.2.2 Reference to a Material Safety Data Sheet (MSDS), or
4.2.3 Applying knowledge of the hazardous characteristics of the waste in light of the materials or the process used.
4.3 Asbestos, bilge water, oil/water including sludge, debris and other contaminants, sludge which includes solids and sludge from ballast tanks, CHT tanks, voids, oily waste tanks, fuel ballast tanks, fuel oil tanks, skegs (West coast), PCB's (Maryland), etc., apply only in those states listing them as hazardous waste. When an availability is to be performed in a state where these items are hazardous waste, an estimate of the amount to be generated shall be included in 3.5.
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
1. None.
5.3 KITTED MATERIAL:
1. None.
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 150-11-001
COAR: 16 PCN: SERV-L110
SERV-L114
SERV-L109
CMP:
PLANNER:
NONE
SSP: HRMC-008-24 1 of 2 ITEM NO: 150-11-001
1. SCOPE:
1.1 Title: Deck; replace
1.2 Location of Work:
1.2.1 01 Level, Quarter Deck Vestibule, Frame 71 - 73
1.2.2 03 Level, Port (Between frames 4-13) And Stbd (Frames 13-17)
1.2.3 04 Level, Fwd (04-1-1) And Aft (04-16-1)
1.3 Identification:
1.3.1 Not Applicable
2. REFERENCES:
2.1 Standard Items, (FY-24)
2.2 111-7647102, Quarter Deck and Platform 01 Level
2.3 138-5478229, 03 and 04 Levels Deck Structure
2.4 612-5478295 Rev F, Rails, Lifelines and Stanchions (Plan 12E and 17E)
3. REQUIREMENTS:
3.1 Crop out a total of 50 square feet of deteriorated steel decking near the quarter deck and accom ladder located in 1.2.1, and replace with new 7.65# plating, using 2.2 for guidance.
3.1.1 Template exact size, configuration, and location from existing shipboard conditions.
3.1.2 Chip and grind surfaces flush in way of repairs.
3.2 Crop out a total of 100 square feet of deteriorated decking on the 03 level, portside between frames 4-13. Also crop out an total of 200 square feet of deteriorated decking on the 03 level, stbd at frames 13- 17, located in 1.2.1. Replace with new CRES plating, using 2.3 for guidance.
3.2.1 Template exact size, configuration, and location from existing shipboard conditions.
3.2.2 Chip and grind surfaces flush in way of repairs.
3.3 Crop out a total of 50 square feet of deck plating on the 04 level fwd, 04-1-1 and approximately 75 square feet of deck plating aft, 04-16- 1, located in 1.2.1. Replace with new 7.65# plating, using 2.4 for guidance.
3.3.1 Template exact size, configuration, and location from
existing shipboard conditions.
3.3.2 Chip and grind surfaces flush in way of repairs.
3.4 Accomplish the requirements of 009-12 of 2.1, including Table 3, SSP: HRMC-008-24 2 of 2 ITEM NO: 150-11-001
Column A, Lines One through 7.
3.5 Accomplish the requirements of 009-25 of 2.1 for the local air hose test of each new insert plating installed in 3.1. Allowable leakage:
None.
3.6 Accomplish the requirements of 009-32 of 2.1, for all new and disturbed surfaces.
4. NOTES:
4.1 None
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
1. None.
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 432-11-001
CMP:
PLANNER:
SERV-L118
NONE
SSP: HRMC-008-24 1 of 2 ITEM NO: 432-11-001
1. SCOPE:
1.1 Title: Barge Dial Telephone System, One MC Announcing System;
inspect and groom
1.2 Location of Work:
1.2.1 Throughout Barge
1.3 Identification:
1.3.1 Not Applicable
2. REFERENCES:
2.1 Standard Items, (FY-24)
2.2 432-5478250 Rev E, Barge Telephone System
2.3 432-6904785, Dial Telephone System Circuit J
2.4 432-8429881, Dial Telephone System CKT J
2.5 432-8429882, Telephone System Spec
2.6 433-5478251 Rev E, Public Address System
2.7 433-8429883, Gen Ann Sys CKT 1MC
3. REQUIREMENTS:
3.1 Accomplish the requirements of 009-90 of 2.1 for services provided by an authorized OEM representative to inspect, groom and test the existing telephone and one MC system, using 2.2 through 2.6 for guidance.
(V)(G) "OPERATIONAL TEST"
3.2 Accomplish an operational test of the Dial Telephone "CKT J" and One MC system, using 2.2 through 2.7 for guidance. Record results
3.2.1 Call to and from each telephone to verify proper transmission and receiving from each telephone set.
3.2.2 Submit one legible copy, in approved transferrable media, of completed operational test results to the SUPERVISOR.
3.3 Accomplish the requirement of 009-32 of 2.1 for each new and disturbed surface.
4. NOTES:
5. GOVERNMENT FURNISHED MATERIAL(GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
SSP: HRMC-008-24 2 of 2 ITEM NO: 432-11-001
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 521-11-001
CMP:
PLANNER:
SERV-L117
NONE
SSP: HRMC-008-24 1 of 2 ITEM NO: 521-11-001
1. SCOPE:
1.1 Title: Firemain; inspect and test
1.2 Location of Work:
1.2.1 Throughout Barge
1.3 Identification:
1.3.1 Quantity (One EA): Fire and Flood Alarm System
1.3.2 Quantity (3 EA): Fire Station Sign, 11" x 17" in size
2. REFERENCES:
2.1 Standard Items, (FY-24)
2.2 436-5478253 Rev F, Alarm System
2.3 436-7646647, Fire and Flooding Alarm System Installation
2.4 436-8429879 Rev A, Fire and Flooding Alarm System CKT F & FD
2.5 436-8429880, Fire and Flooding Alarm Specification
3. REQUIREMENTS:
3.1 Accomplish the requirements of 009-90 of 2.1 to provide the services of a qualified technical representative to accomplish testing, troubleshooting, and reprogramming of the Fire and Flooding Alarm System located in 1.2, listed in 1.3, using 2.2 through 2.5 for guidance.
3.1.1 The technical representative shall be an Original Equipment Manufacturer (OEM) of the existing type of Fire and Flooding System.
3.1.1.1 Submit one legible copy, in electronic media, of a
report listing the results of 3.1. Report shall include repair recommendations, material requirements, material and labor cost, and material availability.
(V)(G) "OPERATIONAL TEST"
3.2 Accomplish an operational test of the repaired Fire and Flooding Alarm Systems to ensure that equipment functions to designed sequence of operation in accordance with 2.2 through 2.5.
3.2.1 Circuits shall be inspected and verified for correct fusing, phasing and circuit breakers. Record results.
3.2.2 Indicator lights shall show and maintain a bright and steady glow when activated, alarms shall sound in main and remote locations as required. Record results.
3.2.2.1 Submit one legible copy, in electronic media, of a
report listing the results of 3.2 to the SUPERVISOR, within 48 hours of test completion. Report shall include a list of devices tested and their location.
3.3 Provide a total of 4 hours of systems operational training to the Berthing and Messing Program personnel on the operation and functioning
SSP: HRMC-008-24 2 of 2 ITEM NO: 521-11-001 of the Fire and Flooding system, listed in 1.3, upon completion of 3.2.
3.4 Accomplish the requirements of 009-32 of 2.1 for new and disturbed surfaces to match surrounding areas.
4. NOTES:
4.1 None
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
1. None.
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 533-11-001
CMP:
PLANNER:
SERV-L113
NONE
SSP: HRMC-008-24 1 of 2 ITEM NO: 533-11-001
1. SCOPE:
1.1 Title: Potable Water Pressure Gauge; Remove, Calibrate and Install
1.2 Location of Work:
1.2.1 Main Deck, Stbd Side at Frame 8
1.3 Identification:
1.3.1 Quantity (One EA), Pressure Gauge, 4 1/2" Dial, 0-100 PSI
2. REFERENCES:
2.1 STANDARD ITEMS, (FY-24)
2.2 530-547829 Rev B, Fresh Water Main Deck
2.3 MIL-STD-777, Schedule of Piping, Valves, Fittings, and Associated Piping Components for Naval Surface Ships
3. REQUIREMENTS:
3.1 Isolate potable water system and remove pressure gauge listed in
1.3.1 and located in 1.2.1, using 2.2 for guidance.
3.1.1 Remove and dispose of fluids in accordance with federal, state, and local laws, codes, ordinances and regulations.
3.1.2 Calibrate pressure gauge, listed in 1.3.1, using certified, test equipment and competent test personnel. Affix new calibration sticker in place of outdated sticker.
3.1.3 Reinstall newly calibrated pressure gauge, using 2.2 for guidance.
(V)(G) "OPERATIONAL TEST"
3.2 Accomplish an operational test for newly calibrated pressure gauge at system normal operating pressure and temperature, proving proper operation and zero leakage.
3.2.1 Submit one legible copy, in electronic media, of a report listing results of the requirements of 3.2 to the SUPERVISOR.
3.3 Accomplish the requirement of 009-32 of 2.1 for new and disturbed surface.
4. NOTES:
4.1 None
5. GOVERNMENT FURNISHED MATERIAL(GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
SSP: HRMC-008-24 2 of 2 ITEM NO: 533-11-001
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 555-60-001
CMP:
PLANNER:
SERV-L115
NONE
SSP: HRMC-008-24 1 of 2 ITEM NO: 555-60-001
1. SCOPE:
1.1 Title: Aqueous Potassium Carbonate (APC) Fire Extinguishing System;
inspect
1.2 Location of Work:
1.2.1 Galley (1-49-2-Q)
1.3 Identification:
1.3.1 Quantity (One EA): Aqueous Potassium Carbonate (APC) Fire Extinguisher
2. REFERENCES:
2.1 Standard Items, (FY-24)
2.2 507-6735264 Rev A, Fire Extinguishing System APC System Deep Fat Fryer
2.3 MN-6870 Gaylord, Gaylord Fail Safe Control Cabinet Schematic
2.4 DOD-STD-2003 , Electronic Plant Installation Standard Methods for Surface Ships and Submarines
3. REQUIREMENTS:
3.1 Disconnect mechanically and remove the existing equipment listed in 1.3, located in 1.2.1 and using 2.2 for guidance.
3.1.1 Procure and install each new APC fire extinguisher bottle and nitrogen bottle in accordance with manufacturer instructions and using 2.2 for guidance. Each new bottle shall be of equal or larger size capacity than existing. Modify all existing piping, tubing, fittings, and mounting brackets to suit new APC and nitrogen bottles.
Upon satisfactory installation and pressure test, fill each bottle with its’ respective ingredients.
3.1.1.1 Replace existing and install new 3 each link for the
equipment installed in 3.1.1 using 2.2 for guidance. Ensure each link is fusible.
3.1.2 Obtain the services of a qualified technical representative to remove, modify, install, test and certify the APC System.
(V)(G) "OPERATIONAL TEST"
3.2 Accomplish an operational test of the equipment installed in 3.1 to ensure equipment functions to designed sequence of operation, in accordance with manufacturer's instructions supplied with equipment and using 2.3 for guidance. Ensure associated dampers close and ventilation shuts down, within the immediate area, when the APC system is activated.
3.2.1 Submit one copy, in approved transferrable media, of the results of 3.2 and document(s) of official APC system certification to the SUPERVISOR.
3.3 Accomplish the requirements of 009-32 of 2.1 for each new and
SSP: HRMC-008-24 2 of 2 ITEM NO: 555-60-001 disturbed surface.
4. NOTES:
4.1 None
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
1. None.
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 611-11-001
CMP:
PLANNER:
SERV-L111
NONE
SSP: HRMC-008-24 1 of 2 ITEM NO: 611-11-001
1. SCOPE:
1.1 Title: Accommodation Ladder; inspect and test
1.2 Location of Work:
1.2.1 01 Level, Exterior, Starboard, Forward of Quarter Deck
1.2.2 03 Level, Frame 61
1.3 Identification:
1.3.1 Quantity (One EA): Accommodation Ladder Assembly
2. REFERENCES:
2.1 Standard Items, (FY-24)
2.2 603-7647123, Accommodation Ladder Installation
2.3 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods
3. REQUIREMENTS:
3.1 Accomplish a visual inspection of the accommodation ladder assembly listed in 1.3 and located in 1.2, including each load-bearing joint and fastener.
3.1.1 Submit one legible copy, in electronic media, of a report listing results of the requirements of 3.1 to the SUPERVISOR. The report shall include a detailed sketch of each exact location requiring repair or replacement.
(I) "NON DESTRUCTIVE TESTING"
3.2 Accomplish non-destructive testing (Visual Test VT) on each weld of the accommodation ladder listed in 1.3, located in 1.2, and all associated components. Testing shall be accomplished in accordance with 2.3.
3.2.1 Submit one legible copy, in electronic media, of a report listing results of the requirements of 3.2 to the SUPERVISOR.
3.3 Accomplish the requirements of 009-32 of 2.1 for each new and disturbed surface.
4. NOTES:
4.1 None
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
SSP: HRMC-008-24 2 of 2 ITEM NO: 611-11-001
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 624-11-001
CMP:
PLANNER:
SERV-L126
NONE
SSP: HRMC-008-24 1 of 1 ITEM NO: 624-11-001
1. SCOPE:
1.1 Title: Windows; repair
1.2 Location of Work:
1.2.1 Throughout the Barge
1.3 Identification:
1.3.1 Quantity (70 Each): Exterior Window, Fixed, Clear Opening - 23-3/8" W x 32-3/8" H, Item 1 of 2.2
2. REFERENCES:
2.1 Standard Items, (FY-24)
2.2 625-5478302 Rev D, Windows
3. REQUIREMENTS:
3.1 Reseal windows identified in 1.3.1, in area 1.2, in accordance with 2.2.
3.1.1 Remove existing caulking or rubber around the interior and exterior of each window.
3.1.2 Clean and prepare the area prior to resealing.
3.2 Accomplish the requirements of 009-25 of 2.1 for the water hose test of each newly sealed window. Allowable leakage: None.
3.3 Accomplish the requirements of 009-32 of 2.1 for disturbed areas.
4. NOTES:
4.1 None.
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
1. None.
SHIP: YRBM 32 (YRBM 13204) ITEM NO: 992-11-001
CMP:
PLANNER:
SERV-L116
NONE
SSP: HRMC-008-24 1 of 3 ITEM NO: 992-11-001
1. SCOPE:
1.1 Title: Deep Clean; accomplish
1.2 Location of Work:
1.2.1 Throughout all interior spaces
1.3 Identification:
1.3.1 Not Applicable.
2. REFERENCES:
2.1 Standard Items, (FY-24)
3. REQUIREMENTS:
3.1 Accomplish the requirements to deep clean and sanitize all spaces located in 1.2, using Occupational Safety and Health Administration approved disinfectant products and materials.
3.1.1 Clean all horizontal and vertical spaces, corners, crevices, and equipment / furniture surfaces to remove all of oil, grease, food deposit, human waste/hair, grime, dirt, lime, scale, soap scum, water mineral deposits, debris and sanitize as follows:
3.1.1.1 Typical surfaces to clean and sanitize includes but not limited to tables, chairs, doorknobs, light switches, countertops, handles, toilets, faucets, sinks, and rails.
3.1.1.2 Deep clean, scrub, and sanitize water closets and shower stall areas.
3.1.1.3 All interiors, galley / scullery equipment including
reefer flats and sanitary spaces shall include scrubbing, cleaning and sanitization of all surfaces, de-liming and de-scaling of tile; toilets, sinks, baths, showers. Walk-in combination cooler and freezer shall be defrosted, cleaned and sanitize in a similar manner. Upon satisfactory cleanliness inspection, wrap and secure equipment with plastic wrap to prevent accidental opening and contamination.
3.1.1.4 Inspect and deep clean Gaylord Hood system.
3.1.1.5 The griddle in the Galley shall be scraped clean of all oil, grease, carbonized food remnant. Top surface shall be scoured using a griddle stone to bare metal surface. Upon satisfactory cleanliness inspection, apply a film of cooking oil over entire surface and cover with plastic wrap. Do not use steel wool to clean.
3.1.1.6 All deck surfaces shall be vacuumed, mopped, and waxed.
All inclined ladder assemblies shall be vacuumed and wiped clean.
3.1.1.7 All mirrors and interior sides of windows shall be wiped clean and polished with glass cleaner.
3.1.1.8 All living and berthing spaces, passageways, lounges, recreation spaces, offices and other support spaces, vestibules and entryways vacuumed, mopped and waxed, mirrors polished. Deep
SSP: HRMC-008-24 2 of 3 ITEM NO: 992-11-001 clean and scrub cupboards, wardrobes, inside windows, fixtures, framework, ledges, sills, and their doors.
3.1.1.9 Special care must be taken around energized electrical equipment to prevent any damage to electrical equipment and to prevent electric shock to personnel. Do not spray any liquid on any electrical appliance cooling fan, motor, exposed wiring or connections.
3.1.1.10 Follow the cleaning product manufacturer’s directions.
Rags used for wiping surfaces shall be changed for every new space or when they have been soiled. Rags shall not be re-used unless they have been washed and sanitized.
3.1.1.11 Vacuum clean and shampoo all Barge carpeting and mats, furniture (sofas, loveseats, chairs, etc.) and clean all air diffusers free of dust and debris.
3.1.2 Remove and dispose of all generated waste in accordance with federal, state, and local laws, codes, ordinances, and regulations.
3.2 Replace all air handling Unit (AHU) Filters.
3.3 Replace up to 20 EA broken or damaged ceiling panels and tiles. Turn over unused panels to the Barge Program
3.4 Remove existing and install new components as specified below:
3.4.1 A total of 10 each CD-X-10 Series locks or equal. Turn over unused locks to the SUPERVISOR. Combination shall be set to the numbers chosen by BARGE PROGRAM SUPERVISOR.
(V)(G) "OPERATIONAL TEST"
3.4.1.1 Accomplish an operational test of all newly installed combination locks installed in 3.5.1. Unlock and lock through 4 compete cycles. Allowable sticking or binding: None.
(V)(G) "CLEANLINESS INSPECTION"
3.5 Accomplish a joint visual inspection with the SUPERVISOR of each space listed in 1.2 for verification of cleanliness. Degree of cleanliness shall be determined by rubbing or wiping a surface designated by the SUPERVISOR using a white cotton glove provided by the Contractor.
After wiping, the glove shall be observed for any evidence of residue having been left on the surface being tested. Criteria: All areas shall be turned over in a clean, sanitized and dry condition. No dirt, debris, garbage, and waste shall be present and or visible on the white glove used.
3.5.1 Develop a spreadsheet / check sheet / map of entire interior of the barge to indicate completion of areas cleaned for tracking purposes with provision for GOVERNMENT signature. After a work space or habitability space has been considered cleaned and sanitized the Contractor shall place a placard on the bulkhead/door stating cleaning is complete, space has been turned over, and no one is allowed into the space. Only GOVERNMENT and or Barge Maintenance Program personnel will have the option to lock and or enter the space.
3.6 Accomplish the requirements of 009-32 of 2.1 for new and disturbed surfaces.
SSP: HRMC-008-24 3 of 3 ITEM NO: 992-11-001
4. NOTES:
4.1 None.
5. GOVERNMENT FURNISHED MATERIAL(GFM):
5.1 LLTM:
1. None.
5.2 PUSH MATERIAL:
1. None.
File details come from the government source that posted it. Updated .