This document is a Request for Quotation (RFQ) for a High Pressure Milk Homogenizer. The U.S. Department of Agriculture, Agricultural Research Service in Athens, GA has a requirement for a homogenizer that meets the specified technical requirements, including a 400 bar minimum pressure, 0.5L minimum sample volume, and 8-50L/hr flow rate. The RFQ provides details on the required features, delivery, and pricing terms. Offerors must submit a quote on company letterhead and complete the FAR 52.212-3 Offeror Representations and Certifications. The evaluation will be based on technical capability, past performance, and price, with technical and past performance more important than price. Quotes are due by 4:00 PM CST on June 25, 2024, and the government anticipates awarding a firm-fixed-price contract to the responsible offeror whose offer is most advantageous.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Clauses and Provisions (supply Solicitation).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Homogenizer specs
Salient Characteristics The homogenizer must use a high-pressure piston (1-stage) or pistons (2-stage) to homogenize fluid dairy products to standard industrial specifications in the United States. The unit must be able to operate stand-alone (includes and necessary tubing for fittings for stand-alone operation). The unit must be made with FDA approved materials and gaskets. The design must accommodate clean-in-place and sterilize-in-place operation with a sterilization temperature minimum of 90°C.
Specifications Capacity:
· Minimum sample volume no more than 0.5L
· Variable capacity flow rate required so that the range maximum is no less than: 8L/hr and the range minimum is no more than 50L/hr. For example, the flow rate must be able to be adjusted to be at least 8L or under 50L/hr.
· Hopper included with a capacity minimum of 2.5L
Utilities:
· Must be configured to run on 3phase, 480V, 50amp circuit
· Must not require a water source
Pressure:
· Minimum 400bar