Homogenizer specs.docx

DOCX document 16 KB Posted

Attached to
High Pressure Milk Homogenizer Federal contract opportunity
Solicitation number
12405B24Q0254
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery

About this file

This document is a Request for Quotation (RFQ) for a High Pressure Milk Homogenizer. The U.S. Department of Agriculture, Agricultural Research Service in Athens, GA has a requirement for a homogenizer that meets the specified technical requirements, including a 400 bar minimum pressure, 0.5L minimum sample volume, and 8-50L/hr flow rate. The RFQ provides details on the required features, delivery, and pricing terms. Offerors must submit a quote on company letterhead and complete the FAR 52.212-3 Offeror Representations and Certifications. The evaluation will be based on technical capability, past performance, and price, with technical and past performance more important than price. Quotes are due by 4:00 PM CST on June 25, 2024, and the government anticipates awarding a firm-fixed-price contract to the responsible offeror whose offer is most advantageous.

View the file

Other files for this federal contract opportunity

Other files attached to High Pressure Milk Homogenizer, newest first.
File Type Posted
Clauses and Provisions (supply Solicitation).pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Homogenizer specs

Salient Characteristics The homogenizer must use a high-pressure piston (1-stage) or pistons (2-stage) to homogenize fluid dairy products to standard industrial specifications in the United States. The unit must be able to operate stand-alone (includes and necessary tubing for fittings for stand-alone operation). The unit must be made with FDA approved materials and gaskets. The design must accommodate clean-in-place and sterilize-in-place operation with a sterilization temperature minimum of 90°C.

Specifications Capacity:

· Minimum sample volume no more than 0.5L

· Variable capacity flow rate required so that the range maximum is no less than: 8L/hr and the range minimum is no more than 50L/hr. For example, the flow rate must be able to be adjusted to be at least 8L or under 50L/hr.

· Hopper included with a capacity minimum of 2.5L

Utilities:

· Must be configured to run on 3phase, 480V, 50amp circuit

· Must not require a water source

Pressure:

· Minimum 400bar