ADDITIONAL REQUIREMENTS FOR HC101318QA684
***ATTENTION EBBING (FT SMITH) LOCATION***
1. THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END TO THE GOVERNMENT'S SERVICE
DELIVERY POINTS (SDP'S) FROM TSR SF02FEB185942;
MEANING THAT THE PHYSICAL PATHS ARE TOTALLY SEPARATE
INCLUDING MAN HOLES, CONDUIT, (CENTRAL OFFICE
LOCATIONS), AND FIBER BUILDS. ADDITIONALLY AS A
MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM
TSR SF02FEB185942.
2. TELECOMM PROVIDER MUST PROVIDE DISA COLOR POWERPOINT
DRAWINGS FORTECHNICAL REVIEW SHOWING THE ROUTES FROM
THE COMMERCIAL DEMARCS TO THE SUPPORING CENTRAL
OFFICES AND OR WIRING CENTERS ENSURING THE PHYSICAL
END TO END DIVERSITY REQUIREMENTS ARE BEING MET.
DRAWINGS ALSO TO INCLUDE SEPARATION DISTANCES,
TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY
MUST PROVIDE COLOR CODED MAPS AND MUST BE RED LINED
SHOWING HOW THE CIRCIT WILL BE ROUTED END TO END FROM
THE CUSTOMER A LOCATON TO THE CUSTOMER Z LOCATION.
3. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES.
4. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES.
5. 2.5GB WAVE SERVICE MUST BE ENGINEERED/PROVISIONED IN
SUCH A WAY THAT THE GOVERNMENT CAN CHANGE/REVISE
CHANNELIZATION WITHOUT TELECOMM PROVIDER INTERVENTION.
A. NOTE 1 (JITTER).: IN A STEADY-STATE CONDITION,
THE PATTERN OF SYNCHRONOUS TRANSPORT SIGNAL (STS)
POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH
THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE NO
MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH
THE DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI
T1.105.03-1994) THAN THE POINTER ADJUSTMENT
SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING
TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2
TIMES PER DAY), THE PATTERN OF STS POINTER
ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH THE
SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR
OR LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME
INTERVAL ERROR (MTIE) OVER A PERIOD OF S SECONDS,
OR WANDER, SHALL NOT EXCEED (.01S + 10000)
NANOSECONDS FOR VALUES OF S GREATER THAN 10,000.
B. WAVELENGTH TRANSMISSION SERVICES:
WAVELENGTH TRANSMISSION SERVICES FOR RATES
OF 2.5GBPS SHALL BE IN ACCORDANCE WITH ITU-T
RECOMMENDATIONS G.709(03/2003), G.707(12/03),
G.957(03/06), G.692(10/98) & TELCORDIA GR253-NS6.
THE PROVIDED WAVELENGTH TRANSMISSION SERVICE
SHALL NOT INHIBIT GOVERNMENT OPERATION OF
UNDERLYING PROTOCOLS AND TRANSPORT SYSTEMS
SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP,
ATM, GIGABIT ETHERNET, AND ENCRYPTION. THE
WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL
PASS ALL PAYLOAD, PATH AND LINE OVERHEAD BYTES
TRANSPARENTLY (UNTOUCHED/UNALTERED) AND WITHOUT
MONITORING SDP TO SDP. THERE SHALL NOT BE ANY
LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP
AND SDP.
C. 2.5GB WAVE SERVICE MUST BE TERMINATED TO THE LINE
SIDE OF THE FIBER TERMINATING PATCH PANEL
INSTALLED IN THE DISA IE1 PROVIDED ODXC SUITE AT
SCOTT AFB AND THE FIBER TERMINATING PATCH PANEL
INSTALLED IN THE DISA IE1 PROVIDED ODXC SUITE
INSTALLED AT EBBING ANGB.
D. TELECOMM PROVIDER MUST CONTACT DISA CONUS TIER-II
ODXC ENGINEERING UPON RECEIPT OF A VALID TSO TO
ESTABLISH THE COORDINATION AND ACTIVATION PROCESS.
PRI POC: CONTACT: MIKE REEVES
(C) 618-220-8973 (D) 770-8973
ALT POC: CONTACT: DAMION SCANDRICK
(C) 618-220-9634 (D) 770-9634
ALT POC: CONTACT: AARON SMITH
(C) 618-220-9820 (D) 770-9820
ALT POC: CONTACT: BOB RISKY
(C) 618-220-8632 (D) 770-8632
ALT POC: ORGANIZATIONAL NUMBER
(C) 618-220-8691 (D) 770-8691
6. ONCE TELECOMM PROVIDER HAS COMPLETED INSIDE
WIRING FROM THE DWDM EQUIPMENT SUITE TO THE
GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH
LOCATION, THEY MUST ENSURE THE LIGHT LEVEL READINGS
(DB LOSS) ARE ADJUSTED TO READ -5 TO -13 LOSS.
ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE
NOTICE OF COMPLETION (NOC) SENT TO DITCO.
***THE VENDOR MUST TERMINATE 2.5GB WAVE SERVICE AT
BOTH LOCATIONS IAW UNIQUE INSTALLATION FACTORS.***
7. THE 2.5GB WAVE SERVICE MUST PASS A DOCUMENTED
SATISFACTORY 72 HOUR END TO END TEST IAW ITU
STANDARD M.2101 PRIOR TO TURN UP TO THE GOVERNMENT.
8. CROSS REFERENCE CCSD IS "DIYU6KC3".
REMARKS:
1. VENDOR MUST MEET SVC DATE.
2. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: SINGLE-MODE
INTERFACE REQUIREMENT/INTERFACE DATA RATE:
LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR,
2.5 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991
(R2003). ALL OPTIONS DEFINED SC CONNECTOR,
SINGLE-MODE FIBER PER ANSI T1.105.06-2002
(SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).
(B) LINE MUST REMAIN FULLY OPERATIONAL AND
AVAILABLE
TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT
LEAST 99.5% OR BETTER.
(C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR
TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.
(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO
BE ENGINEERED INTO CIRCUIT.
(E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS
(F) NO NETWORK INTERFACE UNIT.
(G) DEDICATED PATH.
(H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO
ASSIST IN ANY CIRCUIT OUTAGES.
(I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY
END TO END TEST ON THE 2.5 WAVE SERVICE IAW ITU
STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST
SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST
RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE
ACCEPTING AUTHORITY FOR REVIEW.
(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL
CENTER OF THIS 2.5GB WAVE SERVICE.
(K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON
BEHALF OF THE GOVERNMENT BY THE CONUS GNOSC:
PRI POC: CONTACT: MIKE REEVES
(C) 618-220-8973 (D) 770-8973
ALT POC: CONTACT: DAMION SCANDRICK
(C) 618-220-9634 (D) 770-9634
ALT POC: CONTACT: AARON SMITH
(C) 618-220-9820 (D) 770-9820
ALT POC: CONTACT: BOB RISKY
(C) 618-220-8632 (D) 770-8632
ALT POC: ORGANIZATIONAL NUMBER
(C) 618-220-8691 (D) 770-8691
(L) THE VENDOR MUST PROVIDE: 1) THE LONG HAUL CIRCUIT
NUMBER AND THE 1-800 TROUBLE REPORT NUMBER TO THE
ACCEPTING AUTHORITY PRIOR TO THE GOVERNMENT
ACCEPTING SERVICE. INSIDE WIRING MUST BE
COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR
TO TURNUP TO THE GOVERNMENT.
3. VENDOR IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF 2.5GB WAVE SERVICE IAW UNIQUE
INSTALLATION FACTORS.
4. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE
INSTALLATION FACTORS.
5. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS
IN ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT
BOTH USER LOCATIONS. IF UNABLE TO REACH SITE POC'S
CONTACT KEN DIEF OR RAY BURKE FOR ASSISTANCE AT:
(301) 225-2416/2550.
6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT
AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED
TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE DISN
CUSTOMER CONTACT CENTER (DCCC) SCOTT AFB, IL.
TOLL FREE: 1-855-868-9500
COML: 618-220-9500 DSN: 312-770-9500
7. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW
DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL.
GUIDANCE ON SUBMISSION IS AVAILABLE AT
<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>.
CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE
COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS:
LINE RATE: 2.5GB.
LINE CODE: NRZ
FRAME FORMAT: SCRAMBLED IAW
ANSI T1.104-1991 (R2003)
1. TEST AND ACCEPTANCE: FIBER OPTIC 2.5GB WAVE CIRCUITS
SHALL PASS A FULLY DOCUMENTED SATISFACTORY SOAK
TEST BY THE CONUS GNOSC AT SCOTT AFB, IL.
PRIMARY: (C) 618-220-8691 (D) 770-8691
2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED
SHALL MEET THE FOLLOWING PERFORMANCE REQUIREMENTS
ON A MONTHLY BASIS.
PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION:
NON-DIVERSE/NON-PROTECTED
AVAILABILITY: GREATER THAN OR EQUAL TO 99.5% OR BETTER.
MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC):
LESS THAN OR EQUAL TO 9
% ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005
% SEVERELY ERRORED SECONDS (SES): LESS THAN OR
EQUAL TO 0.00035
BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN
OR EQUAL TO 5 X 10-6
BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP):
LESS THAN OR EQUAL TO 1 PER 72 HOURS
JITTER SEE NOTE 1 (JITTER)
BER: LESS THAN OR EQUAL TO 1X10-12
DELAY (ONE WAY): * LESSER OF 10 MSEC OR
(0.01 X D MSEC) * WHERE "D" IS THE SDP TO SDP
TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT
CIRCLE, IN KILOMETERS.
3. ROUND TRIP DELAY (RTD) SHALL BE LESS THAN OR EQUAL
TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE
GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING
AUTHORITY WILL CONFIRM THE RTD DURING THE TURN-UP
AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE
CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO
IMMEDIATELY IN WRITING.
(**UNIQ INSTALL FACTORS**) (SP A) -1B. ADDITIONALLY, VENDOR
MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE
EXACT TERMINATION POINT WHEN SERVICE IS COMPLETED.
(** DIVERSITY INFO **)
SERVICE DIVERSITY REQUESTED; DUAL HOMING CCSD: 6NG3;
(** ADDITIONAL PROVISIONING INFORMATION **) (ORG ACCT) DISN
FIBER OPTIC BACKBONE & O/W CONTROL
IMPLEMENTATION ASSISTANCE: FOR DISN CORE / DEDICATED / NIPRNET /
SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE IMPLEMENTA
TION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF ACTIVATIONS
TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL
.MIL, OR CALL DSN 770-8627; COML 618-220-8627.
IMPLEMENTATION ASSISTANCE CONTINUED: FOR CIRCUIT INSTALLATION
ASSISTANCE WITH THE COMMERCIAL LEASED PATH, CONTACT
DCP COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,
C614-692-0820