ATTACHMENT 1 FOR SOLICITATION HC101318QA434
FIBER TERMINATION: SINGLE-MODE INTERFACE REQUIREMENT/INTERFACE
DATA RATE: LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR, 10GBPS,
NRZ, SCRAMBLED PER ANSI T1.104-1991 (R2003). ALL OPTIONS DEFINED SC
CONNECTOR, SINGLE-MODE FIBER PER ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2,
LR-1, LR-2, LR-3). (B) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE
TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR ONCE
TROUBLE-CALL HAS BEEN REPORTED. GFE CLOCKING: VENDOR ESFU (OR
EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT.
SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS. NO NETWORK
INTERFACE UNIT. (G) DEDICATED PATH. (H) CARRIER REQUIRED TO HAVE
CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES. THE VENDOR MUST
CONDUCT A 72 HOUR SATISFACTORY END TO END TEST ON THE 10GB WAVE
SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST
SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST RESULTS AND THOSE
RESULTS MUST BE EMAILED TO THE ACCEPTING AUTHORITY FOR REVIEW.
VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER. VENDOR IS
RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER
IAW UNIQUE INSTALLATION FACTORS. INSIDE WIRING IS AUTHORIZED IAW
WITH THE UNIQUE INSTALLATION FACTORS.
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS: LINE RATE: 10GB. LINE CODE: NRZ. FRAME
FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003). 1. TEST AND ACCEPTANCE:
FIBER OPTIC 10GB WAVE CIRCUITS SHALL PASS A FULLY DOCUMENTED
SATISFACTORY SOAK TEST BY THE CONUS GNOSC AT SCOTT AFB, IL. PRIMARY:
(C) 618-220-8691 (D) 770-8691.
2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL MEET THE
FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS.
PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-
DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO 99.5%
OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC): LESS THAN
OR EQUAL TO 9%. ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005%.
SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035.
BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5 X 10-6.
BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO
1 PER 72 HOURS. JITTER SEE NOTE 1 (JITTER). BER: LESS THAN OR EQUAL TO
1X10-12. DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE
"D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT
CIRCLE, IN KILOMETERS. 3. ROUND TRIP DELAY (RTD) FOR THIS DISA
TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM THE
CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMER'S
SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR
EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S
MISSION.