GCHS Combined Acoustic - Drawings (1).pdf
PDF 9 MB Posted
- Attached to
- Greeley Central High School Acoustic Upgrades State and local contract opportunity
- Solicitation number
- WCSD6-24-380-0423
- Issued by
- Weld County, Colorado
About this file
The document is a set of architectural construction drawings for the Weld County School District #6 Greeley Central High School Acoustic Improvements project located in Greeley, Colorado. The drawings, prepared by GSGarchitecture Design in March 2024, detail acoustic upgrades for multiple spaces including the auditorium (Room 160), gymnasium (Room 180), band room (Room 161), ensemble room (Room 163), historic library (Room 215), and dance studio (Room 282A). The project involves installing various acoustic treatment materials such as tuned absorber/diffuser panels, wave baffles, and hardside acoustical wrapped panels in specific colors and configurations, with careful attention to placement, mounting, and coordination with existing building elements.
The drawings provide comprehensive technical specifications for acoustic improvements, including detailed placement instructions for panels in black, eggshell, silver gray, and custom orange colors. The project appears to be focused on improving sound quality and acoustic performance across different school spaces, with specific requirements for panel sizes, mounting methods (using Z-clips), and careful consideration of existing infrastructure like sprinkler heads, lighting fixtures, and building structures. The drawings include multiple plan views, reflected ceiling plans, elevation views, and keynotes providing specific installation guidance for contractors, emphasizing precise measurements, color specifications, and the need to coordinate with existing building systems.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| GCHS Combined Acoustic - Project Manual.pdf | ||
| GCHS Acoustical Upgrade_front.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATERIAL SYMBOLS
EARTH/GRADE
POROUS STRUCTURAL FILL
(STONE, GRAVEL, ETC)
ASPHALT PAVING
CAST STONE
CONCRETE MASONRY (CMU) UNIT
WOOD (ROUGH FRAMING)
GLASS MASONRY UNIT
METAL
CONCRETE
PRECAST CONCRETE
WOOD (FINISHED)
WOOD (ROUGH CONTINUOUS MEMBERS)
WOOD SHIM BLOCKING (INTERRUPTED MEMBER)
PLYWOOD
PARTICLE BOARD
INSULATION (LOOSE OR BATT)
INSULATION (RIGID)
PLASTER, SAND GROUT, MORTAR
GYPSUM WALLBOARD
TILE (CERAMIC, CLAY)
ACOUSTICAL TILE
RELILIENT TILE
GLASS
GYPSUM SHEATHING
A101
SIM
DOOR REFERENCE MARK
NORTH ARROW
CENTER LINE REFERENCE
ROOM NAME AND NUMBER REFERENCE
COLUMN GRID REFERENCE
BUILDING SECTION REFERENCE
LEVEL REFERENCE
CALLOUT REFERENCE
SPOT ELEVATION REFERENCE
TOILET ROOM ACCESSORIES
BREAK LINE
GRAPHIC SYMBOLS
A101
A101
PLAN LEVEL
100'-0"
ROOM NAME AND NUMBER REFERENCE
WALL SECTION REFERENCE
SPOT ELEVATION REFERENCE
VIEW REFERENCE WITH DRAWING SCALE
1i WALL TYPE REFERENCE
WINDOW REFERENCE
KEY NOTE DESIGNATIONA
PROPERTY, BOUNDARY, AND
MATCH LINES
LINE ABOVE OR HIDDEN LINE
1 REVISION DESIGNATION
(CLOUD ENCLOSES AREA
OF REVISION)
9.2A
B
C
D
INTERIOR ELEVATION
REFERENCE AS
NUMBERED ON SHEET 9.2
A101
1 View Name 1/8" 1'-0"A101
JOB #
CASPER, WY - GREELEY, CO - SHERIDAN, WY
GREELEY CENTRAL HS ACOUSTIC IMPROVEMENTS
WELD COUNTY SCHOOL DISTRICT #6
G R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
IM
PR
O
VE
M
EN
TS
/0 8/
CONSTRUCTION DOCUMENTS
ARCHITECT: ACOUSTICAL:
GEILER & ASSOCIATES, LLC
12355 EAST CORNELL AVE.
AURORA, CO 80014
PHONE: 303-766-7100
EMAIL:
RSHANNON@GEILERACOUSTICS.COM
CONTACT NAME: RILEY SHANNON
MARCH 08, 2024
OWNERS INFO:
GREELEY CENTRAL HIGH SCHOOL VICINITY MAP
1515 14TH AVENUE
GREELEY, CO 80631
(N.T.S.)
DRAWING INDEX
Sheet Number Sheet Name
G0.10 CODE PLAN - LEVEL 1
G0.11 CODE PLAN - LEVEL 2
A1.01 REFERENCE FLOOR PLAN - EXISTING LEVEL 1
A1.02 REFERENCE FLOOR PLAN - EXISTING LEVEL 2
A2.10 AUDITORIUM 160 DEMOLITION PLANS
A2.50 BAND ROOM 161 DEMOLITION PLANS
A2.60 ENSEMBLE ROOM 163 DEMOLITION PLANS
A3.20 GYMNASIUM 180 REFLECTED CEILING PLAN AND INTERIOR ELEVATIONS
A3.30 HISTORIC LIBRARY 215 FLOOR AND REFLECTED CEILING PLANS
A3.40 DANCE STUDIO 282A FLOOR AND REFLECTED CEILING PLAN
A3.50 BAND ROOM 161 FLOOR AND REFLECTED CEILING PLANS
A3.60 ENSEMBLE ROOM 163 FLOOR AND REFLECTED CEILING PLANS
A5.20 GYMNASIUM 180 INTERIOR ELEVATIONS
A5.21 GYMNASIUM 180 INTERIOR ELEVATIONS
GSG ARCHITECTURE
3535 12TH ST, SUITE C
GREELEY, CO 80634
PHONE: 970-888-3273
EMAIL: CKLOSTERMAN@
GSGARCHITECTURE.COM
PROJECT MANAGER: CRYSTAL
KLOSTERMAN
PRINCIPAL ARCHITECT: JAMES
HOLLOWAY
WELD COUNTY SCHOOL DISTRICT #6
2204 5TH AVENUE
GREELEY, CO 80631
PHONE: 970-348-6441
EMAIL: MHOLZMEISTER@
GREELEYSCHOOLS.ORG
CONTACT NAME: MATT HOLZMEISTER
D W
CODE DATA:
APPLICABLE PROJECTS & LOCATIONS:
SECURITY AND CAPITAL IMPROVEMENTS: COLLEGE & CAREER READINESS
INTERIOR RENOVATIONS, DOOR HARDWARE & SECURITY UPGRADES, &
EDUCATIONAL SPACE FINISH UPGRADES FOR:
- GREELEY CENTRAL HIGH SCHOOL; GREELEY, CO.
APPLICABLE CODES:
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL BUILDING CODE
2021 IEBC (INTERNATIONAL EXISTING BUILDING CODE):
LEVEL 1 ALTERATION INCLUDES THE REMOVAL AND REPLACEMENT OR THE COVERING OF
EXISTING MATERIALS , ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS,
ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME PURPOSE.
APPLICATION: LEVEL 1 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF THE IEBC
CHAPTER 7.
SECTION 702.1-702.3: NEWLY INSTALLED INTERIOR WALL & CEILING FINISHES, NEW INTERIOR
FLOOR FINISHES, AND NEWLY INSTALLED INTERIOR TRIM MATERIALS SHALL COMPLY WITH
CHAPTER 8 OF THE IBC.
SECTION 702.6: ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND METHODS
REQUIREMENTS IN THE INTERNATIONAL BUILDING CODE, INTERNATIONAL ENERGY
CONSERVATION CODE, INTERNATIONAL MECHANICAL CODE, AND INTERNATIONAL PLUMBING
CODE.
SECTION 703.1: FIRE PROTECTION: ALTERATIONS SHALL BE DONE IN A MANNER THAT
MAINTAINS THE LEVEL OF PROTECTION PROVIDED.
SECTION 704.1: ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF
PROTECTION PROVIDED FOR THE MEANS OF EGRESS.
SECTION 705.1: A FACILITY THAT IS ALTERED SHALL COMPLY WITH THE APPLICABLE
PROVISIONS IN SECTIONS 705.1.1 THROUGH 705.1.14, AND CHAPTER 11 OF THE IBC UNLESS IT
IS TECHNICALLY INFEASIBLE.
LEVEL 2 ALTERATION INCLUDES THE RECONFIGURATION OF SPACE, THE ADDITION OR
ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY
SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
APPLICATION: LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF THE IEBC
CHAPTER 7 (LEVEL 1) AS WELL AS THE PROVISIONS OF CHAPTER 8 (LEVEL 2).
(FOR GREELEY CENTRAL HIGH SCHOOL )
EXISTING BUILDING CODE INFO:
CONSTRUCTION TYPE: ASSUME TYPE II-B FOR ORIGINAL BUILDING AND III-B FOR ADDTIONS
(SEPARATED INTO 7 DISTINCT BUILDING AREAS BY 2 HR. WALLS)
EXISTING EXTERIOR WALL CONSTRUCTION:
- TYP. SOLID MASONRY OR MASONRY VENEER; NONCOMBUSTIBLE
EXISTING INTERIOR WALL CONSTRUCTION:
- CMU BLOCK WALLS - VARIOUS WIDTHS
- METAL & WOOD STUDS W/ GYP BD OR PLASTER ON EACH SIDE TYP. -
VARIOUS WIDTHS
ROOF STRUCTURE: VARIES: WOOD FRAMING, STEEL BAR JOISTS & REINFORCED
CONCRETE SLABS
EXISTING BUILDING IS A MIX OF SINGLE STORY WITH AREAS OF TWO AND THREE STORIES
ABOVE GRADE. THE OLDEST PORTION OF THE BUILDING HAS A BASEMENT PRIMARILY USED
FOR MECHANICAL AND STORAGE (NOT HABITABLE).
EXISTING BUILDING EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT.
OCCUPANCY GROUP E (EDUCATION)
EXISTING BUILDING AREAS (SF):
BUILDING AREA 1 29,600 SF (3 STORIES) BUILDING AREA 2 10,000 SF (2 STORIES)
BUILDING AREA 3 21,500 SF (2 STORIES) BUILDING AREA 4 18,000 SF (2 STORIES)
BUILDING AREA 5 11,000 SF (1 STORY) BUILDING AREA 6 37,000 SF (2 STORIES)
BUILDING AREA 7 26,500 SF (1 STORY EXTERIOR)
*ALLOWABLE BUILDING AREA SF (PER TABLE 506.2) GROUP E TYPE II-B (SM) 43,500 SF / FLR.
*ALLOWABLE BUILDING AREA SF (PER TABLE 506.2) GROUP E TYPE III-B (S1) 58,000 SF
*ALLOWABLE BUILDING AREA SF (PER TABLE 506.2) GROUP E TYPE III-B (SM) 43,500 SF / FLR.
CODE ANALYSIS LEGEND
EXIT ACCESS
EXIT DISCHARGE
1-HR FIRE RATED WALL
EXIT ACCESS TRAVEL DISTANCE
COMMON PATH OF EGRESS TRAVEL
1 HR. RATED CORRIDOR SEPARATION AREA
2-HR FIRE RATED WALL
CODE KEY PLAN (IEBC)
BLDG 1
NOTE: BUILDING SEPERATED
INTO SEVEN BUILDING AREAS
BY 2 HR. WALLS
BLDG 7
EXIT COURTYARD
BLDG 2
BLDG 3
BLDG 4
BLDG 5
BLDG 6
WORK SCOPE LEGEND
AREAS OF WORK
AREAS WITH NO WORK
30015 SF
FIRE AREA I
8123 SF
FIRE AREA II
19404 SF
FIRE AREA III
17663 SF
FIRE AREA IV
26149 SF
EXIT COURTYARD
FIRE AREA VII
10679 SF
FIRE AREA V
36482 SF
FIRE AREA VI
FIRE AREA - IV
OCCUPANT LOAD - 1396
EGRESS REQUIRED - 210"
EGRESS PROVIDED - 396"
FIRE AREA - V
OCCUPANT LOAD - 372
EGRESS REQUIRED - 55.8"
EGRESS PROVIDED - 256"
FIRE AREA - VI
OCCUPANT LOAD - 1674
EGRESS REQUIRED - 252"
EGRESS PROVIDED - 576"
FIRE AREA - I
OCCUPANT LOAD - 505 (LEVEL 1)
EGRESS REQUIRED - 75.75"
EGRESS PROVIDED - 324"
FIRE AREA - III
OCCUPANT LOAD - 2,487
EGRESS REQUIRED - 373.05"
EGRESS PROVIDED - 432" *
INCLUDES EGRESS THROUGH
LOBBY 185 (EXTERIOR DOORS
INCLUDED ONLY)
FIRE AREA - II
OCCUPANT LOAD - 213
EGRESS REQUIRED - 31.95"
EGRESS PROVIDED - 432" *
* EGRESS COMPONENTS ALSO
SERVE FIRE AREA III
LOADING
191C
STOR.
191CA
COOLER
191F
STOR.
E102D
KITCHEN
OFFICE
191A
TOILET
E102C
STOR.
191B
CAFETERIA
CUST. (UNDER)
185F MENS
185D
WOMENS
185E
VEST.
F105
HALL
STOR.
186B
TEACHERS LOUNGE
186A
LOBBY
STOR.
185C
TICKET SALES
185B
STOR.
185BA
STOR.
185A
10479 SF
GYMNASIUM
STOR.
F114E
HC DRESSING
181A
CORRIDOR
F109
STORAGE
182D
CORRIDOR
11A
COMMONS
VB STOR.
184F VEST.
F107A
BOY'S ATHL. 1
COACH
184E
TOILET
184D
SHOWER
184C
COACH
184A
SHOWER
182C
TOILET
182B
ENTRY
182A
BOY'S ATHL.
ELECT.
182AB
HALL
830 SF
GIRL'S P.E.
CUST.
181B
SHOWER
181C
SHOWER
183C
TOILET
F113B
CUST.
183B
914 SF
BOY'S P.E.
STOR.
183A
HALL
WRESTLING/MP GYM
AUX GYM
COACH'S TRAINING
172AC
TRAINING
172A
TRAINING OFFICE
172AB
ATHLETIC STORAGE
H104B
ATHLETIC STORAGE
172B
HALL
VEST.
71A
GREAT HALL
J105
BAND ROOM
STOR.
161A PRACTICE
161B
ENSEMBLE
MUSIC TECH
MENS
70B
WOMENS
70C
GREAT HALL NORTH
CORRIDOR
HALL
CORRIDOR
OFFICE
101A
SPECIAL EDUCATION
OFFICE
101B
HOME ECONOMICS
LAUNDRY
B102A
OFFICE
B102B
CLINIC
103A
STOR.
103B
HC TOILET
B104
LANGUAGE
STOR.
B105A
SEWING ROOM
FOREIGN LANG.
STOR.
B102E
MEN'S RR
STOR.
10CA
FOREIGN LANG.
JOURNALISM
SE
M
IN
A R C
LA
SS
SE
M
IN
A R C
LA
SS
DARK ROOM
B155B
PHOTOGRAPHY
STOR./MECH.
STOR.
120B
ELECTRICAL
ELECTRICAL
STOR.
120C
ELEV. MACH.
120D
WOMEN'S RR
10F
STOR.
10C
ATTEND.
OFFICE
PRINCIPAL
BOOKEEPER
121B
VAULT
121C
ADMIN
B123E
ADMIN
ADMIN
WORK ROOM
ADMIN SEC.
B125
CLINIC
TOILET
145A
CLINIC
OFFICE
OFFICE
STOR.
121A
ASSIST. PRINCIPAL
OFFICE
ASSIST. PRINCIPAL
OFFICE
KILN
126A
2D ART
OFFICE
128A
3D ART
ART STOR.
126B
ART DISPLAY
126C
STAFF TOILET
10A
ART
AIRBRUSH
127A
OFFICE
127B
SPECIAL EDUCATION
RESOURCES
COUNSELING
C O R R
ID
O R
CORRIDOR
14A
VEST.
10BVEST.
B142A
VEST.
B147A
STOR.
B114A
STOR.
B117A
STOR.
10E
ELECT.
B106
STAIR
B143A
THEATER LOBBY
PRACTICE
163A
PRACTICE
161C
MUSIC OFF.
161D
MUSIC VEST.
J106A
MUSIC CORRIDOR
PIT
160F
VEST.
J145
VEST.
J144
STOR.
J142
SC
IE
N C E C O R R
ID
O R
MECH.
54A
CHEM. STOR.
150AA
CUSTODIAL
J133
CHEMISTRY
PHYSICS LAB
A/V STOR.
51B
PHYSICS STOR.
150A
SCIENCE OFFICE
150AC
SCIENCE PREP
150AB
T.V. STUDIO
53AB
T.V. EDIT
53A
BIOLOGY
152BIOLOGY
BIOLOGY
SET ROOM
HALL
MEN'S DRESSING
160C
TOILET
160D
MAKEUP
160B
WOMEN'S DRESSING
160AA
TOILET
160AB
MECH.
55A
ELECT.
55B
STOR.
157C
STOR.
157B
STOR.
157A
HEALTH SCIENCE
TECHNOLOGY
STOR.
157E
FAB ROOM
157D
MECH.
52A
WOMEN
52B
MEN
52C
TECH LAB
DISPLAY
155D
DATA
155C STUDY ROOM
155E
WET AREA
155F
CLASSROOM
155A
STOR.
155B
SCIENCE AND
TECHNOLOGY
SCIENCE AND
TECHNOLOGY
ELECT.
51AB
MECH.
CUST.
51A
STAGE
160A
AUDITORIUM
SCIENCE CORRIDOR
SC
IE
N C E A N D T
EC
H
C O R R
ID
O R
WOMEN
54B
MEN
54C
SET CORRIDOR
STOR.
120A
HALL
HALL
F104
DRESSING ROOM
F113D
DRESSING ROOM
F114A
BOY'S ATHLETICS
184B
STAIR
B155CHALL
HALL
ENTRY
VESTIBULE
70D
OFFICE
113A
OFFICE
113B
STAIR
B144
STAIR
B142
188 SF
NORTH SECURE ENTRY
N101
48 SF
WORK / STOR.
N102
COMBINED OCCUPANT LOAD
OF FIRE AREA II AND III 2,718
2,718 / 2 1,359
1,359 X 0.15 203.85" REQUIRED
@ THIS EXIT
252" PROVIDED
x
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:0
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
CODE PLAN - LEVEL 1
G0.10
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
CODE PLAN - LEVEL 1
No. Revision Description Date
CODE DATA:
APPLICABLE PROJECTS & LOCATIONS:
SECURITY AND CAPITAL IMPROVEMENTS: COLLEGE & CAREER READINESS
INTERIOR RENOVATIONS, DOOR HARDWARE & SECURITY UPGRADES, &
EDUCATIONAL SPACE FINISH UPGRADES FOR:
- GREELEY CENTRAL HIGH SCHOOL; GREELEY, CO.
APPLICABLE CODES:
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL BUILDING CODE
2021 IEBC (INTERNATIONAL EXISTING BUILDING CODE):
LEVEL 1 ALTERATION INCLUDES THE REMOVAL AND REPLACEMENT OR THE COVERING OF
EXISTING MATERIALS , ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS,
ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME PURPOSE.
APPLICATION: LEVEL 1 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF THE IEBC
CHAPTER 7.
SECTION 702.1-702.3: NEWLY INSTALLED INTERIOR WALL & CEILING FINISHES, NEW INTERIOR
FLOOR FINISHES, AND NEWLY INSTALLED INTERIOR TRIM MATERIALS SHALL COMPLY WITH
CHAPTER 8 OF THE IBC.
SECTION 702.6: ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND METHODS
REQUIREMENTS IN THE INTERNATIONAL BUILDING CODE, INTERNATIONAL ENERGY
CONSERVATION CODE, INTERNATIONAL MECHANICAL CODE, AND INTERNATIONAL PLUMBING
CODE.
SECTION 703.1: FIRE PROTECTION: ALTERATIONS SHALL BE DONE IN A MANNER THAT
MAINTAINS THE LEVEL OF PROTECTION PROVIDED.
SECTION 704.1: ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF
PROTECTION PROVIDED FOR THE MEANS OF EGRESS.
SECTION 705.1: A FACILITY THAT IS ALTERED SHALL COMPLY WITH THE APPLICABLE
PROVISIONS IN SECTIONS 705.1.1 THROUGH 705.1.14, AND CHAPTER 11 OF THE IBC UNLESS IT
IS TECHNICALLY INFEASIBLE.
LEVEL 2 ALTERATION INCLUDES THE RECONFIGURATION OF SPACE, THE ADDITION OR
ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY
SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
APPLICATION: LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF THE IEBC
CHAPTER 7 (LEVEL 1) AS WELL AS THE PROVISIONS OF CHAPTER 8 (LEVEL 2).
(FOR GREELEY CENTRAL HIGH SCHOOL )
EXISTING BUILDING CODE INFO:
CONSTRUCTION TYPE: ASSUME TYPE II-B FOR ORIGINAL BUILDING AND III-B FOR ADDTIONS
(SEPARATED INTO 7 DISTINCT BUILDING AREAS BY 2 HR. WALLS)
EXISTING EXTERIOR WALL CONSTRUCTION:
- TYP. SOLID MASONRY OR MASONRY VENEER; NONCOMBUSTIBLE
EXISTING INTERIOR WALL CONSTRUCTION:
- CMU BLOCK WALLS - VARIOUS WIDTHS
- METAL & WOOD STUDS W/ GYP BD OR PLASTER ON EACH SIDE TYP. -
VARIOUS WIDTHS
ROOF STRUCTURE: VARIES: WOOD FRAMING, STEEL BAR JOISTS & REINFORCED
CONCRETE SLABS
EXISTING BUILDING IS A MIX OF SINGLE STORY WITH AREAS OF TWO AND THREE STORIES
ABOVE GRADE. THE OLDEST PORTION OF THE BUILDING HAS A BASEMENT PRIMARILY USED
FOR MECHANICAL AND STORAGE (NOT HABITABLE).
EXISTING BUILDING EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT.
OCCUPANCY GROUP E (EDUCATION)
EXISTING BUILDING AREAS (SF):
BUILDING AREA 1 29,600 SF (3 STORIES) BUILDING AREA 2 10,000 SF (2 STORIES)
BUILDING AREA 3 21,500 SF (2 STORIES) BUILDING AREA 4 18,000 SF (2 STORIES)
BUILDING AREA 5 11,000 SF (1 STORY) BUILDING AREA 6 37,000 SF (2 STORIES)
BUILDING AREA 7 26,500 SF (1 STORY EXTERIOR)
*ALLOWABLE BUILDING AREA SF (PER TABLE 506.2) GROUP E TYPE II-B (SM) 43,500 SF / FLR.
*ALLOWABLE BUILDING AREA SF (PER TABLE 506.2) GROUP E TYPE III-B (S1) 58,000 SF
*ALLOWABLE BUILDING AREA SF (PER TABLE 506.2) GROUP E TYPE III-B (SM) 43,500 SF / FLR.
CODE ANALYSIS LEGEND
EXIT ACCESS
EXIT DISCHARGE
1-HR FIRE RATED WALL
EXIT ACCESS TRAVEL DISTANCE
COMMON PATH OF EGRESS TRAVEL
1 HR. RATED CORRIDOR SEPARATION AREA
2-HR FIRE RATED WALL
CODE KEY PLAN (IEBC)
BLDG 1
NOTE: BUILDING SEPERATED
INTO SEVEN BUILDING AREAS
BY 2 HR. WALLS
BLDG 7
EXIT COURTYARD
BLDG 2
BLDG 3
BLDG 4
BLDG 5
BLDG 6
WORK SCOPE LEGEND
AREAS OF WORK
AREAS WITH NO WORK
FIRE AREA I
LIBRARY/ MEDIA
CENTER
CORRIDOR
HISTORIC
DESIGNATION
LIBRARY/COMPUTER
ROOM
SCHOOL STORE
215A
MATH OFFICE
BUSINESS
COMPUTER LAB
BUSINESS
STAIR
C244
BUS. OFFICE
TECH SPECIALIST
MATH
CORRIDOR
BUSINESS
HALL
WOMEN'S RR
MEN'S RR
LOUNGE
OFFICE
MATH
207B
MATH
207A
FOREIGN LANG.
MATH
MATH
MATH
MATH
CORRIDOR
21A
CORRIDOR
HALL
STAIR
C242
GENERAL USE MULTI
PURPOSE
BALCONY
WEIGHT ROOM
STOR.
282D
BRIDGE
HALL
P.E. OFFICE
COACH'S OFF.
CLASSROOM
STOR.
285B
MECH.
281B
HALL
MECH.
282B
FAN ROOM
GIRL'S LOCKER ROOM
WOMEN'S RR
SHOWER
OFFICE
COACH'S LOCKER
ROOM
HALL
STOR.
281A
UPPER STORAGE
DATA ROOM
DIMMER ROOM
SPOT
261A VEST.
261B CONTROL
SOUND
261C
SPOT
261D
VEST.
205A
STAFF
205B
JAN.
210A
JAN.
218A
HC TOILET
A/V STOR.
216E
CONFERENCE
216F
WORK
216D
OFFICE
216A VIDEO STUDY
216B
ELEV. MACH.
DANCE
282A
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:0
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
CODE PLAN - LEVEL 2
G0.11
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
CODE PLAN - LEVEL 2
1C
119A
115B
5C
131A 135A
121A
145A
B1
10E
12712 6C
6B
127B 127A
127A1
120C 120D
120B
120E
B1
8B
128D
8A
8C
B1 A
5A
A
B104 B106
3A 10
3B
B103
1A 101B
102A
B1 A
B1 B
102B
2C
B105A
111B
4A
B102E
6 10CA
B155C
C
F
1A
B142A B142B
11B
A
B
B1 A1
B1 A2
10B2 10B1
14A
A
161A
1A
1A
1B
1D
3A
1D
1C
160D
160C
J142
J1
150AA
8A
6A
4A
156B
160E
4B 15
157A
55B1
0A
B 0C
157A1
157A2
157B
157C
B
52B
C
155B
52A
157D
51AB
151A
51B
150A2
150AC
150AB
0A
0A
8B
2A
AC
J105
0B
J1
J1
0A
160AA
A
J1 A
C
A
0B
0A
0A
B1
0D
162A
51A
AB
153A
2B 53 A
54A
160AC
A
163A
157E
0A
185A1
1A
1181A
181B
5B
185C1 18 5F 2 18
5D
5E
186B
6A
6C
2A F1
A
184A
2B
3A
183A
183B
190A
1D
191B
191A
E102D 191C3
191C
1C
2D
70AA
170A
2A
C
172AC3
2A
2A
B1H 4B
72A
2B
2A
2A
B2
2A
2B
126A
155D
5C
155E
155A
AB
170B
0C
0D
A
172AC2
E1 C
F1 A
184E
157D1
C O
VE
R
ED
SI
D
EW
AL
K
ELEV.
UP
UP
UP
UP
DN
DN
DN
DN
R
AM
P
R
AM
P
RAMP
UP
DN
UP UP
UP
UP UP
UP
UP
DN
DN
RAMP
DN RAMP
DN
DN
DN
DN
UP
UP
126A
DN
UP
UP
UP
UP
UP
RAMP
UP
RAMP DN
RAMP
DN
VAT FLOORING
VAT
UP
DN
RAMP
VAT
FLOORING
D.C.
182AB
0G
0B
0C
4F
H113C
113B
113A 123A
0A
F1 B
C
B
5F
191C4
B150B149
10G
B155
1B
UTILITY
COURT
50B
159A
159B
80A
80B
80C
ELEV.
A3.20
A3.10
A3.50
A3.60
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:0
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
REFERENCE FLOOR
PLAN - EXISTING
LEVEL 1
A1.01
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/16" 1'-0"
REFERENCE FLOOR PLAN - EXISTING LEVEL 1
7A
7B
205B
7B
205A
6F
6F
216E
216D
216D1
216B
6A
227A
6B
226A
5A21
1A
5A
281A
281B
2D
2C
2A
2B
270 75A
274A
218B
274B
75B
216C
8A
211A
207B1207A1
0210A
DN
DN
UP
UP
DN
DN
DN
DN
DN
DN
DN
CPT ASSUMED
DN
UP
UP
RISERS
ELEV.
285A
285B
DN
UP
DN
G
0A
0B
261A
261B
A
RISERS
OPEN TO
BELOW
120E
B126
128D
102C
B142A
11B
B147A1 B147A2
10B1
161A
160AB
J106A
181A
186C
183A
190A
191C3
172B1 172A1
72A
172B172A
71A
70AB
F107A
170D170C
B147
B155
159A
215B
A3.40
A3.30
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:1
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
REFERENCE FLOOR
PLAN - EXISTING
LEVEL 2
A1.02
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/16" 1'-0"A1.02
1 REFERENCE FLOOR PLAN - EXISTING LEVEL 2
A2.10
A2.10
TAKE CARE WHEN REMOVING PANELS.
SALVAGE AND RETURN TO OWNER EXISTING
ACOUSTICAL WALL PANELS.
ARCHITECT HAS FIELD VERIFIED CRITICAL DIMENSIONS AND USED OWNER'S ORIGINAL DOCUMENT TO GENERATE THESE DRAWINGS. CONTACT THE ARCHITECT IMMEDIATELY IF SUBSTANTIAL DIFFERENCES
BETWEEN DIMENSIONS INDICATED DIFFER FROM THOSE ENCOUNTERED.
DASHED LINES INDICATE BUILDING MATERIALS TO BE REMOVED IN THEIR ENTIRETY, U.N.O. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DEMOLITION PLANS FOR SPECIFIC TRADE WORK TO BE DONE IN
THESE AREAS.
ALL DEMOLITION DEBRIS TO BE DISPOSED OF OFF SITE IN LEGAL WASTE FACILITY BY THE GENERAL
CONTRACTOR. UTILIZE COVERED TRANSPORTATION CARTS THROUGH THE BUILDING.
EXERCISE CAUTION NOT TO DAMAGE EXISTING FINISHES & UNDER-LYING SURFACES DURING DEMOLITION
WORK CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE.
PRIOR TO ALL DEMOLITION WORK, REFER TO HAZARDOUS MATERIAL INSPECTION REPORT AND ABATE ALL
IDENTIFIED MATERIAL AS REQUIRED.
CONSULT WITH OWNER AND DEVELOP A SAFETY AND EVACUATION PLAN WHICH MAINTAINS CRITICAL
EGRESS PATHS.
REFER TO FLOOR PLANS AND ELEVATIONS FOR LOCATIONS AND DIMENSIONS OF OPENINGS IN EXISTING
WALLS.
NOTIFY ARCHITECT IMMEDIATELY UPON DETECTING DISCREPANCIES BETWEEN DRAWINGS & EXISTING
FIELD CONDITIONS.
THE CONTRACTOR SHALL SCHEDULE, COORDINATE AND CONDUCT A PRE-DEMOLITION CONFERENCE FOR
THE PROJECT PRIOR TO STARTING THE WORK.
REMOVE AND SALVAGE IDENTIFIED ITEMS, EXISTING EQUIPMENT, SIGNAGE AND FURNISHINGS FROM THE EXISTING STRUCTURES AS REQUIRED. COORDINATE ALL ITEMS TO BE SALVAGED WITH THE OWNER.
REFER TO THE MECHANICAL & ELECTRICAL DRAWINGS FOR RELATED MECHANICAL AND ELECTRICAL
DEMOLITION WORK.
REMOVE ALL ADHESIVE, TAPE, NAILS, HANGERS, ANCHORS, ETC. FROM EXISTING WALLS TO RECEIVE NEW
PAINT
DEMOLITION PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
TAKE CARE WHEN REMOVING PANELS.
SALVAGE AND RETURN TO OWNER EXISTING
ACOUSTICAL WALL PANELS.
106' - 10"6' - 10" A.F.F
14' - 10" A.F.F
TAKE CARE WHEN REMOVING PANELS.
SALVAGE AND RETURN TO OWNER EXISTING
ACOUSTICAL WALL PANELS.
107' - 0"
115' - 0"
6' - 10" A.F.F
14' - 10" A.F.F
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:1
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
AUDITORIUM 160
DEMOLITION PLANS
A2.10
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/8" 1'-0"A2.10
1 AUDITORIUM 160 DEMOLITION PLAN
1/4" 1'-0"A2.10
2 AUDITORIUM 160 DEMOLITION SOUTH WEST ELEVATION
1/4" 1'-0"A2.10
3 AUDITORIUM 160 DEMOLITION SOUTH EAST ELEVATION
TRUE
NORTH
BAND ROOM
A2.50
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ARCHITECT HAS FIELD VERIFIED CRITICAL DIMENSIONS AND USED OWNER'S ORIGINAL DOCUMENT TO GENERATE THESE DRAWINGS. CONTACT THE ARCHITECT IMMEDIATELY IF SUBSTANTIAL DIFFERENCES
BETWEEN DIMENSIONS INDICATED DIFFER FROM THOSE ENCOUNTERED.
DASHED LINES INDICATE BUILDING MATERIALS TO BE REMOVED IN THEIR ENTIRETY, U.N.O. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DEMOLITION PLANS FOR SPECIFIC TRADE WORK TO BE DONE IN
THESE AREAS.
ALL DEMOLITION DEBRIS TO BE DISPOSED OF OFF SITE IN LEGAL WASTE FACILITY BY THE GENERAL
CONTRACTOR. UTILIZE COVERED TRANSPORTATION CARTS THROUGH THE BUILDING.
EXERCISE CAUTION NOT TO DAMAGE EXISTING FINISHES & UNDER-LYING SURFACES DURING
DEMOLITION WORK CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE.
PRIOR TO ALL DEMOLITION WORK, REFER TO HAZARDOUS MATERIAL INSPECTION REPORT AND ABATE
ALL IDENTIFIED MATERIAL AS REQUIRED.
CONSULT WITH OWNER AND DEVELOP A SAFETY AND EVACUATION PLAN WHICH MAINTAINS CRITICAL
EGRESS PATHS.
NOTIFY ARCHITECT IMMEDIATELY UPON DETECTING DISCREPANCIES BETWEEN DRAWINGS & EXISTING
FIELD CONDITIONS.
THE CONTRACTOR SHALL SCHEDULE, COORDINATE AND CONDUCT A PRE-DEMOLITION CONFERENCE
FOR THE PROJECT PRIOR TO STARTING THE WORK.
REMOVE AND SALVAGE IDENTIFIED ITEMS, EXISTING EQUIPMENT, SIGNAGE AND FURNISHINGS FROM THE EXISTING STRUCTURES AS REQUIRED. COORDINATE ALL ITEMS TO BE SALVAGED WITH THE
OWNER.
REMOVE ALL ADHESIVE, TAPE, NAILS, HANGERS, ANCHORS, ETC. FROM EXISTING WALLS TO RECEIVE
NEW PAINT
DEMOLITION PLAN GENERAL NOTES
1.
2.
REMOVE AND SALVAGE PYRAMIDAL ACOUSTICAL PANEL. TAKE CARE NOT TO DAMAGE ACOUSTICAL
PANEL AND GRID WHEN REMOVING.
REMOVE, SALVAGE AND RETURN TO OWNER EXISTING ACOUSTICAL WALL PANELS. TAKE CARE
WHEN REMOVING PANELS. REMOVE ALL ADHESIVE AND CLIPS BEHIND PANELS.
BAND ROOM 161 DEMOLITION KEYNOTES: #
BAND 161 LEGEND
PYRAMIDAL ACOUSTICAL PANELS, TO REMAIN AS IS
PYRAMIDAL ACOUSTICAL PANELS TO BE REMOVED
AND SALVAGED.
12' - 0"
12' - 10"
2 2 2 222 2 2 2
112' - 4"
107' - 4"
2 2 2 2 2 2 2 2
107' - 4"
111' - 4"
EXISTING PEG BOARD
2 2 2 2 2
107' - 4"
111' - 4"
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:1
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
BAND ROOM 161
DEMOLITION PLANS
A2.50
CK/JFH
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/4" 1'-0"A2.50
1 BAND ROOM 161 DEMOLITION PLAN
TRUE
NORTH
1/4" 1'-0"A2.50
2 BAND ROOM 161 DEMOLITION REFLECTED CEILING PLAN
TRUE
NORTH
1/4" 1'-0"A2.50
3 BAND ROOM 161 DEMOLITION NORTH ELEVATION
1/4" 1'-0"A2.50
4 BAND ROOM 161 DEMOLITION EAST ELEVATION
1/4" 1'-0"A2.50
5 BAND ROOM 161 DEMOLITION WEST ELEVATION
11' - 11"
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
ARCHITECT HAS FIELD VERIFIED CRITICAL DIMENSIONS AND USED OWNER'S ORIGINAL DOCUMENT TO GENERATE THESE DRAWINGS. CONTACT THE ARCHITECT IMMEDIATELY IF SUBSTANTIAL DIFFERENCES
BETWEEN DIMENSIONS INDICATED DIFFER FROM THOSE ENCOUNTERED.
DASHED LINES INDICATE BUILDING MATERIALS TO BE REMOVED IN THEIR ENTIRETY, U.N.O. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DEMOLITION PLANS FOR SPECIFIC TRADE WORK TO BE DONE IN
THESE AREAS.
ALL DEMOLITION DEBRIS TO BE DISPOSED OF OFF SITE IN LEGAL WASTE FACILITY BY THE GENERAL
CONTRACTOR. UTILIZE COVERED TRANSPORTATION CARTS THROUGH THE BUILDING.
EXERCISE CAUTION NOT TO DAMAGE EXISTING FINISHES & UNDER-LYING SURFACES DURING
DEMOLITION WORK CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE.
PRIOR TO ALL DEMOLITION WORK, REFER TO HAZARDOUS MATERIAL INSPECTION REPORT AND ABATE
ALL IDENTIFIED MATERIAL AS REQUIRED.
CONSULT WITH OWNER AND DEVELOP A SAFETY AND EVACUATION PLAN WHICH MAINTAINS CRITICAL
EGRESS PATHS.
NOTIFY ARCHITECT IMMEDIATELY UPON DETECTING DISCREPANCIES BETWEEN DRAWINGS & EXISTING
FIELD CONDITIONS.
THE CONTRACTOR SHALL SCHEDULE, COORDINATE AND CONDUCT A PRE-DEMOLITION CONFERENCE
FOR THE PROJECT PRIOR TO STARTING THE WORK.
REMOVE AND SALVAGE IDENTIFIED ITEMS, EXISTING EQUIPMENT, SIGNAGE AND FURNISHINGS FROM THE EXISTING STRUCTURES AS REQUIRED. COORDINATE ALL ITEMS TO BE SALVAGED WITH THE
OWNER.
REFER TO THE MECHANICAL & ELECTRICAL DRAWINGS FOR RELATED MECHANICAL AND ELECTRICAL
DEMOLITION WORK.
REMOVE ALL ADHESIVE, TAPE, NAILS, HANGERS, ANCHORS, ETC. FROM EXISTING WALLS TO RECEIVE
NEW PAINT
DEMOLITION PLAN GENERAL NOTES
ENSEMBLE 163 LEGEND
PYRAMIDAL ACOUSTICAL PANELS, TO REMAIN AS IS
PYRAMIDAL ACOUSTICAL PANELS TO BE REMOVED
AND SALVAGED.
1. REMOVE AND SALVAGE PYRAMIDAL ACOUSTICAL PANEL. TAKE CARE NOT TO DAMAGE ACOUSTICAL
PANEL AND GRID WHEN REMOVING.
ENSEMBLE ROOM 163 DEMOLITION KEYNOTES: #
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:2
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
ENSEMBLE ROOM 163
DEMOLITION PLANS
A2.60
CK/JFH
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/4" 1'-0"A2.60
2 ENSEMBLE 163 DEMOLITION REFLECTED CEILING PLAN
TRUE
A3.10
5A3.10
A3.10 3
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ARCHITECT HAS USED DOCUMENTS PROVIDED BY THE OWNER TO GENERATE THESE BASE PLAN
DRAWINGS, THOUGH A FEW CRITICAL DIMENSIONS HAVE BEEN FIELD VERIFIED. CONTACT THE
ARCHITECT IMMEDIATELY IF SUBSTANTIAL DIFFERENCES BETWEEN DIMENSIONS INDICATED DIFFER
FROM THOSE ENCOUNTERED.
THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS AND ROOM AREAS PRIOR TO STARTING CONSTRUCTION ON THE PROJECT. F.V. DENOTES DIMENSION TO BE FIELD VERIFIED BY
CONTRACTOR PRIOR TO BEGINNING CONSTRUCTION.
PROVIDE FIRE TREATED BLOCKING AS REQUIRED FOR ATTACHMENTS
ALL INTERIOR FINISHES, PLANES, LINES & CORNERS MUST BE STRAIGHT, NEAT, & CLEAN. ANY SAME
MATERIALS ABUTTING EACH OTHER MUST ALIGN. EDGES SHALL BE SHARP AND TRUE.
FURNITURE AND EQUIPMENT ARE NOT INCLUDED UNLESS NOTED OTHERWISE (U.N.O.), ONLY
SHOWN FOR CLARITY.
PATCH AND REPAIR OR REPLACE ANY WALLS, FLOORS OR EQUIPMENT DAMAGED AS A RESULT OF
DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND CONDITION.
ALL LOOSE FURNITURE FIXTURES AND EQUIPMENT NOTED ARE FOR REFERENCE ONLY. BUILT IN
COMPONENTS INCLUDED IN CONTRACT ARE INDICATED ON INTERIOR ELEVATIONS.
ALL WALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF MASONRY UNLESS NOTED OTHERWISE.
SEE ENLARGED PLANS (AS PROVIDED) FOR ADDITIONAL DIMENSIONS AND INFORMATION.
COLOR’S SUBJECT TO CHANGE WITHIN PRODUCT ’S STANDARD COLOR RANGE UNLESS OTHERWISE
NOTED. DURING SUBMITTAL PROVIDE COLOR SAMPLE OF EACH COLOR IN PRODUCTS STANDARD
COLOR RANGE FOR FINAL COLOR DETERMINATION. FINAL APPROVAL FROM ARCHITECT REQUIRED
BEFORE PURCHASE.
FLOOR PLAN GENERAL NOTES
113' - 0"3' - 8" A.F.F
128' - 0"18' - 8" A.F.F
1' - 10 3/4" 3' - 6"3' - 9"3' - 6"3' - 6"3' - 9"3' - 6"1' - 9"
2' 0"
3' 6"
2' 4"
2 2 2 2 2 2 2 2 2 2 2 2
55 5 5
1.
2.
3.
4.
5.
6.
7.
NEW 4'X8' TUNED ABSORBER / DIFFUSER PANELS IN 408 BLACK WITH SQUARE EDGE DIRECTLY
APPLIED TO WALL WITH Z-CLIPS, PER MANUFACTURER ’S RECOMMENDATION. PANELS TO BE
CENTERED ALONG LENGTH OF WALL TOUCH UP WALL PAINT IF AFFECTED BY NEW CONSTRUCTION.
NEW MODIFIED 4'X8' / CUSTOM SIZED 3'X8' TUNED ABSORBER / DIFFUSER PANELS, PER ELEVATION, IN 408 BLACK WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER
MANUFACTURER’S RECOMMENDATION. CUT PANELS AROUND JOISTS. PANELS TO BE CENTERED
ALONG LENGTH OF WALL. TOUCH UP WALL PAINT IF AFFECTED BY NEW CONSTRUCTION.
NEW MODIFIED 4'X4' / CUSTOM SIZED TUNED ABSORBER / DIFFUSER PANELS, PER ELEVATION, IN 144 EGGSHELL WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER MANUFACTURER ’S
RECOMMENDATION. MATCHING WINDOW SPACING. TOUCH UP WALL PAINT IF AFFECTED BY NEW
CONSTRUCTION.
NEW 2'X8' TUNED ABSORBER / DIFFUSER PANELS, PER ELEVATION, IN 408 BLACK WITH SQUARE
EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER MANUFACTURER ’S RECOMMENDATION.
PANELS TO BE PLACED BETWEEN SPLIT FACE CMU STRIPS.
PANELS TO BE CUT AROUND EXISTING CONDUIT AS TIGHTLY AS POSSIBLE, TYPICAL.
EXISTING CLOCK AND SPEAKER, TO REMAIN CUT PANELS AROUND.
EXISTING WALL MOUNTED PROJECTOR, TO REMAIN CUT PANELS AROUND.
AUDITORIUM 160 KEYNOTES: #
AUDITORIUM 160 ELEVATION LEGEND
4'X8'/3'X8'/2'X8' TUNED ABSORBER / DIFFUSER
PANELS IN 408 BLACK WITH SQUARE EDGE
MODIFIED 4'X4' TUNED ABSORBER / DIFFUSER
PANELS IN 144 EGGSHELL WITH SQUARE EDGE
113' - 2"
126' - 3"
4 4
4 4
4 4
3' - 8" A.F.F
16' - 9 3/8" A.F.F
113' - 2"
126' - 3"
3' - 8" A.F.F
16' - 9 3/8" A.F.F
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:4
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
AUDITORIUM FLOOR
160 AND INTERIOR
ELEVATIONS
A3.10
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/8" 1'-0"A3.10
1 AUDITORIUM 160 FLOOR PLAN
1/4" 1'-0"A3.10
5 AUDITORIUM 160 SOUTH WALL
TRUE
NORTH
1/4" 1'-0"A3.10
2 AUDITORIUM 160 WEST ELEVATION
1/4" 1'-0"A3.10
3 AUDITORIUM 160 EAST ELEVATION
A5.20 1
EXISTING UNIT
EXISTING AHU
SLOPED METAL
DECK
HEIGHT VARIES
EXISTING AHU
EXISTING AHU
TY
P.
1' 5/ 8"
TY
P.
1' 5/ 8"
TYP.
6"
TYP.
1' - 0"
TYP.
1' - 0"
TYP.
6"
TYP.
3' - 0"
TYP.
2' - 5"
TY
P.
1' 5/ 8"
TY
P.
1' 5/ 8"
TY
P.
1' 5/ 8"
TY
P.
1' 5/ 8"
TY
P.
1' 5/ 8"
TY
P.
1' 5/ 8"
22 2
22 2
2 2
22 2
22 2
22 2
1 4
TYP. TYP.
A5.202
A3.20
A3.20
A3.20
A5.21
A5.21
1.
2.
3.
4.
CEILING HEIGHT TO BE AS NOTED ON PLANS UNLESS NOTED OTHERWISE.
ALL CEILING GRID PENETRATIONS TO BE IN CENTER OF PANEL UNLESS SHOWN OTHERWISE.
THIS PLAN IS INTENDED TO SHOW THE GENERAL CONFIGURATION AND MATERIALS OF THE
CEILINGS ONLY. LIGHTING AND HVAC SHOWN ON THIS PLAN IS REPRESENTATIVE.
COLOR’S SUBJECT TO CHANGE WITHIN PRODUCT ’S STANDARD COLOR RANGE UNLESS
OTHERWISE NOTED. DURING SUBMITTAL PROVIDE COLOR SAMPLE OF EACH COLOR IN PRODUCTS
STANDARD COLOR RANGE FOR FINAL COLOR DETERMINATION. FINAL APPROVAL FROM ARCHITECT
REQUIRED BEFORE PURCHASE.
REFLECTED CEILING PLAN GENERAL NOTES
1.
2.
3.
4.
3'X15' WAVE BAFFLES IN SILVER GRAY TO FOLLOW SLOPE OF ROOF DECK AND ATTACHED
DIRECTLY TO DECK ON TWO ENDS AND CENTER, TYPICAL UNLESS NOTED OTHERWISE. ENSURE A MINIMUM OF 1" GAP BETWEEN BOTTOM OF BAFFLE AND TOP OF SPRINKLER HEAD IS MAINTAINED, SEE ATTACHMENT DETAIL 2/A3.20. CENTER BAFFLES EVENLY BETWEEN JOISTS AND ALIGN
ACROSS BAYS. CONTRACTOR TO FIELD VERIFY EACH SPRINKLER HEAD HEIGHT AND DOCUMENT
BOTH HEIGHT OF BOTTOM OF EACH BAFFLE AND HEIGHT OF TOP OF EACH SPRINKLER HEAD,
SHOWING A MINIMUM OF 1" GAP IS MAINTAINED BETWEEN THEM.
3'X15' WAVE BAFFLES IN CUSTOM ORANGE, MATCHING SCHOOL COLOR, TO FOLLOW SLOPE OF
ROOF DECK AND ATTACHED DIRECTLY TO DECK ON TWO ENDS AND CENTER, TYPICAL UNLESS
NOTED OTHERWISE. ENSURE A MINIMUM OF 1" GAP BETWEEN BOTTOM OF BAFFLE AND TOP OF
SPRINKLER HEAD IS MAINTAINED, SEE ATTACHMENT DETAIL 2/A3.20. CENTER BAFFLES EVENLY
BETWEEN JOISTS AND ALIGN ACROSS BAYS. CONTRACTOR TO FIELD VERIFY EACH SPRINKLER
HEAD HEIGHT AND DOCUMENT BOTH HEIGHT OF BOTTOM OF EACH BAFFLE AND HEIGHT OF TOP
OF EACH SPRINKLER HEAD, SHOWING A MINIMUM OF 1" GAP IS MAINTAINED BETWEEN THEM.
PROVIDE DEDUCTIVE ALTERNATE FOR BAFFLES TO BE BLACK INSTEAD OF CUSTOM ORANGE.
3' WIDE BY CUSTOM LENGTH WAVE BAFFLES TO ALIGN WITH ARCH OF ADJACENT 3 ’X15’ PANELS, IN SILVER GRAY TO FOLLOW SLOPE OF ROOF DECK AND ATTACHED DIRECTLY TO DECK ON TWO
ENDS AND CENTER, TYPICAL UNLESS NOTED OTHERWISE. ENSURE A MINIMUM OF 1" GAP
BETWEEN BOTTOM OF BAFFLE AND TOP OF SPRINKLER HEAD IS MAINTAINED, SEE ATTACHMENT
DETAIL 2/A3.20. CENTER BAFFLES EVENLY BETWEEN JOISTS AND ALIGN ACROSS BAYS.
CONTRACTOR TO FIELD VERIFY EACH SPRINKLER HEAD HEIGHT AND DOCUMENT BOTH HEIGHT
OF BOTTOM OF EACH BAFFLE AND HEIGHT OF TOP OF EACH SPRINKLER HEAD, SHOWING A
MINIMUM OF 1" GAP IS MAINTAINED BETWEEN THEM.
CONTRACTOR TO PROVIDE LOAD CALCULATION FOR BAFFLES, TYPICAL.
GYMNASIUM 180 RCP KEYNOTES: #
GYMNASIUM 180 REFLECTED CEILING LEGEND
3'X15' WAVE BAFFLES IN SILVER GRAY
3'X15' WAVE BAFFLES IN ORANGE
CUSTOM SIZED WAVE BAFFLES TO MATCH ARCH OF ADJACENT BAFFLES
EXISTING LIGHT FIXTURE
WOOD STRIPS, PART OF BAFFLE
HEAT BONDED WAVE
BAFFLE W/ 2" THICK 1
PCF FIBERGLASS CORE
HEAT SEALED
VINYL
EXISTING 1-1/2"
METAL DECK
#10 SELF-TAPPING SHEET METAL
SCREW AND FENDER WASHER
THROUGH BAFFLE AT THREE POINTS
ON EACH END, 2" FROM EDGE, NOT
PROVIDED WITH BAFFLE
PEAK OF ROOF
HANGING ATTACHMENT,
TYPICAL
HANGING ATTACHMENT,
TYPICAL
SPRINKLER
HEAD
SPRINKLER
HEAD
M
IN
1"
M
IN
1"
1 1
1" MINIMUM CLEARANCE
REQUIRED FROM TOP OF
SPRINKLER HEAD TO
BOTTOM OF BAFFLE
1" MINIMUM CLEARANCE
REQUIRED FROM TOP OF
SPRINKLER HEAD TO
BOTTOM OF BAFFLE
WOOD STRIPS, PART OF BAFFLE
HEAT BONDED WAVE
BAFFLE W/ 2" THICK 1
PCF FIBERGLASS CORE
EXISTING 1-1/2"
METAL DECK
#10 SELF-TAPPING SHEET METAL
SCREW AND FENDER WASHER
THROUGH BAFFLE AT THREE POINTS AT
CENTER, 2" FROM EDGE, NOT
PROVIDED WITH BAFFLE
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:4
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
GYMNASIUM 180
REFLECTED CEILING
PLAN AND INTERIOR
ELEVATIONS
A3.20
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
TRUE
NORTH
1/8" 1'-0"A3.20
1 GYMNASIUM 180 REFLECTED CEILING PLAN
3" 1'-0"A3.20
2 WAVE BAFFLE DECK ATTACHMENT END CONNECTIONS
1/4" 1'-0"A3.20
3 WAVE BAFFLE MINIMUM CLEARANCE FROM SPRINKLER HEADS
3" 1'-0"A3.20
4 WAVE BAFFLE DECK ATTACHMENT CENTER CONNECTION
5A21
BOOKCASES
BO
O
KC
AS
ES
BO
O
KC
AS
ES
215B
HISTORIC
DESIGNATION
LIBRARY/COMPUTER
ROOM
A3.30
4 4
1 1
TYP.
2"
TY
P.2"
TYP.
2"
TY
P.2"
3 3
GYPSUM BOARD
11' - 6" A.F.F.
GYPSUM BOARD
11' - 6" A.F.F.
1.
2.
3.
4.
5.
6.
7.
NEW 4'X4' ACOUSTICAL WRAPPED PANELS IN 144 EGGSHELL WITH SQUARE EDGE, DIRECTLY
APPLIED TO THE CEILING WITH Z-CLIPS, PER MANUFACTURER’S RECOMMENDATION. TO BE
CENTERED IN CEILING.
NEW 4'X3' ACOUSTICAL WRAPPED PANELS IN 144 EGGSHELL WITH SQUARE EDGE, DIRECTLY
APPLIED TO THE CEILING WITH Z-CLIPS, PER MANUFACTURER’S RECOMMENDATION. TO BE
CENTERED IN CEILING.
TOUCH-UP CEILING OR WALL PAINT IF AFFECTED BY NEW CONSTRUCTION, TYPICAL.
NEW 4'X8' OR 4'X8' MODIFIED ACOUSTICAL WRAPPED PANELS, IN 406 SILVER NETURAL WITH
SQUARE EDGE, DIRECTLY APPLIED TO THE WALL WITH Z-CLIPS, PER MANUFACTURER ’S
RECOMMENDATION.
NEW 2'X8' ACOUSTICAL WRAPPED PANELS IN 406 SILVER NETURAL WITH ROUND EDGE OFF SET
WITH WOOD BLOCKING AND APPLIED WITH Z-CLIPS, PER MANUFACTURER ’S RECOMMENDATION.
CENTER AT HIGH POINT OF ARCH. DIRECTLY APPLIED TO THE WALL.
REMOVE, SALVAGE AND REINSTALL AFTER ACOUSTICAL WRAPPED WALL PANELS ARE INSTALLED.
CUT BOTTOM OF OFFSET PANEL WITH A SQUARE EDGE. PROVIDE WOOD BLOCKING BEHIND PANEL
FLUSH WITH BOTTOM TO FILL GAP BETWEEN WALL AND PANEL. PAINT TO PATCH PANEL.
HISTORIC LIBRARY 215 KEYNOTES: #
WHITEBOARD
554 4
BULLETEN
BOARD
MARKER
BOARD
EXITEXIT
F.V.
1' - 6 3/4"8' - 0"2' - 0"8' - 0"
F.V.
1' - 6 3/4"
F.V.
3' - 5" 8' - 0" 2' - 0" 8' - 0"
F.V.
3' - 5"
2' 1/ 2"
4' 6"6' 1/ 4"
A3.30 4
A3.30
3 3
TYP. TYP. TYP.TYP.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ARCHITECT HAS USED DOCUMENTS PROVIDED BY THE OWNER TO GENERATE THESE BASE PLAN
DRAWINGS, THOUGH A FEW CRITICAL DIMENSIONS HAVE BEEN FIELD VERIFIED. CONTACT THE
ARCHITECT IMMEDIATELY IF SUBSTANTIAL DIFFERENCES BETWEEN DIMENSIONS INDICATED
DIFFER FROM THOSE ENCOUNTERED.
THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS AND ROOM AREAS PRIOR
TO STARTING CONSTRUCTION ON THE PROJECT. F.V. DENOTES DIMENSION TO BE FIELD VERIFIED
BY CONTRACTOR PRIOR TO BEGINNING CONSTRUCTION.
CONTRACTOR FIELD VERIFY LOCATION, POSITION, FUNCTION AND SOURCE OF AN EXISTING
UTILITY SERVICES.
PROVIDE FIRE TREATED BLOCKING AS REQUIRED FOR ATTACHMENTS.
ALL INTERIOR FINISHES, PLANES, LINES & CORNERS MUST BE STRAIGHT, NEAT, & CLEAN. ANY
SAME MATERIALS ABUTTING EACH OTHER MUST ALIGN. EDGES SHALL BE SHARP AND TRUE.
ALL LOOSE FURNITURE FIXTURES AND EQUIPMENT NOTED ARE FOR REFERENCE ONLY. BUILT IN
COMPONENTS INCLUDED IN CONTRACT ARE INDICATED ON INTERIOR ELEVATIONS.
ALL WALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF MASONRY UNLESS NOTED
OTHERWISE.
PROVIDE TRANSITION STRIPS AT ALL DISSIMILAR FLOOR MATERIALS.
SEE ENLARGED PLANS (AS PROVIDED) FOR ADDITIONAL DIMENSIONS AND INFORMATION.
COLOR’S SUBJECT TO CHANGE WITHIN PRODUCT ’S STANDARD COLOR RANGE UNLESS
OTHERWISE NOTED. DURING SUBMITTAL PROVIDE COLOR SAMPLE OF EACH COLOR IN PRODUCTS
STANDARD COLOR RANGE FOR FINAL COLOR DETERMINATION. FINAL APPROVAL FROM
ARCHITECT REQUIRED BEFORE PURCHASE.
FLOOR PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
CEILING HEIGHT TO BE AS NOTED ON PLANS UNLESS NOTED OTHERWISE.
COORDINATE ALL FRAMING WITH ELECTRICAL, MECHANICAL AND PLUMBING.
ALL CEILING TO BE IN CENTER OF PANEL UNLESS SHOWN OTHERWISE.
THIS PLAN IS INTENDED TO SHOW THE GENERAL CONFIGURATION AND MATERIALS OF THE
CEILINGS ONLY. LIGHTING AND HVAC SHOWN ON THIS PLAN ARE REPRESENTATIVE, REFER TO
MECHANICAL AND ELECTRICAL FOR SPECIFIC LOCATIONS AND SIZES FOR HVAC GRILLS,
EQUIPMENT, EXPOSED DUCTS, LIGHTING FIXTURES, ETC...
CENTER CEILING IN AREAS UNLESS SHOWN OTHERWISE COORDINATE LAYOUT WITH ARCHITECT
PRIOR TO INSTALLATION.
COLOR’S SUBJECT TO CHANGE WITHIN PRODUCT ’S STANDARD COLOR RANGE UNLESS
OTHERWISE NOTED. DURING SUBMITTAL PROVIDE COLOR SAMPLE OF EACH COLOR IN PRODUCTS
STANDARD COLOR RANGE FOR FINAL COLOR DETERMINATION. FINAL APPROVAL FROM
ARCHITECT REQUIRED BEFORE PURCHASE.
REFLECTED CEILING PLAN GENERAL NOTES
1" x 2" WOOD BLOCKING TYPICAL
ACOUSTICAL PANELS WITH SQUARE EDGE ALIGN WITH EDGE OF BEVELED PANEL
2' - 0"
ACOUSTICAL PANEL WITH RADIUS EDGE
1"
FIRE ALARM STROBE CENTERED IN PANEL
WITH WIRING RUNNING ON BACK SIDE OF
PANEL BETWEEN BLOCKING
ACOUSTICAL PANEL WITH
RADIUS EDGE
EXISTING WALL
HISTORIC LIBRARY 215 LEGEND
4'X4'/4'X3' ACOUSTICAL WRAPPED PANELS IN 144 EGGSHELL
4'X8'/4'X8' MODIFIED ACOUSTICAL WRAPPED PANELS, IN 406 SILVER
NETURAL WITH SQUARE EDGE
2'X8' ACOUSTICAL WRAPPED PANELS IN 406 SILVER NETURAL WITH
ROUND EDGE
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:4
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
HISTORIC LIBRARY
215 FLOOR AND
REFLECTED CEILING
PLANS
A3.30
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/4" 1'-0"A3.30
1 HISTORIC LIBRARY 215 FLOOR PLAN
1/4" 1'-0"A3.30
2 HISTORIC LIBRARY 215 REFLECTED CEILING PLAN
TRUE
NORTH
1/4" 1'-0"A3.30
3 HISTORIC LIBRARY 215 NORTH ELEVATION
3" 1'-0"A3.30
4 ABSORPTION PANEL DETAIL
TRUE
A3.40
DANCE STUDIO
282A
7' - 5"
6'
2" HYDRONIC
HEATING/COOLING
UNIT
1ALIGN
A3.40
8' - 6"
A3.40
O.C. TYP.
4' - 0"
1' 1/ 2"
1.
2.
3.
4.
5.
NEW SUSPENDED QUILTED FIBERGLASS ACOUSTICAL BLANKET SYSTEM FROM WALL TO
WALL AND BASE OF MECHANICAL FLOOR TO BOTTOM OF JOISTS. CONTRACTOR TO
VERIFY SPECIFIC SIZE, DESIGN AND REQUIREMENTS WITH MANUFACTURER AS SYSTEM
IS MADE PROJECT SPECIFIC AND FACTORY CUT TO SIZE.
SINGLE CURTAIN TRACK PER MANUFACTURE.
VELCRO ATTACHMENT BETWEEN PANELS, PROVIDED WITH THE SYSTEM.
VELCRO BOTTOM OF CURTAIN TO EDGE OF CONCRETE FLOOR, CLOSING GAP BETWEEN
CURTAIN AND LANDING OF MECHANICAL UNIT.
3/8" THREADED ROD AT 48" O.C. SUSPENDING CURTAIN TRACK FROM DECK.
DANCE STUDIO 282A KEYNOTES: #
1.
2.
3.
4.
5.
6.
7.
8.
9.
ARCHITECT HAS USED DOCUMENTS PROVIDED BY THE OWNER TO GENERATE THESE BASE PLAN
DRAWINGS, THOUGH A FEW CRITICAL DIMENSIONS HAVE BEEN FIELD VERIFIED. CONTACT THE
ARCHITECT IMMEDIATELY IF SUBSTANTIAL DIFFERENCES BETWEEN DIMENSIONS INDICATED
DIFFER FROM THOSE ENCOUNTERED.
THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS AND ROOM AREAS PRIOR
TO STARTING CONSTRUCTION ON THE PROJECT. F.V. DENOTES DIMENSION TO BE FIELD VERIFIED
BY CONTRACTOR PRIOR TO BEGINNING CONSTRUCTION.
CONTRACTOR FIELD VERIFY LOCATION, POSITION, FUNCTION AND SOURCE OF AN EXISTING
UTILITY SERVICES.
PROVIDE FIRE TREATED BLOCKING AS REQUIRED FOR ATTACHMENTS.
ALL INTERIOR FINISHES, PLANES, LINES & CORNERS MUST BE STRAIGHT, NEAT, & CLEAN. ANY
SAME MATERIALS ABUTTING EACH OTHER MUST ALIGN. EDGES SHALL BE SHARP AND TRUE.
FURNITURE AND EQUIPMENT ARE NOT INCLUDED UNLESS NOTED OTHERWISE (U.N.O.), ONLY
SHOWN FOR CLARITY.
PATCH AND REPAIR OR REPLACE ANY WALLS, FLOORS OR EQUIPMENT DAMAGED AS A RESULT OF
DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND CONDITION.
ALL LOOSE FURNITURE FIXTURES AND EQUIPMENT NOTED ARE FOR REFERENCE ONLY. BUILT IN
COMPONENTS INCLUDED IN CONTRACT ARE INDICATED ON INTERIOR ELEVATIONS.
ALL WALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF MASONRY UNLESS NOTED
OTHERWISE.
10. SEE ENLARGED PLANS (AS PROVIDED) FOR ADDITIONAL DIMENSIONS AND INFORMATION.
FLOOR PLAN GENERAL NOTES
EXISTING HYDRONIC
HEATING/COOLING UNIT
TRACK END STOP AT
EACH END, PROVIDED
WITH SYSTEM
TROLLEYS, PROVIDED WITH SYSTEM
SINGLE CURTAIN TRACK, PROVIDED WITH SYSTEM
A3.40
1" QUILTED CURTAIN, PROVIDED WITH SYSTEM
3/8" THREADED ROD AT 48" O.C. ALONG
LENGTH OF TRACK, NOT INCLUDED WITH
SYSTEM
CEILING SUSPEND SINGLE
TRACK MOUNTING BRACKET,
PROVIDED WITH SYSTEM
1-1/2" NUT WITH WASHER ON TOP AND
BOTTOM OF MOUNTING BRACKET, NOT
INCLUDED WITH SYSTEM
EXISTING 1-1/2"
METAL DECK
3/8" THREADED ROD,
NOT PROVIDED WITH
SYSTEM
3/8" x 2-1/2" ROD
HANGER SCREW
ANCHOR, NOT
PROVIDED WITH
SYSTEM
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:4
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
DANCE STUDIO 282A
FLOOR AND
REFLECTED CEILING
PLAN
A3.40
JH/CK
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
TRUE
NORTH
1/4" 1'-0"A3.40
1 DANCE STUDIO 282A FLOOR PLAN - OPTION 01
1/4" 1'-0"A3.40
4 DANCE STUDIO 282A NORTH ELEVATION - OPTION 01
12" 1'-0"A3.40
2 SUSPENDED CEILING SYSTEM
12" 1'-0"A3.40
5 SUSPENDED CEILING SYSTEM DETAIL
3" 1'-0"A3.40
3 SUSPENDED CEILING SYSTEM DECK ATTACHMENT
BAND ROOM
A3.50
A3.505 A3.50
12' - 10"
12' - 0"
1.
2.
3.
4.
5.
6.
CEILING HEIGHT TO BE AS NOTED ON PLANS UNLESS NOTED OTHERWISE.
COORDINATE WITH ELECTRICAL, MECHANICAL AND PLUMBING.
COORDINATE ALL CEILING FIXTURES AND EQUIPMENT WITH MECHANICAL AND ELECTRICAL DRAWINGS
PROVIDED WITHIN THESE DOCUMENTS.
THIS PLAN IS INTENDED TO SHOW THE GENERAL CONFIGURATION AND MATERIALS OF THE CEILINGS ONLY.
CENTER CEILING GRID IN AREAS UNLESS SHOWN OTHERWISE COORDINATE LAYOUT WITH ARCHITECT
PRIOR TO INSTALLATION.
COLOR’S SUBJECT TO CHANGE WITHIN PRODUCT ’S STANDARD COLOR RANGE UNLESS OTHERWISE NOTED.
DURING SUBMITTAL PROVIDE COLOR SAMPLE OF EACH COLOR IN PRODUCTS STANDARD COLOR RANGE FOR FINAL COLOR DETERMINATION. FINAL APPROVAL FROM ARCHITECT REQUIRED BEFORE PURCHASE.
REFLECTED CEILING PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
NEW 4'X8' TUNED ABSORBER / DIFFUSER PANELS IN 406 SILVER NETURAL WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER MANUFACTURER ’S RECOMMENDATION. PANELS TO BE PLACED PER
ELEVATION. TOUCH UP WALL PAINT IF AFFECTED BY NEW CONSTRUCTION.
NEW MODIFIED 4'X8' / CUSTOM SIZED 4'X7' TUNED ABSORBER / DIFFUSER PANELS, PER ELEVATION, IN 406 SILVER NETURAL WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER MANUFACTURER ’S RECOMMENDATION. PANELS TO BE PLACED PER ELEVATION. TOUCH UP WALL PAINT IF AFFECTED BY NEW
CONSTRUCTION.
PANELS TO BE CUT AROUND WINDOWS.
RELOCATED PYRAMIDAL ACOUSTICAL PANELS.
REPAIR GRID AND TILE TO MATCH EXISTING ACOUSTICAL CEILING AT REMOVED PYRAMIDAL ACOUSTICAL
PANEL.
REPAIR ANY DAMAGE FROM ACOUSTICAL PANEL REMOVAL AND PAINT WALLS CORNER TO CORNER. TO
MATCH EXISTING.
COLOR’S SUBJECT TO CHANGE WITHIN PRODUCT ’S STANDARD COLOR RANGE UNLESS OTHERWISE NOTED.
DURING SUBMITTAL PROVIDE COLOR SAMPLE OF EACH COLOR IN PRODUCTS STANDARD COLOR RANGE FOR FINAL COLOR DETERMINATION. FINAL APPROVAL FROM ARCHITECT REQUIRED BEFORE PURCHASE.
BAND ROOM 161 KEYNOTES: #
BAND 161 LEGEND
EXISTING PYRAMIDAL ACOUSTICAL PANELS
RELOCATED PYRAMIDAL ACOUSTICAL PANELS
4'X8' TUNED ABSORBER / DIFFUSER PANELS IN 406
SILVER NETURAL
1 3 3 3 1 1
107' - 4"
111' - 4"
1 1 1 2
107' - 4"
111' - 4"
EXISTING PEG BOARD
1 1 1 2
107' - 4"
111' - 4"
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:4
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
BAND ROOM 161
FLOOR AND
REFLECTED CEILING
PLANS
A3.50
CK/JFH
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/4" 1'-0"A3.50
1 BAND ROOM 161 FLOOR PLAN 1/4" 1'-0"A3.50
2 BAND ROOM 161 REFLECTED CEILING PLAN
TRUE
NORTH
TRUE
NORTH
1/4" 1'-0"A3.50
3 BAND ROOM 161 NORTH ELEVATION
1/4" 1'-0"A3.50
4 BAND ROOM 161 EAST ELEVATION
1/4" 1'-0"A3.50
5 BAND ROOM 161 WEST ELEVATION
ENSEMBLE
A3.60
A3.60
A3.60
A3.606
11' - 11"
11' - 4"
7' - 4"
T.V.
WOOD SHELF
EXIT EXIT
12 1 1
7' - 4"
WALL MOUNTED SPEAKER
111' - 4"
1 1
11' - 4"
7' - 4"
CONDUIT FROM CEILING WITH
OUTLET BOX, NO OUTLET
WALL MOUNTED
SPEAKER
CENTER ON WALL
25' - 10 5/8"
A3.60 1 1
WALL MOUNTED SPEAKER
11' - 4"
7' - 4"
1.
2.
3.
4.
5.
6.
CEILING HEIGHT TO BE AS NOTED ON PLANS UNLESS NOTED OTHERWISE.
COORDINATE WITH ELECTRICAL, MECHANICAL AND PLUMBING.
COORDINATE ALL CEILING FIXTURES AND EQUIPMENT WITH MECHANICAL AND ELECTRICAL
DRAWINGS PROVIDED WITHIN THESE DOCUMENTS.
THIS PLAN IS INTENDED TO SHOW THE GENERAL CONFIGURATION AND MATERIALS OF THE CEILINGS
ONLY.
CENTER CEILING GRID IN AREAS UNLESS SHOWN OTHERWISE COORDINATE LAYOUT WITH ARCHITECT
PRIOR TO INSTALLATION.
COLOR’S SUBJECT TO CHANGE WITHIN PRODUCT ’S STANDARD COLOR RANGE UNLESS OTHERWISE
NOTED. DURING SUBMITTAL PROVIDE COLOR SAMPLE OF EACH COLOR IN PRODUCTS STANDARD
COLOR RANGE FOR FINAL COLOR DETERMINATION. FINAL APPROVAL FROM ARCHITECT REQUIRED
BEFORE PURCHASE.
REFLECTED CEILING PLAN GENERAL NOTES
ENSEMBLE 163 LEGEND
EXISTING PYRAMIDAL ACOUSTICAL PANELS
RELOCATED PYRAMIDAL ACOUSTICAL PANELS
4'X8' TUNED ABSORBER / DIFFUSER PANELS IN 406
SILVER NETURAL
CUT PORTION OF SUBSTRATE OUT ALLOWING
CONDUIT TO RUN INSIDE PANEL WITH FABRIC
COVERING CONDUIT ADD WOOD SUPPORT IF NEEDED
CUT PANEL AROUND ELECTRICAL BOX ACOUSTICAL WALL PANEL
ACOUSTICAL WALL PANEL EXISTING WALL
1.
2.
3.
4.
5.
6.
NEW 4'X8' TUNED ABSORBER / DIFFUSER PANELS IN 406 SILVER NETURAL WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER MANUFACTURER ’S RECOMMENDATION. PANELS TO
BE PLACED PER ELEVATION. TOUCH UP WALL PAINT IF AFFECTED BY NEW CONSTRUCTION.
NEW MODIFIED 4'X8' / CUSTOM SIZED 4'X6'-9' TUNED ABSORBER / DIFFUSER PANELS, PER
ELEVATION, IN 406 SILVER NETURAL WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER MANUFACTURER’S RECOMMENDATION. PANELS TO BE PLACED PER ELEVATION. TOUCH UP
WALL PAINT IF AFFECTED BY NEW CONSTRUCTION.
EXISTING CLOCK AND SPEAKER, TO REMAIN CUT PANELS AROUND.
PANELS TO BE CUT AROUND CONDUIT AS TIGHTLY AS POSSIBLE, SEE DETAIL 7/A3.60.
RELOCATED PYRAMIDAL ACOUSTICAL PANELS.
REPAIR GRID AND TILE TO MATCH EXISTING ACOUSTICAL CEILING AT REMOVED PYRAMIDAL
ACOUSTICAL PANEL.
ENSEMBLE ROOM 163 KEYNOTES: #
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:5
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
ENSEMBLE ROOM 163
FLOOR AND
REFLECTED CEILING
PLANS
A3.60
CK/JFH
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/4" 1'-0"A3.60
1 ENSEMBLE 163 FLOOR PLAN
1/4" 1'-0"A3.60
2 ENSEMBLE 163 REFLECTED CEILING PLAN
TRUE
NORTH
1/4" 1'-0"A3.60
3 ENSEMBLE 163 EAST ELEVATION
1/4" 1'-0"A3.60
5 ENSEMBLE 163 SOUTH ELEVATION A
1/4" 1'-0"A3.60
6 ENSEMBLE 163 WEST ELEVATION
1/4" 1'-0"A3.60
4 ENSEMBLE 163 SOUTH ELEVATION B
TRUE
NORTH
3" 1'-0"A3.60
7 ABSORPTION PANEL DETAIL
WAVE BAFFLES
TYP.
4' - 0"
TYP.
4' - 0"
TYP.
2' - 4"
TY
P.
2' 0"
TY
P.
2' 0"
TY
P.
2' 0"
TY
P.
2' 0"
2 2 2 2 2 2 2 2 2 22
3 3 3 4
3 3 3 4
3 3 3 4
128' - 2"
126' - 1"
TYP.
4' - 0"
3 3 3 4
3 3 3 4
3 3 3 4
3 3 3 4
3 3 3 4
3 3 3 4
3 3 3 4
3 3 3 4
3 3 3 4
WAVE BAFFLES
122' - 3"
126' - 3"
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
131' - 0"
1.
2.
3.
4.
NEW 4'X8' HARDSIDE ACOUSTICAL WRAPPED PANELS IN 408 BLACK WITH SQUARE EDGE
DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER MANUFACTURER ’S RECOMMENDATION.
PANELS TO BE CENTERED ALONG LENGTH OF WALL TOUCH UP WALL PAINT IF AFFECTED
BY NEW CONSTRUCTION.
NEW 4'X8' AND MODIFIED 4'X8' HARDSIDE ACOUSTICAL WRAPPED PANELS, PER ELEVATION,
408 BLACK WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER
MANUFACTURER’S RECOMMENDATION. CUT PANELS AROUND JOISTS. PANELS TO BE
CENTERED ALONG LENGTH OF WALL. TOUCH UP WALL PAINT IF AFFECTED BY NEW
CONSTRUCTION.
NEW CUSTOM SIZE 2'X4' HARDSIDE ACOUSTICAL WRAPPED PANELS, PER ELEVATION, IN 406
SILVER GRAY WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER
MANUFACTURER’S RECOMMENDATION. MATCHING WINDOW SPACING. TOUCH UP WALL
PAINT IF AFFECTED BY NEW CONSTRUCTION.
NEW CUSTOM SIZE 2'X2'-4" HARDSIDE ACOUSTICAL WRAPPED PANELS, PER ELEVATION, IN
406 SILVER GRAY WITH SQUARE EDGE DIRECTLY APPLIED TO WALL WITH Z-CLIPS, PER
MANUFACTURER’S RECOMMENDATION. MATCHING WINDOW SPACING. TOUCH UP WALL
PAINT IF AFFECTED BY NEW CONSTRUCTION.
GYMNASIUM 180 ELEVATION KEYNOTES: #
GYMNASIUM 180 LEGEND
3'X15' WAVE BAFFLES IN SILVER GRAY
4'X8' HARDSIDE ACOUSTICAL WRAPPED PANELS IN 408 BLACK
2'X4'/2'X2'-4" HARDSIDE ACOUSTICAL WRAPPED PANELS IN 406
SILVER GRAY
1.
2.
CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO COMMENCEMENT OF WORK.
COLOR’S SUBJECT TO CHANGE WITHIN PRODUCT ’S STANDARD COLOR RANGE UNLESS
OTHERWISE NOTED. DURING SUBMITTAL PROVIDE COLOR SAMPLE OF EACH COLOR IN
PRODUCTS STANDARD COLOR RANGE FOR FINAL COLOR DETERMINATION. FINAL
APPROVAL FROM ARCHITECT REQUIRED BEFORE PURCHASE.
ELEVATION GENERAL NOTES
402121
JAMES G.
HOLLOWAY
ST
AT
E O
F COLORADO
L
ICENSED ARCH
IT
EC
T
PROJECT #:
DATE:
DRAWN BY:
CA
SP
ER
, W Y
GR
EE
LE
Y, C O
- S
HE
RI
DA
N, W Y
3/ /2 4:
:5
PM
C :\U se rs \c kl os te rm an \D oc um en ts \2
- G
R
EE
LE
Y C
EN
TR
AL
H S
AC
O U
ST
IC
AL
IM
PR
O
VE
M
EN
TS
(C en tra l N
D riv e) _c kl os te rm an 5Z H D 3.
rv t
GYMNASIUM 180
INTERIOR
ELEVATIONS
A5.20
CK/JFH
W E L D C O U N T Y S C H O O L D
IS
T R
IC
T
4T H A V E N U E
G R E E L E Y , C O
G R E E L E Y C E N T R A L H S A C O U S T
IC
IM
P R O V E M E N T S
03/08/2024
1/4" 1'-0"A5.20
1 GYMNASIUM 180 EAST ELEVATION
1/4" 1'-0"A5.20
2 GYMNASIUM 180 WEST ELEVATION
4' - 0"
126' - 1"
128' - 2"
TY
P.
1' 1/ 8"
TYP.
1' - 10 1/2"
TYP.
2' - 0"
TY
P.
1' 1/ 8"
TYP.
7 5/8"
TYP.
9 1/8"
3' - 4"
130' - 11"
WAV…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .