AEDC
LONG FOCAL LENGTH TELESCOPE
Questions
QUESTION RESPONSE
1.
We would like to know if the end user wants USB or Serial for the focuser electronics connection to the control computer
Either one is sufficient for the Government.
2.
Can you please define the “image circle” requirement more? Is that a diffraction limited or sensor limited specification?
Image circle is the minimum required un-vignetted image due to sensor size.
3.
What is the pixel size of the sensor?
Sensor has a 21mm diagonal.
4.
What is the operational temperature range?
Operating temperatures between 0-35 C
5. Will the Government or Telescope Vendor provide the 5” draw tube?
The Telescope Vendor will provide the draw tube