Kadena AB RFP Questions – 29 May 19
Question 1: Is there a reason why the engineer wants B-Deck & Plywood flooring when the Ball transfer system could be mounted directly to the mezzanine structure?
Answer: The ball transfer conveyor will need to sit above the joists to allow for the fork tine cutouts.
Please comply with the specifications.
Question 2: Also need confirmation of what the 54’ 7” dimension defines – the pdf drawing shows it ending on a nonspecific target - plan south
Answer: Assuming this is referring to the 45’-7” dimension. The drawing and specifications have been corrected – the dimension now extends to the column and measures 47’-7”.