AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
See Block #2
PAGE OF PAGES
2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
4. REQUISITION/PURCHASE REQ.NO.
5. PROJECT NO. (If applicable)
6. ISSUED BY AFLCMC/PZIEB CODE FA8604 7. ADMINISTERED BY (If other than Item 6) CODE
USAF/AFMC/AFLCMC
AF LIFE CYCLE MANAGEMENT CENTER
2275 D STREET, BLDG 16, RM 128
WRIGHT-PATTERSON AFB OH 45433-7228
DANE C. COOPER 9376567470
dane.cooper.1@us.af.mil
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NO.
FA8604-17-R-8061
X
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
CODE FACILITY CODE
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, X is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER.
If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATION OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
(X )
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: ( ) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. ITEM
10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Non-ACAT, MMHS, HDSS at Eielson AFB, AK - Amendment 0001, Revision to Appendix F
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print).
16A. NAME AND TITLE OF SIGNER (Type or print)
DIANE M. CHONG
15B. CONTRACTOR/OFFEROR
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA
16C. DATE SIGNED
(Signature of person authorized to sign)
BY________________________________________
(Signature of Contracting Officer)
NSN 7540-01-152-8070 30-105 STANDARD FORM 30 (REV.10-83)
PREVIOUS EDITION UNUSABLE Prescribed by GSA ConWrite Version 6.15.2 FAR (48 CFR) 53.243 Created 22 May 2017 3:06 PM
SCHEDULE
FA8604-17-R-8061 0001
SECTION A - SOLICITATION FORM:
1. PURPOSE: This solicitation amendment to FA8604-17-R-8061 is issued to revise Attachment #7, Appendix F.
2. SUMMARY OF CHANGES:
a. Section J - Attachments/Exhibits:
1. Attachment 7, Appendix F for a 463L Gravity Roller Conveyor at Eielson AFB, AK, Building
3426, CSN: PEL (REV 1)
All other terms and conditions of this solicitation remain the same.
CONTRACT DOCUMENTS, EXHIBITS AND ATTACHMENTS
FA8604-17-R-8061 0001
DOCUMENT PGS DATE TITLE
ATTACHMENT 7 18 22 MAY 2017 APPENDIX F FOR A 463L GRAVITY ROLLER
CONVEYOR AT EIESON AFB, AK, BUILDING 3426,
CSN: PEL607 (REV 1)
APPENDIX F
FOR
463L GRAVITY ROLLER CONVEYOR SYSTEM
AT
EIELSON AFB ALASKA
DATE: 14 APRIL 2017
REVISION 1: 22 MAY 2017
PREPARED BY:
Andrew J Huser
ANDREW J HUSER
AFLCMC/EZPAE
WRIGHT-PATTERSON AFB OH
FA8604-17-R-8061 Attachment #7 Page 1 of 18
THIS PAGE LEFT BLANK INTENTIONALLY
FA8604-17-R-8061 Attachment #7 Page 2 of 18
Eielson AFB - APP F - Page i
Table of Contents
1. SCOPE
1.1. GENERAL SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
3.1. SYSTEM DESCRIPTION
3.2. PERFORMANCE AND PHYSICAL CHARACTERISTICS
3.2.1. REMOVAL AND DISPOSAL OF EXISTING GRC SYSTEM
3.2.2. GRAVITY ROLLER CONVEYOR
3.2.2.1. LOAD CAPACITY
3.2.2.2. ROLLERS
3.2.2.2.1. ROLLER TUBES
3.2.2.2.2. ROLLER AXLES
3.2.2.2.3. ROLLER BEARINGS
3.2.2.3. ROLLER FRAMES....................................... 3 |R1
3.2.2.3.1. ANCHOR PLATES
3.2.2.4. CROSSTIES
3.2.3. PALLET STOPS
3.2.3.1. REMOVABLE PALLET STOPS
3.2.4. FORKLIFT INTERFACE
3.2.4.1. HARDWOOD/STEEL
3.2.4.2. TINE DEFLECTORS
3.2.5. DEFORMATION UNDER IMPACT
3.2.6. CONVEYOR GUIDE RAILS
3.2.7. ANCHORING AND SHIMS
3.2.8. PALLET TRANSFER
3.2.8.1. INTERFACES
3.2.8.2. CONVEYOR LEVELNESS
3.2.8.3. PALLET TRACKING
3.2.8.4. MANUAL OPERATION
3.2.9. SCALE................................................. 7 |R1
3.2.9.1. DISPLAY............................................. 7 |R1
4. QUALITY ASSURANCE PROVISIONS
4.1. INSPECTIONS
4.2. TESTS
4.3 CERTIFICATIONS
FA8604-17-R-8061 Attachment #7 Page 3 of 18
Eielson AFB - APP F - Page ii
THIS PAGE LEFT BLANK INTENTIONALLY
FA8604-17-R-8061 Attachment #7 Page 4 of 18
Eielson AFB - APP F - Page 1
1. SCOPE
1.1. GENERAL SCOPE
This appendix establishes the minimum performance, design, fabrication, installation, and test requirements for a 463L
Pallet Gravity Roller Conveyor (GRC) system in Building 3246, at
Eielson Air Force Base (AFB), Alaska. The work shall be completed in accordance with this appendix, the cover PD, and
Air Force (AF) Drawing PEL607-01. This appendix covers all equipment, materials, and labor necessary to complete installation of the system.
2. APPLICABLE DOCUMENTS
Applicable documents shall be in accordance with section 2 of the cover PD.
3. REQUIREMENTS
3.1. SYSTEM DESCRIPTION
The GRC system shall be installed and configured as shown on AF
Drawing PEL607-01. The GRC system shall be designed to transfer
463L pallets. The conveyor shall be configured so the 88 inch edge is leading during transfer of the pallets.
3.2. PERFORMANCE AND PHYSICAL CHARACTERISTICS
3.2.1. REMOVAL AND DISPOSAL OF EXISTING GRC SYSTEM
An existing GRC lane, roughly the same length as the requested
GRC lane, shall be removed and disposed of by the Contractor.
The new GRC lane is a replacement of the existing GRC lane.
3.2.2. GRAVITY ROLLER CONVEYOR
The GRC consists of rollers installed in roller frames. A set of rollers installed in frames is a gravity roller section. A gravity roller lane consists of three gravity roller conveyor sections and two side guides, one on each side of the gravity roller sections. The conveyor system shall be used to store and transfer pallets manually on the conveying surface. The system layout and configuration is as shown on AF Drawing PEL607-01.
3.2.2.1. LOAD CAPACITY.
FA8604-17-R-8061 Attachment #7 Page 5 of 18
Eielson AFB - APP F - Page 2
The conveyor system shall store and convey 463L pallets and comfort pallets, with weights ranging from empty to fully loaded, without damage or permanent deformation. The conveyor system shall store and transport conveyor loads weighing 10,500 pounds distributed over a 108-inch by 88-inch area without damage or permanent deformation.
3.2.2.2. ROLLERS
Each roller shall have a minimum load capacity of 550 pounds.
The conveying surface of the rollers shall extend a minimum of
1/4 inch above the frame. The rollers shall be located on maximum 6-inch centers. The rollers shall be easily removable for inspection and maintenance. Rollers shall be designed to have a minimum service life of ten years at a usage rate of
5,000 hours per year based on CEMA 401, using an equivalent radial load which is greater than or equal to 10,500 pounds divided by half of the minimum number of rollers under a pallet
(21 rollers) and a roller surface speed of 40 feet per minute.
3.2.2.2.1. ROLLER TUBES
The roller tubes shall be minimum 2-1/2-inch diameter steel tubing with 7-gauge wall thickness. The tubes shall have no seam or the seam shall be ground flush. All roller tubes shall have electro-deposited zinc coatings. Roller tube plating shall comply with ASTM B633, Service Condition 2, Type I.
3.2.2.2.2. ROLLER AXLES
Axles shall be a minimum 11/16-inch hex cold-rolled steel. All axles shall be of the through type and shall be pin, ring retained or spring-loaded to facilitate easy removal of rollers for cleaning and maintenance.
3.2.2.2.3. ROLLER BEARINGS
Roller bearings shall be the non-precision, dust-tight, light-oil lubricated, zinc-plated, anti-friction ball type. Greased bearings shall not be acceptable. Each bearing shall have a minimum static load rating of 275 pounds. The bearings shall be securely mounted by swaging the roller ends or an equally suitable method approved by the COTR. The bearings shall be shielded or steel labyrinth sealed on both sides. If shielding is used, the shield shall be a solid, rigid material that will not flake or otherwise introduce foreign material into the bearing. Felt shields shall not be acceptable. The roller bearings shall have separate steel inner and outer rings.
FA8604-17-R-8061 Attachment #7 Page 6 of 18
Eielson AFB - APP F - Page 3
3.2.2.3. ROLLER FRAMES |R1
All frames shall be standard 10-foot or 20-ft sections where possible. Roller frames shall be minimum 4-inches high at 6.7
5.4 pounds-per-foot structural steel channel. Frame sections shall be bolted together flush end-to-end with lock washers or self-locking nuts to provide a continuous, level-conveying surface. Axle holes shall be punched in the high position on the channel so the conveying surface is a minimum 1/4-inch above the top of the frame. Axles shall easily slide into and out of the axle hole without binding or interference from the frame.
3.2.2.3.1. ANCHOR PLATES
Frames shall be anchored or attached to the surface below through anchor plates. Anchor plates shall be welded to both frames. The bottom of the anchor plate shall be flush with the bottom of both frames.
3.2.2.4. CROSSTIES
A minimum of four steel crossties shall be positioned in every
10-foot section to provide structural support. Crossties shall be welded to the inside of the roller frames. Crossties shall not interfere with operation of rollers. Crossties shall be equally spaced along a 10-foot length of the frames. Crossties shall not be used to anchor roller sections.
3.2.3. PALLET STOPS
3 removable pallet stops shall be required for the gravity roller conveyor system. All pallet stops shall withstand repeated impacts of pallets weighing up to 10,000 pounds moving at 40 feet per minute. Pallet stops, pallet stop supports, pallet guides, conveyor frames, and pallets shall not exhibit damage, deformation, or decreased performance from such impacts.
Pallet stops shall extend a minimum of 4 inches above the conveying surface. Pallet stops shall be painted safety yellow.
Pallet stops shall not have sharp edges or corners that create a safety hazard.
3.2.3.1. REMOVABLE PALLET STOPS
The removable pallet stop plates shall be constructed as shown on AF Drawing PEL607-01. Removable pallet stop sets shall be provided at each end of the conveyor and at approximate midpoint as shown on AF Drawing PEL607-01. When the removable stops are
FA8604-17-R-8061 Attachment #7 Page 7 of 18
Eielson AFB - APP F - Page 4 removed, there shall be no remaining protrusions that can snag the pallets or interfere with pallet transfer. A hand opening approximately 1 inch high by 4 inches wide shall be punched in removable stops to provide a handle. The top of the hand opening shall be located approximately 1 inch below the top of the stop. The removable stops shall slide between two support angles. Support angles shall be minimum 4-inch by 5-inch by
1/2-inch structural angle steel. Support angles shall be welded to the conveyor frame or anchored. The bottom of the support angle shall be flush with the bottom of the conveyor frame. The support angles shall not interfere with pallet transfer. The removable stops shall easily slide in and out of the support angles without binding or snagging. One person shall be able to remove and replace each removable stop with a maximum force of
30 pounds.
3.2.4. FORKLIFT INTERFACE
A forklift interface shall be provided on each end of the conveyor lane. Forklifts pick up and set down pallets at forklift interfaces. Forklift interfaces shall have hardwood or steel guides and forklift tine deflectors to protect the conveyor.
3.2.4.1. HARDWOOD/STEEL
Treated hardwood or steel reinforcement bar shall be placed in the first 7 feet of the forklift interface as detailed in AF
Drawing PEL607-01. The hardwood or steel reinforcement bar shall protect the frame from forklift tines. Hardwood if used shall be fire retardant and treated to deter termites and moisture. The hardwood or steel reinforcement bar shall be bolted to the frame in at least three places. The bolt heads shall be recessed into the wood or steel. The hardwood or steel reinforcement bar shall be easily removable for repair/replacement. The hardwood or steel reinforcement bar shall not interfere with conveyor operation. The hardwood or steel reinforcement bar shall be painted the same color as the conveyor frame.
3.2.4.2. TINE DEFLECTORS
Tine deflectors shall deflect tines approaching the forklift interface upwards so the impact is not felt by or transferred to the conveyor frame. Tine deflectors shall be as shown in Figure
1. The deflector shall not exhibit damage, deformation, or decreased performance from tine impacts. The tine deflector
FA8604-17-R-8061 Attachment #7 Page 8 of 18
Eielson AFB - APP F - Page 5 shall be minimum 3/8-inch thick steel installed at an angle to deflect approaching tines upward. Tine deflectors shall extend from the top of the conveyor frame to within 1/4 inch of the conveyor-mounting surface. Tine deflectors shall be anchored to the conveyor frame or the same surface as the conveyor frame.
Figure 1
Tine Deflector
3.2.5. DEFORMATION UNDER IMPACT
All conveyor frames, rollers, bearings, roller shafts, and guide rails shall be capable of withstanding repeated impacts from manual pallet transfer, and pallet jack transfer without suffering damage or permanent deformation. Manual pallet transfer impacts shall occur from the manual transfer of pallets on the conveyor. Pallet jack pallet transfer impacts shall occur at pallet jack interfaces when pallets on tines are lowered onto the conveyor.
3.2.6. CONVEYOR GUIDE RAILS
Guide rails shall be minimum 6-inch x 4-inch x 1/2-inch structural angle steel. Guide rails shall be anchored separately from the conveyor frames. Guide rails at forklift interfaces shall flare out at the ends. The final 20 inches of a flared guide rail shall flare out 3 inches or 8.5 degrees.
Each rail section shall be a standard 10-foot section where possible. Guide rail sections shall be mounted flush end to end to prevent snag points. Guide rail sections shall be welded or spliced to provide a continuous, smooth surface. All guide rails shall be painted safety yellow.
3.2.7. ANCHORING AND SHIMS
FA8604-17-R-8061 Attachment #7 Page 9 of 18
Eielson AFB - APP F - Page 6
The GRC shall be anchored to the scale deck plate (Para 3.2.9.)
and associated framing/deckplate to maintain levelness from scale, excluding the pit area as described below and shown in AF
Drawing PEL607-01. The GRC frames and guide rails shall be anchored on maximum five foot centers, with each component being anchored in a minimum of two places. Conveyor frames and guide rails shall be anchored within six inches of each end. As a minimum, the conveyor frames shall be shimmed at each anchor point and at all interface points between conveyor frames to ensure a smooth transition between conveying surfaces. The shims shall be held in place by the anchor bolt. Shim holes shall be punched or drilled. Slotted shims shall not be acceptable. Beveled or half-shims shall be provided where required to provide a level conveying surface. The guide rails need only be shimmed to the point where they extend a minimum of
1-1/2 inches above the conveyor frames along the entire length of the conveyor. Shims shall be equal in width to the width of the component under which it is installed (either the conveyor support or the guide rail) and shall be aligned beneath the component. Each shim shall be a minimum of 4 inches in length.
Shims shall be of sufficient varying thickness so that no more than five shims are installed at any point. There exists a pit at the overhead door which is 100” long x 33” wide x 10-3/4” deep. The Contractor shall design a method such that the conveyor shall be supported and span the 33” pit width such that when the overhead door is open the conveyor can be loaded/unloaded from outside the building. The conveyor shall not deflect or deform when a fully loaded pallet is stored upon or traverses the conveyor. Levelness shall be maintained from the conveyor mounted on the scale and to and through the supported conveyor.
3.2.8. PALLET TRANSFER
3.2.8.1. INTERFACES
Pallets shall not snag or bind at interfaces between conveyor frames and guide rails or across gaps in the conveyor frames and guide rails.
3.2.8.2. CONVEYOR LEVELNESS
The conveying surface shall be level along its entire length and width. The conveying surface of all rollers shall be level to within 1/8 inch over 10 feet measured along the length and width of the conveyor. The conveyor shall provide a smooth surface for transporting palletized loads. The contractor shall verify the existing floor slope and condition prior to conveyor
FA8604-17-R-8061 Attachment #7 Page 10 of 18
Eielson AFB - APP F - Page 7 installation. The Contractor is responsible for providing a level-conveying surface.
3.2.8.3. PALLET TRACKING
Pallet loads shall be able to be pushed down the entire length of the conveyor at approximately 40 feet per minute by two people (when previously centered) without the edge of the pallet touching the guide rail.
3.2.8.4. MANUAL OPERATION
All rollers shall be free rolling and free spinning without binding during all operations. The force required to start and maintain pallet transfer shall not exceed 25 pounds per 1,000 pounds of load. Manual transfer without using tools for leverage shall meet the force requirement. The force shall be applied 48 inches above the conveying surface at the edge of the pallet. The force requirements apply to rollers for pallet transfer perpendicular to the axles.
3.2.9. SCALE |R1
One 15,000 pound capacity scale with an accuracy of at least 0.5 percent of applied load shall be provided as part of the 463L gravity roller conveyor lane. The scale shall be located as shown on AF Drawing PEL607-01. The scale shall have a minimum of four shear beam load cells capable of withstanding repeated impacts of loading and unloading the conveyor. Each load cell shall be NTEP certified, hermetically sealed stainless steel and have a capacity of at least one-half the total scale capacity.
All load cells shall be dust and water tight. The conveyor sections and guardrail shall be attached to the scale deck plate. Height of the scale shall be no more than 4 inches. The front of the scale shall be protected with a deflector plate or ramp to preclude fork time impact.
3.2.9.1. DISPLAY |R1
The scale shall have a separate digital display. The display and associated controls shall be clearly labeled. The display shall show weight, gross, net, and tare. The units for weight measurement and display will be switchable between pounds and kilograms. The display will have characters of height no less than 1/2 inch. The display shall be located as shown on AF
Drawing PEL607-01.
FA8604-17-R-8061 Attachment #7 Page 11 of 18
Eielson AFB - APP F - Page 8
4. QUALITY ASSURANCE PROVISIONS
4.1. INSPECTIONS
The system shall be inspected to verify that it meets all the requirements of sections 1, 2, and 3 of this appendix and the
Cover PD. These inspections shall be completed as part of the system checkout test and again as a part of the quality conformance test.
4.2. TESTS
The following test shall be performed on the system as part of the system checkout test and again as a part of the quality conformance test.
No. Paragraph Description
1. 3.2.3. With a fully loaded 463L pallet, impact all pallet stops at a speed of 40 feet per minute.
Inspect all pallet stops, pallet stop supports, conveyor frames, and pallets for deformation.
If any deformation is present, the pallet stops fail this test.
2. 3.2.4.2. Impact a deflector with a tine at a maximum forklift speed of three miles per hour. Repeat for each deflector. If any deformation, damage, or decreased performance is noted, the deflectors fail this test.
3. 3.2.2.1. Two fully loaded 463L pallets (gross weight of
10,500 pounds each) shall be placed on the gravity roller conveyor for two hours. The loads shall then be removed from the conveyor.
The conveyor will then be inspected for any deformation. Each individual roller will be tested to determine if it is still free rolling.
If any deformation is present or if any rollers are not free rolling, the conveyor fails this test.
4. 3.2.8.2. Test to ensure that the conveyor system is level along its entire length and width providing a smooth surface for transporting loads. Using a level, verify levelness. If the conveyor is not level to within 1/8-inch over 10 feet at all
FA8604-17-R-8061 Attachment #7 Page 12 of 18
Eielson AFB - APP F - Page 9 locations measured, the conveyor fails this test.
5. 3.2.8.3. Test to ensure that the conveyor is true and level and that pallets roll straight. A fully loaded 463L pallet shall be centered on the conveyor. The pallet shall be pushed along the full length of the conveyor. Repeat with an empty 463L pallet. This test shall be repeated until all conveyors have been tested 5 times.
If the pallet touches the guide rail during the test, the conveyor fails this test.
4.3 CERTIFICATIONS
The Contractor shall provide certification that the following requirements have been met. All certifications shall be provided in accordance with the Cover PD.
NO. Paragraph Certifications
1. 3.2.2.2. Each roller has a minimum load capacity of
550 pounds and is designed to have a minimum service life of ten years at a usage rate of
5,000 hours per year based on CEMA 401, using an equivalent radial load which is greater than or equal to 10,500 pounds divided by half of the minimum number of rollers under a
463L pallet (21 rollers) and a roller surface speed of 40 feet per minute.
2. 3.2.2.2.1. Roller tube plating complies with ASTM B633, Service Condition 2, Type I.
3. 3.2.2.2.3. Roller bearings are non-precision, dust-tight, light-oil lubricated, zinc-plated, anti-friction ball type, and have a minimum static load rating of 275 pounds.
FA8604-17-R-8061 Attachment #7 Page 13 of 18
TECHNICAL PROPOSAL QUESTIONNAIRE
FOR
463L GRAVITY ROLLER CONVEYOR
Solicitation Number: FA8604 - -R-
Project Title: High Density Storage System
Base: Eielson AFB AK CSN: PEL607
Appendix F, Gravity Roller Conveyor System, 14 April 2017
The Offeror shall complete this questionnaire. All entries to this questionnaire shall be typed. The questionnaire will be used to determine the Offeror's understanding of the requirements and acceptability of the proposed equipment.
Please attach product literature/cut sheets for all equipment detailed in this questionnaire and attach any exceptions to the
Purchase Description Appendix or recommendations/design alternatives as detailed below.
Gravity Roller Conveyor Manufacturer: ________________________
Paragraph Characteristics
3.1. Will the conveyor store and transfer 463L and
comfort pallets as specified?
YES NO
3.2.2.2. What type of rollers will be provided? __________
What is the minimum load capacity of each roller?
________ Pounds
3.2.2.2. What is the roller spacing, center to center?
_______ inches
What is the minimum distance between the conveying surface of the rollers and the frame? ____ inches
3.2.2.2.1. What is the diameter of the roller tubes?
________ inches
Does the roller tube plating comply with ASTM
B633, Service Condition 2, Type I?
FA8604-17-R-8061 Attachment #7 Page 14 of 18
Eielson AFB - APP F - Page 2 of 5
3.2.2.2.2. What type and size of axles will be provided?
How are roller axles retained? ___________________
3.2.2.2.3. What type of bearings is being provided?
What is the bearing load rating? _______ pounds
3.2.2.3. What size of channel will be used for the frames?
___________ inches at ___________ pounds-per-foot
3.2.2.4. Will crossties be provided as specified?
3.2.3. How many removable pallet stop sets will be
provided? _______
Are all pallet stops designed to withstand impact without damage as specified? YES NO
How far above the conveying surface do pallet stops extend? ______ inches
What is the thickness of pallet stops? _____ inch
3.2.2.1. What is the load capacity of the gravity roller
conveyor? __________ pounds
3.2.8.1. Will pallets transfer between adjacent conveyor
frames without snagging or binding?
3.2.8.2. Will the conveying surface be adjusted to within
1/8 inch of being level over every 10-foot section over the entire conveying surface to compensate for a floor that is not level?
FA8604-17-R-8061 Attachment #7 Page 15 of 18
Eielson AFB - APP F - Page 3 of 5
3.2.5. Will the conveyor withstand repeated impacts from
on/off-loading of pallets and transfer of pallets without suffering permanent deformation?
3.2.6. Are guide rails provided in the locations
specified? YES NO
Are the guide rails structural steel angle?
Size of the guide rails:
______ inches x ______ inches x ______ inch
3.2.6. Are flared sections of guide rail provided in the
locations and configurations specified?
Are guide rail sections mounted flush end to end to prevent snag points? YES NO
3.2.7. Will the conveyors be anchored on maximum 5 feet
centers? YES NO
What will be the minimum number of anchors for each component of the conveyor? _________
3.2.4.2. Are tine deflectors provided where specified?
Do the deflectors deflect tines so the impact is not transferred to the conveyor frame or pallet stop? YES NO
Will the deflectors not be damaged or suffer permanent deformation from tine impacts?
FA8604-17-R-8061 Attachment #7 Page 16 of 18
Eielson AFB - APP F - Page 4 of 5
3.2.9.
3.2.9.1.
Scale manufacturer: _____________________________
Scale Capacity: __________________________ pounds
Height from floor to top of roller? _______ inches
Fork tine deflector/scale guard for scale provided?
Scale Display provided as specified?
FA8604-17-R-8061 Attachment #7 Page 17 of 18
Eielson AFB - APP F - Page 5 of 5
EXCEPTIONS
Attach any exceptions taken to the Purchase Description Appendix.
Please outline those concerns in detail. Your exceptions will be reviewed to determine acceptability.
Are exceptions taken? YES NO
EXCEPTIONS:
FA8604-17-R-8061 Attachment #7 Page 18 of 18