SOW_-_CX50_Upgrade_(complete).docx

DOCX document 29 KB Posted

Attached to
Philips S5-1 Transducers Federal contract opportunity
Solicitation number
FA8601-18-R-0044
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

Attachment 1 Statement of Work

View the file

Other files for this federal contract opportunity

Other files attached to Philips S5-1 Transducers, newest first.
File Type Posted
Sources_Sought_Philips_Transducer.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CX50 Upgrade Phase Array ProbeSTATEMENT OF WORK

21 Feb 2018

1. Introduction: The 88TH Medical Treatment Facility (MTF) located at Wright–Patterson AFB, OH requires two phased array probes for the PHILIPS CX50 ultrasound machine.

2. Background: The pulmonology clinic currently uses conventional monolithic probes which emit a beam in a fixed direction. They must be physically scanned (moved or turned) to sweep the beam through an area of interest. Pulmonary lacks the ability to treat patients with intra-thoracic abnormalities, those in shock and those who are critically ill otherwise without the capabilities of a phased array probe.

3. Delivery Date: 30 days after award.

· Requested delivery dates 14 business days after award

· Base Access Point of Contact SSgt Clarissa Ernst

· Surgical procedure dates – If applicable (surgery)

· Is hand delivery by sales representative requiredY N N/A
· Does sales representative need to be present during surgeryY N N/A

· If yes please provide description of sales rep duties

4. Building address: ATTN: MEMO 4881 Sugar Maple Dr Bldg 830 Area A

WPAFB OH 45433-5529

5. Minimum Requirements: 2 EA – FUS5120 – S5-1 Transducer To include the following:

· CX50 Upgrades for system serial numbers SG91500105 and SG91500093

· Size – Hand held devices

· Design – The probe models must be FUS5120 – S5-1 to fit the port connector of the ultrasound machine.

· Performance Requirements – The probes must create a wide image from a small window by sending out ultrasound waves in an area of interest through proper depth. The probe shall provide physicians adequate visualization of pleural space for definitive patient diagnostics and therapeutic prognosis.

· Accessories – N/A

· Configuration – No configuration is required.

· Installation & Testing – No installation & testing is required.

· Training – No training is required.

· Warranty – 90 day product warranty

· Standards, guidelines or approvals – N/A image1.png

File details come from the government source that posted it.