Contractor Question: Is this tank for penetrant application? If not, what is the tank used for?
Government Response: This RFQ is for a fluorescent penetrant inspection system
Contractor Question: Is it a tank only design, or does the customer want a power immersion system inside the tank to raise and lower the parts inside the tank?
Government Response: This RFQ is for a complete standard PT-48 system IAW CID A-A-58050A.
Contractor Question: Are there an specific documentation requirements? If so, what are they?
Government Response: This RFQ is to include the manufacturers standard commercial documentation provided with the unit. Electronic copy included with the quote.
Contractor Question: The dimensions of the tank are provided, but does the customer want only one tank quoted, or an entire system? It looks like they want one tank quoted, with the possibility of ordering up to a quantity of 4. Please confirm the quantity to quote.
Government Response: This RFQ is for a complete standard CID A-A-58050A, size PT-48 penetrant system. The CID is an attachment to the solicitation posted on FBO. Basic qty is 1 ea, with four option years of 1-4 ea as stated in the solicitation.