RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

5996015989071FD

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Faulkner, Valerie M / 801-777-7475

6. EQUIPMENT SPEC / PHONE

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

X STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

Gardner, Austin BNAME: 14 MAR 2013DATE:

Part Number: JTE133685-1 Noun: AMPLIFIER, ELECTRONIC

ESD: No

SPI: No

"In accordance with FAR 46.2 Contract Quality Requirements, it has been determined by the Technical Authority that the item to be procured under this acquisition must meet critical technical/performance requirements and therefore inspection at the contractor's facility, per FAR 52.246-2 Standard Inspection, is necessary."

Block 3. This item meets all three criteria for inspection at the Source.

Block 4. This item meets the criteria for acceptance at the Source.

Note: It is not feasible to inspect/accept these items at the destination. The RTS-SPO does not have the proper test equipment at this location, if the packaging of this item is disturbed/opened in any way, these items will have to be re-packed.

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

X YES X NEW SOURCE

PREVIOUS SOURCENO

X AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

C

11. SIGNATURE OF TECHNICAL AUTHORITY

Dye, Eric R

ORGANIZATION / SYMBOL

415 SCMS / GUEA

PHONE

801-586-2199 / 586-2199

DATE

02 OCT 2014

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 12 Dec 2018