Performance-Based Work Statement (PWS)
SERVICE REPAIR OF DRUCK ADTS 410 UNIT(S)
U.S AIR FORCE
524 EMXS/MXDPAE
2/21/2018
SERVICE REPAIR OF DRUCK ADTS 410 UNIT(S)
i
TABLE OF CONTENTS
| 1 | DESCRIPTION OF SERVICES | 1 |
| 2 | BASIC SERVICES | 1 |
| 2.1 | REPAIR ESTIMATE | 1 |
| 2.2 | REPAIR SERVICE VERIFICATION | 1 |
| 3 | SERVICES SUMMARY | 2 |
| 4 | GENERAL INFORMATION | 2 |
| 4.1 | SHIPPING INFORMATION | 2 |
| 4.2 | GOVERNMENT PROPERTY | 3 |
| 4.3 | WARRANTY OF SERVICES | 3 |
| 4.4 | ENVIRONMENTAL CONTROLS | 3 |
| 5 | APPENDICES | 3 |
| Appendix A – ACRONYMS AND ABBREVIATIONS | 4 | |
| Appendix B – EQUIPMENT LIST | 5 | |
DESCRIPTION OF SERVICES
This Performance Work Statement (PWS) identifies requirements of the contractor to provide all management, tools, supplies, equipment, materials, and labor required to repair DRUCK Air Data Test Systems (ADTS), model ADTS 401.
BASIC SERVICES
The contractor shall provide major and minor service repair for the DRUCK ADTS 401. The maximum period of performance for any repair is six (6) weeks. The Government will provide the contractor a malfunction report with each unit provided to the contractor for repair. The contractor shall return the units to fully functional operation per the Original Equipment Manufacturers (OEM) specifications and requirements contained in Operators Manual K279 page 5-7 for the Pressure Leak Check and page 5-8 for the Vacuum Leak Check.
REPAIR ESTIMATE
The contractor shall evaluate all DRUCK ADTS 401 units sent to them for repair, categorize the required repair service as major or minor and provide the Government with a cost estimate. The contractor shall not take further action until the repair services and costs are approved by the authorized caller.
MINOR REPAIR SERVICE
The following list of repairs are considered minor: O-rings, washers, seals, gasket or fuses replacement, small leaks and unit not holding pressure.
MAJOR REPAIR SERVICE
The following list of repairs are considered major: All valve replacement, all hardware (casing) replacements, vacuum or pressure pump replacements, front panel replacements, sensor replacements, main PCB board replacements and manifold replacements.
REPAIR SERVICE VERIFICATION
The contractor shall ensure units will at a minimum pass a function test to include: self-test, leak test and calibration check In Accordance With (IAW) the DRUCKS Operators Manual K279 (Pressure Leak Check pages 5-7, Vacuum Leak Check pages 5-8). (CDRL A001)
The finalized calibration certification will be performed by Government Precision Measurement Equipment Laboratory (PMEL).
Units received by the Government that fail self-test, leak test or calibration check will be returned for repair at the contractor’s expense.
SERVICES SUMMARY
| Performance Objective |
| Reference |
| Performance Threshold |
| Evaluation and Estimate |
| 2.1 |
| (95%) The Contractor shall evaluate units requiring repair, categorize the needed repair as major or minor, and provide an estimated repair cost to the authorized caller. |
| Service Repair of DRUCK ADTS 401 unit(s) |
| 2.2 |
| (95%) The Contractor shall ensure all repaired DRUCK units shall be fully functional and pass: self-test, leak test and calibration check IAW the DRUCKS Operators Manual K279 (Pressure Leak Check pages 5-7, Vacuum Leak Check pages 5-8). (CDRL A001) |
GENERAL INFORMATION
SHIPPING INFORMATION
The Government will provide shipping of the units(s) requiring repair to the contract facility, where services will be performed.
Following completion of repairs or the determination by the Government not to complete repairs, the contractor shall ship units to the shipping address below:
524 EMXS/MXDPAE
7274 Wardleigh Rd.
Bldg. 5 Bay C Hill AFB, UT 84056-5137
GOVERNMENT PROPERTY
All Government property provided under this agreement will be provided for repair, maintenance, or overhaul purposes only. The contractor is required to furnish all other property necessary to perform the repair, maintenance, and overhaul services.
The contractor shall be responsible for safeguarding all Government property provided to the contractor.
WARRANTY OF SERVICES
The contractor shall provide a standard commercial warranty on all repaired DRUCK ADTS 401 units.
ENVIRONMENTAL CONTROLS
Compliance with Laws and Regulations. The contractor shall be knowledgeable of and comply with all applicable Interstate, Federal, State and Local laws, regulations and requirements regarding environmental protection. In the event environmental laws or regulations change during the term of this contract, the contractor is required to comply as such law or regulation becomes effective.
APPENDICES
| Appendix A | Acronyms and Abbreviations List |
| Appendix B | Equipment Listing |
Appendix A – ACRONYMS AND ABBREVIATIONS
| ADTS |
| Air Data Test System |
| CDRL |
| Contract Data Requirements List |
| EMXS |
| Electronics Maintenance Squadron |
| GFP |
| Government Furnished Property |
| OEM |
| Original Equipment Manufacturer |
| PMEL |
| Precision Measurement Equipment Laboratory |
| PWS |
| Performance Work Statement |
Appendix B – EQUIPMENT LIST
| Nomenclature |
| Part # |
| Test Set # |
| Air Data Test System |
| ADTS401 |
| 57028 |
| Air Data Test System |
| ADTS401 |
| 0478 |
| Air Data Test System |
| ADTS401 |
| 0479 |
| Air Data Test System |
| ADTS401 |
| 0480 |
| Air Data Test System |
| ADTS401 |
| 54882 |
| Air Data Test System |
| ADTS401 |
| 548883 |
| Air Data Test System |
| ADTS401 |
| 54994 |
| Air Data Test System |
| ADTS401 |
| 54996 |
| Air Data Test System |
| ADTS401 |
| 549997 |
| Air Data Test System |
| ADTS401 |
| 55964 |
| Air Data Test System |
| ADTS401 |
| 55965 |
| Air Data Test System |
| ADTS401 |
| 55995 |
| Air Data Test System |
| ADTS401 |
| 55996 |
| Air Data Test System |
| ADTS401 |
| 56045 |
| Air Data Test System |
| ADTS401 |
| 56046 |
| Air Data Test System |
| ADTS401 |
| 56256 |
| Air Data Test System |
| ADTS401 |
| 56257 |
| Air Data Test System |
| ADTS401 |
| 56258 |
| Air Data Test System |
| ADTS401 |
| 56678 |
| Air Data Test System |
| ADTS401 |
| 56679 |
| Air Data Test System |
| ADTS401 |
| 56794 |
| Air Data Test System |
| ADTS401 |
| 57026 |
| Air Data Test System |
| ADTS401 |
| 57027 |
| Air Data Test System |
| ADTS401 |
| 57312 |
| Air Data Test System |
| ADTS401 |
| 57313 |
| Air Data Test System |
| ADTS401 |
| 57360 |
| Air Data Test System |
| ADTS401 |
| 57459 |
| Air Data Test System |
| ADTS401 |
| 57460 |
| Air Data Test System |
| ADTS401 |
| 57461 |
| Air Data Test System |
| ADTS401 |
| 58427 |
| Air Data Test System |
| ADTS401 |
| 58428 |
| Air Data Test System |
| ADTS401 |
| 58621 |
| Air Data Test System |
| ADTS401 |
| 59263 |
| Air Data Test System |
| ADTS401 |
| 59264 |
| Air Data Test System |
| ADTS401 |
| 59265 |
| Air Data Test System |
| ADTS401 |
| 57028 |
| Air Data Test System |
| ADTS401 |
| 59708 |
| Air Data Test System |
| ADTS401 |
| 59709 |
| Air Data Test System |
| ADTS401 |
| 64656 |
| Air Data Test System |
| ADTS401 |
| 64657 |
image1.jpeg