09128-Salient_Characteristics_for_PATS-70A_Ametek.docx
DOCX document 29 KB Posted
- Attached to
- Auxiliary Power and Load unit Federal contract opportunity
- Solicitation number
- FA8224-18-Q-5968
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 09128_Equipment_List_Delivery_Schedule.xlsx | XLSX spreadsheet | |
| Solicitation__Final.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics for PATS-70A Ametek Programmable Power Brand Name or Equivalent Items The following brand name or equivalent items are to be procured for the PATS-70A production effort:
| MANUFACTURER P/N |
| MANUFACTURER |
| DESCRIPTION |
| QTY |
| 5702478-01 |
| Ametek Programmable Power or Equivalent |
| Auxiliary Power and Load Unit |
| 32 |
The vendor item in the table above have been integrated together into a system which is environmentally qualified by testing to meet the MIL-PRF-28800F, Class 1 and Class 2. This system has also been Electro-Magnet Interference (EMI) qualified by testing to meet MIL-STD-461E. Any equivalent items submitted will need to be integrated into the system and have met these same criteria or standards of testing.
Auxiliary Power and Load Unit Salient Characteristics The salient characteristics for software, hardware and construction of the Auxiliary Power and Load Unit are:
· Software Specifications:
· Extensive software development and integration has been completed and developmentally and operationally tested. The qualifying vendor item must be able to load and run the following firmware for each of the subsystems because of the software Application Programming Interface (API) calls being initiated.
· Controller Firmware P/N: 438405-28 V3.000.018
· AC Power Supply Firmware P/N: 4380496-13 V3.500.018
· DC Power Supply Firmware P/N: 4380407-21 V3.000.17
· Load Module Firmware P/N: 4380456-09 V3.000.008
· General Requirements
| · Case Dimensions: | 19” (W) x 25” (L) x 15” (H) (Without Case Accessories) |
| · Weight: | 190 Lbs. Max |
| · Case Accessories: | Pull-out handle, and castors |
| · Input Power: | 85-132VAC, 1 Phase, 47-420Hz, 25A |
· Mainframe Requirements:
| · Chassis: | 2 ea., compliant with LXI back plane specifications and chassis parallel interconnect configuration |
| · Available Slots: | 12-slots/chassis |
| · Data Control/Interface: | Ethernet |
· Output Power Requirements:
· AC Power Requirements:
· Programmable
| · Output Power: | 875VA |
| · Phase: | Single to three phase controllable |
| · Output Voltage: | 0-140VAC (low range), 0-280VDC (high range) |
| · Output Current: | 10A max (low range), 5A max (high range) |
| · Output Frequency: | 45-1200 Hz |
| · Efficiency: | 72% or greater |
| · Voltage Distortion: | < 1% (to 500Hz), < 2% (500-1200Hz) |
· DC High Power Requirements:
· Programmable
| · Output Power: | 990W |
| · Output Voltage: | 0-33VDC |
| · Output Current: | 0-30A |
| · Efficiency: | 80% or greater |
| · Ripple and Noise: | 15mV RMS / 60mV p-p |
· DC Low Power Requirements:
· Programmable
| · Output Power: | 330W |
| · Output Voltage: | 0-65VDC |
| · Output Current: | 0-5.1A |
| · Efficiency: | 80% or greater |
| · Ripple and Noise: | 6mV RMS / 60mV p-p |
· Front Panel Fan DC Power Supply
· Programmable
| · Output Power: | 330W |
| · Output Voltage: | 0-16 VDC |
| · Output Current: | 0-20.6A |
| · Efficiency: | 80% or greater |
| · Ripple and Noise: | 5mV RMS / 25mV p-p |
· Input Power Loading Requirements:
· AC/DC Load Modules 2 ea
· Programmable
| · Output Power: | 750W |
| · Output Voltage: | 500V |
| · Output Current: | 30A |
| · Operating Modes: | Constant Current or Constant Resistance |
| · Ripple and Noise: | 90mA p-p |
· Power Routing/Distribution Requirements:
· Power Routing/Distribution Modules 3ea
· Modules shall provide high current to low current electrical current transition for the high power DC Supply and the two AC/DC Load Modules
· AUX Panel Connectors:
| Panel Connector |
| Panel Nomenclature |
| Available Interfaces |
| J1 |
| System Interconnect |
| PATS-70A to Auxiliary Power Interface |
| J2 |
| Input Power |
| Input Power Filter |
· Environmental Requirements:
| Environment |
| Specification |
| Requirements |
| Temperature, Not Operating |
| MIL-PRF-28800F, Class 2 |
| -40 to 71 °C (-40 to 158 °F) |
| Temperature, Operating |
| MIL-PRF-28800F, Class 2 |
| -10 to 55 °C (14 to 131 °F) |
| Relative Humidity |
| MIL-PRF-28800F, Class 2 |
| 5 to 95 ± 5 Percent in the temperature range of 10 to 30 °C (50 to 86 °F) |
5 to 85 ± 5 percent in the temperature range of 30 to 40 °C (86 to 104 °F) 5 to 60 ± 5 percent in the temperature range above 40 °C(104 °F)
| Altitude, Not Operating |
| MIL-PRF-28800F, Class 2 |
| 4600 meters (15, 091 feet) |
| Altitude, Operating |
| MIL-PRF-28800F, Class 2 |
| 3000 meters (9,843 feet) |
| Vibration |
| MIL-PRF-28800F, Class 2 |
| Random 0.03 g^2/Hz @ 10-500 Hz |
| Mechanical Shock (Functional Shock) |
| MIL-PRF-28800F, Class 2 |
| Pulse shall be 11 ms, peak shock value shall be 30 gs. Three shocks in each direction and on each axis for a total of 18 shocks |
| Transit Drop |
| MIL-PRF-28800F, Class 2 |
| 10 drops from 30 cm (11.81 in) drop height |
| Splash Proof |
| MIL-PRF-28800F, Class 2 using: MIL-STD-810 |
| Splashproof test, Class 1. With the cover off and the instrument operating, perform the splashproof test and the Water Repellent Tests for a minimum of 5 minutes. Perform the satisfactory operation tests. |
| Drip Proof |
| MIL-PRF-28800F, Class 2 |
| With the cover off and the instrument operating |
| Dust Resistance |
| MIL-PRF-28800F, Class 1 |
| With the cover off and the instrument operating |
| Solar Radiation |
| MIL-PRF-28800F, Class 2 |
| Continuous 24-hour cycles, 3 cycles, 30 to 43 degrees C and 0 to 1120 W/m^2 |
| Electromagnetic Interference |
| MIL-STD-461 E |
| CE102, CA101, CS114, CS115, CS116, RE102, and RS103 |
Crush Resistance
1,000 pound load
| Explosive Atmosphere |
| MIL-PRF-28800F, Class 2 |
| Power Cycle while in air/gas mixture verify no ignition |
File details come from the government source that posted it.