SITT_INDUSTRY_DAY_BRIEFING.pptx

PPTX presentation 4 MB Posted

Attached to
Shock Isolator Test Stand Federal contract opportunity
Solicitation number
FA8224-16-R-0026
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

SITT Industry Day Briefing

View the file

Other files for this federal contract opportunity

Other files attached to Shock Isolator Test Stand, newest first.
File Type Posted
SITT_DESIGN_CONCEPT_-_INDUSTRY_DAY.docx DOCX document
SD-SITT_Specification_Approved_12-1-15.pdf PDF
Shock_Isolator_Test_Purchase_Request.docx DOCX document
Shock_Isolator_Test_Purchase_Request.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Built Right, Ready to Fight Shock Isolator Test Tower (SITT)

Industry Day 16-17 February 2016

Ogden Air Logistics Complex

O G D E N A I R L O G I S T I C S COMPLEX

Introductions Built Right, Ready to Fight Contracting Officer: David Bryan, 801-586-7779 Lead Process Engineer: Savanna Stepp, 801-777-4659 Process Engineer: Clair Condie, 801-586-9791 Facilities Engineer: Cary Haws, 801-775-3470

CONTRACTORS:

Sytronics, Inc.Renmark-Pacific
X-Technologies, Inc.Major Tool & Machine
Arbor Controls & Testing, Inc.Consolidated Technical Services
Setpoint Systems, Inc.Merrick Co.

Industry Day Agenda Built Right, Ready to Fight

TUESDAY - 16 FEBRUARY

Welcome and Introductions 0930 -1030 – Initial Presentation (AF Museum) 1030-1200 – Tour of Building 1913 SITT & Shock Isolators 1200-1230 – Tour of Building 850 1230-1300 – Lunch

One-on-One Meetings with Contractors (AF Museum)

1300-1345 – Sytronics, Inc.

1400-1445 – Renmark-Pacific 1500-1545 – X-Technologies 1600 – Adjourn for the day

Industry Day Agenda

WEDNESDAY – 17 FEBRUARY

One-on-One Meetings with Contractors (AF Museum)

0930-1015 – Major Tool & Machine 1030-1115 – Arbor Controls & Testing, Inc.

1130-1200 – Lunch 1200-1245 – Consolidated Technical Services 1300-1345 – Setpoint Systems, Inc.

1400-1445 – Merrick Co.

1500 – Conclude Industry Day

PURPOSE OF ACQUISITION

REPLACE AN AGING & OBSOLETE SITT

PROCURE 2 EACH, REDESIGNED SITTs THAT WILL BE DESIGNED TO:

BE SAFER TO OPERATE

BE MORE EFFICIENT TO USE

PROVIDE MORE CONSISTENT TESTING OF SHOCK ISOLATORS

AUTOMATICALLY CONTROL PREPROGRAMMED TESTS, INCLUDING DATA ACQUISITION

KEEP UP WITH INCREASING WORKLOAD

SITT PURPOSE-FUNCTION

TEST THE OPERATING PARAMETERS OF 3 SIs

MISSILE SUSPENSION SYSTEM (MSS)

LIQUID SPRING – USES COMPRESSIBLE FLUID WITH STEPPED PISTON DIAMETER TO CREATE RETRACT FORCE

LAUNCH EQUIPMENT ROOM (LER)

LIQUID SPRING– USES COMPRESSIBLE FLUID WITH STEPPED PISTON DIAMETER TO CREATE RETRACT FORCE

LAUNCH CONTROL CENTER (LCC)

PNEUMATIC with MECHANICAL SPRING – USES CHECK & RELIEF VALVES BETWEEN OUTER TANK & INNER CYLINDER

SHOCK ISOLATORS

MSS SI TESTS

SPRING RATE & FRICTION TEST

EXTEND & RETRACT THE PISTON

DAMPING/ DROP TEST

DROP 41,000 # WEIGHT SLUG – EXTEND PISTON FROM FULL RETRACT TO FULL EXTEND

REQUIRED DATA ACQUISITION

FORCE VS. PISTON DISPLACEMENT DURING BOTH TESTS

- MSS -

SPRING RATE & FRICTION TEST

- MSS -

DAMPING/DROP TEST

LER SI TESTS

SPRING RATE & FRICTION TEST

EXTEND & RETRACT THE PISTON

REQUIRED DATA ACQUISITION

FORCE VS. PISTON DISPLACEMENT DURING THE TEST

- LER –

SPRING RATE TEST

LCC SI TESTS

EQUALIBRIUM TEST

WITH 19,000 # HANGING ON SI - TEST SI MOVEMENT WITH RESPECT TO CHANGING CYLINDER PRESSURE

DIFFERENTIAL TEST

WITH 19,000 # HANGING ON SI -TEST RESPONSE OF TANK PRESSURE TO CHANGING CYLINDER PRESSURE

DROP TEST

DROP 19,000 # WEIGHT SLUG – EXTEND PISTON FROM FULL RETRACT TO FULL EXTEND – USE 2” DROP LINK

REQUIRED DATA ACQUISITION

MEASURE PISTON DISPLACEMENT AND CYLINDER PRESSURE DURING ALL TESTS

- LCC –

DROP TEST DATA

EXISTING SITT

LOADING LCC

SOME KEY DESIGN

POINTS & CHALLENGES

LOAD-UNLOAD SI FROM CARTS @ FLOOR LEVEL WITHOUT USING AUXILIARY LIFTING EQUIPMENT

OPERATOR SAFETY – KEEP WORK AS CLOSE TO FLOOR LEVEL AS POSSIBLE

INSTANT RELEASE OF WEIGHT SLUGS DURING MSS & LCC DROP TESTS – TYPE OF MECHANISM?

DESIGNED FOR ALL 3 SI CONFIGURATIONS AND SHORT CONVERSION TIME

POTENTIAL

DESIGN CONCEPT

A potential design concept has been prepared to stimulate ideas for the replacement SITT. It will be distributed at the end of the facility tour to any contractor that desires it.

Contractors are under no obligation to use the potential design concept. Any contractor who uses any portion of it in their proposal and/or final design shall be fully responsible for the integrity of that design.

Contractors are encouraged to use modern technology and innovative ideas to provide a SITT that will meet the given requirements.

QUESTIONS ?

David Bryan (Contracting Officer) will now provide direction as to how questions will be addressed during the Industry Day.

Thank you for your time and interest in the Shock Isolator Test Tower project image3.jpeg image7.png image8.png image9.png image10.png image11.png image12.jpeg image14.emf image15.emf image13.jpg image16.jpg image17.jpg image18.jpg image19.png image1.png image2.png image4.png image5.png image6.emf