Attachment 1

FA557018Q0008

Requirements Document 422 SFS Shoothouse

Inflatable Wall Company Shoot House RAF Croughton United Kingdom

1. Door Section including hinges

A one-piece door section that provides entrance and access routes into and between rooms.

Using the multiple connection locations doors which can be placed at any location within a room. Additionally, it must be resistant to all training ammunition.

2. Door Insert including hinges and door

A door that easily fits into a door section to close any open doorway. Provides an excellent cover from view, enhancing the realism of any training scenario. The door must be able to swing in either direction e.g. a push or pull door. Also, if pushed too hard (dynamic entry) will eject off the door insert hinge pins, providing a highly realistic scenario. Additionally, it must be resistant to all training ammunition.

3. Window Section

A one-piece window section that provides alternative entrance and access route into and between rooms. Additionally, it must be resistant to all training ammunition.

4. High Wall Section

A one-piece high wall section that is a solid full height/full length wall. Configurable to create a room of any size when placed in any location of the building. Additionally, it must be resistant to all training ammunition and heat from the weapon system.

5. Half Vertical Wall Section

A one-piece half vertical wall section that is full height (7.5 feet) and half-length (4.875 feet) solid wall. Configurable to create a room of any size when placed in any location of the building.

Additionally, it must be resistant to all training ammunition.

6. Half Horizontal Wall Section

A one-piece half horizontal wall section is half-height (3.75 feet) and full length (9.75 feet) solid wall. Configurable to create a room of any size when placed in any location of the building.

Additionally, it must be resistant to all training ammunition.

7. Carrying Bag

Carry bags to store and transport inflatable shoot house pieces. The bags must be sturdy to store shoothouse pieces.

8. Anchor Weight

Steel, 300 millimeter, seven kilogram anchor weights which will be used to increase stability and robustness of the training wall system on any terrain.

9. Air blower

Professional-grade, gas operated, air blower which can quickly inflate the inflatable walls.

10. Pressure gauge

Commercial off the shelf pressure gauge which will allow a user to check pressure inside the walls.

11. Field repair kit

A field repair kit with items specifically for repairs of the inflatable wall system components.

The repair kit must allow users to make quick repairs of the system components while on the field.

12. Door section – skin only

Additional replacement skins for the door section, must fit door section, heat, cold, and humidity resistant.

13. Window section – skin only

Additional replacement skin for the window section, must fit window section, heat, cold, and humidity resistant.

14. High wall section – skin only

Additional replacement skin for the high wall section, must fit high wall section, heat, cold, and humidity resistant.

15. Half vertical wall – skin only

Additional replacement skin for the half vertical wall, must fit half vertical wall, heat, cold, and humidity resistant.

16. Roof sheet

The roof sheet must be 3x4 m, can be applied to a number of different shapes and size rooms to provide enclosure. The intent is to create low light areas inside the inflatable wall building.

The color of the shoot house and its components can be brick, black, gray, or brown.