FA527020Q0051
Issued by
Department of the Air Force Pacific Air Forces

About this file

This amendment modifies a solicitation issued by the Department of the Air Force Pacific Air Forces for a hydraulic test stand and chiller. The amendment revises the national stock number for the hydraulic test stand and adds a contract line item number for the chiller. Offerors must acknowledge receipt of this amendment by the time and date specified in the solicitation. The amendment provides specifications for the required hydraulic test stand and chiller, including dimensions for the test stand, display and control panel requirements, hydraulic system details, electrical power needs, and specifications for an accompanying water chiller system to connect to the test stand.

View the file

Other files for this federal contract opportunity

Other files attached to Hydraulic Test Stand and Chiller, newest first.
File Type Posted
Solicitation - FA527020Q0051.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

16C. DATE SIGNED

Previous edition unusable STANDARD FORM 30 (REV. 11/2016) Prescribed by GSA FAR (48 CFR) 53.243

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBE

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

Supplies or Services & Prices or Costs

The following CLIN(s) / SLIN(s) were added:

INFORMATION VALUE

Description Shipping Product/Service Real Property Quantity 1.0 Unit of Measure Job Option No

The following CLIN(s) / SLIN(s) were modified:

0001 - Hydraulic Test Stand

NSN# 4920-01-680-9279

See Specification

INFORMATION FROM TO

Description

Hydraulic Test Stand and Chiller

NSN 4920-01-579-8823

See Specification

Hydraulic Test Stand

NSN# 4920-01-680-9279

See Specification

0002 - Chiller

NSN # 4130-01-681-9525

See specification

INFORMATION FROM TO

Description Shipping Chiller

NSN # 4130-01-681-9525

See specification

Unit of Measure Job Each

Specification/SOW/SOO/ORD

Miscellaneous text in this section has been modified to:

Test Stand Requirements

Dimensions Max height 8 ft Max width 14 ft Max depth 9 ft General Display for Temperature, PSI and Flow Rate.

Manual Control Panels Hydraulic reservoir 55 Gallon with Fluid Level Indication.

FA527020Q00510001

Blast Shielded/Crash Box Test Area Steel Tubing, Fittings, and Manifolds with internal control.

Cooling System (Required) High Pressure Systems Require 4 High Pressure Hydraulic Ports (Dynamic Pressure/Return) o Two independent circuits of fluid flow.

o Require Range of 0-5,000 PSI Variable Volume Pumps 50 GPM @ 5,000 PSI and 40 GPM @ 6,000 PSI o Utilizes a Cycling Valve for Changes in Fluid Direction.

Requires System Filters and guidance for routine maintenance.

Low Pressure System Low Pressure Hydraulic Port o Variable Volume Pump Up to 10 GPM & 250 PSI o Flow Meter Reading between 0-15 GPM Hydrostatic Pressure System Hydrostatic Port(s) (Static Pressure) o Requires Range of 0-10,000 PSI Pneumatic Circuit Gaseous Nitrogen Pressure 0-6,000PSI Electrical Power AC Power Supply: 5,000 VAC o Adjustable DC Power Supply: 3,000 VAC o Adjustable Power Outlet o 120 VAC 400 HZ Outlet o 0-50 VDC Outlet

Accompanied Equipment (Required) Water Chiller (Water-Oil Cooling System/Hydraulic Fluid Cooling System(HFCS))

Chiller System

Require chiller system to provide chilled fluid to test stand to avoid overheating o Two independent refrigeration circuits o Hydraulic Fluid Rate - 40 GPM Max hydraulic flow pressure - 250 PSI o Cooling Capacity - 100K - 300K BTU/HR o Refrigeration Charge - HFC-410A Refrigerant included. Fully charged on delivery o Circuit breaker-high fault rated control panel o Enclosure type UL 1995 rated for outdoor applications o Water strainer - factory installed to avoid contamination o 2" PVC pipe connections for easy connection to hydraulic test stand LAN System Chiller connected to test stand via LAN cable o Allows test stand to communicate with chiller system o Chiller will automatically start with operation of test stand o Allows for quick diagnostic system check Electrical System Circuit Breaker o 460V, 3 Phase o 60 HZ & 200 AMPS

IDCode:
Page: 1
Pages: 4
AmendNo: 0001
EffDate: 8/7/2020
ReqNo: A008088
ProjNo:
IssCode: FA5270
AdmCode:
IssuedBy: FA5270 18 CONS LGC

APO AP 96368-5199

UNIT 5199

APO, AP 96368-5199

United States Kinoto Nakao, Email: kinoto.nakao.jp@us.af.mil Telephone: 011.81.98.961.1066

AdminBy:
ContractorNameAdd:
Code:
FacCode:
SolChg: 1
SolNo: FA527020Q0051
SolDate: 8/3/2020
AwardChg:
AwardNo:
AwardDate:
Amended: 1
OffrExt:
OffrNoEx: 1
NoCopies: 1
ApprData: See Section G
ChgeOrd:
ChgeOrder:
Modify:
SuppAgre:
SuppAuth:
ModOthr:
OthrSpec:
NoReq: 1
Require:
Copies:
Descript: This Amendment was issued to change the following;

- Revise NSN for the Hydraulic Test Strand from NSN 4920-01-579-8823 to NSN 4920-01-680-9279

- Add CLIN for the chiller

ContNameTitle:
CoNameTitle: Ken Kuresaki

Email: ken.kuresaki.jp@us.af.mil Telephone: 011.81.98.961.0022