Att 1 - Portable Stage Salient Characteristics.pdf

PDF 125 KB Posted

Attached to
15th Wing Mobile Stage Equipment Federal contract opportunity
Solicitation number
FA521523R0005
Issued by
Department of the Air Force Pacific Air Forces

About this file

This document outlines salient characteristics for a portable stage to be procured by the 15th Wing of the Department of the Air Force Pacific Air Forces. Key requirements for the stage include dimensions between 20-24 feet wide by 16 feet deep with an adjustable height between 2-4 feet. The stage must support a weight of at least 2,500 pounds, be weatherproof to withstand various environmental conditions, and be transportable in a government vehicle. Additional specifications include having multiple platforms that fit in a vehicle for transport, carts for moving components, and two sets of stairs on each side with railings and non-slip treads. The stage must be capable of assembly and disassembly by two people within three business days of delivery and match given color requirements. This correlates with federal contract opportunity number FA521523R0005 seeking a mobile stage meeting the outlined salient characteristics for the 15th Wing.

View the file

Other files for this federal contract opportunity

Other files attached to 15th Wing Mobile Stage Equipment, newest first.
File Type Posted
Att 1 - Portable Stage Salient Characteristics v2.pdf PDF
Att 2 - Provisions and Clauses.pdf PDF
Combo Synopsis - 15th Wing Mobile Stage.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics for Portable Stage

Rationale of Requirement 15 WG/Protocol requires a stage for various Ceremonies that occur for different Air Force Units across Hickam. The stage needs to be portable and weatherproof for a variety of different environments and situations where it will be utilized and stored. For setup and breakdown, the stage must be assembled and disassembled by a minimum of two people. With the current stage, it requires a minimum of 10 people to assemble and disassemble, which requires more coordination and manpower.

Portable Stage Requirements The requirements for the stage are below. The vendor must meet or exceed these salient functional and physical requirements, as the current and previous stages would need repairs and labor to maintain or completely replace due to the materials utilized for the previous stages.

Portable, Weatherproof Stage

• Stage dimensions: min: 20’ x 16’ - max: 24’ x 16’

• Height of Stage: min of 2’ – max of 4’that can be adjusted at set, locking points

• Must be able to support a weight of minimum of 2,500 lbs o Weight of 10 people (at 200 lbs) & equipment

• Must be able to be set up on a variety of different and/or uneven surfaces o Stage must come with pegs to secure points of contact with the ground if placed on loose surfaces

• Must be weatherproof in order to withstand strong environmental factors o Stage must be covered with weatherproof/metal material, no exposed wood

• Must be mobile for ease of transportation, setup, and breakdown on GOV van/truck

• Must have multiple platforms that can fit in a GOV van/truck for transport

• Must have carts/hand trucks to transport the different parts of the stage

• Must be able to be set up/broken down by a minimum 2 people

Stairs

• Must have 2 sets of stairs, one for each side of the stage

• Must be made with metal/weatherproof material with tread on stairs

• Must have railings for safety moving up and down the stairs to support the weight of personnel while being used

• Must match the height of stage in any capacity

• 2 – 6 steps for each staircase

Miscellaneous Requirements

• Color of materials and accessories must match (i.e. all black, metallic, or combination of both)

• Curtains to cover the front, left, and right sides of the stage when fully assembled

• Stage must come with assembly and disassembly instructions

• Vendor must contact 15 WG/Protocol 3-business days before delivery of equipment