FA4690-19-Q-A015, Attachment 1, Salient Characteristic

Salient Characteristics

Ellsworth AFB Fire & Emergency Services Confined Space Rescue Trainer

Confined Space Rescue Trainer Container:

1. The trainer container shall be a one-story structure fabricated from (1) new 8ft wide x 8.5ft tall x 40ft long International Organization for Standardization (ISO) Freight Container or similar container materials and dimensions providing minimum 640 sq.

ft. of training space.

2. The exterior of the trainer container will be coated with a high grade industrial direct to metal paint.

3. The container will include (1) standard personnel door located within the container sidewall to serve as the main point of egress into the system. Additionally, provide (1) standard 3ft x 3ft window within the container sidewall.

4. The container will include (1) cargo door located at container end to serve as a secondary point of egress into the system.

5. The container flooring will be diamond plate steel material.

6. The trainer container will include an OSHA compliant galvanized guardrail, toe-kick, and bar grating system encompassing the container rooftop. This system will provide a non-slip training area at the container rooftop.

7. The trainer will include an OSHA compliant galvanized caged ladder for container rooftop access.

8. The trainer will include a galvanized exterior stair and handrail system from ground level to the container rooftop.

9. The trainer container will include an electrical and lighting system consisting of (3) interior lights with shatter proof covers and (2) wall receptacles/light switches.

Additionally, (4) exterior 400 watt lights and an exterior mounted electrical load center ready for on-site (government provided) hard wire connection to existing electrical service.

Confined Space Rescue Trainer Features and Training Props:

1. The trainer container will contain a reconfigurable confined space and USAR (Urban

Search and Rescue) maze system consisting of several full-height continuous steel panels of various types (solid full-height, low crawl, and high crawl) extending from the container floor to the container ceiling. Additionally, electrical entanglement and ramp props will also be included and designed to work in conjunction with the maze system. The maze system will be constructed such that the user can rotate panel’s 360-degrees to quickly reconfigure the floor space to achieve various training scenarios.

2. The trainer container will contain a raised mid-height platform that is 15ft in length fabricated within the container and designed to receive half-height reconfigurable steel panels. The panels will extend from the platform base to the container ceiling.

The system will be constructed such that the user can rotate the panel’s 360-degrees to quickly reconfigure the space. An upper side access hatch will be provided to access the mid-height platform, the hatch will contain a lockable hinging cover.

3. The trainer container will contain a removable shoring prop located below the mid-height platform and hinged from the container sidewall. The prop is intended to emulate a building collapse scenario for blocking and shoring training. A lower side access hatch to access the shoring prop will be provided, the hatch will contain a lockable hinging cover.

4. The trainer will contain a wall breach prop extending between the container floor and the mid- height platform. The prop is designed to emulate typical wood framed construction and prepare the user for breaching scenarios.

5. The trainer will contain movable stairs extending from the container floor to the mid-height platform. The stairs provide access to the mid-height platform level.

6. The trainer will contain a confined space tube and hatch cover prop system located inside at the container end opposite the mid-height platform. The system will contain a hatch cover at the container rooftop with an interconnected vertical tube. The vertical tube is interconnected with an interior container horizontal tube, the horizontal tube will extend 30ft out of the container sidewall terminating with a hatch cover. The other end of the horizontal tube will include an additional vertical tube elbow which terminates above the container floor level. All hatches will contain lockable covers.

7. The trainer will include a galvanized tanker prop located at the container rooftop. The prop contains (2) hatch covers with lockable covers. One of the covers provides access into the prop and the second cover provides access to the mid-height platform located within the container.

8. The trainer will contain a steel panel cutting prop designed to allow the user to insert various types of materials including roll-up doors, plywood, siding and garage doors.

9. The trainer will include a variable angle rebar cutting prop allowing the user to insert rebar at various angles for saw endurance training.

10. The trainer will include a steel fabricated burglar bar window prop allowing placement of rebar and breach material for saw cutting and window breaching training.

Contractors Responsibilities:

• Delivery and crane install.

Ellsworth AFB Responsibilities:

• Site prep, trainer will be placed on 10 inch concrete pad located at fire training area.

Electrical service hook-up.