TECHNICAL

SPECIFICATIONS

Non- Concrete Test Weights

1. SCOPE OF SPECIFICATIONS

1.1. This specification describes the requirements to provide three Non- Concrete test weights (10,000, 7,000 and 3,000 lbs.) for the purpose of testing mission critical MJ-1C, MHU-83C/D/E, MJ-40, Munitions Handling/Loading Lift Truck and the Scissors Lift Assembly. Weights must not be made of concrete.

2. APPLICABLE DOCUMENTS

2 .1. T.O. 35D3-2-25-11(MJ-1C), T.O. 35D5-3-8-31 (MHU-83C/D/E), T.O. 35D3-9-21-1 (MJ-40), T.O. 35D5-3-12-1(Scissor Lift)

2.1.1 Each of the above mentioned Technical Orders require use of the required weights. The 3,000 lb weight is allowed to have the following variance: +125/-0 lbs. If this one is greater than 3,125 lb or less than 3,000 lbs it will not be accepted. The 7,000 lb weight is allowed the following variance: +250/-0 lbs. If this one is greater than 7,250 lbs or less than 7,000 lbs it will not be accepted. The 10,000 lb weight is allowed the following variance: +350/-0 lbs. If this one is greater than 10,350 lbs or less than 10,000 lbs it will not be accepted.

2.2 Dimensions required are as listed:

3,000 pound weight: All internal dimensions indicated are the minimum that is needed to allow for adequate clearance around munitions handling lift truck. Dimensions must not be less than 57”x 10”x 24”

7,000 pound weight: All internal dimensions indicated are the minimum that is needed to allow for be less than 32.5”x 24”x 24”

10,000 pound weight: All internal dimensions indicated are the minimum that is needed to allow for be less than 32.5”x 24”x 24”

Minimum internal dimensions must be exact. All other dimensions may vary to keep the weight with in parameters and still allow for a safe stable base.