Sources_Sought_-_MIMPRS_HVAC.pdf
PDF 27 KB Posted
- Attached to
- Mobile Unit HVAC Replacement Federal contract opportunity
- Solicitation number
- FA4686-18-R-0021
About this file
Sources Sought Announcement with Returnable (page 3)
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sources_Sought_SON.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOURCES SOUGHT
HVAC for Mobile Unit Beale Air Force Base, California
THIS IS A SOURCES SOUGHT SYNOPSIS ONLY. THIS IS NOT A SOLICITATION FOR
PROPOSALS/QUOTES AND NO CONTRACT WILL BE AWARDED FROM THIS
SOURCES SOUGHT. PLEASE DO NOT REQUEST A COPY OF A SOLICITATION, AS
ONE DOES NOT EXIST.
The 9th Contracting Squadron, Beale AFB, CA, is seeking information about qualified sources who can provide two commercial-type vertical wall mount counterflow air conditioners (non-ozone depleting R-410A refrigerant), two matching economizers and a telecom lead/lag controller. Each unit must fit the existing locations/limitations on the MIMPS, .- 86" H x -43" W x -23" D. The supply air (-9 W' x -30") and return air opening (-15 7/8" x- 30") should match existing openings. The bottom of the openings are -6" and-42" from the bottom, respectively. The vertical wall mount counterflow air conditioners must be 60,000 BTUH (5 Ton), 208/230v, 30, 60 Hz (three phase) and equipped with 9kW electrical heat.
Each commercial unit must have a factory installed economizer that is adjustable from 63 degrees F (17° C) at 50% relative humidity to 73 degrees F (23° C) at 50% relative humidity. The telecom HVAC controller must be able to control two redundant air conditioners, heat pumps or air conditioners with 2-stage compressors. Have seven outputs for remote alarm or notification. Have an LED panel to display status to indicate heat, cool, power, and lead unit. This should be indicated via LED screen displaying the fault and LED flashing alarm. Connect using RS-485 communication via a RJl 1 jack. Be adjustable and have the ability to make any settings to the Master unit with the Slave unit updating simultaneously.
The contractor shall provide all supervision, labor, materials, and equipment to remove and properly dispose of two (2) existing wall mounted HVAC units with associated hardware.
Install two (2) new commercial vertical wall mount counterflow air conditioners with two
(2) new factory installed economizers and program one (1) new telecom lead/lag controller.
Provide all technical manuals or source documentation. Commercial wall units must use non-ozone depleting R-41OA refrigerant and conform to UL standard 1995, 4th Edition and, CAN/CSA C22.22, NO. 236-11 and tested in accordance with the ASHARE standard.
The expeditious replacement of the HVAC system is essential and is a driver over cost. We need this system to be fully functional within 45 days from contract award. Time constraints are mission critical in satisfying this requirement. Cost elements are secondary.
No reimbursement will be made for any costs associated with providing information to this Sources Sought or any follow-up information requests. The purpose of this synopsis is to notify the industry of the intent for a potential contract action and to gain knowledge of potentially qualified sources and their size classifications (small business, large business, service-disabled veteran, etc.)
• Proposed NAICS: 238220, HVAC (heating, ventilation and air-conditioning) contractors
• PSC: 4120/Air Conditioning Equipment
• The small business size standard for this procurement, as defined by the U.S. Small
Business Administration is $15 M
Please provide any suggestions if you feel a more appropriate NAICS exists. The proposed action is anticipated to be issued as a purchase order.
Interested parties should submit a one paragraph notice of ability to provide the required service(s) and complete and return the requested information below NLT 1300 PST on Friday, 23 February 2018, to 2d Lt Sherry Jacobson at sherry.jacobson@us.af.mil .
mailto:sherry.jacobson@us.af.mil
Sources Sought HVAC for Mobile Unit
Please submit answers to the following NLT 1300 PST on Friday, 23 February, 2018.
Business Name:
Address:
Point of Contact (POC):
Phone Number:
E-mail Address of POC:
DUNS:
CAGE Code:
Circle One: Offer is / is not a small business
Circle One: Offeror is / is not registered in SAM
GSA Contract Number (if applicable):
Other Classifications:
(I.e., HUBZone, Women-owned, Veteran-owned, etc.)
File details come from the government source that posted it.