Vertical Carousels shall come equipped with a lockable lightweight one piece sliding door. Self counterbalanced sliding door can be opened and closed with minimal effort. Two-piece sliding doors without counterbalance are not acceptable. Vertical Carousels must have a 100% Reliable
Safety Security System. Vertical Carousels shall come equipped with finger protection safety buffer at rear of posting board. Vertical Carousels must be designed to accept transport rollers for fast and easy repositioning in the case of internal moves, providing maximum flexibility for unit positioning with minimum downtime and reinstallation costs. Vertical Carousels must have standard manual override systems allowing for the unit to be used until service technician's repair. Vertical Carousels must have a standard manual override that can be operated with the door open, so parts can be located using "drive and view", without having to know what carrier the part is stored on.
4. General Scope: The contractor shall provide all supervision, labor, materials and equipment to remove one (1) existing lift unit and install one (1) new Vertical Carousel(s) to support this requirement. The end user is responsible for supplying power to the units and for final electrical hookup. The manufacture must be certified ISO 9001 and ISO 14001. The contractor must ensure the equipment complies with DIN EN 15095 "Power-operated mobile racking and shelving, carousels and storage lifts" and has been tested and certified by TOV (Technical
Observation and Control), a USA NRTL and Canadian CB.