DesignSpan Building in a Box (or equal) Statement of Work

1) RED HORSE uses the Ultimate Building Machine for K-Span construction projects. This requirement is for DesignSpan Building in a Box or equivalent structural material in accordance with the below specifications for the construction of the building as shown in the attached designs on Pgs. A-1, A-2, and A-3. The structural material for the RED HORSE Electrical Storage K-Span includes:

a) Structural steel- .043” thick by 24” wide painted light sand tan. (Qty 50,000 lbs)

i) Note: Must be compatible with the MIC-120 Ultimate Building Machine that RED HORSE will be using on the project.

b) Foundation forming accessories:

i) Base Angle, ¼”x 3” x 20’ long (Qty 18)

ii) Shed40 pipe, ¾” ID, plain end @ 36” in length (Qty 200)

iii) All Thread 12-13B, 40” in length (Qty 200)

iv) Foundation form fastener kit (Qty 1)

c) Door Kit, Left Hand Reverse Swing opening, 36” x 80”, 12 Gauge steel two-piece frame, 18 Gauge single entry hollow door, pneumatic closure, grey primed, panic hardware, and associated consumables (mastic tape, caulk, self-drilling screws and rivets). (Qty 2)

i) Note: Exterior doors with the closers must be level 4, physical performance Level A doors complying with ANSI/SDI A250.8, Standard Steel Doors and Frames. Frames must match door level. Exterior door frames must be welded type…Provide Grade 1 hardware typical. Locksets must be mortise type, Series 1000 as defined by ANSI/BHMA – A156.13, Mortise Locks and Latches for shop and maintenance level doors. Hinges for doors with closers must be full buut hinges except special types are required. Closers must be the best and highest grade available for each manufacturer.

d) Overhead door kit: (Qty 2)

i) Installation Frame

ii) Industrial Grade Roll-Up door, 16’W X 14’H

iii) Power Operated – motor size ¾ HP, 240V, 3 Phase

iv) Trim and Header Assembly

v) Associated Hardware

e) Louver Kit, Heavy Duty, motorized, intake louvers/dampers with interior screen mesh: (Qty 2)

i) Steel insulation trim for 6” thick insulation. Primer painted

ii) Industrial grade power ventilator

iii) Associated hardware

f) Urethane Insulation Material Kit: (Qty 1 Each)

i) This system must be utilized with the Ultimate Building Machine proprietary MIC-650 TM Mobile Insulation System For Urethane and the MIC-850 TM Mobile Fire Protection System For Urethane.

g) Building Consumables:

i) Mastic Tape rolls (Qty 24)

ii) TEK Screw, rubber washer, #12-14, 1” long (Qty 5,000)

iii) Exterior silicone tube, white (Qty 14)

File details come from the government source that posted it. Updated .