Attach_2_Submittal_Schedule.xls
XLS spreadsheet 62 KB Posted
- Attached to
- Repair Roads inside WSA Federal contract opportunity
- Solicitation number
- FA4626-16-R-0029
About this file
Attachment 2 Material Submittal
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amended_Detail_4_C3.0.jpg | JPG image | |
| Questions_and_Answers_2.docx | DOCX document | |
| Drawing_Plate_C2.2_Clarification.docx | DOCX document | |
| Photos.zip | ZIP file | |
| Geo-Grid_Specification_Clarification.pdf | ||
| Site_Visit_Sign_In.pdf | ||
| WSA_Roads_questions_V1.docx | DOCX document | |
| Amendment_0001.docx | DOCX document | |
| Attch_9_Subcontractor_Consent.doc | DOC document | |
| Attach_4_Drawings.zip | ZIP file | |
| Attach_1_Specifications.zip | ZIP file | |
| Attach_5_Wage_Determination.docx | DOCX document | |
| Solicitation.docx | DOCX document | |
| Attach_7_Special_Contract_Requirements.docx | DOCX document | |
| Attch_8_Past_Performance_Questionaire.docx | DOCX document | |
| Attach_6_Installation_Perimeter_Access.pdf | ||
| Attach_3_Schedule_of_Drawings.docx | DOCX document | |
| SYNOP_FOR_SOL_-_16R0029.doc | DOC document | |
| SYNOP_FOR_SOL_-_16R0029.doc | DOC document |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| SCHEDULE OF MATERIALS SUBMITTALS | Project Number | Project Title: | Solicitation/Contract No. | ||||||||||||||||||
| NZAS 11-1027 | REPAIR ROADS INSIDE WSA | FA4626-16-R-0029 | |||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR | ||||||||||||||||||||
| Number of Copies Required | |||||||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | CERTIFICATION OF COMPLIANCE | SHOP DRAWINGS | SAMPLES | COLOR SELECTION | MANUFACTURER'S RECOMMENDATIONS | MANUFACTURER'S WARRANTY | CATALOG DATA | OPERATING INSTRUCTIONS | NOTIFICATION | OTHER | REQUIRED SUBMISSION DATE (BY CONTRACTOR) | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | SUBMITTAL NUMBERS | DATE CONTRACTOR NOTIFIED | CONTRACTOR RESUBMITTAL | FINAL APPROVAL | REMARKS | |
| APPROVED | DIS- APPROVED | ||||||||||||||||||||
| 1 | As Built Field Data 01 00 00 - 3.5.2 | 4 | 3 PTFA | ||||||||||||||||||
| 2 | Preparation As-Built Contract Drawing 01 00 00 - 3.5.3 | 1 | AFA | ||||||||||||||||||
| 3 | Operating and Maintenance Instructions 01 00 00 - 3.7 | 4 | 3 PTFA | ||||||||||||||||||
| 4 | Contractor Furnished Equipment List 01 00 00 - 3.8.1 | 4 | 3 PTFA | ||||||||||||||||||
| 5 | Guarantees 01 00 00 - 3.8.2 | 4 | 10 PTFA | ||||||||||||||||||
| 6 | Shop Drawings 01 00 00 - 3.10 as Required by Technical Specifications | 4 | 10 PTSA | ||||||||||||||||||
| 7 | Start of Work Notification 01 00 00 - 3.12 | 1 | PTSW | ||||||||||||||||||
| 8 | Notice of Final Inspection 01 00 00 3.12 | 1 | 14 PTFI | ||||||||||||||||||
| 9 | Construction Near Utility Systems 01 00 00 - 3.13 (AF Form 103) | 1 | PTSW | ||||||||||||||||||
| 10 | Utility Outage Notices 01 00 00 - 3.14 | 1 | 14 PTO | ||||||||||||||||||
| 11 | Quality Control Plan 01 00 00 - 3.18.2 | 4 | PTSW | ||||||||||||||||||
| 12 | Quality Control Records 01 00 00 - 3.18.4 | 1 | EWD | ||||||||||||||||||
| 13 | 1354 Checklist (Property Inventory Checklist) 01 00 00 3.30 (AF Form 1354) | 4 | 10 Days PTFI | ||||||||||||||||||
| 14 | Nuclear Densometers 01 00 00 - 3.22 | 4 | 30 days PTSW | ||||||||||||||||||
| 15 | Construction Dewatering Permit - 01 36 00 - 2.3 & 4.1.1 | 4 | PTSW | ||||||||||||||||||
| 16 | Construction Storm Water Notice of Intent 01 36 00 - 2.3 & 4.3.1.A | 4 | PTSW | ||||||||||||||||||
| 17 | Construction Storm Water Polution Prevention Plan 01 36 00 - 2.3 & 4.3.1.B | 4 | PTSW | ||||||||||||||||||
| 18 | Construction Storm Water Notice of Termination 01 36 00 - 2.3 & 4.3.1.1 | 4 | PTSW | ||||||||||||||||||
| 19 | Demolition Activities Notification 01 36 00 - 2.4 | 4 | PTSW | ||||||||||||||||||
| 20 | Hazardous Materials Report EESOH-MIS 3952 - 01 36 00 - 8.1.2 | 4 | PTSW | ||||||||||||||||||
| 21 | Monthly Report of Solid Waste Disposal and Diversion - 01 36 00 - 11.3 | 4 | Monthly | ||||||||||||||||||
| 22 | Waste Management Plan - 01 36 00 - 11.6 | 4 | PTSW | ||||||||||||||||||
| 23 | Recovered Materials Written Determination Form - 01 36 00 - 12.4 | 4 | PTSW | ||||||||||||||||||
| 24 | Recycled Material Use Report - 01 36 00 - 12.5 | 4 | PTSW | ||||||||||||||||||
| 25 | Crack Seal Manufacturer's Literature and Installation Instructions 31 01 17 - 1.1 | 4 | PTSW | ||||||||||||||||||
| 26 | Subrade Proctor 31 22 00 1.2.1 | 1 | PTSW | ||||||||||||||||||
| 27 | Subgrade Compaction Results 31 22 00 1.2.2 | 1 | SRO | ||||||||||||||||||
| 28 | Fill Material Proctor 31 22 00 1.2.3 | 1 | PTSW | ||||||||||||||||||
| 29 | Fill Material Compaction Results 31 22 00 1.2.4 | 1 | SRO | ||||||||||||||||||
| 30 | Geotextile 32 01 17 1.1.1 | 4 | PTSW | ||||||||||||||||||
| 31 | Crushed Gravel Materials Properties 32 10 00 1.1.1 | 1 | PTSW | ||||||||||||||||||
| 32 | Plant Mix Gravel 32 10 00 1.1.2 | 1 | PTSW | ||||||||||||||||||
| 33 | Asphalt Cement 32 10 00 1.1.3 | 1 | PTSW | ||||||||||||||||||
| 34 | Tack Coat 32 10 00 1.1.4 | 1 | PTSW | ||||||||||||||||||
| 35 | Asphalt Mix Design 32 10 00 1.1.5 | 1 | PTSW | ||||||||||||||||||
| 36 | Quality Control Test Result 32 10 00 1.1.6 | 1 | SRO | ||||||||||||||||||
| 37 | Not Used | ||||||||||||||||||||
| 38 | Base Course Aggregate Test Reports 32 11 33 1.1 | 1 | PTSW | ||||||||||||||||||
| 39 | Not Used | ||||||||||||||||||||
| 40 | Not Used | 1 | SRO | ||||||||||||||||||
| 41 | Not Used | ||||||||||||||||||||
| 42 | Not Used | ||||||||||||||||||||
| 43 | Reflective Glass Beads 32 17 23 3.2 | 1 | PTSW | ||||||||||||||||||
| 44 | |||||||||||||||||||||
| 45 | |||||||||||||||||||||
| 46 | |||||||||||||||||||||
| 47 | |||||||||||||||||||||
| 48 | |||||||||||||||||||||
| 49 | |||||||||||||||||||||
| 50 | |||||||||||||||||||||
| 51 | |||||||||||||||||||||
| 52 | |||||||||||||||||||||
| 53 | |||||||||||||||||||||
| 54 | |||||||||||||||||||||
| 55 | |||||||||||||||||||||
| 56 | |||||||||||||||||||||
| 57 | |||||||||||||||||||||
| 58 | |||||||||||||||||||||
| 59 | |||||||||||||||||||||
| 60 | |||||||||||||||||||||
| 61 | |||||||||||||||||||||
| 62 | |||||||||||||||||||||
| 63 | |||||||||||||||||||||
| 64 | |||||||||||||||||||||
| 65 | |||||||||||||||||||||
| 66 | |||||||||||||||||||||
| 67 | |||||||||||||||||||||
| 68 | |||||||||||||||||||||
| 69 | |||||||||||||||||||||
| 70 | |||||||||||||||||||||
| 71 | |||||||||||||||||||||
| 72 | |||||||||||||||||||||
| 73 | |||||||||||||||||||||
| 74 | |||||||||||||||||||||
| 75 | |||||||||||||||||||||
| 76 | |||||||||||||||||||||
| 77 | |||||||||||||||||||||
| 78 | |||||||||||||||||||||
| 79 | |||||||||||||||||||||
| 80 | |||||||||||||||||||||
| 81 | |||||||||||||||||||||
| 82 | |||||||||||||||||||||
| 83 | |||||||||||||||||||||
| 44 | Product Data for Grounding, 26 06 00, 1.3.A | 3 | PTSW | ||||||||||||||||||
| 45 | Grounding Test Reports, 26 06 00, 1.3.B | 3 | 3 AWC | ||||||||||||||||||
| 46 | Sidewalk Boxes, 26 11 00, 1.3.A | 3 | PTSW | ||||||||||||||||||
| 47 | Conduits and Supports, 26 11 00, 1.3.B | 3 | PTSW | ||||||||||||||||||
| 48 | Conductors Under 600-V, 26 12 00, 1.3.A.1 | PTSW | |||||||||||||||||||
| 49 | Insulation Resistance Test Results, 26 12 00, 1.3.B | 3 AWC | |||||||||||||||||||
| 50 | Panelboard Shop Drawings, 26 24 16, 1.3.B | 3 | PTSW | ||||||||||||||||||
| 51 | Panelboard Product Data, 26 24 16, 1.3.C | 3 | PTSW | ||||||||||||||||||
| 52 | Transformer Info, 26 27 10, 1.3.A | 3 | 3 | PTSW | |||||||||||||||||
| 53 | Transformer O & M Info, 26 27 10, 1.3.B | 3 | 3 AFI | ||||||||||||||||||
| 54 | Transformer PCB Test and Ser. No. 26 27 10, 1.3.C | 3 | PTFA | ||||||||||||||||||
| 55 | Surge Arrestors and Cut-Outs, 26 27 10, 1.3.D | 3 | PTSW | ||||||||||||||||||
| Schedule of Abbreviations: | |||||||||||||||||||||
| AWC | = After Work Completed | BMF | = | Before Material Delivery | |||||||||||||||||
| PTSW | = Prior to Starting Work | SN | = | Advance Notification | |||||||||||||||||
| AFA | = After Final Acceptance | SRO | = | After Each Occurrence | |||||||||||||||||
| PTO | = Prior to Outage | PTFI | = | Prior to Final Inspection | |||||||||||||||||
| PTNT | = Prior to Notice to Proceed | PTFP | = | Prior to Final Payment | |||||||||||||||||
| ANTP | = After Notice to Proceed | PTCW | = | Prior to Completing Work | |||||||||||||||||
| EWD | = Each work day AF Form 3000 not required | AFI | = | After Final Inspection | |||||||||||||||||
| PTFA | = Prior to Final Acceptance | PTSA | = | Prior To Start of Action | |||||||||||||||||
| ACA | = After Contract Award | PSS | = | Per Submittal Schedule |
&L&"Times New Roman,Regular"&12Attachment 2&CTitle: Repair Roads Inside WSA&R&"Times New Roman,Regular"&12FA4626-16-R-0029 &L&"Times New Roman,Regular"&12AF Form 66 &F-&D&C&"Times New Roman,Regular"&12 01330a-&P
REQUIRED TECHNICAL SUBMITTALS
File details come from the government source that posted it. Updated .