STATEMENT OF WORK
This requirement is for purchase, delivery and installation of a penetrant line and 8 separate stations in accordance with the below specifications.
Standards of Performance: All work performed to install Penetrant Line will be performed in such a way that it will not significantly distract from the overall appearance of the shop. All pallets, crating material, and debris will be removed from site upon completion of installation.
Contractors Responsibility The Contractor shall furnish the following in order to complete satisfactory installation.
1. The contractor shall provide a contract manager who shall be responsible for the performance of the work. The name of this person and an alternate(s) who shall act for the contractor when the manager is absent shall be designated.
2. The contractor shall provide qualified, experienced installers to perform the work as required.
3. The contractor shall take all safety precautions during the performance of this work.
4. The contractor will provide all safety equipment required to complete installation.
5. The contractor will provide for removal and disposal of the unit that is being replaced
Requirements There are 8 separate stations required they are as follows:
1. Penetrant Station Features:
· Outside dimensions: 48” L x 34” W x 36” H
· Inside dimensions: 43¼” x 29¼” x 30¾”
· Heavy gauge stainless steel tank
· Structural steel framework
· Bottom supported tank
· Protective hinged tank cover
· Drain fitting
· Epoxy coated exterior
2. Drain Station Features:
· Dimensions: 48” L x 34” W x 8” H
· Corrosion resistant rollers --nominal 2” O.D. on 4” centers
· Fully framed, free standing station
· Stainless steel drain pan
· Interchangeable rollers are easily installed or removed
· Drain fitting 3. Rinse station Features:
· Outside dimensions: 48” L x 34” W x 36” H
· Inside dimensions: 43¼” x 29¼” x 29¾”
· Heavy gauge stainless steel tank
· Structural steel framework
· Bottom supported tank
· Spray hose and nozzle
· Water pressure regulator and gauge
· Water temperature gauge
· Split rinse hood, folds to the rear
· Stainless steel rear splash shield
· Work stand
- Mounts for handheld blacklight
4. Emulsifier Station Features:
| · | Outside dimensions: 48” L x 34” W x 36” H |
| · | Inside dimensions: 43¼” x 29¼” x 30¾” |
| · | Heavy gauge stainless steel tank |
| · | Structural steel framework |
| · | Bottom supported tank |
| · | Protective hinged tank cover |
| · | Drain fitting |
| · | Epoxy coated exterior |
5. Wet Developer Station Features:
· Outside dimensions: 48” L x 34” W x 36” H
· Inside dimensions: 43¼” x 29¼” x 30¾”
· Heavy gauge stainless steel tank
· Structural steel framework
· Bottom supported tank
· Protective hinged tank cover ·Drain fitting ·Epoxy coated exterior
6. Drain Station Features:
· Dimensions: 48” L x 34” W x 8” H
· Corrosion resistant rollers --nominal 2” O.D. on 4” centers
· Fully framed, free standing station
· Stainless steel drain pan
· Interchangeable rollers are easily installed or removed
· Drain fitting
7. Split Roof Dryer Features:
· Outside dimensions: 72” L x 36” W x 85” H
· Inside dimensions: 68” x 30” x 44_”
· Split roof with flame resistant curtain entry and exit (To accommodate customer provided overhead conveyor)
· Structural steel framework
· Heavy gauge steel panels
· Insulated interior panel with heat reflective surfaces
· Removable fans and heater elements
· Adjustable, calibrated digital thermostat
· Air circulation fans
· Wire mesh beneath roller grille
· Electrical requirement: 230 or 460 volt (specify one), 60 hertz, 3 phase facility power
8. Inspection Station Features:
· Outside dimensions: 72” L x 34” W (plus 24” from unit to curtain) x 76¾” H
· Inside dimensions: 72” x 34” x 31¼”
· Structural steel framework
· Roller grille
· Model ZB-100F fan-cooled black light (2)
· White light
· Ventilating fan
· Flame resistant curtain
· Solid roof
· Operator switch panel
· Full length curtains (4” above floor) enclose work area
· Electrical requirement: 115 volt, 60 hertz, single phase facility power
· Bottom supported tank
· Protective hinged tank cover
· Drain fitting
· Epoxy coated exterior