Questions and Answers 29 June 2016
Q1. What is the ambient temperature & humidity of the space (room) where the unit will be installed (i.e. air conditioned)?
Q2. What is the discharge pressure requirement for the nitrogen compressor? Does it need to only provide 500 psi of nitrogen or does it really need to be 5000 psi?
A1. Our shop is not air conditioned in any way shape or form. It gets pretty hot in here and with our parts washers going it gets humid as well. We have some fans and port-a-cools but that's it.
A2. The 5000 psi is strictly for the storage containers to show how much is stored up. The max psi leaving the unit should not exceed 500 psi.