3_-_Salient_Characteristics_-_ARRK_(12_Sep_2018).pdf

PDF 49 KB Posted

Attached to
ARRK Deployable Assets Federal contract opportunity
Solicitation number
FA441718Q0229
Issued by
Department of the Air Force Special Operations Command

About this file

Updated Salient Characteristics (12 Sep 18)

View the file

Other files for this federal contract opportunity

Other files attached to ARRK Deployable Assets, newest first.
File Type Posted
3_-_RFQ_-_(ARRK).pdf PDF
3_-_Salient_Characteristics_-_ARRK.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ARRK UTC Replacement Salient Characteristics

12 Sept 2018

Salient Characteristics and Performance Specifications For Replacement of

Air Rapid Response Kit (ARRK) (World Wide Deployable)

1. Air Rapid Response Kit (ARRK) Program Description/Details: AFSOC deployable forces require a versatile bed-down system that supports the distinctive requirements of the AFSOC warfighter. AFSOC forces are often the first into austere, remote and isolated areas. These locations are traditionally bare base with no shelter or sanitation. The ARRK was developed to meet the unique requirements of the AFSOC warfighter and provide basic shelter/sanitation for up to 30 days. The ARRK program consists of a family of systems.

2. Requirements:

a. Delivery: There will be one delivery location for the items purchase. The top line of all spreadsheets will mention delivery location.

i. Cannon AFB, NM:

506 N. Air Commando Way (Bldg 269), Cannon AFB, NM 88101

3. This procurement consists of the following items, if equivalent items are quoted items will need to meet the salient characteristics provided in the Brand Name or Equal Nomenclature. Vendors are responsible for providing product literature supporting equivalent products in accordance with 52.211-6, Brand Name or Equal.

CANNON AFB 4F9J5 WATER PURIFICATION KIT

Water Purification Kit will provide up to 5000 Gallons of potable water each day for drinking water and troop hygiene.

Brand Name Part #

Brand Name Brand Name or Equal Nomenclature Qty

Other than Brand name

Information – If Equivalent Item

Quoted

NA NA EN ARRK WATER PURIFICATION KIT NA NA

AWI-WB-3000-P 3000 GL WATER BLADDER (BLUE) 1

AWI-TRP-A01 TRANSFER PUMP PACKAGE 1

ASPEN WATER, P/N

AWI-55-001SET-P

ASPEN WATER

SOLAR ARRAY

#AWI-SO-55A03

ASPEN 5500M WATER PURIFICIATION

SYSTEM

FULLY ENCLOSED NON-SALINE

WATER PURIFICATION SYSTEM;

SUPPLIES AT LEAST 5,000 GALLONS

PER DAY/170 GALLONS PER HOUR OF

HIGHLY PURIFIED WATER FROM ANY

NON-SALINE WATER SOURCE (COLOR

BLACK)

360 WATTS SOLAR ARRAY

CONTROLLER AND BATTERY PACK

FOLDING SOLAR OPTION FOR ASPEN

5500M 1

AWI-CHL-55-A01 CHLORINATOR OPTION, 5500M 1

AWI-SC-1002

CHLORINE TABLET (PACK OF 6) SIZED

TO TREAT 5 GALLONS OF WATER PER

TABLET 1

AWI-MAINT-55M-1

MAINTENANCE PARTS PACKAGE FOR

5500M FOR APPROXIMATELY (1) YEAR

OF SERVICE INCLUDING:

- Anchor Assy (Part # AWI-SC-1DM-A31); Qty: 1

- Anchor Line Assy (Part # AWI-SC-1DM-A30);

Qty: 1

- Cap, Dust, Connector 7 Pin (Part # AWI-55-FA- 401); Qty: 2

- Cord 12 Volt Out (transfer) (Part # AWI-PC- TRP-A01); Qty: 1

- Cord, 24V NATO (Part # AWI-55-PC-24V); Qty:

- Cord, AC Power, 5500M (Part # AWI-55-PC- AC1); Qty: 1

- Float Assembly (Part # AWI-55-EX-A10); Qty: 1

- Foot Valve Strainer (Part # AWI-55-EX-A11);

Qty: 1

- Hose, Inlet, Black (Part # AWI-HO-55-A01);

Qty: 1

- Hose, Inlet, Grey (Part # AWI-HO-55-A02); Qty:

- Housing, Pre-Filter (Sump) (Part # AWI-55-FA- 085B); Qty: 1

- O-Ring & Tool Kit Assy (Part # AWI-55-EX- A50); Qty: 1

- Sprayer, Assembly, Water (Part # AWI-55-EX- A09); Qty: 1

- Strainer, Mesh (Part # AWI-55-EX-A02); Qty: 1

- Tubing, Repair length (Part # AWI-55-EX-007);

- Wrench, Sump Large, Black (Part # AWI-55- EX-017); Qty: 1 1

AWI-CONS-55M-1

CONSUMABLES PACKAGE (ASPEN 5500)

FOR EACH SYSTEM FOR APPROX (1)

YEAR OF SERVICE INCLUDING:

- Bulb, UV (Part # AWI-5M-UV-BLB); Qty: 1

- Filter, Post treatment 20" (Part # AWI-FL-55- 006); Qty: 12

- Media Canister Assembly (Part # AWI-5M- MEDCAN); Qty: 12

- Pre-Filter, 1 Mic, 4.5 x 20 (Part # AWI-FL-1DM- 007BX); Qty: 6

- Pre-Filter, 5 Mic, 4.5 x 20 (Part # AWI-FL-1DM- 005BX); Qty: 3

- Sleeve, UV Quartz 20" Length (Part # AWI-55- EX-A20); Qty: 1 1

HONDA POWER

EQUIPMENT,

EM5000SXK2ATI

GENERATOR, HONDA, EM5000

5000 WATTS, 120/240V

PROVIDES 7,000 WATTS FOR 10 SEC TO

START LARGER EQUIPMENT

RUN TIME OF 11 HOURS OR MORE

ELECTRIC START (BATTERY

INCLUDED) WITH RECOIL BACK UP 1

UT-100EXT

CORD, EXT, 100FT, 12/3

BOTTOM LINE

BL05577 GAS CAN 5GAL PLASTIC 10

BOTTOM LINE

BL04353 SPOUT, CAN, FLEXIBLE, FUNNEL 2

GSA ADVANTAGE

7105-01-576-6178 TABLE, FOLDING, 30” X 72” 1

NIB/ABILITYONE,

7105002698463 CHAIRS, FOLDING, STEEL 4

TRIPP LITE, PN

TLP606

SURGE PROTECTOR, TLP606

- 6 OUTLETS, 120V, 6’ CORD 2

JAMESON, 31-MC-

5004MS

LIGHT KIT, JAMESON, 31-MC-5004MS

LIGHT KIT WITH TRANSIT CASE,

CASE INCLUDES SET OF 4

FLUORESCENT LIGHTS

APPROXIMATE SIZE OF LIGHTS: 53.8”

X 16.5” X 6.7”; 2.625” TUBE DIAMETER

(+/-10% REGARDING APPROX SIZING) 1

HIGHLAND

ENGINEERING EAC90

PN UT-1923-012

EAC90 STANDARD 88" X 108"

CONTAINER WINCHING RINGS AT

BASE CORNERS

APPROX. 1,200 LBS. EMPTY WEIGHT

4 WAY FORKLIFT CAPABLE

TWO DOORS ON EACH LONG SIDE 1

UTS, TM36A1-DT

SHELTER, TM36, UTS

20’L X 19’W (380 SQUARE FEET) TENT,

EXTERNAL ALUMINUM ALLOY

FRAME WITH INTEGRATED

INTERNAL LINER; TWO (2) DOOR

ENTRY WAYS; FOUR (4) WINDOW

UNITS; TWO (2) ELECTRICAL DUCTS;

BLACKOUT CAPABILITY; STAKE KIT;

TENT COLOR SHALL BE DT (TAN) 1

CANNON AFB 4F9J7 COLD WEATHER KIT

Cold Weather Kit will be utilized to keep potable water supply from freezing.

Brand Name Part # Brand Name Brand Name or Equal Nomenclature Quantity Other than Brand

Name Information

EN ARRK COLD WEATHER ECU NA NA

Highland Engineering

EAC90 PN UT-1923-

012 (tan)

EAC90 Standard 88" X 108" CONTAINER Wincing Rings at Base Corners

- Approx. 1,200 lbs. empty weight

- 4 way forklift capable

- Two doors on each long side 1

Wel-Fab, Inc., PN WFI- 500-T

CONTAINER, FUEL, WFI-500

- 500 Gallon Fuel Bladder Containment System

- Constructed of 5052 aluminum with 20" stainless steel hatchways, one at each end of the container

- 2 lugs welded to the container for grounding of the unit

- container has 1" drain with quick disconnect fittings

- Container shall have four 10" forklift tubes

- Lid shall be constructed of 5052 aluminum with ten steel tie downs rated at 5000lbs each

- Design shall allow ability to inspect the inside of container without removing lid

- Lid shall have locking brackets to lock the top container to the bottom container while stacked with draw latches (at least four) rated at 1000 lbs each to secure the lid to the container -Shall have four lower lifting D-rings rated at least 5000 lbs each for helicopter slinging 1

WFI-AUX-T

WEL-FAB FUEL CONTAINER

HATCHWAY

LNI-500-DRUM

LNI SOLUTIONS FUEL KIT, DRUM,

FABRIC,COLLAPSIBLE, 500 GL

TM54A1-TN

SHELTER, TAN, UTS SYSTEMS

TM54

- 580 Sq. Ft Shelter System with an insulated liner 1

HDT Expeditionary Systems, Inc., PN 62-

MTH150TN

HEATER, SPACE, HDT #62-M

130k Btu/h Fuel Fired Heater - 8

11340 or equal, rating is 4A,:60B:C

4210008892491 EXT, FIRE, DRY CHEMICAL, 4

JAMESON, 31-MC-

LIGHT KIT, JAMESON, 31-MC-

- Light Kit with Transit Case, case includes set of 4 fluorescent lights

Approximate size of lights: 53.8” x 16.5” x 6.7”; 2.625” tube diameter (+/- 10% regarding approximate sizing) 1

WESTERN

SHELTER WS-

DWHM650

HEATER, WATER, WESTERN

SHELTER WS-DWHM650

FLXPH5850

HOSE, WATER, FLEXON

Water Distribution Hoses 10

Bottom Line

BL-04353 SPOUT, CAN, FLEXIBLE, FUNNEL 2

Bottom Line, PN

05577 GAS CAN 5GAL PLAST 10

UT-100EXT

CORD, EXT, 100FT, 12/3

Ready Containment

P/N FA-RC-

3000ZTOT

3000 GL ONION TANK, #OT-3

3000 gallon water containment bladder

- Self-Rising Foam Collar – No Inflation Required

- Heavy Duty PVC Material – 28oz

PVC

- Welded Seams

- Low Sides 1

4. In the quote, if proposed item is the listed part number, check the each block under column B. If other than the listed part number is submitted in your proposal, do NOT check the lock under column B, but list the Nomenclature and Part Number in Column E for each proposed item.

File details come from the government source that posted it.