Attachment_3_Questions_and_Answers.pdf

PDF 101 KB Posted

Attached to
Military Operations in Urban Training (MOUT) Structure Federal contract opportunity
Solicitation number
FA282319Q4026
Issued by
Department of the Air Force Materiel Command Test Center

About this file

Attachment 3 Questions and Answers

View the file

Other files for this federal contract opportunity

Other files attached to Military Operations in Urban Training (MOUT) Structure, newest first.
File Type Posted
Attachment_2_Salient_Characteristics_Revision_1.pdf PDF
FA282319Q4026_Combo.pdf PDF
Attachment_2_Salient_Characteristics.pdf PDF
Attachment_1_Provision_and_Clauses.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Correction to Questions and Answers for Military in Urban Training (FA282819Q4026)

Question 1

1. What is the original layout for the containers upon delivery? If single story are they standalone boxes or arranged in modular configurations such as an L-Shape? Are any of the boxes to be stacked at delivery? If so, what is the configuration?

Answer: All of the containers will be single story/standalone.

Question 2

2. What are the specifications for the steel mechanical breaching door? Is it for explosive breaching?

Answer: The breeching door is intended to be an explosive breeching door; 36" x 84".

Question 3

3. What is the thickness requirement for the anti-sink base pad?

Answer: The anti-sink pads should be 4"-6" in thickness.

Question 4

4. What are the dimensions for the steel shuttered windows? Are the shutters to designed to open and close from the outside and inside of the structures?

Answer: The windows should be 36"x36". Yes, the shutters should be able to open and close from both outside and inside the structure.

Question 5

5. What are the dimensions for the interior plywood partitions for the Urban Compound Structures (both 40 ft and 20 ft)?

Answer: Interior plywood partitions should be 5' wide x 8'6" tall for both the 20' & 40' structures

Question 6

6. If stacked do ladders or stairs need to be provided?

Answer: No ladders required.

File details come from the government source that posted it.