About this file

Amended Statement of work. Adds: move of 3 desks along with files, and clarifies other specifics to the shelving system.

View the file

Other files for this federal contract opportunity

Other files attached to Mobile Shelving System and Install, newest first.
File Type Posted
1A1-11F_-_FIRST_FLOOR_-_AREA_F_Model_(.pdf PDF
Q&A_mobile_file_shelving.docx DOCX document
STATEMENT_OF_WORK_for_Shelving_in_Outpatient_Records_edited.pdf PDF
EAFB_records_room.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

EGLIN AFB 96th MEDICAL GROUP (96MDG) RECORDS ROOM

PROVIDE HIGH DENSITY MOBILE AISLE FILING

23 February 2018

Company will remove existing shelving from Eglin Hospital (Building 2825) room 4N005 within Eglin hospital and transport items off premise for recycling/reuse. Company will relocate all existing files, approximately 50,000 folders, located in Bldg. 2825, from room 4N005 to room 1F078, where the newly installed shelving units will be erected. Delivery and installation of the high density filing system’s specification are listed below.

Further, to accommodate the transition 3 desks will be moved along with the files to the first floor records room. Must be dismantled upstairs, moved to the first floor and rebuilt there.

Specifications of shelving:

Ceiling height 7’ 11.25”

Overall unit height: 82.331”

76” uprights

4-post shelving

5-tier

Track levelers with ¾” adjustment OR laser leveled

Upper system 7,623 linear ft

Lower system 8,240 linear ft

4 dividers per shelf

Carpeted decking (24”x24” carpet tiles will be provided; adhesive will not)

Sliding track

ADA/Incline ramp

3-prong star handle with red safety occupancy indicator

Must be able to move 10,000 lbs per 1 lb of effort

Built-in anti-tip mechanism

Each carriage must be able to support up to 8,000 lbs

Continuous drive shaft a 7:1 or 10:1 gear ratio is acceptable rail joints may be staggered