DISTRIBUTION A. Approved for public release: distribution unlimited.
COMBAT SHIELD Multi-Spectral Test Set
Technical Specifications
Objective Provide a test set capable of testing Missile and Laser Warning Systems on USAF aircraft such as the AN/AAR-47. Desired capability includes three optical channels (one channel for ultraviolet (UV) stimulation and two channels for laser warning stimulation).
Laser Warning Receiver (LWR)
LWR Stimulator Channel Performance
Parameter Laser 1 Laser 2
Wavelength 905 ± 20 nm 1550 ± 35 nm
Beam width (FWHM) > 2˚ x 3˚ > 2˚ x 3˚ Boresight accuracy (to front face of test set)
< 0.5°
< 0.5°
Peak on-axis irradiance at 1 m (fixed) up to 10 kHz 300 ± 100 mW.cm-2 300 ± 100 mW.cm-2
Peak on-axis irradiance at 1 m (fixed) 10 kHz to 20 kHzi
150 ± 75 mW.cm-2
300 ± 100 mW.cm-2
Safety distance, NOHD < 100 mm 0 m
Safety distance, ENOHD < 1 m < 1 m
Laser safety class 1M 1
Pulse repetition frequency range
0.25 Hz to 20 kHz
0.25 Hz to 20 kHz
Pulse width FWHM (fixed)ii 15 ± 5 ns 28 ± 7 ns Table 1 – LWR Stimulator Channel Performance
LWR Programmable Features Pulse repetition frequency (PRF) for each channel PRF capable of being updated throughout a test mission at 20 ms intervals
UV Stimulator Performance
Parameter Specification
Stimulator peak wavelength 275 ± 2.5 nm
Stimulator spectral band width
≤ 12 nm (FWHM)
Maximum on-axis irradiance over all temperature range
50 ± 10 µW.sr-1 (12 µW.sr-1 with “operational” attenuator in placei)
Dynamic intensity control > 40 dB
Modulation depth 100 %
Rise/fall time < 100 µs (10 % to 90 %) Sampling rate 200 Hz to 6000 Hz
Sampling rate control resolution
200 Hz
Beam divergence (FWHM) ≥ 20° (circular) Source size ≤ 5 mm
Auto repeat feature Maximum number of repeats:
≥ 3200 Maximum dwell time between repeats: ≥ 5 seconds
Safety distance, NOHD < 50 mm
Safety distance, ENOHD < 1 m Table 2 – UV Stimulator Channel Performance
UV Programmable Features UV output power as a function of time Selectable time base Auto-repeat (and delay) function – capable of simulating multiple rounds of hostile fire
General System Performance Specifications
Typical operating range ≤ 300 ft
Channel synchronization < 100 µs
Maximum profile duration > 32 s
Number of test programs per library > 100
Number of libraries per media > 100
Memory media type Quick release removable
User interface Sunlight readable LCD with soft keys
Aiming Adjustable sight Remote control connection Ethernet Battery Yes
Battery lifetime > 200 test operations
External power input 12 Vdc
Weight < 10 lbs Table 3 – General System Performance Specifications
Operator Control:
Software switch on/off button Selection and load of libraries and test programs Trigger/abort of a test sequence Scroll through system messages Battery status and charge level Test program status Built-in-Test messages
Test Program Generator:
Software that permits the operator to program, configure, and remotely control a test program; includes:
Channel specific parameters Setting of media classification Setting of power down time outs Provide external triggering Provide relative timing per channel within a test program Provide operation of test program media
Other External Equipment Tripod Laser Range Finder Additional UV channel attenuators Additional batteries Profile library
Physical Interface:
External serial port connector providing Ethernet connection for remote control and external trigger for inputs/outputs
Environmental Factors
Operating temperature (with batteries) -10 °C to 55 °C
Operating temperature (external power) -20 °C to 55 °C
Storage temperature (excluding batteries) -30 °C to 71 °C
Battery storage temperature -20 °C to 60 °C, < 80 % RH (limits)
< 21 °C, < 20 % RH (for maximum shelf life)
Vibration (random and sinusoidal) MIL-PRF28800F, Class 2
Shock MIL-PRF28800F, Class 2
Bench handling MIL-PRF28800F, Class 2
Splash/dust proof IP 54
EMC qualification
Radiated emissions: EN55022 Radiated susceptibility:
EN61326-1, Table 1 (3 Vm-1) EN61326-1, Table 2 (10 Vm-1)
Electrostatic discharge: EN61326-1 Table 4 – Environmental Factors
Testing Requirement:
A Production Test Report shall be provided with each unit to show compliance with this specification and to form a basis for government acceptance of each unit.