NOT TO SCALE
AT
NATIONAL FISH AND WILDLIFE FORENSICS LABORATORY
1490 E MAIN ST, ASHLAND, OR 97520
US FISH AND WILDLIFE SERVICE
N
AG ABOVE GROUND
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
ATS AUTOMATIC TRANSFER SWITCH
C CONDUIT GROUND GND
CO CONTRACTING OFFICER
CONT CONTINUOUS
E EXISTING
EC ELECTRICAL CONTRACTOR
EG EXISTING GRADE
FF FINISH FLOOR
GC GENERAL CONTRACTOR
GWB GYPSUM WALL BOARD
GS GALVANIZED STEEL
HM HOLLOW METAL
LA LAYER
MC MECHANICAL CONTRACTOR
NL NIGHT LIGHT
PT PRESSURE TREATED
RE REGARDING
RO ROUGH OPENING
OC ON CENTER
OD OUTSIDE DIAMETER
SIM SIMILAR
TOP TOP OF PLATE
TOW TOP OF WALL
TYP TYPICAL
VERT VERTICAL
W/ WITH
WD WOOD
WP WEATHER PROOF
UG UNDERGROUND
ABBREVIATIONS
DRAWING INDEX
VICINITY MAP PROJECT LOCATION MAP
US FISH AND WILDLIFE SERVICE
SUBMITTED BY REGIONAL ENGINEER
PROGRAMMATIC REVIEW
REVIEWED FOR ADA COMPLIANCE
REVIEWED FOR ENVIRONMENTAL COMPLIANCE
CERTIFIED 10 CFR 435 COMPLIANCE (ENERGY)
SUBMITTED BY PROJECT MANAGER
DATEREV.
DRAWING NO.
DRAWN
DATE
SURVEYED DESIGNED CHECKED
UNITED STATES DEPARTMENT OF THE INTERIOR
REGION 1, OFFICE OF ENGINEERING
DESCRIPTION BY
REVIEWED FOR SAFETY COMPLIANCE MORPHOLOGY CENTER
DESIGN SECURITY SYSTEM
UPGRADE AT USFWS
FORENSICS LABORATORY
IN ASHLAND, OR
COVER SHEET
ASHLAND OREGON
MAR. 2017 1F-OR-1074-4-1.0
SHEET 1 OF 9
VERIFY SCALE
THIS BAR IS
ONE INCH ON
1"
ADJUST SCALES
ACCORDINGLY, IF
ON THIS SHEET
NOT ONE INCH
ORIGINAL DRAWING
DETAILING CONVENTIONS
SHEET WHERE
SHEET WHERE
SECTION IS TAKEN
SECTION IS SHOWN
SECTION LETTER
SECTIONS AND VIEWS:
DETAIL NUMBER
SHEET WHERE
DETAIL IS SHOWN
DETAIL IS TAKEN
SHEET WHERE
DETAILS:
PORTLAN, OREGON
NOT TO SCALE
NEW MORPHOLOGY CENTER
SECURITY SYSTEM UPGRADE
1.0 COVER SHEET
2.0 3.0 4.0 5.0
6.0
7.0 8.0 9.0
ASHLAND, OREGON 97520
1490 E MAIN ST
SECURITY LEGEND
SECURITY DEMOLITION PLAN - AREA A
SECURITY DEMOLITION PLAN - AREA B
SECURITY DEMOLITION PLAN - AREA C
SECURITY NEW PLAN - AREA A
SECURITY DETAILS
SECURITY NEW PLAN - AREA B
SECURITY NEW PLAN - AREA C
ABOVE COUNTER, 4" BACK SPLASHAC
AUTOMATIC TRANSFER SWITCHATS
ABOVE FINISHED GRADEAFG
ABOVE FINISHED FLOORAFF
BELOW GRADEBLG
BOTTOM OF DEVICEBOD
CONDUITC
CARD ACCESS SYSTEMCAS
CLOSED CIRCUIT TVCCTV
CEILINGCLG
CENTER OF DEVICECOD
COPPERCU
DIGITAL VIDEO RECORDERDVR
EXISTING(E)
ELECTRICAL CONTRACTOREC
EXHAUST FANEF
GENERAL CONTRACTORGC
GROUNDGND
FIELD ADJUSTABLE LONG TIME, SHORT TIME AND
INSTANTANEOUS
LSI
FIELD ADJUSTABLE LONG TIME, SHORT TIME, INSTANTANEOUS
AND GROUND FAULT
LSIG
MECHANICAL CONTRACTORMC
NEW(N)
NIGHT LIGHTNL
PAN-TILT-ZOOMPTZ
QUANTITYQTY
RELOCATED(R)
SURFACESF
TELECOMMUNICATIONS MAIN GROUNDING BUS BARTMGB
TELECOMMUNICATIONS BONDING BACKBONETBB
TEMPERATURE CONTROL CONTRACTORTC
TELEPHONE TERMINAL BOARDTTB
TYPICALTYP
UNDERGROUNDUG
UNLESS OTHERWISE NOTEDUON
WITHW/
WIRE MOLDWM
WEATHER PROOF (WHILE IN USE)WP
TRANSFORMERXFMR
SWITCH DESIGNATIONa,b,c etc
CIRCUIT DESIGNATION, PANEL BN1L, CIRCUITS 2,4,6BN1L-2,4,6
INDICATES DETAIL 1 ON SHEET E5011/E501
SHEET WORK NOTE
HOME RUN TO PANEL
CONDUIT CONCEALED IN CEILING OR WALL
CONDUIT CONCEALED UNDER FLOOR
LOW VOLTAGE CIRCUIT
FIBER OPTIC CABLE
CABLE TRAY
CIRCUIT, NUMBER OF HASH MARKS INDICATES NUMBER OF
CONDUCTORS IN CABLE/RACEWAY. GROUND WIRE IS NOT
SHOWN BUT SHALL BE INCLUDED. NO HASH MARKS INDICATES
2 CONDUCTORS PLUS GROUND.
SHEET DEMO WORK NOTE
SYMBOL DESCRIPTION
ABBREVIATIONS AND MISCELLANEOUS
LV
1' -6
" 1' -6
" M
IN
. I N
H
AZ
AR
D
O U
S
LO
C
AT
IO
N
S-
TO
B O
TT
O
M O
F C
AN 74
" T
O T
O P
O F
TR
IM
FINISHED CEILING
AC = ABOVE COUNTER, MINIMUM 4"
ABOVE BACKSPLASH TO
BOTTOM OF DEVICE
PANEL
BOARD
C S
F
INTERIOR BOX MOUNTING HEIGHTS
" A
FF
T
O B
O
TT
O M
O F
D
EV
IC
E
O R
" B
EL
O
W C
EI
LI
N G
T O
T O
P O
F D
EV
IC
E W
H
IC
H
EV
ER
IS
L O
W
ER
F
BOD
" M
IN
IM
U M
T O
B O
TT
O
M O
F D
EV
IC
E
FIRE FIRE
F
M O
U N
T 4"
A
BO
VE
D
O O
R F
R
AM
E
FIRE
S D
KP T CO2
48" TOD IS ACCEPTABLE FOR
CMU BLOCK CONSTRUCTION
F
BOD
BOD
BOD
BOD
FINISHED FLOOR
ELECTRICAL LEGEND
CR CARD READER
DC
MS
PS
A
LX
PRX
ML
DPS
ES
EL
AO
FA
SPEAKER SIGNAL DEVICE
DOOR CONTROLLER
MOTION SENSOR
POWER SUPPLY W/BATTERY, BY DIV 8, INSTALLED AND
CONNECTED BY DIV 27
CONNECTION TO REQUEST TO EXIT & LATCH BOLT
MONITORING
CONNECTION TO PANIC REQUEST TO EXIT
CONNECTION TO MAGNETIC DOOR LOCK
CONNECTION TO MAGNETIC DOOR POSITION SWITCH
CONNECTION TO ELECTRIC DOOR STRIKE
CONNECTION TO ELECTRIC LATCH
CONNECTION TO ELECTRIC AUTO OPENER
CONNECTION TO FIRE ALARM CONTACT
INDICATES SECURITY DOOR 1
PANEL
SCP SECURITY CONTROL PANEL
SDC SECURITY DOOR CONTROLLERS
KP KEYPAD
PT POWER TRANSFER SWITCH
DESCRIPTION
SECURITY SYSTEM
SYMBOL
REX MANUAL REQUEST TO EXIT
DS DOOR SENSOR
CLOCK HANGER RECEPTACLE
CATV JACK, WALL MOUNTED
MICROPHONE OUTLET
VOICE/DATA OUTLET - SUBSCRIPT INDICATES NUMBER OF
CABLE/JACKS - NO SUBSCRIPT INDICATES 2 CABLES/JACKS
VOICE OUTLET WALL MOUNTED
SPEAKER, SPEAKER WALL MOUNTED
VOICE/DATA OUTLET MOUNTED IN FLOORBOX- SUBSCRIPT
INDICATES NUMBER OF CABLE/JACKS - NO SUBSCRIPT
INDICATES 2 CABLES/JACKS
DATA RACK
EXISTING VOICE/DATA OUTLET
SYMBOL DESCRIPTION
COMMUNICATIONS
CATV JACK CEILING MOUNTED
CAMERA, CEILING AND WALL MOUNTED DOME, 180 DEGREE
CAMERA, CEILING MOUNTED, 360 DEGREE
CAMERA
DVR
SPS
DIGITAL VIDEO RECORDER
SURVEILLANCE POWER SUPPLY
M MONITOR
SYMBOL DESCRIPTION
SURVEILLANCE SYSTEM
AS AUDIO SENSOR
DURESS BUTTON
1F-OR-1074-4-2.0ERICKSENGOOD GOOD
KP
KP
KP
KP
KP
KP
KP KP
KP
DS DS
AS
AS
AS
AS
MS
MS
AS
DS
DS
AS
MS
AS
AS
DS
AS
DS
RH
AS
(D16)
(RH1)
(A19)
(A18)
(A17)
(A16)
(D15) (D14)
(A15)
(M8)
(A20)
(D1)
(A1)
(A2)
(M1)
(A3) (D2)
(D3)
(A4)
(M2)
157153152
C111
150 151
135e
135d
135c
135b135a
135g
137b
147f147d
147b
147a
C113
145a
C114
SECURITY DEMOLITION PLAN - AREA A
1/8"=1'-0"
1. EXISTING VIDEO SYSTEM - CAMERA AND COAXIAL
CABLE TO BE REMOVED. NEW SYSTEM TO UTILIZE
CATEGORY GRADE CABLING.
2. EXISTING CAMERA SYSTEM HEADEND LOCATION.
SHEET WORK NOTES-
A. ALL CAMERAS SHALL BE CONNECTED TO THE RECORDER VIA CATEGORY
6 UTP. THE CONTRACTOR SHALL INSTALL THE CABLE PER SECTION
271500 FOR HORIZONTAL CABLE.
B. EACH CAMERA SHALL BE MOUNTED TO A 4 SQUARE BOX SECURELY
ATTACHED TO WALLS/CEILINGS. A 1" CONDUIT SHALL BE CONNECTED TO
THE BOX AND STUBBED INTO AN ACCESSIBLE CEILING LOCATION. A
BUSHING SHALL BE PLACED ON ALL RAW ENDS OF THE CONDUITS.
C. ALL CAMERAS SHALL BE POWERED VIA POE ON THE CATEGORY 6 UTP.
THE CONTRACTOR SHALL PROVIDE ADEQUATE UPS'S FOR THE
EQUIPMENT, SUCH AS SWITCHES, CAMERAS, RECORDER - ETC
D. ALL CABLES PASSING THROUGH A PLENUM SPACE SHALL BE RATED FOR
THAT SPACE.
E. WHERE CABLES PASS THROUGH A CONDUIT SLEEVE OR THROUGH A
HARD CEILING AREA LONGER THAN 4 LINEAR FEET, A PULL STRING SHALL
BE PLACED AND SECURED FOR FUTURE CABLE PLACEMENT.
F. ALL CAMERAS SHALL BE PROGRAMMED AND LABELED PER THE EXISTING
BUILDING METHOD. THE CONTRACTOR SHALL MAKE CERTAIN THE DATE
AND TIME ARE SET CORRECTLY ON ALL CAMERAS. CONTRACTORS
SHALL USE THE NETWORK CLOCK FOR TIMEKEEPING.
G. THE CAMERA SYSTEM MUST INTERFACE TO THE ACCESS CONTROL
SYSTEM FOR RECORDING ON CARD PRESTATIONS.
H. CAMERAS SHALL BE MOUNTED AT 10' AFF AND SHALL NOT BE
OBSTRUCTED BY DOORS, FIRE SIGNALING DEVICES OR FURNISHINGS.
I. ALL EXISTING COAX - CABLE CURRENTLY SUPPORTING THE CAMERA
EQUIPMENT SHALL BE REMOVED BY THE CCTV CONTRACTOR AND
PROPERLY DISPOSED OF.
J. ALL EXISTING INTRUSION DETECTION DEVICES OR POINTS SUCH AS
MOTION SENSORS, GLASS BREAK SENSORS, ETC. SHALL BE REUSED.
HEAD END INTRUSION DETECTION PANEL(S) WILL BE REPLACED.
K. EXISTING KEYPADS TO REMAIN. SPECIFICATION SECTION 281500
"ACCESS CONTROL HARDWARE DEVICES" STATES THAT ANY CARD
READER/KEYPADS ADDED OR REPLACED MUST BE CAC-COMMON
ACCESS CARD COMPLIANT AS WELL AS HSPD-12 AND FIPS-201-2.
GENERAL NOTES
A
KEY PLAN
1F-OR-1074-4-3.0ERICKSENGOOD GOOD
KP
KP
KP
KP
KPKP
KP
KP
KP
KP KP
KP
KP
KP KP
KP
KP
DS
ASAS
DS DS
ASMS
ASAS
ASMSDS
AS
MS
DS
DS
MS
MS
MS
MS
DS
(D13)
(M7)
(M3)
(M6)
(A10)
(D8)
DS
(D7)
(A9) (A8) (A7)
(D6)
(M4) (A6)
(D5)
(EV LARGE)
(EV SMALL)
(M10)
(D4)
(E)
FREEZER
(E)
FREEZER
(E)
FREEZER
127c
127d
127e
C107
129q
129a
129f 129c129d
129n
C105
129m
118f
118e
118d
118c
118b
118a
121c
121a
121c
121b 121d
C106
122 123
C110
C108
127f 127g
127a
127b
B
KEY PLAN
SECURITY DEMOLITION PLAN - AREA B
1/8"=1'-0"
SHEET WORK NOTES-
1F-OR-1074-4-4.0
A. ALL CAMERAS SHALL BE CONNECTED TO THE RECORDER VIA CATEGORY
6 UTP. THE CONTRACTOR SHALL INSTALL THE CABLE PER SECTION
271500 FOR HORIZONTAL CABLE.
B. EACH CAMERA SHALL BE MOUNTED TO A 4 SQUARE BOX SECURELY
ATTACHED TO WALLS/CEILINGS. A 1" CONDUIT SHALL BE CONNECTED TO
THE BOX AND STUBBED INTO AN ACCESSIBLE CEILING LOCATION. A
BUSHING SHALL BE PLACED ON ALL RAW ENDS OF THE CONDUITS.
C. ALL CAMERAS SHALL BE POWERED VIA POE ON THE CATEGORY 6 UTP.
THE CONTRACTOR SHALL PROVIDE ADEQUATE UPS'S FOR THE
EQUIPMENT, SUCH AS SWITCHES, CAMERAS, RECORDER - ETC
D. ALL CABLES PASSING THROUGH A PLENUM SPACE SHALL BE RATED FOR
THAT SPACE.
E. WHERE CABLES PASS THROUGH A CONDUIT SLEEVE OR THROUGH A
HARD CEILING AREA LONGER THAN 4 LINEAR FEET, A PULL STRING SHALL
BE PLACED AND SECURED FOR FUTURE CABLE PLACEMENT.
F. ALL CAMERAS SHALL BE PROGRAMMED AND LABELED PER THE EXISTING
BUILDING METHOD. THE CONTRACTOR SHALL MAKE CERTAIN THE DATE
AND TIME ARE SET CORRECTLY ON ALL CAMERAS. CONTRACTORS
SHALL USE THE NETWORK CLOCK FOR TIMEKEEPING.
G. THE CAMERA SYSTEM MUST INTERFACE TO THE ACCESS CONTROL
SYSTEM FOR RECORDING ON CARD PRESTATIONS.
H. CAMERAS SHALL BE MOUNTED AT 10' AFF AND SHALL NOT BE
OBSTRUCTED BY DOORS, FIRE SIGNALING DEVICES OR FURNISHINGS.
I. ALL EXISTING COAX - CABLE CURRENTLY SUPPORTING THE CAMERA
EQUIPMENT SHALL BE REMOVED BY THE CCTV CONTRACTOR AND
PROPERLY DISPOSED OF.
J. ALL EXISTING INTRUSION DETECTION DEVICES OR POINTS SUCH AS
MOTION SENSORS, GLASS BREAK SENSORS, ETC. SHALL BE REUSED.
HEAD END INTRUSION DETECTION PANEL(S) WILL BE REPLACED.
K. EXISTING KEYPADS TO REMAIN. SPECIFICATION SECTION 281500
"ACCESS CONTROL HARDWARE DEVICES" STATES THAT ANY CARD
READER/KEYPADS ADDED OR REPLACED MUST BE CAC-COMMON
ACCESS CARD COMPLIANT AS WELL AS HSPD-12 AND FIPS-201-2.
GENERAL NOTES
ERICKSENGOOD GOOD
1. EXISTING VIDEO SYSTEM - CAMERA AND COAXIAL
CABLE TO BE REMOVED. NEW SYSTEM TO UTILIZE
CATEGORY GRADE CABLING.
2. EXISTING CAMERA SYSTEM HEADEND LOCATION.
KP
KP
KP
KP
MS
DS
DS
DS
AS
(A14)
(D11) (D12)
AS
(A13)
(TOP OF STAIRS)
AS
(A12)
(D9)
DS
(D10)
AS
(A11)
(ON SOFFIT)
(M5)
107 106 105 104 103 102
101b101a113 C101a
C102 115 114
C103
129c
129h 129j
129k
129i116 116a
C104
S101
C101
C
KEY PLAN
SECURITY DEMOLITION PLAN - AREA C
1/8"=1'-0"
SHEET WORK NOTES-
1F-OR-1074-4-5.0
A. ALL CAMERAS SHALL BE CONNECTED TO THE RECORDER VIA CATEGORY
6 UTP. THE CONTRACTOR SHALL INSTALL THE CABLE PER SECTION
271500 FOR HORIZONTAL CABLE.
B. EACH CAMERA SHALL BE MOUNTED TO A 4 SQUARE BOX SECURELY
ATTACHED TO WALLS/CEILINGS. A 1" CONDUIT SHALL BE CONNECTED TO
THE BOX AND STUBBED INTO AN ACCESSIBLE CEILING LOCATION. A
BUSHING SHALL BE PLACED ON ALL RAW ENDS OF THE CONDUITS.
C. ALL CAMERAS SHALL BE POWERED VIA POE ON THE CATEGORY 6 UTP.
THE CONTRACTOR SHALL PROVIDE ADEQUATE UPS'S FOR THE
EQUIPMENT, SUCH AS SWITCHES, CAMERAS, RECORDER - ETC
D. ALL CABLES PASSING THROUGH A PLENUM SPACE SHALL BE RATED FOR
THAT SPACE.
E. WHERE CABLES PASS THROUGH A CONDUIT SLEEVE OR THROUGH A
HARD CEILING AREA LONGER THAN 4 LINEAR FEET, A PULL STRING SHALL
BE PLACED AND SECURED FOR FUTURE CABLE PLACEMENT.
F. ALL CAMERAS SHALL BE PROGRAMMED AND LABELED PER THE EXISTING
BUILDING METHOD. THE CONTRACTOR SHALL MAKE CERTAIN THE DATE
AND TIME ARE SET CORRECTLY ON ALL CAMERAS. CONTRACTORS
SHALL USE THE NETWORK CLOCK FOR TIMEKEEPING.
G. THE CAMERA SYSTEM MUST INTERFACE TO THE ACCESS CONTROL
SYSTEM FOR RECORDING ON CARD PRESTATIONS.
H. CAMERAS SHALL BE MOUNTED AT 10' AFF AND SHALL NOT BE
OBSTRUCTED BY DOORS, FIRE SIGNALING DEVICES OR FURNISHINGS.
I. ALL EXISTING COAX - CABLE CURRENTLY SUPPORTING THE CAMERA
EQUIPMENT SHALL BE REMOVED BY THE CCTV CONTRACTOR AND
PROPERLY DISPOSED OF.
J. ALL EXISTING INTRUSION DETECTION DEVICES OR POINTS SUCH AS
MOTION SENSORS, GLASS BREAK SENSORS, ETC. SHALL BE REUSED.
HEAD END INTRUSION DETECTION PANEL(S) WILL BE REPLACED.
K. EXISTING KEYPADS TO REMAIN. SPECIFICATION SECTION 281500
"ACCESS CONTROL HARDWARE DEVICES" STATES THAT ANY CARD
READER/KEYPADS ADDED OR REPLACED MUST BE CAC-COMMON
ACCESS CARD COMPLIANT AS WELL AS HSPD-12 AND FIPS-201-2.
GENERAL NOTES
ERICKSENGOOD GOOD
1. EXISTING VIDEO SYSTEM - CAMERA AND COAXIAL
CABLE TO BE REMOVED. NEW SYSTEM TO UTILIZE
CATEGORY GRADE CABLING.
2. EXISTING CAMERA SYSTEM HEADEND LOCATION.
360°
MS
157153152
C111
150 151
135e
135d
135c
135b135a
135g
137b
147f147d
147b
147a
C113
145a
C114
SECURITY NEW PLAN - AREA A
1/8"=1'-0"
1. NEW VIDEO SYSTEM - TO UTILIZE CATEGORY GRADE
CABLING.
2. EXTERIOR RATED CAMERA (REFER TO
SPECIFICATIONS).
3. EXISTING CAMERA SYSTEM HEADEND LOCATION.
4. EXISTING KEYPAD HEADEND LOCATION.
5. NEW MOTION SENSOR, CONNECT TO EXISTING
SECURITY SYSTEM.
SHEET WORK NOTES-
A
KEY PLAN
1F-OR-1074-4-6.0
A. ALL CAMERAS SHALL BE CONNECTED TO THE RECORDER VIA CATEGORY
6 UTP. THE CONTRACTOR SHALL INSTALL THE CABLE PER SECTION
271500 FOR HORIZONTAL CABLE.
B. EACH CAMERA SHALL BE MOUNTED TO A 4 SQUARE BOX SECURELY
ATTACHED TO WALLS/CEILINGS. A 1" CONDUIT SHALL BE CONNECTED TO
THE BOX AND STUBBED INTO AN ACCESSIBLE CEILING LOCATION. A
BUSHING SHALL BE PLACED ON ALL RAW ENDS OF THE CONDUITS.
C. ALL CAMERAS SHALL BE POWERED VIA POE ON THE CATEGORY 6 UTP.
THE CONTRACTOR SHALL PROVIDE ADEQUATE UPS'S FOR THE
EQUIPMENT, SUCH AS SWITCHES, CAMERAS, RECORDER - ETC
D. ALL CABLES PASSING THROUGH A PLENUM SPACE SHALL BE RATED FOR
THAT SPACE.
E. WHERE CABLES PASS THROUGH A CONDUIT SLEEVE OR THROUGH A
HARD CEILING AREA LONGER THAN 4 LINEAR FEET, A PULL STRING SHALL
BE PLACED AND SECURED FOR FUTURE CABLE PLACEMENT.
F. ALL CAMERAS SHALL BE PROGRAMMED AND LABELED PER THE EXISTING
BUILDING METHOD. THE CONTRACTOR SHALL MAKE CERTAIN THE DATE
AND TIME ARE SET CORRECTLY ON ALL CAMERAS. CONTRACTORS
SHALL USE THE NETWORK CLOCK FOR TIMEKEEPING.
G. THE CAMERA SYSTEM MUST INTERFACE TO THE ACCESS CONTROL
SYSTEM FOR RECORDING ON CARD PRESTATIONS.
H. CAMERAS SHALL BE MOUNTED AT 10' AFF AND SHALL NOT BE
OBSTRUCTED BY DOORS, FIRE SIGNALING DEVICES OR FURNISHINGS.
I. ALL EXISTING COAX - CABLE CURRENTLY SUPPORTING THE CAMERA
EQUIPMENT SHALL BE REMOVED BY THE CCTV CONTRACTOR AND
PROPERLY DISPOSED OF.
J. ALL EXISTING INTRUSION DETECTION DEVICES OR POINTS SUCH AS
MOTION SENSORS, GLASS BREAK SENSORS, ETC. SHALL BE REUSED.
HEAD END INTRUSION DETECTION PANEL(S) WILL BE REPLACED.
K. EXISTING KEYPADS TO REMAIN. SPECIFICATION SECTION 281500
"ACCESS CONTROL HARDWARE DEVICES" STATES THAT ANY CARD
READER/KEYPADS ADDED OR REPLACED MUST BE CAC-COMMON
ACCESS CARD COMPLIANT AS WELL AS HSPD-12 AND FIPS-201-2.
GENERAL NOTES
ERICKSENGOOD GOOD
127c
127d
127e
C107
129q
129a
129f 129c129d
129n
C105
129m
118f
118e
118d
118c
118b
118a
121c
121a
121c
121b 121d
C106
122 123
C110
C108
127f 127g
127a
127b
B
KEY PLAN
SECURITY NEW PLAN - AREA B
1/8"=1'-0"
SHEET WORK NOTES-
1F-OR-1074-4-7.0
A. ALL CAMERAS SHALL BE CONNECTED TO THE RECORDER VIA CATEGORY
6 UTP. THE CONTRACTOR SHALL INSTALL THE CABLE PER SECTION
271500 FOR HORIZONTAL CABLE.
B. EACH CAMERA SHALL BE MOUNTED TO A 4 SQUARE BOX SECURELY
ATTACHED TO WALLS/CEILINGS. A 1" CONDUIT SHALL BE CONNECTED TO
THE BOX AND STUBBED INTO AN ACCESSIBLE CEILING LOCATION. A
BUSHING SHALL BE PLACED ON ALL RAW ENDS OF THE CONDUITS.
C. ALL CAMERAS SHALL BE POWERED VIA POE ON THE CATEGORY 6 UTP.
THE CONTRACTOR SHALL PROVIDE ADEQUATE UPS'S FOR THE
EQUIPMENT, SUCH AS SWITCHES, CAMERAS, RECORDER - ETC
D. ALL CABLES PASSING THROUGH A PLENUM SPACE SHALL BE RATED FOR
THAT SPACE.
E. WHERE CABLES PASS THROUGH A CONDUIT SLEEVE OR THROUGH A
HARD CEILING AREA LONGER THAN 4 LINEAR FEET, A PULL STRING SHALL
BE PLACED AND SECURED FOR FUTURE CABLE PLACEMENT.
F. ALL CAMERAS SHALL BE PROGRAMMED AND LABELED PER THE EXISTING
BUILDING METHOD. THE CONTRACTOR SHALL MAKE CERTAIN THE DATE
AND TIME ARE SET CORRECTLY ON ALL CAMERAS. CONTRACTORS
SHALL USE THE NETWORK CLOCK FOR TIMEKEEPING.
G. THE CAMERA SYSTEM MUST INTERFACE TO THE ACCESS CONTROL
SYSTEM FOR RECORDING ON CARD PRESTATIONS.
H. CAMERAS SHALL BE MOUNTED AT 10' AFF AND SHALL NOT BE
OBSTRUCTED BY DOORS, FIRE SIGNALING DEVICES OR FURNISHINGS.
I. ALL EXISTING COAX - CABLE CURRENTLY SUPPORTING THE CAMERA
EQUIPMENT SHALL BE REMOVED BY THE CCTV CONTRACTOR AND
PROPERLY DISPOSED OF.
J. ALL EXISTING INTRUSION DETECTION DEVICES OR POINTS SUCH AS
MOTION SENSORS, GLASS BREAK SENSORS, ETC. SHALL BE REUSED.
HEAD END INTRUSION DETECTION PANEL(S) WILL BE REPLACED.
K. EXISTING KEYPADS TO REMAIN. SPECIFICATION SECTION 281500
"ACCESS CONTROL HARDWARE DEVICES" STATES THAT ANY CARD
READER/KEYPADS ADDED OR REPLACED MUST BE CAC-COMMON
ACCESS CARD COMPLIANT AS WELL AS HSPD-12 AND FIPS-201-2.
GENERAL NOTES
ERICKSENGOOD GOOD
1. NEW VIDEO SYSTEM - TO UTILIZE CATEGORY GRADE
CABLING.
2. EXTERIOR RATED CAMERA (REFER TO
SPECIFICATIONS).
3. EXISTING CAMERA SYSTEM HEADEND LOCATION.
4. NEW MOTION SENSOR, CONNECT TO EXISTING
SECURITY SYSTEM.
(TOP OF STAIRS)
(ON ROOF)
107 106 105 104 103 102
101b101a113 C101a
C102 115 114
C103
129c
129h 129j
129k
129i116 116a
C104
S101
C101
C
KEY PLAN
SECURITY NEW PLAN - AREA C
1/8"=1'-0"
SHEET WORK NOTES-
1F-OR-1074-4-8.0
A. ALL CAMERAS SHALL BE CONNECTED TO THE RECORDER VIA CATEGORY
6 UTP. THE CONTRACTOR SHALL INSTALL THE CABLE PER SECTION
271500 FOR HORIZONTAL CABLE.
B. EACH CAMERA SHALL BE MOUNTED TO A 4 SQUARE BOX SECURELY
ATTACHED TO WALLS/CEILINGS. A 1" CONDUIT SHALL BE CONNECTED TO
THE BOX AND STUBBED INTO AN ACCESSIBLE CEILING LOCATION. A
BUSHING SHALL BE PLACED ON ALL RAW ENDS OF THE CONDUITS.
C. ALL CAMERAS SHALL BE POWERED VIA POE ON THE CATEGORY 6 UTP.
THE CONTRACTOR SHALL PROVIDE ADEQUATE UPS'S FOR THE
EQUIPMENT, SUCH AS SWITCHES, CAMERAS, RECORDER - ETC
D. ALL CABLES PASSING THROUGH A PLENUM SPACE SHALL BE RATED FOR
THAT SPACE.
E. WHERE CABLES PASS THROUGH A CONDUIT SLEEVE OR THROUGH A
HARD CEILING AREA LONGER THAN 4 LINEAR FEET, A PULL STRING SHALL
BE PLACED AND SECURED FOR FUTURE CABLE PLACEMENT.
F. ALL CAMERAS SHALL BE PROGRAMMED AND LABELED PER THE EXISTING
BUILDING METHOD. THE CONTRACTOR SHALL MAKE CERTAIN THE DATE
AND TIME ARE SET CORRECTLY ON ALL CAMERAS. CONTRACTORS
SHALL USE THE NETWORK CLOCK FOR TIMEKEEPING.
G. THE CAMERA SYSTEM MUST INTERFACE TO THE ACCESS CONTROL
SYSTEM FOR RECORDING ON CARD PRESTATIONS.
H. CAMERAS SHALL BE MOUNTED AT 10' AFF AND SHALL NOT BE
OBSTRUCTED BY DOORS, FIRE SIGNALING DEVICES OR FURNISHINGS.
I. ALL EXISTING COAX - CABLE CURRENTLY SUPPORTING THE CAMERA
EQUIPMENT SHALL BE REMOVED BY THE CCTV CONTRACTOR AND
PROPERLY DISPOSED OF.
J. ALL EXISTING INTRUSION DETECTION DEVICES OR POINTS SUCH AS
MOTION SENSORS, GLASS BREAK SENSORS, ETC. SHALL BE REUSED.
HEAD END INTRUSION DETECTION PANEL(S) WILL BE REPLACED.
K. EXISTING KEYPADS TO REMAIN. SPECIFICATION SECTION 281500
"ACCESS CONTROL HARDWARE DEVICES" STATES THAT ANY CARD
READER/KEYPADS ADDED OR REPLACED MUST BE CAC-COMMON
ACCESS CARD COMPLIANT AS WELL AS HSPD-12 AND FIPS-201-2.
GENERAL NOTES
ERICKSENGOOD GOOD
1. NEW VIDEO SYSTEM - TO UTILIZE CATEGORY GRADE
CABLING.
2. EXTERIOR RATED CAMERA (REFER TO
SPECIFICATIONS).
3. EXISTING CAMERA SYSTEM HEADEND LOCATION.
PROVIDE 10"X10"X4"
HOFFMAN
JUNCTION BOX
MOTION
SENSOR
MRX
DOOR
POSITION
SWITCH
J-BOX
3/4" EMT C
W/PULLSTRING
LAY-IN CEILING
STUB CONDUIT OUT ABOVE
ACCESSIBLE CEILING INSTALL
INSULATED THROAT BUSHING(TYP)
1/2" EMT CONDUIT
W/PULLSTRING
ELECTRIC DOOR STRIKE
CARD READER
KEYPAD
NOTE:
1.DETAIL IS A GUIDELINE AND MAY NOT INCLUDE ALL PARTS AND CONNECTIONS REQUIRED.
SEE SPECIFICATION 281300 AND INSTALL PER MANUFACTURERS INSTRUCTIONS.
2. FIRE SEAL CONDUIT PENETRATION TO MAINTAIN RATING OF WALL WHERE APPLICABLE.
3. STUB OUT ALL CONDUITS AND INSTALL JUNCTION BOX ON SECURE SIDE OF DOOR.
FINISHED FLOOR
AO
120 VAC
POWER
SUPPLY
POWER SUPPLY (BY OTHERS)
OUTSIDE ROOM.
ABOVE ACCESSIBLE CEILING
3/4" EMT
CONDUIT
W/PULL-
STRING
DOOR
CONTROLLER
AT DATA ROOM
CR
SECURITY DOOR ROUGH-IN DETAIL (ELECTRIC STRIKE)
NO SCALE
CLEAR DOME
DOME WITH HEATER &
BLOWER, COLOR TO MATCH
MOUNTING SURFACE
PENDANT MOUNT, COLOR TO
MATCH MOUNTING SURFACE
SET SCREW PROVIDED
WITH SWM-MOUNT
SECURE WITH MOUNTING FASTENERS
OF APPROPRIATE LENGTH AND SIZE,
SUITED FOR ENVIRONMENT
MOUNTING CLEAT PROVIDED
WITH PENDANT MOUNT
ADJUSTMENT PLATE PROVIDED
WITH PENDANT MOUNT
SECURITY CAMERA WALL PENDANT MOUNT
NO SCALE
SECURE TO 5/16" STUDS
WITH SPLIT WASHERS
AND NUTS
PENDANT MOUNT,
MATCH POLE COLOR
CLEAR DOMEINTEGRATED DOME
WITH HEATER AND
BLOWER
SECURE WITH 1/4" (MINIMUM) FASTENERS
SUITED FOR ENVIRONMENT
SECURITY CAMERA WALL CORNER MOUNT
NO SCALE
SMOKED DOME
CEILING TILE CAMCLOSURE
SECURITY CAMERA CEILING RECESSED MOUNT
NO SCALE
9 99 99
TELCO ONE-LINE
NO SCALE
12OVAC 12OVAC
SECURITY CAMERA SYSTEM
POE SWITCH
C
AT
UPS
LOCAL
MONITOR
KEYBOARD
NETWORKED
VIDEO RECORDER
INTERIOR WALL MOUNT CAMERA
TYPICAL
NETWORK
LO
C
K
TRANSFORMER
EGRESS
BUTTON
EGRESS
MOTION
GLASS
BREAK
MOTION
DOOR
STATUS
CONTACT
ACCESS
CONTROL
UNIT
BATTERY
TRANSFORMER
22/6 SHIELDED CARD
KEADER/KEYPAD
ACCESS CONTROL/INTRUSION SYSTEM
C
AT
6C
AT
C
AT
CAT 618
/2
/4
/2
BATTERY
/2
/2
18/2
LOCK
POWER
SUPPLY
18/2
C
AT
CAT 6
EXTERIOR WALL MOUNT CAMERA
TYPICAL
1F-OR-1074-4-9.0ERICKSENGOOD GOOD