Exhibits A-F.pdf
PDF 588 KB Posted
- Attached to
- URGENT - SOCKET FLAT COUNTERSUNK HEAD CAP SCREWS ANGLE Federal contract opportunity
- Solicitation number
- SPMYM325Q6043
About this file
The attached file is a Contract Data Requirements List (DD Form 1423) for a federal solicitation involving socket flat countersunk head cap screws. The solicitation (SPMYM325Q6043) is a 100% small business set-aside for 32-264 titanium angle socket screws meeting specific technical specifications, including anodization per SAE AMS 2488 Rev-E Type-2. Vendors must provide comprehensive certification documentation, including non-destructive liquid penetrant and ultrasonic testing procedures and results, which must be submitted to specific Naval Shipyard codes (135T and 133.2) for review and approval.
The solicitation requires detailed data submissions across six exhibits (A-F), with each exhibit containing multiple data requirements such as certificates of compliance, chemical and mechanical certifications, and test procedures. Evaluation will be conducted using Lowest Price Technically Acceptable (LPTA) criteria, with vendors required to be registered in the System for Award Management (SAM). Quotes must be submitted by email by 4/30/2025 at 3pm EST to Jannell Moriarty, with payment terms set at Net 30 Days after material acceptance. The procurement is being processed by the Defense Logistics Agency Land and Maritime for the Portsmouth Naval Shipyard.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 25Q6043 RFQ Required.docx | DOCX document | |
| Clauses - Full Text Provisions and Clauses 241128.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT DATA REQUIREMENTS LIST
(2 DATA ITEMS)
B. EXHIBIT C. CATEGORY
A TDP ...x.. TM OTHER
E. CONTRACT/PR NO. F. CONTRACTOR
50984041 SPMYM325Q6043
245.2C-0998-25
A. CONTRACT LINE ITEM NO. 0002-0003
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD CAP
SCREW ANGLE
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
A001
CERTIFICATION OF QUALITY
CERTIFICATE OF COMPLIANCE COMPLIANCE
4. AUTHORITY(DATA Item Description Number) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-81356A SECTION C. 2 CODE245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
REQUIRED
DD With Material
ADDR DRAFT FINAL
One Time ESSE A
E
8. APP.CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT 133.2 0 1 0
N/A N/A
SUBMISSION
N/A
16 REMARKS 0 0 0
1. Technical content as described in the respective contract line item{s).
15. 0 1 0
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- TOTA
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted L under a Separate Shipment Number.
1.DATA ITEM NO. 2 TITLE of DATA ITEM 3. SUBTITLE
A002
CHEMICAL & MECHANICAL
CERTIFICATION DATA/ REPORT CERTIFICATION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678 SECTION C. 3 CODE 245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
DD
REQUIRED One Time ADDR
With Material DRAFT FINAL
A
ESSE
E
8.APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION
133.2 0 1 0 N/A N/A
N/A
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply. 0 0 0
2. Technical content as described in the respective contract line item{s).
3. This certification shall contain the actual Test results of all the NDT requested, 15. 0 1 0 also include all Chemical & Mechanical Test results required by the TOTA
Specification. L
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification requirements for Controlled Industrial Material" apply.
DD FORM 1423 PAGE 1 OF 3
B. EXHIBIT C. CATEGORY
A TDP X TM OTHER
E. CONTRACT/PR NO. F. CONTRACTOR
50984041 SPMYM325Q6043
245.2C-0998-25
A. CONTRACT LINE ITEM NO.
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
1. DATA ITEM 2. TITLE of DATA ITEM 3. SUBTITLE
NO. PROCEDURES, TEST NDT(PT)PROCEDURE APPROVAL
A003
4. AUTHORITY(DATA Item Description 5. CONTRACT REFERENCE 6. REQUIRING OFFICE Number)
SECTION C. 4 PURCHASING ACTIVITY
UDI-T-23732-B
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
REQUIRED
DD PRIOR TO ANY PT DRAFT FINAL
A
AS REQ'D
PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 135T 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply.
Non-Destructive Liquid Penetrant Inspection (PT) Procedure 15. TOTAL 0 1 0
Performance: NAVSEA T9074-AS-GIB-010/271 Rev 1 and FF-S-86H
Acceptance: FF-S-86H, and ASTM F788 (Including Supplementary
Requirement S1)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
1. DATA ITEM NO. 2. TITLE ofDATA ITEM 3. SUBTITLE
A004
NDT (UT) PROCEDURE APPROVAL
PROCEDURES TEST
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
UID-T-23732-B SECTION C. 5 PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
DD
REQUIRED AS REQ'D
PRIOR TO ANY UT DRAFT FINAL
A PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
135T 0 1 0 A N/A
16 REMARKS
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply. 0 0 0
Non-Destructive Ultrasonic Testing (UT) Procedure Performance: SAE AMS 6932 Rev C and SAE AMS 2631 G Acceptance: SAE AMS 6932 Rev C and SAE AMS 2631 G 15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
DD FORM 1423 PAGE 2 OF 3
0004-0005
B. EXHIBIT C. CATEGORY
A TDP X TM OTHER
E. CONTRACT/PR NO. F. CONTRACTOR
50984041 SPMYM325Q6043
245.2C-0998-25
A. CONTRACT LINE ITEM NO. 0006-0007
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD CAP
SCREW ANGLE
9. DATA ITEM NO. 10. TITLE ofDATA ITEM I
11. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - LIQUID PENETRANT INSPECTION
A005
12. AUTHORITY(DATA Item Description Number) 13. CONTRACT REFERENCE 14. REQUIRING OFFICE
DI-MISC-80678(DD) SECTION C. 6 PURCHASING ACTIVITY
15. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIESREQUIRED
SD WITH MATERIAL
ADDRESSEE DRAFT FINAL
One Time A
16. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 133.2 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do not apply.
15. TOTAL 0 1 0
- VENDOR'S PT INSPECTION RESULTS IA W NAVSEA TECH PUB T9074-AS-GIB-
010/271 REV-1 AND FF-S-86H, and ASTM F788 (Including Supplementary Requirement
Sl)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - ULTRASONIC
A006 INSPECTION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678(DDl SECTION C. 7
PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIES REQUIRED One Time ADDRESSEE SD With Material DRAFT FINAL
A
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
133.2 0 1 0 A N/A
16 REMARKS
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do 0 0 0 not apply --
- VENDOR'S UT INSPECTION RESULTS IA W SAE AMS 6932 Rev C and SAE AMS 2631 G.
15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shiooed prior to the receipt of acceptance
G. PREPARED BY H. DATE I. APPROVED BY 245.2 J. DATE
CONRAD GAGNE Ext: 6797 04/11/2025 4/12/2025
245.2C X
04/11/2025 Jason Laflam m e
Sign ed by: LAFLAM M E .JASO N .R .1255776556
DD FORM 1423 PAGE 3 OF 3
245.2C-0998-25 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP ...x.. TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
B. EXHIBIT
B
E. CONTRACT/PR NO.
50984042 SPMYM325Q6043
SCREW ANGLE
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
B001
CERTIFICATION OF QUALITY
CERTIFICATE OF COMPLIANCE COMPLIANCE
4. AUTHORITY(DATA Item Description Number) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-81356A SECTION C. 2 CODE245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
REQUIRED
DD With Material
ADDR DRAFT FINAL
One Time ESSE A
E
8. APP.CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT 133.2 0 1 0
N/A N/A
SUBMISSION
N/A
16 REMARKS 0 0 0
1. Technical content as described in the respective contract line item{s).
15. 0 1 0
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- TOTA
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted L under a Separate Shipment Number.
1.DATA ITEM NO. 2 TITLE of DATA ITEM 3. SUBTITLE
B002
CHEMICAL & MECHANICAL
CERTIFICATION DATA/ REPORT CERTIFICATION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678 SECTION C. 3 CODE 245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
DD
REQUIRED One Time ADDR
With Material DRAFT FINAL
A
ESSE
E
8.APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION
133.2 0 1 0 N/A N/A
N/A
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply. 0 0 0
2. Technical content as described in the respective contract line item{s).
3. This certification shall contain the actual Test results of all the NDT requested, 15. 0 1 0 also include all Chemical & Mechanical Test results required by the TOTA
Specification. L
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification requirements for Controlled Industrial Material" apply.
0009-0010
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD
B. EXHIBIT
B
E. CONTRACT/PR NO.
50984042 SPMYM325Q6043
CAP SCREW ANGLE
1. DATA ITEM 2. TITLE of DATA ITEM 3. SUBTITLE
PROCEDURES, TEST NDT(PT)PROCEDURE APPROVAL NO.
B003
4. AUTHORITY(DATA Item Description 5. CONTRACT REFERENCE 6. REQUIRING OFFICE Number)
SECTION C. 4 PURCHASING ACTIVITY
UDI-T-23732-B
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
REQUIRED
DD PRIOR TO ANY PT DRAFT FINAL
A
AS REQ'D
PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 135T 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply.
Non-Destructive Liquid Penetrant Inspection (PT) Procedure 15. TOTAL 0 1 0
Performance: NAVSEA T9074-AS-GIB-010/271 Rev 1 and FF-S-86H
Acceptance: FF-S-86H, and ASTM F788 (Including Supplementary
Requirement S1)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
1. DATA ITEM NO. 2. TITLE ofDATA ITEM 3. SUBTITLE
B004
NDT (UT) PROCEDURE APPROVAL
PROCEDURES TEST
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
UID-T-23732-B SECTION C. 5 PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
DD
REQUIRED AS REQ'D
PRIOR TO ANY UT DRAFT FINAL
A PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
135T 0 1 0 A N/A
16 REMARKS
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply. 0 0 0
Non-Destructive Ultrasonic Testing (UT) Procedure Performance: SAE AMS 6932 Rev C and SAE AMS 2631 G Acceptance: SAE AMS 6932 Rev C and SAE AMS 2631 G 15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
0011-0012
A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY
B TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
E. CONTRACT/PR NO.
50984042 SPMYM325Q6043
SCREW ANGLE
9. DATA ITEM NO. 10. TITLE ofDATA ITEM I
11. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - LIQUID PENETRANT INSPECTION
B005
12. AUTHORITY(DATA Item Description Number) 13. CONTRACT REFERENCE 14. REQUIRING OFFICE
DI-MISC-80678(DD) SECTION C. 6 PURCHASING ACTIVITY
15. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIESREQUIRED
SD WITH MATERIAL
ADDRESSEE DRAFT FINAL
One Time A
16. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 133.2 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do not apply.
15. TOTAL 0 1 0
- VENDOR'S PT INSPECTION RESULTS IA W NAVSEA TECH PUB T9074-AS-GIB-
010/271 REV-1 AND FF-S-86H, and ASTM F788 (Including Supplementary Requirement
Sl)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - ULTRASONIC
B006 INSPECTION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678(DDl SECTION C. 7
PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIES REQUIRED One Time ADDRESSEE SD With Material DRAFT FINAL
A
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
133.2 0 1 0 A N/A
16 REMARKS
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do 0 0 0 not apply --
- VENDOR'S UT INSPECTION RESULTS IA W SAE AMS 6932 Rev C and SAE AMS 2631 G.
15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shiooed prior to the receipt of acceptance
G. PREPARED BY H. DATE I. APPROVED BY 245.2 J. DATE
CONRAD GAGNE Ext: 6797 04/11/2025 4/12/2025
245.2C X
04/11/2025 Jason Laflam m e
Sign ed by: LAFLAM M E .JASO N .R .1255776556
0013-0014
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP ...x.. TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
B. EXHIBIT
C
E. CONTRACT/PR NO.
50984043 SPMYM325Q6043
SCREW ANGLE
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
C001
CERTIFICATION OF QUALITY
CERTIFICATE OF COMPLIANCE COMPLIANCE
4. AUTHORITY(DATA Item Description Number) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-81356A SECTION C. 2 CODE245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
REQUIRED
DD With Material
ADDR DRAFT FINAL
One Time ESSE A
E
8. APP.CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT 133.2 0 1 0
N/A N/A
SUBMISSION
N/A
16 REMARKS 0 0 0
1. Technical content as described in the respective contract line item{s).
15. 0 1 0
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- TOTA
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted L under a Separate Shipment Number.
1.DATA ITEM NO. 2 TITLE of DATA ITEM 3. SUBTITLE
C002
CHEMICAL & MECHANICAL
CERTIFICATION DATA/ REPORT CERTIFICATION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678 SECTION C. 3 CODE 245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
DD
REQUIRED One Time ADDR
With Material DRAFT FINAL
A
ESSE
E
8.APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION
133.2 0 1 0 N/A N/A
N/A
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply. 0 0 0
2. Technical content as described in the respective contract line item{s).
3. This certification shall contain the actual Test results of all the NDT requested, 15. 0 1 0 also include all Chemical & Mechanical Test results required by the TOTA
Specification. L
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification requirements for Controlled Industrial Material" apply.
0016-0017
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD
B. EXHIBIT
C
E. CONTRACT/PR NO.
50984043 SPMYM325Q6043
CAP SCREW ANGLE
1. DATA ITEM 2. TITLE of DATA ITEM 3. SUBTITLE
PROCEDURES, TEST NDT(PT)PROCEDURE APPROVAL NO.
C003
4. AUTHORITY(DATA Item Description 5. CONTRACT REFERENCE 6. REQUIRING OFFICE Number)
SECTION C. 4 PURCHASING ACTIVITY
UDI-T-23732-B
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
REQUIRED
DD PRIOR TO ANY PT DRAFT FINAL
A
AS REQ'D
PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 135T 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply.
Non-Destructive Liquid Penetrant Inspection (PT) Procedure 15. TOTAL 0 1 0
Performance: NAVSEA T9074-AS-GIB-010/271 Rev 1 and FF-S-86H
Acceptance: FF-S-86H, and ASTM F788 (Including Supplementary
Requirement S1)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
1. DATA ITEM NO. 2. TITLE ofDATA ITEM 3. SUBTITLE
C004
NDT (UT) PROCEDURE APPROVAL
PROCEDURES TEST
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
UID-T-23732-B SECTION C. 5 PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
DD
REQUIRED AS REQ'D
PRIOR TO ANY UT DRAFT FINAL
A PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
135T 0 1 0 A N/A
16 REMARKS
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply. 0 0 0
Non-Destructive Ultrasonic Testing (UT) Procedure Performance: SAE AMS 6932 Rev C and SAE AMS 2631 G Acceptance: SAE AMS 6932 Rev C and SAE AMS 2631 G 15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
0018-0019
A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY
C TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
E. CONTRACT/PR NO.
50984043 SPMYM325Q6043
SCREW ANGLE
9. DATA ITEM NO. 10. TITLE ofDATA ITEM I
11. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - LIQUID PENETRANT INSPECTION
C005
12. AUTHORITY(DATA Item Description Number) 13. CONTRACT REFERENCE 14. REQUIRING OFFICE
DI-MISC-80678(DD) SECTION C. 6 PURCHASING ACTIVITY
15. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIESREQUIRED
SD WITH MATERIAL
ADDRESSEE DRAFT FINAL
One Time A
16. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 133.2 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do not apply.
15. TOTAL 0 1 0
- VENDOR'S PT INSPECTION RESULTS IA W NAVSEA TECH PUB T9074-AS-GIB-
010/271 REV-1 AND FF-S-86H, and ASTM F788 (Including Supplementary Requirement
Sl)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - ULTRASONIC
C006 INSPECTION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678(DDl SECTION C. 7
PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIES REQUIRED One Time ADDRESSEE SD With Material DRAFT FINAL
A
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
133.2 0 1 0 A N/A
16 REMARKS
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do 0 0 0 not apply --
- VENDOR'S UT INSPECTION RESULTS IA W SAE AMS 6932 Rev C and SAE AMS 2631 G.
15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shiooed prior to the receipt of acceptance
G. PREPARED BY H. DATE I. APPROVED BY 245.2 J. DATE
CONRAD GAGNE Ext: 6797 04/11/2025 4/12/2025
245.2C X
04/11/2025 Jason Laflam m e
Sign ed by: LAFLAM M E .JASO N .R .1255776556
0020-0021
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP ...x.. TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
B. EXHIBIT
D
E. CONTRACT/PR NO.
50984044 SPMYM325Q6043
SCREW ANGLE
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
D001
CERTIFICATION OF QUALITY
CERTIFICATE OF COMPLIANCE COMPLIANCE
4. AUTHORITY(DATA Item Description Number) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-81356A SECTION C. 2 CODE245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
REQUIRED
DD With Material
ADDR DRAFT FINAL
One Time ESSE A
E
8. APP.CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT 133.2 0 1 0
N/A N/A
SUBMISSION
N/A
16 REMARKS 0 0 0
1. Technical content as described in the respective contract line item{s).
15. 0 1 0
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- TOTA
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted L under a Separate Shipment Number.
1.DATA ITEM NO. 2 TITLE of DATA ITEM 3. SUBTITLE
D002
CHEMICAL & MECHANICAL
CERTIFICATION DATA/ REPORT CERTIFICATION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678 SECTION C. 3 CODE 245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
DD
REQUIRED One Time ADDR
With Material DRAFT FINAL
A
ESSE
E
8.APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION
133.2 0 1 0 N/A N/A
N/A
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply. 0 0 0
2. Technical content as described in the respective contract line item{s).
3. This certification shall contain the actual Test results of all the NDT requested, 15. 0 1 0 also include all Chemical & Mechanical Test results required by the TOTA
Specification. L
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification requirements for Controlled Industrial Material" apply.
0023-0024
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD
B. EXHIBIT
D
E. CONTRACT/PR NO.
50984044 SPMYM325Q6043
CAP SCREW ANGLE
1. DATA ITEM 2. TITLE of DATA ITEM 3. SUBTITLE
PROCEDURES, TEST NDT(PT)PROCEDURE APPROVAL NO.
D003
4. AUTHORITY(DATA Item Description 5. CONTRACT REFERENCE 6. REQUIRING OFFICE Number)
SECTION C. 4 PURCHASING ACTIVITY
UDI-T-23732-B
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
REQUIRED
DD PRIOR TO ANY PT DRAFT FINAL
A
AS REQ'D
PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 135T 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply.
Non-Destructive Liquid Penetrant Inspection (PT) Procedure 15. TOTAL 0 1 0
Performance: NAVSEA T9074-AS-GIB-010/271 Rev 1 and FF-S-86H
Acceptance: FF-S-86H, and ASTM F788 (Including Supplementary
Requirement S1)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
1. DATA ITEM NO. 2. TITLE ofDATA ITEM 3. SUBTITLE
D004
NDT (UT) PROCEDURE APPROVAL
PROCEDURES TEST
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
UID-T-23732-B SECTION C. 5 PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
DD
REQUIRED AS REQ'D
PRIOR TO ANY UT DRAFT FINAL
A PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
135T 0 1 0 A N/A
16 REMARKS
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply. 0 0 0
Non-Destructive Ultrasonic Testing (UT) Procedure Performance: SAE AMS 6932 Rev C and SAE AMS 2631 G Acceptance: SAE AMS 6932 Rev C and SAE AMS 2631 G 15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
0025-0026
A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY
D TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
E. CONTRACT/PR NO.
50984044 SPMYM325Q6043
SCREW ANGLE
9. DATA ITEM NO. 10. TITLE ofDATA ITEM I
11. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - LIQUID PENETRANT INSPECTION
D005
12. AUTHORITY(DATA Item Description Number) 13. CONTRACT REFERENCE 14. REQUIRING OFFICE
DI-MISC-80678(DD) SECTION C. 6 PURCHASING ACTIVITY
15. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIESREQUIRED
SD WITH MATERIAL
ADDRESSEE DRAFT FINAL
One Time A
16. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 133.2 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do not apply.
15. TOTAL 0 1 0
- VENDOR'S PT INSPECTION RESULTS IA W NAVSEA TECH PUB T9074-AS-GIB-
010/271 REV-1 AND FF-S-86H, and ASTM F788 (Including Supplementary Requirement
Sl)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - ULTRASONIC
D006 INSPECTION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678(DDl SECTION C. 7
PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIES REQUIRED One Time ADDRESSEE SD With Material DRAFT FINAL
A
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
133.2 0 1 0 A N/A
16 REMARKS
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do 0 0 0 not apply --
- VENDOR'S UT INSPECTION RESULTS IA W SAE AMS 6932 Rev C and SAE AMS 2631 G.
15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shiooed prior to the receipt of acceptance
G. PREPARED BY H. DATE I. APPROVED BY 245.2 J. DATE
CONRAD GAGNE Ext: 6797 04/11/2025 4/12/2025
245.2C X
04/11/2025 Jason Laflam m e
Sign ed by: LAFLAM M E .JASO N .R .1255776556
0027-0028
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP ...x.. TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
B. EXHIBIT
E
E. CONTRACT/PR NO.
50984045 SPMYM325Q6043
SCREW ANGLE
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
E001
CERTIFICATION OF QUALITY
CERTIFICATE OF COMPLIANCE COMPLIANCE
4. AUTHORITY(DATA Item Description Number) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-81356A SECTION C. 2 CODE245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
REQUIRED
DD With Material
ADDR DRAFT FINAL
One Time ESSE A
E
8. APP.CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT 133.2 0 1 0
N/A N/A
SUBMISSION
N/A
16 REMARKS 0 0 0
1. Technical content as described in the respective contract line item{s).
15. 0 1 0
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- TOTA
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted L under a Separate Shipment Number.
1.DATA ITEM NO. 2 TITLE of DATA ITEM 3. SUBTITLE
E002
CHEMICAL & MECHANICAL
CERTIFICATION DATA/ REPORT CERTIFICATION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678 SECTION C. 3 CODE 245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
DD
REQUIRED One Time ADDR
With Material DRAFT FINAL
A
ESSE
E
8.APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION
133.2 0 1 0 N/A N/A
N/A
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply. 0 0 0
2. Technical content as described in the respective contract line item{s).
3. This certification shall contain the actual Test results of all the NDT requested, 15. 0 1 0 also include all Chemical & Mechanical Test results required by the TOTA
Specification. L
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification requirements for Controlled Industrial Material" apply.
0030-0031
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD
B. EXHIBIT
E
E. CONTRACT/PR NO.
50984045 SPMYM325Q6043
CAP SCREW ANGLE
1. DATA ITEM 2. TITLE of DATA ITEM 3. SUBTITLE
PROCEDURES, TEST NDT(PT)PROCEDURE APPROVAL NO.
E003
4. AUTHORITY(DATA Item Description 5. CONTRACT REFERENCE 6. REQUIRING OFFICE Number)
SECTION C. 4 PURCHASING ACTIVITY
UDI-T-23732-B
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
REQUIRED
DD PRIOR TO ANY PT DRAFT FINAL
A
AS REQ'D
PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 135T 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply.
Non-Destructive Liquid Penetrant Inspection (PT) Procedure 15. TOTAL 0 1 0
Performance: NAVSEA T9074-AS-GIB-010/271 Rev 1 and FF-S-86H
Acceptance: FF-S-86H, and ASTM F788 (Including Supplementary
Requirement S1)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
1. DATA ITEM NO. 2. TITLE ofDATA ITEM 3. SUBTITLE
E004
NDT (UT) PROCEDURE APPROVAL
PROCEDURES TEST
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
UID-T-23732-B SECTION C. 5 PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
DD
REQUIRED AS REQ'D
PRIOR TO ANY UT DRAFT FINAL
A PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
135T 0 1 0 A N/A
16 REMARKS
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply. 0 0 0
Non-Destructive Ultrasonic Testing (UT) Procedure Performance: SAE AMS 6932 Rev C and SAE AMS 2631 G Acceptance: SAE AMS 6932 Rev C and SAE AMS 2631 G 15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
0032-0033
A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY
E TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
E. CONTRACT/PR NO.
50984045 SPMYM325Q6043
SCREW ANGLE
9. DATA ITEM NO. 10. TITLE ofDATA ITEM I
11. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - LIQUID PENETRANT INSPECTION
E005
12. AUTHORITY(DATA Item Description Number) 13. CONTRACT REFERENCE 14. REQUIRING OFFICE
DI-MISC-80678(DD) SECTION C. 6 PURCHASING ACTIVITY
15. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIESREQUIRED
SD WITH MATERIAL
ADDRESSEE DRAFT FINAL
One Time A
16. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 133.2 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do not apply.
15. TOTAL 0 1 0
- VENDOR'S PT INSPECTION RESULTS IA W NAVSEA TECH PUB T9074-AS-GIB-
010/271 REV-1 AND FF-S-86H, and ASTM F788 (Including Supplementary Requirement
Sl)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - ULTRASONIC
E006 INSPECTION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678(DDl SECTION C. 7
PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIES REQUIRED One Time ADDRESSEE SD With Material DRAFT FINAL
A
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
133.2 0 1 0 A N/A
16 REMARKS
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do 0 0 0 not apply --
- VENDOR'S UT INSPECTION RESULTS IA W SAE AMS 6932 Rev C and SAE AMS 2631 G.
15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shiooed prior to the receipt of acceptance
G. PREPARED BY H. DATE I. APPROVED BY 245.2 J. DATE
CONRAD GAGNE Ext: 6797 04/11/2025 4/12/2025
245.2C X
04/11/2025 Jason Laflam m e
Sign ed by: LAFLAM M E .JASO N .R .1255776556
0034-0035
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP ...x.. TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
B. EXHIBIT
F
E. CONTRACT/PR NO.
50984046 SPMYM325Q6043
SCREW ANGLE
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
F001
CERTIFICATION OF QUALITY
CERTIFICATE OF COMPLIANCE COMPLIANCE
4. AUTHORITY(DATA Item Description Number) 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-81356A SECTION C. 2 CODE245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
REQUIRED
DD With Material
ADDR DRAFT FINAL
One Time ESSE A
E
8. APP.CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT 133.2 0 1 0
N/A N/A
SUBMISSION
N/A
16 REMARKS 0 0 0
1. Technical content as described in the respective contract line item{s).
15. 0 1 0
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- TOTA
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted L under a Separate Shipment Number.
1.DATA ITEM NO. 2 TITLE of DATA ITEM 3. SUBTITLE
F002
CHEMICAL & MECHANICAL
CERTIFICATION DATA/ REPORT CERTIFICATION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678 SECTION C. 3 CODE 245
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. b. COPIES
DD
REQUIRED One Time ADDR
With Material DRAFT FINAL
A
ESSE
E
8.APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION
133.2 0 1 0 N/A N/A
N/A
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply. 0 0 0
2. Technical content as described in the respective contract line item{s).
3. This certification shall contain the actual Test results of all the NDT requested, 15. 0 1 0 also include all Chemical & Mechanical Test results required by the TOTA
Specification. L
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification requirements for Controlled Industrial Material" apply.
0037-0038
A. CONTRACT LINE ITEM NO. C. CATEGORY
TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD
B. EXHIBIT
F
E. CONTRACT/PR NO.
50984046 SPMYM325Q6043
CAP SCREW ANGLE
1. DATA ITEM 2. TITLE of DATA ITEM 3. SUBTITLE
PROCEDURES, TEST NDT(PT)PROCEDURE APPROVAL NO.
F003
4. AUTHORITY(DATA Item Description 5. CONTRACT REFERENCE 6. REQUIRING OFFICE Number)
SECTION C. 4 PURCHASING ACTIVITY
UDI-T-23732-B
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
REQUIRED
DD PRIOR TO ANY PT DRAFT FINAL
A
AS REQ'D
PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 135T 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply.
Non-Destructive Liquid Penetrant Inspection (PT) Procedure 15. TOTAL 0 1 0
Performance: NAVSEA T9074-AS-GIB-010/271 Rev 1 and FF-S-86H
Acceptance: FF-S-86H, and ASTM F788 (Including Supplementary
Requirement S1)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
1. DATA ITEM NO. 2. TITLE ofDATA ITEM 3. SUBTITLE
F004
NDT (UT) PROCEDURE APPROVAL
PROCEDURES TEST
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
UID-T-23732-B SECTION C. 5 PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION
STATEMENT SUBMISSION
a. ADDRESSEE b. COPIES
DD
REQUIRED AS REQ'D
PRIOR TO ANY UT DRAFT FINAL
A PERFORMED
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
135T 0 1 0 A N/A
16 REMARKS
Block 4- Paragraph 10.1 ofUDI-T-23732 B does not apply. 0 0 0
Non-Destructive Ultrasonic Testing (UT) Procedure Performance: SAE AMS 6932 Rev C and SAE AMS 2631 G Acceptance: SAE AMS 6932 Rev C and SAE AMS 2631 G 15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
0039-0040
A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY
F TDP X TM OTHER
D. SYSTEM/ITEM F. CONTRACTOR
SOCKET FLAT COUNTERSUNK HEAD CAP
E. CONTRACT/PR NO.
50984046 SPMYM325Q6043
SCREW ANGLE
9. DATA ITEM NO. 10. TITLE ofDATA ITEM I
11. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - LIQUID PENETRANT INSPECTION
F005
12. AUTHORITY(DATA Item Description Number) 13. CONTRACT REFERENCE 14. REQUIRING OFFICE
DI-MISC-80678(DD) SECTION C. 6 PURCHASING ACTIVITY
15. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIESREQUIRED
SD WITH MATERIAL
ADDRESSEE DRAFT FINAL
One Time A
16. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
SUBMISSION 133.2 0 1 0
A N/A N/A
16 REMARKS 0 0 0
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do not apply.
15. TOTAL 0 1 0
- VENDOR'S PT INSPECTION RESULTS IA W NAVSEA TECH PUB T9074-AS-GIB-
010/271 REV-1 AND FF-S-86H, and ASTM F788 (Including Supplementary Requirement
Sl)
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance
1. DATA ITEM NO. 2. TITLE of DATA ITEM 3. SUBTITLE
CERTIFICATION/DATA REPORT TEST CERTIFICATION - ULTRASONIC
F006 INSPECTION
4. AUTHORITY 5. CONTRACT REFERENCE 6. REQUIRING OFFICE
DI-MISC-80678(DDl SECTION C. 7
PURCHASING ACTIVITY
7. DD 250 REQ 9. DIST 10. FREQUENCY 12. DATE OF 1st 14. DISTRIBUTION STATEMENT SUBMISSION a. b. COPIES REQUIRED One Time ADDRESSEE SD With Material DRAFT FINAL
A
8. APP. CODE 11. AS OF DATE 13. DATE OF REG REPRO
SUBSEQUENT
N/A
SUBMISSION
133.2 0 1 0 A N/A
16 REMARKS
Block 4-Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 ofDI-MISC-80678(DD) do 0 0 0 not apply --
- VENDOR'S UT INSPECTION RESULTS IA W SAE AMS 6932 Rev C and SAE AMS 2631 G.
15. TOTAL 0 1 0
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-
36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shiooed prior to the receipt of acceptance
G. PREPARED BY H. DATE I. APPROVED BY 245.2 J. DATE
CONRAD GAGNE Ext: 6797 04/11/2025 4/12/2025
245.2C X
04/11/2025 Jason Laflam m e
Sign ed by: LAFLAM M E .JASO N .R .1255776556
0041-0042
| Exhibit A |
| Exhibit B |
| Exhibit C |
| Exhibit D |
| Exhibit E |
| Exhibit F |
File details come from the government source that posted it. Updated .