Encl. 3 100 percent electrical drawings.pdf
PDF 4 MB Posted
- Attached to
- Climate Controlled Lockers Federal contract opportunity
- Solicitation number
- 12905B20Q1009692
About this file
This is a solicitation for climate-controlled modular insect lockers and plant growth lockers. The USDA Agricultural Research Service Pacific Basin Agricultural Research Center is seeking quotes by September 24, 2020 for the supply, delivery and installation of various climate-controlled modular units. The required products include twelve 10'x10' insect lockers, six 10'x10' lockers with windows, and two 10'x15' plant growth lockers. Optional setup and installation services are also requested. Technical specifications outline minimum requirements for lighting, electrical outlets, construction materials and anchoring. Delivery is to be made by February 26, 2021 to the research center location in Hilo, Hawaii. The government will select the lowest priced technically acceptable quote meeting delivery date requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Encl.2c 3D drawing insectary-equipment-2020-05-27.png | PNG image | |
| Encl.2b 3D drawing insectary-equipment-2020-05-27.png | PNG image | |
| Encl.1 Price Breakdown Template.xlsx | XLSX spreadsheet | |
| Encl.2a 3D drawing insectary-equipment-2020-05-27.png | PNG image |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A AMPERE
AC ALTERNATING CURRENT
AFF ABOVE FINISHED FLOOR
AWG AMERICAN WIRE GAUGE
BLDG BUILDING
BRKR BREAKER
C CONDUIT
CAB CABINET
CAT CATEGORY
CB CIRCUIT BREAKER
CKT CIRCUIT
COMM COMMUNICATIONS
CT CATEGORY
CU COPPER
D DEEP (DIM)
DISC DISCONNECT
DET DETAIL
DWG DRAWING
EA EACH
(E) EXISTING
ELEC ELECTRICAL
EWH ELECTRIC WATER HEATER
FA FIRE ALARM
FAA FIRE ALARM ANNUNCIATOR
FACP FIRE ALARM CONTROL PANEL
FDR FEEDER
FIXT FIXTURE
FLEX FLEXIBLE
FLA FULL LOAD AMPS
FLR FLOOR
FT FEET; FOOT
FU FUSE
FUT FUTURE
G; GND; GRND GROUND
GALV GALVANIZED
GFI GROUND FAULT INTERRUPTER
GFCI GROUND-FAULT CIRCUIT
INTERRUPTER
GRS GALVANIZED RIGID STEEL
H HIGH (DIM)
HDPE HIGH DENSITY POLY ETHYLENE
HH HANDHOLE
HP HORSEPOWER
HZ HERTZ (CYCLES PER SEC)
IC INTERRUPTING CAPACITY
ID INSIDE DIMENSION
IMH INTERMEDIATE MANHOLE
IN INCH
JB; J-BOX JUNCTION BOX
KAIC THOUSANDS AMPS
INTERRUPTING CAPACITY
KCMIL THOUSAND CIRCULAR MILS
KVA KILOVOLT-AMPERE
KW KILOWATT(S)
KWH KILOWATT HOUR
LP LIGHT POLE
LT LIGHT
LTG LIGHTING
LTS LIGHTS
M METER
MAX MAXIMUM
MB MAIN BREAKER
MCA MINIMUM CIRCUIT AMPACITY
MCM THOUSANDS OF CIRCULAR MILS
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MLO MAIN LUG ONLY
MNS MASS NOTIFICATION SYSTEM
MTD MOUNTED
MTR MOTOR
(N) NEW
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NECA NATIONAL ELECTRICAL
CONTRACTOR ASSOCIATION
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NEUT NEUTRAL
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER; NORMALLY OPEN
NTS NOT TO SCALE
PF POWER FACTOR
PFB PROVISIONS FOR FUTURE
BREAKER
PH; Ø PHASE
PNL PANEL
PVC POLYVINYL CHLORIDE CONDUIT
RECPT; RECP;
RCPT RECEPTACLE
RMS ROOT MEAN SQUARE
SCH SCHEDULE
SECT SECTION
SHLD SHIELDED
SM SINGLE MODE
SN SOLID NEUTRAL
SP SUMP PUMP
SPEC SPECIFICATIONS
SPD SURGE PROTECTION DEVICE
SQ SQUARE
STBY STANDBY
STD STANDARD
STL STEEL
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TB TERMINAL BLOCK
TEL TELEPHONE
TR TRANSFORMER
TWPR TWISTED PAIR
TYP TYPICAL
UGC UNDERGROUND
COMMUNICATIONS
UG/T UNDERGROUND TELEPHONE
CABLE
V VOLT
W WATTS; WIRE
WHM WATT HOUR METER
WP WEATHERPROOF
XFMR TRANSFORMER
Z IMPEDANCE
ABBREVIATIONS
ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION
ELECTRICAL SYMBOL LIST (NOT ALL MAY BE USED)
RACEWAYS & CONDUCTORS (INSTALL PER NEC 210.4)
REMOVAL WORK
EXISTING WORK
RACEWAY AND CONDUCTORS - EXPOSED
RACEWAY AND CONDUCTORS - CONCEALED
RACEWAY AND CONDUCTORS - BELOW FLOOR OR GRADE
FLEXIBLE RACEWAY AND CONDUCTORS
HOMERUN TO PANEL AND CIRCUIT.
NUMBER OF ARROWS EQUALS NUMBER OF CIRCUITS.
#12 CONDUCTOR UNLESS OTHERWISE NOTED.
HOMERUN TO PANEL "A". CIRCUIT 1
POWER
PANELBOARD
DUPLEX RECEPTACLE, 20 AMP, 125 VOLT, 3 WIRE, +18" AFF OR AS NOTED
SUBSCRIPT INDICATES TYPE:
G - GFCI
WP - WEATHERPROOF
DOUBLE DUPLEX RECEPTACLE, 20 AMP, 125 VOLT, 3 WIRE, +18" AFF OR
AS NOTED
DUPLEX RECEPTACLE, 20 AMP, 125 VOLT, 3 WIRE, CEILING MOUNTED
DOUBLE DUPLEX RECEPTACLE, 20 AMP, 125 VOLT, 3 WIRE, CEILING
MOUNTED
JUNCTION BOX, 4-11/16" SQ. X 2-1/8"D, CEILING MOUNTED
JUNCTION BOX, 4-11/16" SQ X 2-1/8"D, WALL MOUNTED
EQUIPMENT CONNECTION
MOTOR CONNECTION
EQUIPMENT MOTOR SWITCH, FURNISHED BY MECHANICAL, INSTALLED BY
ELECTRICAL
NON-FUSED DISCONNECT SWITCH, HEAVY DUTY TYPE HORSEPOWER
RATED
TRANSFORMER
HANDHOLE
MANHOLE
FUSED DISCONNECT SWITCH, HEAVY DUTY TYPE HORSEPOWER RATED.
PROVIDE FUSES PER EQUIPMENT NAMEPLATE
ONE-LINE DIAGRAM
GROUND CONNECTION
TRANSFORMER
CIRCUIT BREAKER NUMBER INDICATES TRIP SETTING AND NUMBER OF
POLES
CL - INDICATES CURRENT LIMITING
ST - INDICATES SHUNT TRIP
A:1
J
J
E
M
T
LIGHTING
WALL SWITCH - +42" AFF
LUMINAIRES
LUMINAIRE TYPE IDENTIFICATION TAG, SUBSCRIPT INDICIATES:
PANEL "A", CIRCUIT NUMBER "1" AND SWITCH "a"
WALL MOUNTED FIXTURE
CEILING MOUNT EXIT SIGN
WALL MOUNTED EXIT SIGN
ARROW INDICATES DIRECTION OF EGRESS
EMERGENCY LIGHT WITH BATTERY BACKUP, MOUNT +96" AFF
LED LIGHT FIXTURE, PENDANT MOUNTED
LED LIGHT FIXTURE WITH BATTERY BACK-UP, PENDANT MOUNTED
XXX
A:1a
ELECTRICAL NOTES
1. INSTALLATION SHALL COMPLY WITH THE 2017 NATIONAL ELECTRICAL CODE, NFPA 72, LOCAL
AMENDMENTS, AND NECA STANDARDS OF INSTALLATION.
2. CUT AND PATCH THE EXISTING CEILING AND WALLS AS REQUIRED TO INSTALL NEW BRANCH
CIRCUITS. ANY PATCHES SHALL BE FINISHED TO MATCH THE EXISTING ADJACENT SURFACES.
REPLACE ANY DAMAGED CEILING TILES AS REQUIRED.
3. ALL CONDUCTORS INSTALLED IN EXTERIOR SPACES SHALL BE XHHW, INTERIOR WIRING MAY BE
THHW/THHN.
4. CONDUCTORS SHALL BE #12 AWG COPPER MINIMUM OR AS INDICATED ON THE EQUIPMENT
SCHEDULE. HOME RUN CONDUCTORS SHALL BE #10 AWG COPPER MINIMUM OR AS REQUIRED BY
NEC. MINIMUM SIZE FOR 20A BRANCH CIRCUIT MEASURED FROM THE PANELBOARD TO THE
FURTHEST DEVICE ON THE CIRCUIT UNLESS NOTED ON DRAWINGS:
A. 10 AWG CONDUCTORS FOR 120V BRANCH CIRCUITS GREATER THAN 75'.
B. 8 AWG CONDUCTORS FOR 120V BRANCH CIRCUITS GREATER THAN 175'.
TRANSITION TO #12 AWG WITHIN 15' OF DEVICE IF SMALL CONDUCTOR IS REQUIRED FOR DEVICE
TERMINATION.
5. SURFACE MOUNT CONDUIT IS NOT ALLOWED UNLESS OTHERWISE NOTED ON DRAWINGS.
6. CONTRACTOR SHALL PROVIDE AND INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL
NEW CONDUITS.
7. EXISTING EQUIPMENT INFORMATION SHOWN ON THESE DRAWINGS SHOULD BE FIELD VERIFIED.
CONFIRM EQUIPMENT LOCATIONS WITH OWNER AND ADJUST AS REQUIRED.
8. ALL CONDUCTOR SIZES SHOWN ARE BASED ON COPPER.
9. MAINTAIN MINIMUM 6" CLEARANCE BETWEEN CONDUIT AND PIPING. MAINTAIN 12" CLEARANCE
BETWEEN CONDUIT AND HEAT SOURCES SUCH AS FLUES, HEATING PIPES, AND HEATING
APPLIANCES.
10. PROVIDE TYPED, UPDATED PANEL SCHEDULES FOR NEW PANELS AND PANELS WITH CIRCUIT
MODIFICATIONS FROM THIS PROJECT.
11. VERIFY CEILING TYPES THROUGHOUT; PROVIDE ALL MOUNTING ACCESSORIES, TRIM, FLANGES, OUTLET BOXES, ETC. FOR A COMPLETE AND FINISHED INSTALLATION.
12. ALL EQUIPMENT AND MATERIALS ARE UL LISTED WHERE LISTING IS AVAILABLE FOR THAT TYPE OF
EQUIPMENT OR CONFORM TO ANSI OR NEMA STANDARDS.
13. WORKMANSHIP SHALL CONFORM TO CONSTRUCTION PRACTICES RECOMMENDED BY THE
AMERICAN ELECTRICIANS HANDBOOK BY CROFT (LATEST EDITION) AND WILL BE SUBJECTED TO
THE APPROVAL OF THE AGENCY THAT HAS JURISDICTION AND THE ENGINEER OF RECORD.
14. ALL METALLIC ENCLOSURES, RACEWAYS AND ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN
ACCORDANCE WITH REQUIREMENTS OF NEC ARTICLE 250, WITH GROUND WIRE IN EVERY
RACEWAY. RACEWAY SHALL BE SIZED IN ACCORDANCE WITH NEC TABLE 250-122.
15. TEST COMPLETED INSTALLATION AND CORRECT ALL DEFICIENCIES FOUND IN THE SYSTEM OR
INSTALLATION.
16. ALL EXISTING CIRCUITS AFFECTED DURING ELECTRICAL INSTALLATION SHALL BE RESTORED TO
THEIR ORIGINAL OPERATING CONDITION.
17. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO VERIFY THE LOCATION OF EXISTING UTILITIES PRIOR TO DEMOLITION, DIGGING, TRENCHING, OR SIMILAR OPERATIONS. COORDINATE WITH THE
CONSTRUCTION MANAGER OR OWNERS REPRESENTATIVE TO REVIEW EACH WORK AREA PRIOR
TO BEGINNING WORK.
18. ALL EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE FROM THE BEST AVAILABLE AS-BUILT
DRAWINGS AND LIMITED SITE-SURVEY. CONTRACTOR SHALL FIELD VERIFY THE ACTUAL
CONDITION BEFORE CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE ENGINEER.
19. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL RACEWAY AND
CONNECTIONS BETWEEN RESPECTIVE DEVICES, FIXTURES, AND EQUIPMENT. CONTRACTOR TO
DETERMINE EXACT ROUTING OF RACEWAY CONNECTIONS BETWEEN RESPECTIVE DEVICES,
FIXTURES, AND EQUIPMENT. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR EXACT
LOCATIONS.
20. PROVIDE CIRCUIT IDENTIFICATION LABEL ON DEVICES, LIGHT SWITCHES, AND EQUIPMENT.
21. PROVIDE SEPARATE NEUTRAL FOR ALL 120VAC BRANCH CIRCUITS.
F
ENERGY CODE COMPLIANCE
TO THE BEST OF MY KNOWLEDGE, THIS PROJECT'S DESIGN SUBSTANTIALLY CONFORMS TO THE
STATE OF HAWAII ADMINISTRATIVE RULES TITLE 3 CHAPTER 3-181.1, "STATE ENERGY CONSERVATION CODE" (IECC 2015 AS AMENDED), FOR ELECTRICAL AND LIGHTING SYSTEMS (SECTIONS C405 AND C408).
COMPLIANCE METHOD
2015 IECC AS AMENDED. MANDATORY & PRESCRIPTIVE
2015 IECC AS AMENDED. MANDATORY & TOTAL BUILDING PERFORMANCE
ASHRAE STANDARD 90.1-2013. MANDATORY & PRESCRIPTIVE
ASHRAE STANDARD 90.1-2013. MANDATORY & TOTAL BUILDING PERFORMANCE
INFORMATION IN CONSTRUCTION DOCUMENTS
INTERIOR LIGHTING YES N/A
OCCUPANT SENSOR CONTROLS. C405.2.1
TIME SWITCH CONTROLS. C405.2.2
DAYLIGHT RESPONSIVE CONTROLS. C405.2.3
DAYLIGHT ZONES ON PLANS. C405.2.3.2 & C405.2.3.3
GUEST ROOM CONTROLS. C405.2.4
INTERIOR LIGHTING FIXTURE SCHEDULE
INPUT POWER FOR INTERIOR LIGHTING FIXTURES. C405.4.1
INTERIOR LIGHTING FIXTURE LOCATIONS
LIGHTING CONTROL FUNCTIONAL PERFORMANCE TESTING REQUIREMENT. C408.3
EXTERIOR LIGHTING
EXTERIOR LIGHTING CONTROLS. C405.2.5
EXTERIOR LIGHTING FIXTURE SCHEDULE
INPUT POWER FOR EXTERIOR LIGHTING FIXTURES
EXTERIOR LIGHTING FIXTURE LOCATIONS
ELECTRICAL
ELECTRICAL TRANSFORMER EFFICIENCY. C405.7
TENANT SUBMETERING. C405.10
NOTES
SIGNATURE:
DATE: 8/14/2020
NAME: JEREMY B. DOW, P.E.
TITLE: ELECTRICAL MANAGER
LICENSE NO.: 15212-E
COUNTY OF HAWAI'I
HAWAI'I COUNTY CODE - CHAPTER 5 - BUILDING
BUILDING ENERGY EFFICIENCY STANDARDS
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720AUGUST 14, 2020
DL
E-001
JH
JBD
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
AutoCAD SHX Text
ELECTRICAL NOTES, ABBREVIATIONS, SYMBOLS
MISCELLANEOUS DETAILS:
TEST: OPERATE THE INSTALLATION AND RUN TESTS TO DEMONSTRATE ITS OPERATION AND
COMPLIANCE WITH THE SPECIFICATIONS. TEST ALL WIRING AND DEVICES TO INSURE PROPER
OPERATION ACCORDING TO FUNCTIONS SPECIFIED HEREIN, ON THE DRAWINGS AND IN OTHER
SECTIONS OF THESE SPECIFICATIONS.
2. GENERAL SPECIFICATIONS:
3.
DISCONNECT SWITCH: HEAVY DUTY NON-FUSIBLE SAFETY, SHALL BE HORSEPOWER RATED
WHEN OPERATED AND SPRING LOADED. ENCLOSURES TO HAVE PROVISION FOR LOCKING.
A.
SCOPE:1.
PROVIDE A COMPLETE AND OPERATING ELECTRICAL SYSTEM. "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". CONNECT TO ELECTRICAL SYSTEM ALL FIXTURES AND EQUIPMENT INCLUDING ANY
FURNISHED BY OWNER OR UNDER ANOTHER SECTION OF THESE SPECIFICATIONS.
IT IS THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE A COMPLETE INSTALLATION.
SHOULD THERE BE OMISSIONS OR DISCREPANCIES IN THE PLANS AND SPECIFICATIONS, THE
CONTRACTOR SHALL CALL THE ATTENTION OF THE ENGINEER TO SUCH OMISSIONS AND
DISCREPANCIES IN ADVANCE OF THE DATE OF BID OPENING SO THAT THE NECESSARY
CORRECTIONS CAN BE MADE. OTHERWISE THE CONTRACTOR SHALL FURNISH AND INSTALL THE
OMISSIONS OR DISCREPANCIES AS IF THE SAME WERE SPECIFIED AND PROVIDED FOR.
BEFORE BIDDING ON THIS WORK, CAREFULLY EXAMINE EACH OF THE DRAWINGS AND THE SITE.
BY SUBMITTING A PROPOSAL OF THE WORK INCLUDED IN THIS CONTRACT, THE CONTRACTOR
SHALL BE DEEMED TO HAVE MADE SUCH EXAMINATION AND TO BE FAMILIAR WITH AND ACCEPT
ALL CONDITIONS OF THE JOB SITE.
CODES AND PERMITS: COMPLY WITH THE REQUIREMENTS OF THE 2017 EDITION OF THE
NATIONAL ELECTRICAL CODE AND ALL ORDINANCES, RULES AND POLICIES OF THE STATE,
COUNTY IN WHICH THE WORK IS TO BE PERFORMED. OBTAIN AND PAY FOR FEES, PERMITS,
LICENSES AND INSPECTIONS REQUIRED FOR THIS WORK.
CONTRACT DRAWINGS: CIRCUIT DIAGRAMS ARE DIAGRAMMATIC SHOWING LOCATION OF
OUTLETS, CONDUITS, AND EQUIPMENT.
SUBMITTALS: SUBMIT FOR REVIEW SIX COPIES OF MANUFACTURER'S LITERATURE FOR LIGHT
FIXTURES, PANELBOARDS, TRANSFORMERS, DISCONNECT SWITCHES, HANDHOLES AND
JUNCTION BOXES.
RECORD DRAWINGS: MAINTAIN AT PROJECT SITE A COPY OF DRAWINGS TO RECORD DAILY, ANY ADDITIONS OR CHANGES. AFTER FINAL INSPECTION A COPY OF THE "AS-BUILT" DRAWINGS SHALL
BE FURNISHED TO THE ENGINEER.
B.
C.
D.
E.
F.
PRODUCTS: MATERIALS AND EQUIPMENT SHALL BE NEW, AND EQUIPMENT SATISFYING THE
REQUIREMENTS OF NEC ARTICLES 90-6 AND 110-3 SHALL BE LISTED OR LABELED BY A
NATIONALLY RECOGNIZED ELECTRICAL TESTING LABORATORY.
CONDUCTORS: THE MINIMUM SIZE OF WIRE FOR POWER AND LIGHTING WILL BE NO. 12 AWG. ALL
WIRING SHALL BE COPPER. UNLESS OTHERWISE SPECIFIED, ALL 600-VOLT WIRE AND CABLE
SHALL BE SINGLE CONDUCTOR SUITABLE FOR USE IN WET OR DRY LOCATIONS AND SHALL HAVE
INSULATION WHICH IS MOISTURE AND HEAT RESISTANT.
RIGID STEEL CONDUIT: RIGID STEEL CONDUIT SHALL BE ZINC-COATED, 3/4" MINIMUM DIAMETER
EXCEPT AS NOTED.
LIQUID-TIGHT FLEXIBLE METAL CONDUIT: FLEXIBLE METALLIC CONDUIT SHALL BE GALVANIZED
STEEL WITH PVC JACKET, LIQUID-TIGHT, SUITABLE FOR WET LOCATIONS.
OUTLET AND SMALL JUNCTION BOXES: PRESSED, ZINC- COATED STEEL, MINIMUM NOMINAL SIZE 4", MINIMUM DEPTH 1-1/2", WITH RAISED RING FOR DEVICES SET FLUSH IN COVER DRYWALL OR
CONCRETE MASONRY UNITS.
CIRCUIT BREAKERS: INDIVIDUAL BREAKERS SHALL BE MOLDED PLASTIC CASE, WITH TOGGLE
OPERATED MECHANISM THERMAL-MAGNETIC OVERLOAD TRIPS. INTERCHANGEABLE TRIP SHALL
BE PROVIDED WHEN AVAILABLE. TOGGLE POSITIONS "ON", "TRIPPED" AND "OFF", ENGRAVED ON
BODY OF TOGGLE.
A.
B.
D.
G.
H.
F.
CUT, CORE AND PATCH AS REQUIRED TO INSTALL ELECTRICAL SYSTEM. REPAIR ANY SURFACE
DAMAGED OR MARRED BY NOTCHING, CORING OR ANY OTHER PROCESS NECESSARY FOR
INSTALLATION OF ELECTRICAL WORK. CUTTING, REPAIRS AND REFINISHING SHALL BE SUBJECT
TO THE APPROVAL OF THE ENGINEER. NEED FOR REMEDIAL WORK DETERMINED BY THE
ENGINEER AS ATTRIBUTABLE TO POOR COORDINATION AND WORKMANSHIP SHALL BE CAUSE
FOR RECONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
ATTACH ELECTRICAL EQUIPMENT TO WOOD WITH NON-FERROUS WOOD SCREWS AND TO
CONCRETE USING EXPANSION ANCHORS. POWDER-CHARGE-DRIVEN STUDS AND ANCHORS
SHALL BE PERMITTED ONLY WITH PRIOR APPROVAL FROM THE ENGINEER.
WIPE CLEAN ALL EXPOSED RACEWAYS AND ENCLOSURES WITH RAGS AND SOLVENT, RACEWAYS
AND ENCLOSURES SHALL BE PRIME-PAINTED AND FINISHED TO BLEND INTO BACKGROUND. (DO
NOT PAINT NAMEPLATES).
ELECTRICAL CONTRACTOR SHALL VERIFY SIZES OF SWITCHES, CONTROLLERS, AND WIRING WITH
MECHANICAL EQUIPMENT TO BE FURNISHED. ADJUST SIZES OF SWITCHES, CONTROLLERS, AND
WIRING AS REQUIRED TO MEET MOTOR/EQUIPMENT REQUIREMENTS.
UPDATE EXISTING PANEL CIRCUIT DIRECTORIES. VERIFY ROOM AND USE DESIGNATIONS.
GROUNDING: SHALL BE INSTALLED AS SHOWN ON THE DRAWINGS AND IN CONFORMANCE WITH
NEC REQUIREMENTS.
WARRANTY:
ALL WORK IN THIS SECTION SHALL BE UNDER WARRANTY FOR A PERIOD OF ONE YEAR FROM THE
DATE OF ACCEPTANCE OF THE WORK AS A WHOLE BY THE ENGINEER. SHOULD ANY EQUIPMENT
OR MATERIAL FAIL WITHIN THIS PERIOD, THE CONTRACTOR SHALL REPLACE OR REPAIR THAT
ITEM AT NO COST FOR MATERIAL AND/OR SERVICES IF SUCH IS DUE TO FAULTY WORKMANSHIP
OR QUALITY OF MATERIAL FURNISHED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE TO ANY PART OF THE PREMISES
CAUSED BY FAILURE IN THE EQUIPMENT FURNISHED UNDER THIS AS A WHOLE.
D.
A.
B.
5.
6.
(1)
(2)
(3)
(4)
(5)
(6)
ELECTRICAL SPECIFICATIONS:
C. ELECTRICAL METALLIC TUBING (EMT): ELECTRICAL METALLIC TUBING SHALL BE GALVANIZED
ROUND BORE, 3/4" MINIMUM DIAMETER EXCEPT AS NOTED. FOR INDOOR USE ONLY WHERE
NOT SUBJECT TO DAMAGE AND WHERE INSTALLED NOT LESS THAN 8 FEET ABOVE FINISHED
FLOOR.
CONDUCTORS:
A.
(1)
4. INSTALLATION REQUIREMENTS: PROGRAM THE WORK AND COORDINATE WITH OTHER FACETS OF
THIS PROJECT. CONSTRUCTION SHALL CONFORM TO ACCEPTED INDUSTRY PRACTICES AND TO
THE RECOMMENDATIONS OF THE AMERICAN ELECTRICIANS HANDBOOK BY CROFT (LATEST
EDITION), EDISON ELECTRIC INSTITUTE, 2017 NATIONAL ELECTRICAL CODE AND APPLICABLE
INSTRUCTIONS OF MANUFACTURERS OF EQUIPMENT AND MATERIALS SUPPLIED FOR THIS
PROJECT.
CONDUIT:
CONDUIT SHALL BE CUT SQUARE AND INNER EDGES REAMED. BUTT TOGETHER EVENLY IN
COUPLINGS.
USE OF RUNNING THREADS ARE NOT PERMITTED. WHERE CONDUITS CANNOT BE JOINED BY
STANDARD THREADED COUPLINGS, APPROVED WATER-TIGHT CONDUIT UNIONS SHALL BE USED.
CAP CONDUIT DURING CONSTRUCTION WITH PLASTIC, OR METAL-CAPPED, BUSHINGS TO
PREVENT ENTRANCE OF DIRT OR MOISTURE. SWAB ALL CONDUITS AND DRY BEFORE INSTALLING
WIRES.
BOXES AND ENCLOSURES: USE GANG BOXES WHENEVER 2 OR MORE DEVICES ARE INSTALLED
AT ONE LOCATION.
FORM NEATLY IN ENCLOSURES FOR MINIMUM OF CROSSOVERS.
CONDUCTORS, #10 AND SMALLER, SHALL BE TWISTED AND MADE SECURE WITH APPROVED
WIRENUT. CONDUCTORS, #8 AND LARGER, SHALL BE SPLICED WITH HIGH-COMPRESSION COPPER
SLEEVE CONNECTORS.
ALL SPLICES SHALL BE REINSULATED AND MADE WATERPROOF. REMOVE ALL SHARP POINTS
THAT CAN PIERCE THE TAPE. USE MINNESOTA MINING AND MANUFACTURING CO., "SCOTCH" #33
TAPE, BISHOP, PLYMOUTH, OR APPROVED EQUAL.
(2)
(3)
B.
C.
(3)
(2)
(1)
I. PANELBOARDS: RATING AS INDICATED IN THE DRAWINGS. PROVIDE COPPER BUSSING, BOLT-ON CIRCUIT BREAKERS, PROVIDE WITH NEATLY TYPED CIRCUIT DIRECTORY. PROVIDE WITH DOOR-IN-DOOR TRIM WITH
PIANO HINGE COVER.
RIGID NON-METALLIC CONDUIT: PVC SCHEDULE 40 PER UL 651 AND NEMA TC-2. ROUND BORE, 3/4"
MINIMUM DIAMETER.
E.
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720AUGUST 14, 2020
DL
E-002
JH
JBD
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
ELECTRICAL SPECIFICATIONS
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
SD
S
D
S
D
S
D
SD
SD
SD
S
D
S
D
S
D
SD
SD
S
D
S
D
S
D
SD
SD
S
D
S
D
S
D
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSANSAN
SANSANSAN
SANSANSANSAN
SAN
S A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N
S A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N
S A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N
S A
N S
A N
S A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
S
A
N
SDSD
SDSDSDSDSDSDSDSDSDSDSDSDSDSDSD
SDSDSDSDSDSDSDSDSDSDSDSD
SDSDSDSDSDSDSD
SDSDSDSDSDSDSDSD
SDSDSDSDSDSDSD
SDSD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
SD SD SD SD
SD SD SD SD
SD SD SD SD SD
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
SD SD SD SD SD SD SD SD
SD SD SD SD SD
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
SD SD SD SD
SD SD SD SD
SD SD
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
S D
FOR CONT SEE E-101
3"C POWER
3"C POWER
ELECTRICAL HANDHOLE 2' X 4'
INTERCEPT
(E) 3"C POWER STUBOUT
AND EXTEND
(E) ELEC BLDG
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720
AUGUST 14, 2020
JH/DL
ES101
1 ELECTRICAL SITE PLAN
SCALE: 1" = 20'
NORTH
PLAN
6010 20 400 1"=20'-0"
JH
JBD
SHEET NOTES:
VERIFY EXACT LOCATION OF STUB OUT IN FIELD. IF STUB-OUT NOT FOUND, PROVIDE NEW
CONDUIT BACK TO SOURCE. PROVIDE ALL REQUIRED TRENCHING AND BACKFILLING FOR NEW
DUCT AS REQUIRED FOR A COMPLETE INSTALLATION.
GENERAL NOTES:
1. REFER TO SHEET E501 FOR DUCT SECTION DETAILS.
AutoCAD SHX Text 02°02' 276.33
AutoCAD SHX Text 336°09'53" 263.52
AutoCAD SHX Text 25°25'37" 150.55
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
ELECTRICAL SITE PLAN
E
G, WP
1 2 3 4 5 6
C
B
A
EQUIPMENT BANK #1
OPEN AREA
EQUIPMENT BANK #2
WALK-IN REFER
G, WP G, WP G, WP
2SB1-7,9
2SB1-22SB1-42SB1-6
2SB1-10
2SB1-8
T
2SB1
4SB1
T-2SB1 2
J
2SB1-1
#10
#10
#10
F
G, WP
#10
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720
AUGUST 14, 2020
JH/DL
E-101
1 POWER AND SIGNAL PLAN
SCALE: 1/4" = 1'-0"
NORTH
PLAN
1/4"=1'-0" 122 3 4 6 80 1
JH
JBD
SHEET NOTES:
SERVICE OUTLET FOR WALK-IN REFER COMPRESSOR. COORDINATE
MOUNTING LOCATION WITH WALK-IN REFER EQUIPMENT INSTALLER.
TRANSFORMER SHALL BE WALL MOUNTED ABOVE PANELS AT +8' AFF.
1"C, 3#4 AWG, 1#10G.
SEAL CONDUIT AT WALK-IN PENETRATION WITH SILICON SEAL TO
PREVENT CONDENSATION.
VERIFY SIZE OF REFRIGERATION EQUIPMENT WITH OWNER PRIOR TO
START OF WORK. ADJUST SIZE OF OVERCURRENT PROTECTION
EQUIPMENT, DISCONNECT SWITCH, AND WIRING AS REQUIRED TO
SUIT EQUIPMENT PROVIDED.
Plant Growth Rooms Climate-controlled modular rooms
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
POWER AND SIGNAL PLAN
LANAIEXISTING INSECT SHED
NOT IN CONTRACT
A.1
B.1
C.1
LIGHT SWITCH WITH TIMER. WATTSTOPPER #TS-400.
HOMERUN TO EXISTING 20A/1-POLE CIRCUIT BREAKER IN (E)PANEL
4SB1 VIA 3/4" CONDUIT.
LIGHTING CONTROL NOTES:
1. LANAI LIGHTING SHALL BE CONTROLLED VIA DIGITAL
COUNTDOWN TIMER WALL SWITCH. LANAI LIGHTS SHALL BE
MANUALLY TURNED ON AND WILL AUTOMATICALLY SHUT -OFF
AFTER PRESET TIME INTERVAL.
T
J
4SB1-7
AE TYP.
(E)J-BOX
TYPE LAMPS MTG DESCRIPTON
A 36W LED
4000K, LUMENS
CEILING
SURFACE
MTD.
4' LED FULL CUT-OFF LIGHT FIXTURE.
BLACK POWDER COAT FINISH. UL
LISTED WET LOCATIONS, IP66. 120/277V
STARTEK
#HYDRD-4-1000-SD-PIS-CNDI-40K-PB
-SM-U-CRI9050
AE SIMILAR TO TYPE "A" EXCEPT WITH
BATTERY BACK-UP.
36W LED
4000K, LUMENS
CEILING
SURFACE
MTD. STARTEK
#HYDRD-4-1000-SD-PIS-CNDI-40K-PB
-SM-U-CRI9050-#EMB10
A TYP.
(E)4SB1
E
IWH-1
4SB1-5
4XSS
SHEET NOTES:
3 HOMERUN TO EXISTING 70A/1-POLE CIRCUIT BREAKER IN (E)PANEL
4SB1, 1"C, 2#4 AWG, 1#8G.
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
CONSTRUCT LANAI
64 NOWELO STREET
HILO, HI 96720
AUGUST 14, 2020
E-101
1 ELECTRICAL PLAN
SCALE: 1/4" = 1'-0"
NORTH
PLAN
1/4"=1'-0" 122 3 4 6 80 1
DL
JH
JBD
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
ELECTRICAL PLAN
1 2 3 4 5 6
C
B
A
EQUIPMENT BANK #1EQUIPMENT BANK #2
WALK-IN REFER
OPEN AREA
B
B
B B
B B
A
A
A
A
A
A
A
A
A B
B
4SB1-1
4SB1-3
LIGHTING CONTROL NOTES:
1. INTERIOR LIGHTING SHALL TURN ON TO 100% OUTPUT UPON
DETECTION OF OCCUPANCY. AFTER PRE-SET TIME DELAY OF
NO OCCUPANCY, LIGHTING SHALL REDUCE TO 50% LIGHT
OUTPUT. AFTER PRE-SET TIME DELAY LIGHTING SHALL TURN
OFF.
2. EXTERIOR LIGHTING SHALL BE PHOTOCELL CONTROLLED.
WHEN MOTION IS DETECTED LIGHTING WILL BE INCREASE
OUTPUT TO 100%. WHEN NO MOTION IS DETECTED LIGHTING
OUTPUT WILL BE REDUCED TO 50%.
C TYP.
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720AUGUST 14, 2020
JH/DL
E-102
1 LIGHTING PLAN
SCALE: 1/4" = 1'-0"
NORTH
PLAN
1/4"=1'-0" 122 3 4 6 80 1
JH
JBD
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
LIGHTING PLAN
BACKFILL NOTES THIS DETAIL:
TYPE "A" BACKFILL - EARTH & GRAVEL. ROCK SIZE TO BE 1" MAX. & THE MIXTURE
TO CONTAIN NOT MORE THAN 50% BY VOLUME OF ROCK PARTICLES. 95%
COMPACTION.
1. PAVEMENT AND/OR CONCRETE RESTORATION SHALL BE EQUAL OR BETTER
THAN ORIGINAL IN QUALITY AND THICKNESS.
2. INVESTIGATE, PROBE, AND TONE TRAVERSE OF NEW DUCTLINE.
3. DUCT SEPARATION REQUIREMENTS:
ELEC TO ELEC......................................2"
ELEC TO SIGNAL/COMM......................3"
SIGNA/COMM TO SIGNAL/COMM........2"
6"
2'-0"
3"
TYPE "A" BACKFILL
CONCRETE ENCASEMENT, 3" MIN. ALL AROUND, 3000 PSI
COMMPRESSIVE STRENGTH AT 28 DAYS WITH MAXIMUM
3/4" AGGREGATE SIZE
FINISHED GRADE
PVC SCHEDULE 40,
QTY. AND SIZE AS SHOWN ON
ONE-LINE & DRAWINGS
PROVIDE DETECTABLE RED
WARNING TAPE FOR ENTIRE
LENGTH OF DUCT
3"
3" 3"3"
SAWCUT EXISTING
PAVEMENT FOR
TRENCHING
EXISTING AC
PAVEMENT
APPLY TACK
COAT
APPLY PRIME
COAT
1'-0"
BASE COURSE,
6" MIN. OR
MATCH
EXISTING
WHICHEVER IS
GREATER
NEW PAVEMENT MIX IV 2-1/2" MIN.
OR MATCH EXISTING THICKNESS,
WHICHEVER IS GREATERSYMMETRICAL
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720AUGUST 14, 2020
DL
E-501
JH
JBD
1 TYPICAL CONCRETE ENCASED DUCTBANK DETAIL
NTS
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
DETAILS
3P400AF
320AT
EXISTING SWITCHBOARD 'MSB'
3000A, 480Y/277V, 3PH, 4W
'TSB'
75 kVA, DRY TYPE XFMR, 480 -208Y/120V, 3PH, 4W, COPPER
WINDINGS, 115°C RISE. PROVIDE
WITH 2.5% TAPS, 2+, 4-
3P400AF
320AT
3P400AF
250AT
3P400AF
3P400AF
SPARE
3P800AF
600AT
3P400AF
300AT
3P400AF
3P800AF
150AT
3P1200AF
1000AT
3P1600AF
1200AT
3P1600AF
1200AT
3P1600AF
1200AT
N.C.
TO EXISTING
SWITCHBOARD 'MSBE'
TO EXISTING GENERATOR
3P3000AF
N.O.
3000A N.C.
3000A N.C.
TO EXISTING 2000KVA
TRANSFORMER
TO EXISTING 2000KVA
TRANSFORMER
EXISTING LABORATORY BUILDING
3P400AF
NEW 2' X4' ELECTRICAL HANDHOLE
'2SB1'
208Y/120V, 3PH, 4W, 225A, 10KAIC
'4SB1'
480/277V, 3PH, 4W, 400A, 35KAIC
3"C, 4#2/0 AWG, 1#4G
1 1/2"C, 3#1/0 AWG, 1#6G 2 1/2"C, 4#4/0 AWG, 1#2G
NEW INSECT SHELTER BUILDING
3"C, 4#2/0 AWG, 1#4G
3P125A
3/4"C, 1#4 G TO 5/8" DIA X 8'-0"L COPPER
CLAD STEEL GROUND ROD AND
NEAREST METALLIC COLD WATER PIPE
1#2G
(E) 3"C, W/NEW 4#2/0 AWG, 1#4G
REPLACE (E) 400AT
TRIP UNIT WITH (N)
150AT TRIP UNIT
3P150AT
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720
AUGUST 14, 2020
DL
E-601
JH
JBD
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
ONE-LINE DIAGRAM
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720
AUGUST 14, 2020
DL
E-602
JH
JBD
PANEL 2SB1 120/208V, 3 PHASE, 4 WIRE MOUNTING: SURFACE
LOCATION SHELTER BLDG 225 AMP BUS 225 AMP MAIN BKR GRND BUS: EQUIPMENT
SHORT CKT: 10,000 RMS SYM AMPS
C CIRCUIT VA AMPS POLE CKT BUS CKT POLE AMPS VA CIRCUIT C
T DESCRIPTION NO NO DESCRIPTION T
1 L-REFER 500 20 1 1 L1 2 1 20 1200 R-CONVENIENCE OUTLET 2
SPARE - 20 1 3 L2 4 1 20 1200 R-CONVENIENCE OUTLET 2
SPARE - 20 1 5 L3 6 1 20 1200 R-CONVENIENCE OUTLET 2
3 WALK-IN REFER 5000 60 2 7 L1 8 1 20 1200 R-CONVENIENCE OUTLET 2
3 -- 5000 9 L2 10 1 20 1200 R-CONVENIENCE OUTLET 2
SPARE - 20 1 11 L3 12 1 20 - SPARE
SPARE - 20 1 13 L1 14 1 20 - SPARE
SPARE - 20 1 15 L2 16 1 20 - SPARE
SPARE - 20 1 17 L3 18 1 20 - SPARE
SPARE - 20 1 19 L1 20 1 20 - SPARE
SPARE - 20 1 21 L2 22 1 20 - SPARE
SPARE - 20 1 23 L3 24 1 20 - SPARE
PFB - - - 25 L1 26 - - - PFB
PFB - - - 27 L2 28 - - - PFB
PFB - - - 29 L3 30 - - - PFB
PFB - - - 31 L1 32 - - - PFB
PFB - - - 33 L2 34 - - - PFB
PFB - - - 35 L3 36 - - - PFB
PFB - - - 37 L1 38 - - - PFB
PFB - - - 39 L2 40 - - - PFB
PFB - - - 41 L3 42 - - - PFB
CATEGORY (CT) CONNECTED NEC DEMAND NEC DEMAND COMMENTS:
LOAD (KVA) FACTOR LOAD (KVA) ALL CIRCUIT BREAKERS SHALL BE HACR RATED.
1 LIGHTING 0.5 100% 0.50
2 RECEPTACLES 6.00 50% OVER 10 KVA 6.00
3 EQUIPMENT (CONTINUOUS) 10.00 100% 10.00
4 EQUIPMENT (NON-CONTINUOUS) 0.00 100% 0.00
5 MOTORS NO MOTORS 0.00 100% 0.00
6 NO DIVERSITY 0.00 100% 0.00
7 NOT USED 0.00 100% 0.00
TOTAL KVA 16.50 - 16.50
TOTAL AMPS 46 - 46
NEC 215.2 MINIMUM FEEDER RATING: 53
PANEL 4SB1 277/480V, 3 PHASE, 4 WIRE MOUNTING: SURFACE
LOCATION SHELTER BLDG 400 AMP BUS 400AF/150AT MAIN BKR GRND BUS: EQUIPMENT
SHORT CKT: 35,000 RMS SYM AMPS
C CIRCUIT VA AMPS POLE CKT BUS CKT POLE AMPS VA CIRCUIT C
T DESCRIPTION NO NO DESCRIPTION T
1 L - INTERIOR 1700 20 1 1 L1 2 - - - PFB
1 L - EXTERIOR, EM WALL PACKS 500 20 1 3 L2 4 - - - PFB
SPARE* - 70 1 5 L3 6 - - - PFB
SPARE - 20 1 7 L1 8 - - - PFB
SPARE - 20 1 9 L2 10 - - - PFB
SPARE - 20 1 11 L3 12 - - - PFB
2 TRANSF T-2SB1 25000 125 3 13 L1 14 - - - PFB
2 -- 25000 - - 15 L2 16 - - - PFB
2 -- 25000 - - 17 L3 18 - - - PFB
PFB - - - 19 L1 20 - - - PFB
PFB - - - 21 L2 22 - - - PFB
PFB - - - 23 L3 24 - - - PFB
PFB - - - 25 L1 26 - - - PFB
PFB - - - 27 L2 28 - - - PFB
PFB - - - 29 L3 30 - - - PFB
CATEGORY (CT) CONNECTED NEC DEMAND NEC DEMAND COMMENTS:
LOAD (KVA) FACTOR LOAD (KVA) * - CIRCUIT BREAKER SHALL BE HACR RATED
1 LIGHTING 2.20 100% 2.20
2 RECEPTACLES 75.0 50% OVER 10 KVA 42.5
3 EQUIPMENT (CONTINUOUS) 0.00 100% 0.00
4 EQUIPMENT (NON-CONTINUOUS) 13.30 100% 13.30
5 MOTORS NO MOTORS 0.00 100% 0.00
6 NO DIVERSITY 0.00 100% 0.00
7 NOT USED 0.00 100% 0.00
TOTAL KVA 90.50 - 58.00
TOTAL AMPS 109 - 70
NEC 215.2 MINIMUM FEEDER RATING: 70
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
PANEL SCHEDULES
TYPE LAMPS MTG DESCRIPTON
A 109W LED
4000K, 17818
LUMENS
CEILING
STEM
MTD. +20'
AFF
2' LED HIGH BAY LIGHT. PROVIDE WITH
INTEGRAL OCCUPANCY SENSOR FOR
HI-LOW-OFF OPERATION. 120/277V
TYPE LAMPS MTG DESCRIPTON
B 40W LED
TRU-
AMBER
WALL
MTD. +12'
AFF
LED WALL PACK. TYPE III DIST. PROVIDE
WITH INTEGRAL OCCUPANCY SENSOR
FOR STEP DIMMING OPERATION. BLACK
FINISH. 277V
US ARCHITECTURAL LIGHTING
#RZR-WM2-PLED-III-40LED-525MA-TRA
-277-RAL-9005-T-MS-F211
FLEX LIGHTING SOLUTIONS
#ES40P-A1-17K-4MS-40-80-FR-LV-CRM
-FSP-3X1B
TYPE LAMPS MTG DESCRIPTON
C 2-1.875W
LED
WALL
MTD. +12'
AFF
LED EMERGENCYWALL PACK. LIGHT
GRAY FINISH 277V
EVENLITE
#NXLED-US
TYPE LAMPS MTG DESCRIPTON
X 0.5W LED WALL
MTD.
ABOVE
DOOR
LED EXIT SIGN. BRUSHED ALUMINUM
FACE, WHITE HOUSING. MAINTENANCE
FREE. 277V
EVENLITE
#CHY-1-AW-1B
HILO, HAWAII
PACIFIC BASIN AGRICULTURAL RESEARCH CENTER
BDM
INSECT HOLDING SHELTER
64 NOWELO STREET
HILO, HI 96720AUGUST 14, 2020
JH/DL
E-603
1 LIGHT FIXTURE SCHEDULE
N.T.S
JH
JBD
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
RPR
AutoCAD SHX Text
EPM
AutoCAD SHX Text
A-E FIRM
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text
THIS WORK WAS PREPARED BY ME
AutoCAD SHX Text
OR UNDER MY SUPERVISION AND
AutoCAD SHX Text
CONSTRUCTION OF THIS PROJECT
AutoCAD SHX Text
WILL BE UNDER MY OBSERVATION.
AutoCAD SHX Text
EXPIRATION DATE OF THE LICENSE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
AUGUST 14, 2020
AutoCAD SHX Text
APRIL 30, 2022
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
LICENSED PROFESSIONAL ENGINEER
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text
NO. 15212-E
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text Y
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text W
AutoCAD SHX Text O
LIGHT FIXTURE SCHEDULE
| 19133 - Submittal 003 - 100 percent design drawings |
| 19133 - Submittal 002 - Butler Building |
| 19133 - Submittal 001 - Schedule of Values |
| Submittal 001 - Mold Remediation Work Plan |
| 2020-08-14 IFC INSECT SHELTER (2) |
| 2020-08-14 IFC INSECT SHELTER (2) |
| G-001 COVER SHEET, PROJECT SITE, PROJECT INFORMATION, INDEX OF DRAWING |
| C-001 CIVIL NOTES, ABBBREVIATIONS, SYMBOLS |
| C-002 EROSION AND SEDIMENT CONTROL NOTES |
| C-101 EXISTING CONDITION AND DEMOLITION PLAN |
| C-102 EROSION AND SEDIMENT CONTROL PLAN |
| C-103 SITE LAYOUT AND GRADING PLAN |
| C-501 DETAILS |
| S-001 STRUCTURAL NOTES |
| S-002 STRUCTURAL NOTES, ABBREVIATIONS |
| S-003 STATEMENT OF SPECIAL INSPECTIONS |
| S-101 FOUNDATION PLAN |
| S-501 DETAILS |
| P-001 PLUMBING NOTES, ABBREVIATIONS, LEGEND |
| P-101 PLUMBING PLAN |
| P-501 DETAILS |
| E-001 ELECTRICAL NOTES, ABBREVIATIONS, SYMBOLS |
| E-002 ELECTRICAL SPECIFICATIONS |
| E-102 LIGHTING PLAN |
| E-501 DETAILS |
| E-603 LIGHT FIXTURE SCHEDULE |
| C-104 |
| Sheets and Views |
| C-104_Utility |
| E-101 |
| E-101A |
| E-601 |
| E-602 |
| ES101 |
File details come from the government source that posted it. Updated .