Emergency Justification Posting.pdf
PDF 252 KB Posted
- Attached to
- XPER Equipment and System Federal contract opportunity
- Solicitation number
- 36C24621P0704
About this file
This document is a sole source justification for a federal contract award. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 awarded contract 36C24621P0704 on March 12, 2021 to an unknown vendor for an estimated $638,998.80. The sole source award is for the urgent delivery and installation of a Xper physio monitoring system at the Durham VA Medical Center. The justification cites an unusual and compelling urgency due to errors in the current cardiac monitoring equipment creating risks to patient safety, including a delay in treating a patient experiencing ventricular fibrillation. The new system will provide hemodynamic monitoring for cardiac procedures.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Opportunity Special Notice
PRODUCT SERVICE CODE *
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
ARCHIVE DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
GENERAL INFORMATION
ADDITIONAL INFORMATION
* = Required Field Contract Opportunity Special Notice
XPER Equipment and System Emergency Procurement
28301
N
339112
Department of Veterans Affairs Network Contracting Office 6 201 Hay Street, Suite 304 Fayetteville NC 28301
Contract Specialist Isaac Hernandez Isaac.Hernandez@hotmail.com
(910) 488-2120 x: 5862 https://www.va.gov
VA.gov
Isaac.Hernandez@va.gov
VA.gov
See attached document: P03 JA for Xper Equipment and System.
PM Part 813.5 SAP for Certain Commercial Items Page 1 of 6 Original Date: 08/30/17 Revision 03 Date: 02/11/2021
DEPARTMENT OF VETERANS AFFAIRS
SOLE SOURCE JUSTIFICATION UNDER SIMPLIFIED PROCEDURES FOR CERTAIN COMMERCIAL
ITEMS IN ACCORDANCE WITH FAR 13.5
Acquisition Plan Action ID: 36C246-21-AP-2252
1. Contracting Activity: Department of Veterans Affairs, Network Contracting Office (NCO) 6, on behalf of Durham VA Medical Center; PR # 558-21-2-102-0015.
2. Nature and/or Description of the Action Being Processed: This is an emergency, open market, Firm-Fixed-Price procurement for the Xper physio monitoring system in accordance with FAR 13.5 Simplified Procedures for Certain Commercial Items and specifically FAR 13.501 Special Documentation Requirements, where acquisitions conducted under Simplified Acquisition Procedures are exempt from the requirements of FAR Part 6, but still require a justification using the format of FAR 6.303-2. This will be a new contract, sole source award to the manufacturer a large business for the delivery and install of the Xper equipment and system. Estimated value of this requirement is $638,998.80.
3. Description of Supplies/Services Required to Meet the Agency’s Needs: For the delivery and install of a Xper physio monitoring system. This system is a hemodynamic monitoring system for cardiac monitoring where interventional procedures are performed in the Cardiac Cath, electrophysiology and interventional radiology labs. The system displays and analyzes surgace ECG, respirations, invasive pressures, pulse oximetry end tidal CO2, FFR, non-invasive blood pressure, surface body temperature and thermal cardiac output. The system also provides for clinical data acquisition, medical image and data processing and analytical assessments. Typical delivery and install of this complex system takes sixty or more days.
Product Description Part Number Quantity
NITD903 Xper IM Data Center SW w/1 CU NITD903 1
FIT3750 Xper IM Client SW Site License FIT3750 1
NITD904 Xper IM Doc Wkflow Modules NITD904 1
NITD910 Xper IM Charting NITD910 1
NITD911 Xper IM Hemo Calculations NITD911 1
NITD912 Xper IM Vitals Capture NITD912 1
Hemo App Generic Workflow FIT4187 4
Abbott FFR Analogue Hemo App FIT4190 2
ET CO2 Side Stream Hemo App FIT4193 4
PM Part 813.5 SAP for Certain Commercial Items Page 2 of 6
Revision 03 Date: 02/11/2021
Philips Hemo Control Room FIT4143 4
Philips Hemo Nurse Station FIT4146 4
FIT4007 Side Stream ET CO2 Cables FIT4007 4
FIT3961 Xper Flex Cardio 2010 FIT3961 1
Accessory Kit A Philips Hemo FIT4152 4
FIT3980 Xper Flex Cardio Table Mount FIT3980 4
FIT3981 XDS Wall Mount FIT3981 4
NITD591 New CV Solutions Core License NITD591-2 1
NITD947 New Cath Theme License NITD947 1
FIT3241 HL7 ADT Interface FIT3241-1 1
FIT3244 HL7 Orders Interface FIT3244-1 1
FIT3802 Xper IM End of Case Report FIT3802 1
FIT3808 Xper IM Study Notification FIT3808 1
FIT3809 Xper IM Labs Interface FIT3809 1
FIT3810 Xper IM IntelliVue Interface FIT3810 1
FIT3813 Xper IM Outbound Inventory FIT3813 1
FIT4022 Xper IM Inbound Inventory IF FIT4022 1
FIT4024 Xper IM GE CardioLab EP IF FIT4024 1
FIT3174 DMWL 1-10 FIT3174-1 4
XPER Install Cable Kit-Ctrl Rm for CI 989803203431 4
Orders IF Impl Services 89801200789-1 1
ADT Interface Impl Services 989801200796-1
Xper Weekend Upgrade Services
989801200737
Xper ICL Training
989801200907
PM Part 813.5 SAP for Certain Commercial Items Page 3 of 6
Xper IM Clinical Super User ILT Course
989801200730
Remote XPER Training/Consulting (8 Hrs)
989801200903-1
Onsite XPER Training/Consulting (8 Hrs)
989801200902
Xper IM Flex Cardio Biomed Course
989801200721-1
Xper IM Outbound Inventory Imp
989801200943
Xper IM Inbound Inventory Imp
989801200988
Xper IM Outbound/Inbound IF (NEW PS Hrs)
989801200922-1
Xper IM GE CardioLab EP IF New PS Hours
989801200931-1
GE CardioLab EP I/F Implementation
989801200954
Xper IM PIIC iX/IntelliVue IF PS Hours
989801200937-1
PIIC iX/IntelliVue IF Implementation
989801200950
Xper IM Labs Implementation
989801200985
Xper IM Labs I/F (PS Project hours)
989801200921
Xper IM Study Notification Imp
989801200948
Xper IM End of Case Report Imp
989801200946
Xper App Support (New/S4) 4-6 Rms
989801200899-
VA
Xper IM Doc Wkflow Modules Imp
989801200959
Xper IM Charting Implementation
989801200965
Xper IM Hemo Calculations Imp
989801200966
PM Part 813.5 SAP for Certain Commercial Items Page 4 of 6
Xper IM Vitals Capture Implementation
989801200967
Xper FC Nurse/Bedside/Central Install
989801200976
Additional Room Install/Imp
989801200977
Xper IM Data Center SW Imp
989801200958
Cable Install Service
989801202008
Hemo Implementation and Training Srvs
989801202046
CV Solutions Core Implementation Services
989801200779-1
4. Statutory Authority Permitting Restricted Competition:
FAR 13.5 Simplified Procedures for Certain Commercial Items. The statutory authority for applying the Simplified Procedures for Commercial Items of FAR 13.5 is 41 U.S.C. § 1901 and is implemented by FAR 13.106-1(b)(2) for restricting competition on this procurement. Competition is restricted on this procurement for the reason below:
( ) Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements
( X ) Unusual and Compelling Urgency ( ) Industrial Mobilization, Engineering, Developmental or Research Capability or Expert
Services ( ) International Agreement ( ) Authorized or Required by Statute ( ) National Security ( ) Public Interest
5. Demonstration that the Contractor’s Unique Qualifications or Nature of the Acquisition Requires the Use of the Authority Cited Above (applicability of authority): This is an urgent and compelling need for cardiology due to patient safety. The current equipment and system in use is creating errors in the representation of information from the EKG leads. As a result of this artifact in EKG leads, a patient ended up being in V-fib (not sustainable heart rhythm) and there was a delay in treating this patient because the EKG tracings on the current system were not readable and clear.
Patient had to be resuscitated through external defib. Continuation to rely on the current system will put our Veteran patients at risk and is dangerous. Bio-med is constantly trying to piece together patches/fixes for this system to work. It is in the services best interest of Durham VAMC to replace this system immidiately. Any delays in the procurement of this system could have catastrophic consequences to our Veterans needing emergency life saving services.
6. Description of Efforts Made to ensure that offers are solicited from as many potential sources as deemed practicable: This requirement is for a direct upgrade and replacement of current equipment and system that is in use by Durham VA Medical Center. The manufacturer has authorized distributors for this system, but this would cause delay’s in the procurement due to
PM Part 813.5 SAP for Certain Commercial Items Page 5 of 6
Revision 03 Date: 02/11/2021 seeking an individual waiver from the Small Business Administration. These delays would unnecessarily put our Veteran population at risk.
7. Determination by the CO that the Anticipated Cost to the Government will be Fair and Reasonable: The Contracting Officer anticipates cost will be considered fair and reasonable. The Contracting Officer will request invoices of what other Government or Civilian hospitals have paid for this equipment and system in the past.
8. Description of the Market Research Conducted and the Results, or a Statement of the Reasons Market Research Was Not Conducted: VA Vendor Information Pages (VIP) was searched and a review of the query yielded no company’s able to provide the requested Xper equipment and system. A telephonic conversation with the manufacturer Philips Healthcare suggested using Four Points Technology a Service Disabled Veteran Owned Small Business as their authorized distributor.
It was explained that contracting would need to seek approval from Small Business Administration for a waiver to the non-manufacturer rule and that this requirement is so urgent and compelling that this would cause undue harm to the service. The Contract Specialist searched various Federal Supply Schedules for the Xper equipment and system and did not find any existing contracts for this equipment and system. A sources sought notice was not published on Beta.SAM.gov due to the urgent and compelling need of this requirement.
9. Any Other Facts Supporting the Use of Other than Full and Open Competition: None.
10. Listing of Sources that Expressed, in Writing, an Interest in the Acquisition: Four Points Technology an SDVOSB vendor but due to urgency, and mandatory compliance with the NMR rule. The Government will not seek to utilize Small Business.
11. A Statement of the Actions, if any, the Agency May Take to Remove or Overcome any Barriers to Competition before Making subsequent acquisitions for the supplies or services required: The agency will continue to conduct market research to overcome barriers to competition in the future.
12. Requirements Certification: I certify that the requirement outlined in this justification is a Bona Fide Need of the Department of Veterans Affairs and that the supporting data under my cognizance, which are included in the justification, are accurate and complete to the best of my knowledge and belief.
Nakisha Atkins Date Nurse Manager Durham VAMC
13. Approvals in accordance with the VHAPM Part 806.3 OFOC SOP:
a. Contracting Officer or Designee’s Certification (required): I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
Date
NAKISHA N.
ATKINS 379125
Digitally signed by
NAKISHA N. ATKINS 379125
Date: 2021.03.10 07:41:56 -05'00'
Cherisse A. Hall 613334
Digitally signed by Cherisse A.
Hall 613334 Date: 2021.03.10 11:03:57 -05'00'
PM Part 813.5 SAP for Certain Commercial Items Page 6 of 6
Revision 03 Date: 02/11/2021
b. One Level Above the Contracting Officer (Required over SAT but not exceeding $750K): I certify the justification meets requirements for other than full and open competition.
Date
NCO/PCO 06
KEESHIA R
NEWMAN
254911
Digitally signed by
KEESHIA R NEWMAN
254911 Date: 2021.03.10 11:40:17 -05'00'
| Emergency Justification Posting.pdf |
| P03 JA for Xper Equipment and System Signed.pdf |
File details come from the government source that posted it. Updated .