EDR_CUI.pdf
PDF 1 MB Posted
- Attached to
- TPS-75 Dehydrator Compressor Federal contract opportunity
- Solicitation number
- SPRHA522R0859
- Issued by
- Defense Logistics Agency Aviation
About this file
This document contains an engineering data requirements attachment and technical specifications for a TPS-75 Dehydrator Compressor solicitation. The solicitation is set aside 100% for small businesses and provides a technical data package under the links on the attachments page. The engineering data requirements attachment specifies manufacturing instructions for a compressor/dehydrator assembly with part number 80973801-01 and national stock number 4440-01-582-1594ZR. It outlines required specifications, standards, testing procedures, and unique identification marking in accordance with MIL-STD-130. Tests include verifying rated performance by measuring delivery flow, outlet air temperature and dew point, and compressor restart and shutoff times under specified conditions. The Defense Logistics Agency Aviation is the contracting agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CPP_CUI.pdf | ||
| EDL_CUI.pdf | ||
| Pkg_SOW_CUI.pdf | ||
| MQR_CUI.pdf | ||
| SPRHA522R0859.pdf | ||
| TR_CUI.pdf | ||
| SPI_CUI.pdf | ||
| TP_CUI.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REV: ENGINEERING DATA REQUIREMENTS
(ATTACHMENT “A”)
NOTE: MILITARY SPECIFICATIONS / STANDARDS WILL NOT BE FURNISHED IN THE BID SET.
1. THE FOLLOWING INSTRUCTIONS ARE FURNISHED FOR THE MANUFACTURE OF:
COMPRESSOR/DEHYDRATOR, COMPRESSOR ASSEMBLY (AN/TPS-75)
2. PART NUMBER:
80973801-01
3. NATIONAL STOCK NUMBER:
4440-01-582-1594ZR
PREPARED BY:
JOHN LOVE
OFFICE SYMBOL:
AFMC/GUMAB
DATE:
20181108
HILL AFB FORM 462 Page 1 of 2
4. THE FOLLOWING SPECIFICATIONS/STANDARDS, ETC., WILL BE USED IN LIEU OF THE DATA INDICATED. THE SUPERSEDED DATA
WILL NOT BE FURNISHED UNLESS SO INDICATED.
5. THE SOURCES/MATERIALS IF LISTED ON THE STANDARDS, SPECIFICATION AND DRAWINGS ARE THE ONLY SOURCES/MATERIALS FOR THOSE ITEMS. SUBSTITUTIONS SHALL HAVE PRIOR APPROVAL BY THE COGNIZANT ENGINEERING
ACTIVITY.
6. DEVIATIONS FROM SPECIFICATIONS IDENTIFIED IN CONTROL DRAWINGS ARE NOT AUTHORIZED WITHOUT PRIOR APPROVAL
BY THE COGNIZANT ENGINEERING ACTIVITY.
7. UNIQUE IDENTIFICATION (UID) SHALL BE APPLIED PER MIL-STD-130:
A. MINIMUM 1/8TH INCH ON HUMAN READABLE TO INCLUDE:
1. CAGE (17V)
2. P/N (1P)
3. SERIAL NUMBER (1S)
B. MINIMUM 1/4 INCH SQUARE ON MACHINE READABLE 2D MATRIX – CONSTRUCT 2 – TO
INCLUDE:
1. CAGE (17V)
2. P/N (1P)
3. SERIAL NUMBER (1S)
C. LABEL SHALL CONTAIN ALL DATA ON EXISTING LABEL, IF EXISTING LABEL IS TO BE
REPLACED.
D. SAME LABEL MATERIAL SHALL BE USED AS SPECIFIED IN DRAWING FOR EXISTING
LABEL.
E. MIL-STD-130, ANSI/AIM BCII, ISO 15434, ISO 15415, AND ISO 15418.
8. TESTING
These tests required as First Article and unit Acceptance Test.
Test Equipment Required
Item Range Air Dew Point Meter 0-100 percent Air-Flow Meter 0.31-3.17 SCFM Pressure Gage 0-100 PSIG Needle Valve (Swagelok(3T9T9) PN: B-4VF4) Or equivalent Reservoir Volume: 2 gallons minimum;
Pressure rating: appropriate to test pressure w/ safety margin.
1. The compressor-dehydrator must be performance tested to ensure rated performance is attained.
a. Test environment: All test should be performed in an ambient environment of 77 ±18°F at a maximum of 90% relative humidity, and a barometric pressure of 28 to 30 inches of mercury.
b. Required Power Input. An electrical power input of 208 volts, 400 Hz, 3 phase, 4 amps is required.
i. Connect ground wire to compressor dehydrator chassis.
CUI
CUI
Controlled by: DLA Aviation Ogden
Controlled By: AUBA CUI Category: Controlled Tech info
Distribution/ Dissemination Control: FEDCON POC: michelle.mihu@us.af.mil
REV: ENGINEERING DATA REQUIREMENTS
(ATTACHMENT “A”)
NOTE: MILITARY SPECIFICATIONS / STANDARDS WILL NOT BE FURNISHED IN THE BID SET.
1. THE FOLLOWING INSTRUCTIONS ARE FURNISHED FOR THE MANUFACTURE OF:
COMPRESSOR/DEHYDRATOR, COMPRESSOR ASSEMBLY (AN/TPS-75)
2. PART NUMBER:
80973801-01
3. NATIONAL STOCK NUMBER:
4440-01-582-1594ZR
PREPARED BY:
JOHN LOVE
OFFICE SYMBOL:
AFMC/GUMAB
DATE:
20181108
HILL AFB FORM 462 Page 2 of 2
2. Test Setup
a. The reservoir w/pressure gauge is connected to the compressor dehydrator outlet, the needle valve to the reservoir, the flow meter to the needle valve, the dew point meter to the flow meter.
3. Operational Test
a. Delivery Flow Test.
i. Set needle valve open. With compressor dehydrator running, set outlet pressure to 25 psig.
Output air flow must not be less than 0.5 SCFM at 25 (±1) psig.
ii. With needle valve open, operate systems for 10 to 15 minutes and verify the desiccant in the sight glass on the desiccant container assembly is a blue color
b. Outlet Air Temperature and Dew Point
i. Operate system for 30 minutes. Outlet air temperature must not be higher than 40°F above inlet ambient temperature. Outlet air dew point must be 10°F maximum at an inlet ambient temperature of 70°F to 130°F; or 60°F below inlet temperature at ambient of -20°F to +70°F
c. Compressor Restart and Shut Off Times
i. Refer to Figure 8-1. Close needle valve. Pressurize reservoir to 27 psig and ensure compressor dehydrator turns off. Note time. Compressor should be off for a minimum of 3 hours and should not drop more than 3 psi. (Duty cycle of 90:1).
CUI
CUI