Report_Bridge_Inspection_2015.pdf
PDF 3 MB Posted
- Attached to
- George Washington Memorial Parkway Federal contract opportunity
- Solicitation number
- DTFH71-17-B-00030
About this file
Report_Bridge Inspection_2015
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_0005_-_NP-GWMP_210(1).pdf | ||
| Amendment_0004_-_NP-GWMP_210(1).pdf | ||
| Amendment_0003_-_NP-GWMP_210(1).pdf | ||
| Amendment_0002_-_NP-GWMP_210(1).pdf | ||
| Amendment_0001_-_NP-GWMP_210(1).pdf | ||
| Plans_-_NP-GWMP_210(1).pdf | ||
| Report_NEPA.pdf | ||
| FP14_Eng.pdf | ||
| Report_Certification_Program_for_Bridge_Temporary_Works.pdf | ||
| VETS-4212_Form.pdf | ||
| Report_GWMP_Transportation_Management_Plan.pdf | ||
| IFB_Solicitation_-_NP-GWMP_210(1).pdf | ||
| Synopsis_-_NP-GWMP_210(1).doc | DOC document |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRIDGE INSPECTION REPORT
CIA OVERPASS
CIA ENTRANCE RAMP OVER GWMP
GEORGE WASHINGTON MEMORIAL PARKWAY
LW
STRUCTURE NO. 3300-003P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 4/24/15
Report prepared by: SS
MILE POINT: 2.20
Federal Highway Administration KILOMETER POINT: 3.54 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 3300-003P
CIA OVERPASS INSPECTION DATE: 4/24/15
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... PRESTRESSED CONCRETE NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 10 STRUCT. TOTAL LENGTH: .. 167.3 FT (51.0 M)
DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH: .......... 112.0 FT (34.1 M) WEARING SURFACE: .......... MONOLITHIC CONCRETE DECK WIDTH: ...................... 62.3 FT (19.0 M) ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 54.0 FT (16.5 M)
PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. 1984
PROJ./PLAN REF. NO: ......... 1A12 / 117.1- SKEW ANGLE: ..................... 22 °
NPS ROAD CLASS: .............. 7 - URBAN PARKWAY FRACTURE CRITICAL: ........ NO
STRUCTURE HISTORY: ...... 1984-MAJOR RECONSTRUCTION/SUPERSTRUCTURE. 2008-EXPANSION JOINT OVER EAST
PIER REPLACED, APPROACHES REPAVED. 2014-EXPANSION JOINT OVER EAST PIER
LOCATION
GEORGE WASHINGTON MEMORIAL PARKWAY MILE POINT: ..................... 2.20 (KM PT 3.54) STATE: ................................. VIRGINIA LOCATION: 2.2 MILES SOUTH OF I-495. IN
GENERAL VICINITY OF CIA BUILDING. PHONEFACILITY CARRIED: ............ CIA ENTRANCE RAMP
PARK POLICE (202-610-7500) AND CIA DISPATCH
FEATURE INTERSECTED: .. GW MP OFFICE (703-482-4368) ON DAY OF INSPECTION.
STRUCTURE EVALUATION SUMMARY
This three-span multi-girder prestressed concrete bridge is currently in fair to poor condition overall. The main problem is delamination and spalling with exposed rebar throughout the girders, diaphragms, pier caps, and east abutment breastwall. Steel prestressing strands are also exposed on several girders. A particular area of concern is the deterioration at the end of Girders #2 through #4 in the center span near the east pier, as the adjacent east span girders bear on the center span girders at this location. In addition, all of the bridge bearings are corroding.
Other problems include deteriorated silicone sealant in the sidewalks, inadequate anchor bolt lengths for the railing posts, and missing mortar at the top of southeast wingwall.
Since the previous inspection, the expansion joint over the east pier has been replaced.
Corrective action should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: D.E. KENT, R. PARKER (GANNETT FLEMING)
CONDITION ASSESSMENT:
DANIEL E. KENT, P.E., FIELD TEAM LEADER
REPORT REVIEW :
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 8/13/15
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3300-003P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
B226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
58.2 REPLACE SILICONE SEALANT IN SIDEWALK EXPANSION JOINTS. 100 LF
59.1 RESET GIRDER #2 BEARING DEVICE AT EAST PIER, EAST SPAN. 1 LS
58.6 REPLACE RAILING ANCHOR BOLTS AS NECESSARY TO MEET MINIMUM LENGTH
REQUIREMENTS.
1 LS
60.6 REPLACE MISSING MORTAR AT TOP OF SOUTHEAST WINGWALL. 20 LF
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS) QTY. UNIT UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
59.2,6, 60.1,3,13,1
REMOVE DETERIORATED CONCRETE FROM SUPERSTRUCTURE
AND SUBSTRUCTURE ELEMENTS. CLEAN EXPOSED REBAR AND
PRESTRESSING STRANDS. PLACE CONCRETE TO ORIGINAL LINES.
1 LS
58.1 CLEAN AND SEAL CONCRETE DECK SURFACE. 1 LS
59.1 CLEAN AND PAINT BEARINGS. 1 LS
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 3300-003P
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
N
58. DECK ITEM REFERENCE AND REMARKS
OTHER
ALIGNMENT
DEFLECTION AND/OR VIBRATION
FASCIA(E)
DIAPHRAGMS AND BRACING
TRUSSES
FLOOR BEAMS AND STRINGERS
ARCH(ES) OR SLAB(S)
GIRDERS OR BEAMS
BEARING DEVICES
59. SUPERSTRUCTURE
OTHER
DEFLECTION AND/OR VIBRATION
UTILITIES
DRAINS AND DRAINAGE
PARAPETS AND/OR RAILINGS
CURBS, SIDEWALKS, AND MEDIAN
RIDEABILITY
WEARING SURFACE
EXPANSION JOINTS
DECK SLAB
OTHER
SETTLEMENT OR DEFLECTION
EROSION AND/OR SCOUR
FOUNDATIONS
CAPS AND/OR BEARING SEATS
PILE BENTS
WALLS AND/OR COLUMNS
PIER(S)
OTHER
SLOPE PROTECTION
SETTLEMENT OR DEFLECTION
EROSION AND/OR SCOUR
EXPANSION JOINTS
WEEP HOLES
WINGWALLS
FOUNDATIONS
BACKWALLS AND/OR BULKHEADS
CAPS AND/OR BEARING SEATS
PILE BENTS
BREASTWALLS OR COLUMNS
ABUTMENTS
60. SUBSTRUCTURE
1.
10.
2.
3.
4.
5.
6.
7.
8.
9.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PAINT
11.
P P N N N F N N G
N G
F N F G N F F N G G G N
F N F N G G N
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
12.
13.
14.
15.
16.
17.
18.
19.
(BURIED)
(BURIED)
58.1 MINOR TRANSVERSE CRACKING OF DECK SURFACE. SAW CUT
FOR SENSOR IN DECK SURFACE FROM MIDSPAN TO WEST END OF
DECK IN WESTBOUND LANE ALONG NORTH CURBLINE HAS BEEN
SEALED IN PAST.
WIDESPREAD MINOR TO MODERATE TRANSVERSE CRACKING OF
DECK UNDERSIDE WITH EFFLORESCENCE. MINOR TRANSVERSE
CRACKING OF UNDERSIDE OF OVERHANGS, SOME WITH
EFFLORESCENCE.
58.2 MINOR ACCUMULATION OF DEBRIS IN STRIP SEAL EXPANSION
JOINT OVER EAST PIER. NEW EXPANSION JOINT INSTALLED SINCE
PREVIOUS INSPECTION OVER EAST PIER.
SILICONE SEALANT IN SIDEWALK EXPANSION JOINTS
DETERIORATED THROUGHOUT.
58.5 MINOR TRANSVERSE CRACKING OF CURBS, SIDEWALKS, AND
MEDIAN WITH EFFLORESCENCE. MINOR TO MODERATE
DELAMINATION AND SPALLING WITH EXPOSED REBAR ON BOTH
SIDEWALKS IN EAST SPAN. MODERATE TO SEVERE
DETERIORATION OF MORTAR BETWEEN SIDEWALK AND GRANITE
CAP FOR NORTHEAST WINGWALL. MINOR OPEN GAP BETWEEN
SIDEWALK AND GRANITE CAP FOR SOUTHWEST WINGWALL.
58.6 SEVERAL RAIL POST ANCHOR BOLTS TOO SHORT TO FULLY
ENGAGE NUT, PRIMARILY NEAR EAST END OF SOUTH RAILING.
END CAP MISSING FROM WEST END OF CENTER RAIL, SOUTH
RAILING.
58.7 DECK DRAINAGE PIPES INSIDE PIERS DISCONNECTED FROM DECK
DRAINS AND NO LONGER IN USE.
58.8 UTILITY ACCESS COVERS RUSTED THROUGHOUT SIDEWALKS.
59.1 MODERATE CORROSION OF ALL BEARINGS; SEVERE CORROSION
WITH SECTION LOSS ON MOST PIER BEARINGS. BEARING SOLE
PLATE FOR GIRDER #2 AT EAST PIER, EAST SPAN, MISALIGNED UP
TO 1".
N G G F G G
N
G
G
F
ITEM REFERENCE AND REMARKS
STREAM BED COMPOSITION : 9.
AVERAGE CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION3.
EROSION AND/OR SCOUR2.
ALIGNMENT1.
61. CHANNEL N
222. APPROACHES 6
OTHER 9.
ALIGNMENT 8.
SIGNS7.
SETTLEMENT 6.
EROSION5.
SURFACING4.
APPROACH GUARDRAIL 3.
2. RELIEF JOINTS
APPROACH SLABS1.
(VEGETATION)
N N N G G F G G P
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION5.
EROSION AND/OR SCOUR4.
FOUNDATION3.
WEEP HOLES2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDSD.
APPROACH GUARDRAILSC.
TRANSITIONSB.
BRIDGE RAILINGSA. 1
N N N
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required.
59.2 MINOR EFFLORESCENCE THROUGHOUT PRESTRESSED GIRDERS.
MINOR VERTICAL CRACKING OF EXTERIOR GIRDERS AT END
SPANS; MODERATE EFFLORESCENCE ON GIRDER #1 IN EAST SPAN.
MODERATE CRACKING, DELAMINATION, AND SPALLING WITH
EXPOSED REBAR ON CENTER SPAN GIRDER ENDS OVER BOTH
PIERS; MODERATE TO SEVERE DELAMINATION AND SPALLING WITH
EXPOSED REBAR ON ENDS OF CENTER SPAN GIRDERS #2 - #4
OVER EAST PIER. (NOTE THAT CENTER SPAN GIRDER ENDS SERVE
AS BEARING SEATS FOR EAST AND WEST SPAN GIRDERS.) MINOR
TO MODERATE DELAMINATION AND SPALLING WITH EXPOSED
REBAR AND PRESTRESSING STRANDS ON BOTTOM FLANGE OF
EAST AND WEST SPAN GIRDER ENDS, GIRDERS #2 - #9, AT PIERS.
MINOR SPALL WITH EXPOSED REBAR, BOTTOM FLANGE OF GIRDER
#6, EAST SPAN NEAR EAST ABUTMENT.
MINOR SPALL WITH EXPOSED REBAR STIRRUP, BOTTOM FLANGE
OF GIRDER #1, CENTER SPAN NEAR WEST PIER. MINOR SPALL
WITH EXPOSED REBAR AND TWO MINOR AREAS OF DELAMINATION,
BOTTOM FLANGE OF GIRDER #2, CENTER SPAN OVER
NORTHBOUND LANES. SEVERAL MINOR AREAS OF DELAMINATION,
WEB AND BOTTOM FLANGE OF GIRDER #2, CENTER SPAN OVER
MEDIAN AND SOUTHBOUND LANES (TWO DELAMINATED AREAS AT
NORTH FACE OF GIRDER #2 OVER SOUTHBOUND LANES COULD
FALL ON TRAFFIC). MINOR SPALLING WITH EXPOSED REBAR, TOP
FLANGE OF GIRDER #2, CENTER SPAN OVER SOUTHBOUND LANES.
MINOR SPALL WITH EXPOSED PRESTRESSING STRAND, BOTTOM
FLANGE OF GIRDER #3, CENTER SPAN NEAR EAST PIER.
MODERATE SPALL WITH EXPOSED REBAR AND PRESTRESSING
STRANDS, BOTTOM FLANGE OF GIRDER #3, CENTER SPAN OVER
NORTHBOUND LANE (VISUAL INSPECTION OF GIRDERS OVER
TRAVEL LANES DURING THIS INSPECTION).
MINOR DELAMINATION AND SPALLING, BOTTOM FLANGE OF ALL
BEAMS, WEST SPAN AT WEST ABUTMENT. MINOR AREA OF
DELAMINATION, BOTTOM FLANGE OF GIRDER #3, MID-LENGTH OF
WEST SPAN.
59.6 MINOR HORIZONTAL CRACKING OF SEVERAL DIAPHRAGMS.
MODERATE CRACKING, DELAMINATION, AND SPALLING WITH
EXPOSED REBAR ON END DIAPHRAGMS AT BOTH ENDS OF CENTER
SPAN OVER PIERS. MINOR TO MODERATE SPALLING WITH
EXPOSED REBAR ON SEVERAL OTHER END DIAPHRAGMS, END
SPANS OVER PIERS.
60.1,3 MINOR VERTICAL CRACKING OF ABUTMENT BREASTWALLS AND
BEARING SEATS. MODERATE CRACKING, DELAMINATION, AND
SPALLING WITH EXPOSED REBAR ON BEARING SEAT AREA AT
SOUTH END OF EAST ABUTMENT BREASTWALL.
60.6 MINOR DETERIORATION OF AND EFFLORESCENCE FROM MORTAR
JOINTS ON ALL WINGWALLS. MINOR MISSING MORTAR BETWEEN
GRANITE CAP AND TOP OF SOUTHEAST WINGWALL. MINOR
CRACKING OF GRANITE CAP AT RAIL POST ATTACHMENTS OVER
BOTH WINGWALLS AT EAST ABUTMENT.
ADDITIONAL ITEM REFERENCE AND REMARKS
60.7 MINOR RUSTING OF WEEP HOLE PIPES.
60.11 SMALL SIZE RIPRAP ON ABUTMENT SLOPES.
60.13 MINOR DELAMINATION AT TOP OF CENTER COLUMN, EAST FACE OF WEST PIER. MINOR VEHICLE SCRAPES ON
SOUTH AND CENTER COLUMNS, WEST FACE OF EAST PIER.
60.15 MODERATE TO SEVERE CRACKING, DELAMINATION, AND SPALLING WITH EXPOSED AND RUSTED REBAR THROUGHOUT BOTH PIER CAPS, PRIMARILY EAST CAP; PREVIOUS REPAIRS EXHIBIT MODERATE TO SEVERE
DETERIORATION.
222.6 MODERATE SETTLEMENT OF SOUTH SIDEWALK AT WEST APPROACH. MODERATE SETTLEMENT OF CURBS AT
BOTH APPROACHES.
222.7 REFLECTIVE OBJECT MARKERS AT UNDERPASS APPROACHES ON SOUTH END OF EAST PIER AND NORTH END
OF WEST PIER.
222.9 PREVIOUS MODERATE TO HEAVY VEGETATION AND TREES OVERHANGING EASTBOUND LANE AT WEST
APPROACH HAVE BEEN REMOVED.
STRUCTURE LOAD RATING STRUCTURE NO. 3300-003P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 15 14 25 23
HS 23 21 39 35
TYPE 3 23 21 38 34
TYPE 3S2 26 24 44 40
TYPE 3-3 29 26 48 43
DESIGN LOADING: H20 (M18)
CAPACITY MEETS OR EXCEEDS DESIGN LOAD
X CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: RATING HAS BEEN REDUCED DUE TO DETERIORATION OF SUPERSTRUCTURE. STRUCTURE DOES NOT
REQUIRE POSTING AT THIS TIME, HOW EVER.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3300-003P
STRUCTURE IDENTIFICATION
(201) PARK: GEORGE WASHINGTON MEMORIAL PARKWAY
(202) STRUCTURE NAME: .......... CIA OVERPASS
(203) STRUCTURE KIND: ............ 1 - BRIDGE
(204) STRUCTURE NUMBER: ..... 3300-003P
(205) NPS REGION: .................... 2 - NATIONAL CAPITAL
(206) ROUTE CODE NUMBER: ... 210
(207) ROAD SECTION NO: .......... 003P
(208) NPS ROAD CLASS: ............ 7 - URBAN PARKWAY
(209) WITHIN NPS BNDRY?: ....... YES
(210) OPERATING UNIT: ............. PARK
(211) PROJECT NO(S): ................ 1A12
(212) DRAWING NUMBERS: ....... 117.1-
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE
(22) OWNER: ............................... 01 - STATE HIGHWAY AGENCY
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY/PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR: ..
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORICAL DESIGNATION: ..
513 - VIRGINIA (VA)
059 - FAIRFAX
162000010
GWMP
CIA ENTRANCE RAMP
3300003P0000000
2.2 MILES SOUTH OF I-495.
99.99 FT (99.99 M)
2.20 (KM PT 3.54)
3 - FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
5 - PRESTRESSED CONCRETE
02 - STRINGER/MULTI-BEAM or GIRDER
112.0 FT (34.1 M)
167.3 FT (51.0 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
1 - CONCRETE CAST-IN-PLACE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 1 - MONOLITHIC CONCRETE
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... YES
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 4 - H20 (M18) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 23.4 TONS (21.2 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 39.1 TONS (35.5 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 4/15 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3300-003P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 38°57'30.10"
(17) LONGITUDE: ......................... 77°08'36.60"
(19) DETOUR LENGTH: ............... 0 MI (0 KM)
(28A) LANES ON STRUCT:
(28B) LANES UNDER STRUCT: ... 05
(42A) SERVICE ON: ..................... 5 - HIGHWAY-PEDESTRIAN
(42B) SERVICE UNDER: .............. 1 - HIGHWAY
(29) AVG. DAILY TRAFFIC:
(30) YEAR OF ADT:
(114) FUTURE ADT:
(115) YEAR OF FUTURE ADT:
(101) PARALLEL STRUCTURE: ... N - NONE
(38) NAVIGATION CONTROL?: ... N
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)
(111) ABUT. OR PIER PROT:
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 8.3 FT (2.5 M)
(56) LEFT: ......................... 8.1 FT (2.5 M)
(51) CURB TO CURB WIDTH: ........... 54.0 FT (16.5 M)
(52) DECK WIDTH: ............................ 62.3 FT (19.0 M)
(32) APPR. ROADWAY WIDTH: ........ 54.0 FT (16.5 M)
(213) APPR. PAVEMENT WIDTH: ..... 54.0 FT (16.5 M)
LEFT SHOULDER: .................. 0.0 FT (0.0 M)
RIGHT SHOULDER: ................ 0.0 FT (0.0 M)
(33) BRIDGE MEDIAN: ....................... 2 - CLOSED MEDIAN (no barrie
(34) SKEW ANGLE: ............................ 22 °
(35) DECK FLARE?: ........................... NO
(47) TOTAL HORIZ. CLEARANCE: .... 24.0 FT (7.3 M)
(50) SIDEWALKS:
LEFT : ...................................... 2.9 FT (0.9 M)
RIGHT : ................................... 2.9 FT (0.9 M)
(214) BRIDGE RAIL TYPE:
RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE
MATERIAL: .............................. 4 - STEEL
DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL
(215) BRIDGE RAIL HEIGHT: ............ 3.67 FT (1.12 M)
(53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 15.17 FT (4.62 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL: .......................... N
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 1NNN
(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB
(75B) WORK DONE BY: ............. 1 - CONTRACT
(76) IMPROVEMENT LENGTH: .. 167.0 FT (50.9 M)
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
N - Not over waterway.
2 - REHAB/RECONSTRUCTION
B - MAJOR
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
1984-MAJOR RECONSTRUCTION/SUPERSTRUCTURE. 2008-EXPANSION JOINT OVER EAST PIER REPLACED, APPROACHES
REPAVED. 2014-EXPANSION JOINT OVER EAST PIER REPLACED.
(231) ADDITIONAL CONSIDERATIONS:
PHONE PARK POLICE (202-610-7500) AND CIA DISPATCH OFFICE (703-482-4368) ON DAY OF INSPECTION. STRUCTURE IS USED FOR
ACCESS/EGRESS TO CIA ENTRANCE GATE. DO NOT PHOTOGRAPH THE GATE OR VEHICLES.
(330) ADDITIONAL CONFIG. INFO.:
APPENDIX STRUCTURE NO. 3300-003P
PHOTOGRAPHS STRUCTURE NO. 3300-003P
PHOTO #1 - LOOKING EAST TOWARD POTOMAC RIVER
PHOTO #2 - NORTH SIDE
PHOTO #3 - GENERAL TOP SIDE VIEW LOOKING WEST
PHOTO #4 - GENERAL UNDERSIDE VIEW OF CENTER SPAN LOOKING
WEST
PHOTO #5 - VEGETATION GROWTH OBSCURING WEST APPROACH OF
BRIDGE FOR EASTBOUND ROADWAY REMOVED SINCE PREVIOUS
INSPECTION
PHOTO #6 - DETERIORATION OF SOUTH SIDEWALK AT EAST SPAN
PHOTO #7 - NEW EXPANSION JOINT OVER
EAST PIER INSTALLED SINCE PREVIOUS
INSPECTION
PHOTO #8 - TYPICAL SHORT RAIL POST
ANCHOR BOLTS, EAST END OF NORTH
RAILING SHOWN
PHOTO #9 - TYPICAL TRANSVERSE AND
DIAGONAL CRACKING OF DECK SURFACE,
CENTER SPAN SHOWN
PHOTO #10 - TYPICAL DETERIORATION OF
SILICONE SEALANT IN SIDEWALK EXPANSION
JOINTS, NORTH SIDEWALK OVER WEST
ABUTMENT SHOWN
PHOTO #11 - GENERAL VIEW OF EAST ABUTMENT
PHOTO #12 - TYPICAL RUSTING AND SECTION LOSS OF BEARINGS
UNDER EXTERIOR BEAMS AT ABUTMENTS, BEAM #1 AT EAST
ABUTMENT SHOWN
PHOTO #13 - TYPICAL CONDITION OF
INTERIOR BEARINGS AT ABUTMENTS,
BEARING #9 AT EAST ABUTMENT SHOWN
PHOTO #14 - DETERIORATION OF BEARING
SEAT AREA AT SOUTH END OF EAST
ABUTMENT BREASTWALL
PHOTO #15 - TYPICAL TRANSVERSE
CRACKING OF DECK UNDERSIDE WITH
EFFLORESCENCE, BAY #1 OF EAST SPAN
SHOWN
PHOTO #16 - TYPICAL DETERIORATION OF
PIER CAPS, WEST FACE OF EAST PIER CAP
SHOWN
PHOTO #17 - TYPICAL DETERIORATION OF
PIER CAPS, UNDERSIDE OF EAST PIER CAP
BETWEEN SOUTH AND CENTER COLUMNS
SHOWN
PHOTO #18 - TYPICAL DETERIORATION OF
BEAM ENDS FOR EAST SPAN, BEAM #2 OVER
EAST PIER SHOWN; NOTE DETERIORATED
BEARING DEVICE AND EXPOSED
PRESTRESSING STRANDS
PHOTO #19 - TYPICAL RUSTING AND SECTION LOSS OF BEARINGS,
BEAM #2 OVER EAST PIER SHOWN
PHOTO #20 - TYPICAL DETERIORATION OF END SPAN BEAM ENDS AT
PIERS, BEAM #4 FOR EAST SPAN SHOWN
PHOTO #21 - TYPICAL DETERIORATION OF END SPAN DIAPHRAGMS,
BAY #3 OVER EAST PIER SHOWN
PHOTO #22 - TYPICAL DETERIORATION OF END SPAN DIAPHRAGMS,
BAY #8 OVER EAST PIER SHOWN
PHOTO #23 - DETERIORATION OF CENTER
SPAN BEAMS #2 AND #3 OVER EAST PIER
PHOTO #24 - DETERIORATION OF CENTER
SPAN BEAM #2 OVER EAST PIER; NOTE
EXPOSED REBAR
PHOTO #25 - DETERIORATION OF CENTER
SPAN BEAM OVER EAST PIER; NOTE EXPOSED
REBAR
PHOTO #26 - SPALLING WITH EXPOSED
REBAR IN TOP FLANGE OF BEAM #2, CENTER
SPAN OVER SOUTHBOUND LANES; NOTE
DELAMINATION OVER SOUTHBOUND LANE OF
UNDERPASS ROADWAY
PHOTO #27 - SPALLING WITH EXPOSED REBAR AND PRESTRESSING
STRANDS IN BOTTOM FLANGES OF BEAMS #2 AND #3, CENTER SPAN
OVER NORTHBOUND LANE SHOWN
PHOTO #28 - SPALLING WITH EXPOSED REBAR AND PRESTRESSING
STRANDS OF BEAM #3 IN CENTER SPAN OVER NORTHBOUND LANE OF
UNDERPASS ROADWAY
PHOTO #29 - DELAMINATED AREA ON UNDERSIDE OF BEAM #2,
CENTER SPAN OVER SOUTHBOUND LANE OF UNDERPASS ROADWAY
PHOTO #30 - GENERAL VIEW OF WEST PIER, EAST FACE; NOTE
SPALLING WITH EXPOSED REBAR
PHOTO #31 - MISSING MORTAR BETWEEN GRANITE CAP AND TOP OF
SOUTHEAST WINGWALL