Drawing Roof (DraftBASEA001(I)_HOU.pdf).pdf
PDF 56 KB Posted
- Attached to
- HOU ARSR HVAC & Roof Replacement Federal contract opportunity
- Solicitation number
- 697DCK-22-R-00293
About this file
This document contains a federal solicitation and related roof replacement project drawings. The solicitation is seeking bids to remove and dispose of the existing roof, two HVAC units, associated ductwork, and a furnace/condensing unit from a facility. Bidders will provide and install a new roof, two 15-ton packaged HVAC units, two mini-split systems, HVAC controls, and all associated components. The project is set aside for small businesses with an estimated cost between $450,000 to $550,000. The period of performance is approximately 180 calendar days. An optional site visit will be held on July 7, 2022 at 9:00am at the project location. The solicitation number is 697DCK-22-R-00293 and is issued by the Department of Transportation Federal Aviation Administration Southwestern Region.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Roof Samples Ellington ARSR.pdf | ||
| 697DCK-22-R-00293 HOU ARSR HVAC and Roof Replacement.pdf | ||
| SUMMARY OF WORK_HOU ARSR HVAC and Roof Replacement.pdf | ||
| Drawing HVAC (DraftBASEM001(I)_HOU.pdf).pdf | ||
| Wage Determination TX20220253.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ENGINE GENERATOR ROOM
SCALE: NOT TO SCALE
ROOF PLAN
A001
MAIN BUILDING
WATER CLOSET
SHOWER/
KEYED NOTES:
ROOF SECTION IS AS FOLLOWS: (RVALUE = 25)
EXTERIOR, FIRE RATED GYPSUM BOARD
METAL FASTENERS FOR REQUIRED WIND RATING IN LOCAL AREA
PVC 80 MIL
EXTERIOR, FIRE RATED GYPSUM BOARD
1/2" DENS DECK
PVC 80 MIL
VAPOR BARRIER
STEEL DECK (20 GAGE)
RIGID INSULATION TO ACHIEVE DESIRED R-VALUE
EXISTING SUBSTRATE
ROOF SECTION IS AS FOLLOWS:
INSULATION COVER BOARD
ASSEMBLY SHALL MEET REQUIREMENTS FOR WIND RATING IN LOCAL AREA
CANOPY
CANOPY
GUTTER
GENERAL NOTES:
SIMILAR TO EXISTING; GUTTERS SHALL BE SEAMLESS
4) REPLACE ALL GUTTERS, DOWNSPOUTS, AND SPLASHBLOCKS WITH MATERIAL
PREP AND PAINT TO MATCH EXISTING COLOR
3) REPLACE ALL FASCIA AND SOFFIT WITH MATERIAL SIMILAR TO EXISTING;
LIGHTNING PROTECTION SHALL BE REINSTALLED IN ITS EXISTING LOCATION
PREVIOUSLY PROTECTED HVAC UNITS MOUNTED ON ROOF; ALL OTHER
2) REMOVE UNNECESSARY PORTIONS OF LIGHTNING PROTECTION THAT
MATCH EXISTING MATERIAL (20 GAUGE "Q" DECK, TYPE 3)
1) WELD STEEL PATCHES IN PLACE TO COVER EXISTING HVAC PENETRATIONS;
F
IL
E
S
D
A T
E
T
IM
E
N
A M
E
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
A001(I)
EXPANSION JOINT
EXPANSION JOINT
SEE NOTE 1
STEEL DECK PATCH (TYP);
GUTTER
GUTTER
ROOF INSTALLATION DRAWING
HOU ARSR: ROOF AND HVAC REPLACEMENT PROJECT
File details come from the government source that posted it. Updated .