Drawing.pdf

PDF 6 MB Posted

Attached to
REPLACE GENERATOR Federal contract opportunity
Solicitation number
140P6423Q0001
Issued by
Department of the Interior National Park Service Midwest Region

View the file

Other files for this federal contract opportunity

Other files attached to REPLACE GENERATOR, newest first.
File Type Posted
Specifications_-_Updated_0002.pdf PDF
26_24_13_Switchboard_Pictures_0002.pdf PDF
Sol_140P6423Q0001_Amd_0002.pdf PDF
Sol_140P6423Q0001_Amd_0001.pdf PDF
Specifications.pdf PDF
Past_Performance_Questionnaire.doc DOC document
Sol_140P6423Q0001.pdf PDF
Construction_Contract_Administration.docx DOCX document
Technical_Questionnaire.docx DOCX document
Construction_Wage_Determination.pdf PDF
Price_Schedule.xlsx XLSX spreadsheet
Price_Schedule.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HEADQUARTERS COMPLEX

REPLACE GENERATOR

INDIANA DUNES NATIONAL PARK

VICINITY MAP REGIONAL MAP

LOCATION MAP

INDIANA DUNES NATIONALPARK1100 NORTH MINERAL SPRINGS ROAD

PORTER, IN 46304

80051

G A

S G

A S

DEMOLITION KEY NOTES:

1. REMOVE EXISTING DUCTWORK BETWEEN GENERATOR

AND LOUVER.

2. DISCONNECT AND REMOVE EXISTING GENERATOR, AND

GENERATOR EXHAUSTER.

3. SHUT GAS VALVE AND REMOVE GAS PIPING BETWEEN

VALVE AND GENERATOR.

4. DISCONNECT AND REMOVE THE ONAN 12.5 GENSET

GENERATOR, AND GENERATOR EXHAUSTER. DISABLE

TRANSFER SWITCH.

5. DISCONNECT AND REMOVE TRANSFER SWITCH.

6. DISCONNECT AND REMOVE GENERAL DUTY 600 AMP

240-VOLT 3-POLE INDOOR FUSIBLE SAFETY SWITCH.

7. EXISTING FANS TO REMAIN.

x

DEMOLITION GENERAL NOTES:

1. THE OWNER SHALL HAVE THE FIRST RIGHT OF SALVAGE

FOR ALL MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS

BEING REMOVED OR DEMOLISHED. IF OWNER DECLINES,

THE CONTRACTOR SHALL REMOVE FROM THE PREMISES

AND DISPOSE OF PROPERLY. VERIFY OWNER'S INTENT

PRIOR TO REMOVAL OR DEMOLITION.

2. REMOVE ALL DUCTWORK, PIPING, AND EQUIPMENT SHOWN

DASHED. INFORMATION PERTAINING TO THE EXISTING

BUILDING HAS BEEN OBTAINED THROUGH THE BUILDINGS

ORIGINAL DRAWINGS WHERE AVAILABLE. REPORT

DISCREPANCIES TO THE ARCHITECT AND ENGINEER PRIOR

TO ANY DEMOLITION. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING CONDITIONS PRIOR TO COMMENCING

WORK.COORDINATE SHUTDOWN OF ALL UTILITIES FOR

DEMOLITION WORK WITH THE OWNER. DISCONNECT,

DEMOLISH, AND REMOVE MECHANICAL SYSTEMS,

EQUIPMENT, AND COMPONENTS INDICATED AS HATCHED

TO BE REMOVED.

3.

PIPING TO BE REMOVED: REMOVE PORTION OF PIPING

INDICATED TO BE REMOVED AND CAP OR PLUG REMAINING

PIPING WITH THE SAME OR COMPATIBLE PIPING MATERIAL.

4. PIPING TO BE ABANDONED IN PLACE: DRAIN PIPING AND

CAP OR PLUG PIPING WITH THE SAME OR COMPATIBLE

PIPING MATERIAL.

5. DUCTS TO BE REMOVED: REMOVE PORTIONS OF DUCT

AND PLUG REMAINING DUCTS WITH THE SAME OR

COMPATIBLE DUCTWORK MATERIAL.

6. DUCTS TO BE REMOVED AND REPLACED: REPLACEMENT

DUCTS WITH THE SAME OR COMPATIBLE DUCTWORK

MATERIAL.

7. EQUIPMENT TO BE REMOVED: DISCONNECT AND CAP

SERVICES AND REMOVE EQUIPMENT.

8. EQUIPMENT TO BE REMOVED AND REINSTALLED:

DISCONNECT AND CAP SERVICES AND REMOVE, CLEAN,

AND STORE EQUIPMENT. WHEN APPROPRIATE, REINSTALL,

RECONNECT, AND MAKE EQUIPMENT FULLY OPERATIONAL.

9. EQUIPMENT TO BE REMOVED AND SALVAGED:

DISCONNECT AND CAP SERVICES AND REMOVE

EQUIPMENT AND DELIVER TO OWNER.

10. IT IS HIGHLY RECOMMENDED CONTRACTOR VISIT SITE AND

FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO

BIDDING PROJECT.

11. COORDINATE DEMOLITION WITH THE WORK OF OTHER

TRADES. PROVIDE TEMPORARY UTILITIES AS REQUIRED

TO ALLOW THE WORK OF OTHER TRADES TO PROCEED.

12. REMOVE EXISTING SHED INCLUDING WALLS, ROOF, SLAB,

AND ELECTRICAL PANELS. INSTALL A NEW TRANSFER

SWITCH AND ELECTRICAL CONDUITS FOR AN OUTDOOR

GENERATOR UNIT.

INDIANA DUNES NATIONALPARK1100 NORTH MINERAL SPRINGS ROAD

PORTER, IN 46304

80051

X

HVAC KEY NOTES:

1. INSTALL NEW GENERATOR WITH HEAVY DUTY SAFETY

SWITCH, AND CONNECT POWER TO IT.

2. CONNECT THE GAS FROM THE EXISTING GAS VALVE TO

THE GENERATOR. GAS PIPING SIZE SHALL MATCH THE

EXISTING AND HAVE A FLEXIBLE CONNECTION.

3. INSTALL NEW TRANSFER SWITCH AND CONNECT TO

GENERATOR.

4. INSTALL NEW 6-IN THICK CONCRETE EQUIPMENT PAD.

SIZE OF PAD TO OFFSET 1-FOOT FROM ALL SIDES OF

GENERATOR HOUSING, OR MATCH MANUFACTURER'S

RECOMMENDED SIZE OF EQUIPMENT PAD, WHICH EVER IS

LARGER.

G A

S G

A S

GAS

TRANSFER

SWITCH

GENERATOR

INDIANA DUNES NATIONALPARK1100 NORTH MINERAL SPRINGS ROAD

PORTER, IN 46304

80051

LATEST NATIONAL ELECTRICAL CODE

CONNECT GENERATOR TO EXISTING NATURAL GAS LINE TO MEET

MANUFACTURER AND NORTHERN INDIANA PUBLIC SERVICE COMPANY'S

(NIPSCO) REQUIREMENTS AND RECOMMENDATIONS.

Sheets and Views
COVER-COVER SHEET
help
E1.pdf
Sheets and Views
MEP-E1
ED1.pdf
Sheets and Views
MEP-ED1
G1.pdf
Sheets and Views
MEP-G1

File details come from the government source that posted it. Updated .