Data Requirements 4019.pdf
PDF 346 KB Posted
- Attached to
- CAPSCREWS Federal contract opportunity
- Solicitation number
- SPMYM324Q4019
About this file
This document contains four Contract Data Requirements Lists related to federal contracts for socket head cap screws and socket flat countersunk head cap screws. The contracts require the contractor to submit Certificate of Compliance data items and Certification Data/Report data items certifying quality compliance, chemical and mechanical test results as specified in the Defense Logistics Agency contracts. Deliverables include certificates and certifications to be provided with material shipments and are to meet standards like DI-MISC-81356A and DI-MISC-80678. Procedures for payment and data submission are also outlined. The contracts specify deliverables, standards, and quality compliance requirements for socket head cap screws and socket flat countersunk head cap screws to be provided to the Defense Logistics Agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Solicitation Capscrews SPMYM324Q4019.docx | DOCX document | |
| FAR-DLAD-Local Notes and Clauses 4019.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT DATA REQUIREMENTS LIST
245.2C-0419-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD SLF
LKG CAP SCREW ANGLE
E. CONTRACT/PR NO.
33534011-3
F. CONTRACTOR
1. DATA ITEM NO.
A001
2. TITLE of DATA ITEM
CERTIFICATE OF COMPLIANCE
3. SUBTITLE
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DI-MISC-81356A
5. CONTRACT REFERENCE
SECTION C. 2
6. REQUIRING OFFICE
CODE 245
7. DD 250 REQ
DD
9. DIST
STATEMENT
REQUIRED
A
10. FREQUENCY
One Time
12. DATE OF 1st
SUBMISSION
With Material
14. DISTRIBUTION
a.
ADDR
ESSE
E
b. COPIES
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Technical content as described in the respective contract line item(s).
2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
0 0 0
15.
TOTA
L
0 1 0
1.DATA ITEM NO.
A002
2 TITLE of DATA ITEM
CERTIFICATION DATA / REPORT
NDT, CHEMICAL & MECHANICAL
CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
SECTION C. 3
DD
9. DIST
a.
ADDR
ESSE
E
b. COPIES
DRAFT FINAL
8. APP. CODE
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all the NDT requested, also include all Chemical & Mechanical Test results required by the Specification.
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification
15.
TOTA
L
0 1 0
DD FORM 1423 PAGE 1 OF 2
245.2C-0419-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
SLF LKG CAP SCREW ANGLE
E. CONTRACT/PR NO.
33534011-3
F. CONTRACTOR
1. DATA ITEM
NO.
A003
2. TITLE of DATA ITEM
PROCEDURES, TEST
3. SUBTITLE
NDT (PT) PROCEDURE APPROVAL
4. AUTHORITY(DATA Item Description Number)
UDI-T-23732-B
SECTION C. 4
PURCHASING ACTIVITY
LT
9. DIST
PRIOR TO ANY PT
PERFORMED
a. ADDRESSEE b. COPIES
DRAFT
FINAL
8. APP. CODE
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
135T 0 1 0
16 REMARKS
Block 4- Paragraph 10.1 of UDI-T-23732 B does not apply.
Non-Destructive Liquid Penetrant Inspection (PT) Procedure Performance: NAVSEA T9074-AS-GIB-010/271 Rev 1 and FF-S-86H Acceptance: DWG 150-8217366 REV XA NOTE 7003 and SAE AMS J123
For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.
15. TOTAL 0 1 0
1. DATA ITEM NO.
A004
CERTIFICATION/DATA REPORT
TEST CERTIFICATION LIQUID PENETRANT
INSPECTION
4. AUTHORITY
DI-MISC-80678(DD)
5. CONTRACT REFERENCE
SECTION C. 5
PURCHASING ACTIVITY
SD
9. DIST
WITH MATERIAL
DRAFT FINAL
8. APP. CODE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
Block 4 Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 of DI-MISC-80678(DD) do not apply. ___
G. PREPARED BY
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
01/03/2024
I. APPROVED BY 245.2
X
J. DATE
01/20/2024
DD FORM 1423 PAGE 2 OF 2
245.2C-0458-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET HEAD CAP SCREW & SOCKET
FLAT COUNTERSUNK HEAD CAP SCREW
ANGLE
E. CONTRACT/PR NO.
40024001-3
F. CONTRACTOR
1. DATA ITEM NO.
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DD
9. DIST
DRAFT FINAL
8. APP. CODE
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
1.DATA ITEM NO.
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
DD
9. DIST
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
CONRAD GAGNE Ext: 3617 245.2C
H. DATE
01/02/2024
245.2C-0465-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
CAP SCREW ANGLE
E. CONTRACT/PR NO.
40034031-4
F. CONTRACTOR
1. DATA ITEM NO.
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DD
9. DIST
DRAFT FINAL
8. APP. CODE
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
1.DATA ITEM NO.
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
DD
9. DIST
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
01/03/2024
245.2C-0469-24 (2 DATA ITEMS)
A. CONTRACT LINE ITEM NO. B. EXHIBIT
A
C. CATEGORY
TDP X TM ______ OTHER______
D. SYSTEM/ITEM
SOCKET FLAT COUNTERSUNK HEAD
SLF LKG CAP SCREW ANGLE
E. CONTRACT/PR NO.
40044001-4
F. CONTRACTOR
1. DATA ITEM NO.
CERTIFICATION OF QUALITY
COMPLIANCE
4. AUTHORITY(DATA Item Description Number)
DD
9. DIST
DRAFT FINAL
8. APP. CODE
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
1.DATA ITEM NO.
CHEMICAL & MECHANICAL CERTIFICATION
4. AUTHORITY
DI-MISC-80678
5. CONTRACT REFERENCE
DD
9. DIST
DRAFT FINAL
8. APP. CODE
N/A
11. AS OF DATE
N/A
13. DATE OF
SUBSEQUENT
SUBMISSION
N/A
REG REPRO
133.2 0 1 0
16 REMARKS
1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.
2. Technical content as described in the respective contract line item(s).
3. This certification shall contain the actual Test results of all Chemical &
Mechanical Test required by the Specification
4. The Test results shall be quantitative & in the units required by the specification.
5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-
7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.
6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.
G. PREPARED BY
01/04/2024
| 1 |
| 2 |
| 3 |
| 4 |