Data Requirements 4019.pdf

PDF 346 KB Posted

Attached to
CAPSCREWS Federal contract opportunity
Solicitation number
SPMYM324Q4019
Issued by
Defense Logistics Agency Land and Maritime

About this file

This document contains four Contract Data Requirements Lists related to federal contracts for socket head cap screws and socket flat countersunk head cap screws. The contracts require the contractor to submit Certificate of Compliance data items and Certification Data/Report data items certifying quality compliance, chemical and mechanical test results as specified in the Defense Logistics Agency contracts. Deliverables include certificates and certifications to be provided with material shipments and are to meet standards like DI-MISC-81356A and DI-MISC-80678. Procedures for payment and data submission are also outlined. The contracts specify deliverables, standards, and quality compliance requirements for socket head cap screws and socket flat countersunk head cap screws to be provided to the Defense Logistics Agency.

View the file

Other files for this federal contract opportunity

Other files attached to CAPSCREWS, newest first.
File Type Posted
Combined Synopsis Solicitation Capscrews SPMYM324Q4019.docx DOCX document
FAR-DLAD-Local Notes and Clauses 4019.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT DATA REQUIREMENTS LIST

245.2C-0419-24 (2 DATA ITEMS)

A. CONTRACT LINE ITEM NO. B. EXHIBIT

A

C. CATEGORY

TDP X TM ______ OTHER______

D. SYSTEM/ITEM

SOCKET FLAT COUNTERSUNK HEAD SLF

LKG CAP SCREW ANGLE

E. CONTRACT/PR NO.

33534011-3

F. CONTRACTOR

1. DATA ITEM NO.

A001

2. TITLE of DATA ITEM

CERTIFICATE OF COMPLIANCE

3. SUBTITLE

CERTIFICATION OF QUALITY

COMPLIANCE

4. AUTHORITY(DATA Item Description Number)

DI-MISC-81356A

5. CONTRACT REFERENCE

SECTION C. 2

6. REQUIRING OFFICE

CODE 245

7. DD 250 REQ

DD

9. DIST

STATEMENT

REQUIRED

A

10. FREQUENCY

One Time

12. DATE OF 1st

SUBMISSION

With Material

14. DISTRIBUTION

a.

ADDR

ESSE

E

b. COPIES

DRAFT FINAL

8. APP. CODE

N/A

11. AS OF DATE

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

16 REMARKS

1. Technical content as described in the respective contract line item(s).

2. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-

7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.

0 0 0

15.

TOTA

L

0 1 0

1.DATA ITEM NO.

A002

2 TITLE of DATA ITEM

CERTIFICATION DATA / REPORT

NDT, CHEMICAL & MECHANICAL

CERTIFICATION

4. AUTHORITY

DI-MISC-80678

5. CONTRACT REFERENCE

SECTION C. 3

DD

9. DIST

a.

ADDR

ESSE

E

b. COPIES

DRAFT FINAL

8. APP. CODE

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

16 REMARKS

1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.

2. Technical content as described in the respective contract line item(s).

3. This certification shall contain the actual Test results of all the NDT requested, also include all Chemical & Mechanical Test results required by the Specification.

4. The Test results shall be quantitative & in the units required by the specification.

5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232- 7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.

6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.

7. In addition to the Certification Data requirements specified in DI-MISC-80678, the requirements of the contract section titled, Marking and Certification

15.

TOTA

L

0 1 0

DD FORM 1423 PAGE 1 OF 2

245.2C-0419-24 (2 DATA ITEMS)

A. CONTRACT LINE ITEM NO. B. EXHIBIT

A

C. CATEGORY

TDP X TM ______ OTHER______

D. SYSTEM/ITEM

SOCKET FLAT COUNTERSUNK HEAD

SLF LKG CAP SCREW ANGLE

E. CONTRACT/PR NO.

33534011-3

F. CONTRACTOR

1. DATA ITEM

NO.

A003

2. TITLE of DATA ITEM

PROCEDURES, TEST

3. SUBTITLE

NDT (PT) PROCEDURE APPROVAL

4. AUTHORITY(DATA Item Description Number)

UDI-T-23732-B

SECTION C. 4

PURCHASING ACTIVITY

LT

9. DIST

PRIOR TO ANY PT

PERFORMED

a. ADDRESSEE b. COPIES

DRAFT

FINAL

8. APP. CODE

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

135T 0 1 0

16 REMARKS

Block 4- Paragraph 10.1 of UDI-T-23732 B does not apply.

Non-Destructive Liquid Penetrant Inspection (PT) Procedure Performance: NAVSEA T9074-AS-GIB-010/271 Rev 1 and FF-S-86H Acceptance: DWG 150-8217366 REV XA NOTE 7003 and SAE AMS J123

For Payment & submission of Data refer to clauses 252.232-7006, 252.232-7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number. No material is to be shipped prior to the receipt of acceptance.

15. TOTAL 0 1 0

1. DATA ITEM NO.

A004

CERTIFICATION/DATA REPORT

TEST CERTIFICATION LIQUID PENETRANT

INSPECTION

4. AUTHORITY

DI-MISC-80678(DD)

5. CONTRACT REFERENCE

SECTION C. 5

PURCHASING ACTIVITY

SD

9. DIST

WITH MATERIAL

DRAFT FINAL

8. APP. CODE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

Block 4 Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 of DI-MISC-80678(DD) do not apply. ___

G. PREPARED BY

CONRAD GAGNE Ext: 3617 245.2C

H. DATE

01/03/2024

I. APPROVED BY 245.2

X

J. DATE

01/20/2024

DD FORM 1423 PAGE 2 OF 2

245.2C-0458-24 (2 DATA ITEMS)

A. CONTRACT LINE ITEM NO. B. EXHIBIT

A

C. CATEGORY

TDP X TM ______ OTHER______

D. SYSTEM/ITEM

SOCKET HEAD CAP SCREW & SOCKET

FLAT COUNTERSUNK HEAD CAP SCREW

ANGLE

E. CONTRACT/PR NO.

40024001-3

F. CONTRACTOR

1. DATA ITEM NO.

CERTIFICATION OF QUALITY

COMPLIANCE

4. AUTHORITY(DATA Item Description Number)

DD

9. DIST

DRAFT FINAL

8. APP. CODE

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

1.DATA ITEM NO.

CHEMICAL & MECHANICAL CERTIFICATION

4. AUTHORITY

DI-MISC-80678

5. CONTRACT REFERENCE

DD

9. DIST

DRAFT FINAL

8. APP. CODE

N/A

11. AS OF DATE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

16 REMARKS

1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.

2. Technical content as described in the respective contract line item(s).

3. This certification shall contain the actual Test results of all Chemical &

Mechanical Test required by the Specification

4. The Test results shall be quantitative & in the units required by the specification.

5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-

7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.

6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.

CONRAD GAGNE Ext: 3617 245.2C

H. DATE

01/02/2024

245.2C-0465-24 (2 DATA ITEMS)

A. CONTRACT LINE ITEM NO. B. EXHIBIT

A

C. CATEGORY

TDP X TM ______ OTHER______

D. SYSTEM/ITEM

SOCKET FLAT COUNTERSUNK HEAD

CAP SCREW ANGLE

E. CONTRACT/PR NO.

40034031-4

F. CONTRACTOR

1. DATA ITEM NO.

CERTIFICATION OF QUALITY

COMPLIANCE

4. AUTHORITY(DATA Item Description Number)

DD

9. DIST

DRAFT FINAL

8. APP. CODE

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

1.DATA ITEM NO.

CHEMICAL & MECHANICAL CERTIFICATION

4. AUTHORITY

DI-MISC-80678

5. CONTRACT REFERENCE

DD

9. DIST

DRAFT FINAL

8. APP. CODE

N/A

11. AS OF DATE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

16 REMARKS

1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.

2. Technical content as described in the respective contract line item(s).

3. This certification shall contain the actual Test results of all Chemical &

Mechanical Test required by the Specification

4. The Test results shall be quantitative & in the units required by the specification.

5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-

7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.

6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.

01/03/2024

245.2C-0469-24 (2 DATA ITEMS)

A. CONTRACT LINE ITEM NO. B. EXHIBIT

A

C. CATEGORY

TDP X TM ______ OTHER______

D. SYSTEM/ITEM

SOCKET FLAT COUNTERSUNK HEAD

SLF LKG CAP SCREW ANGLE

E. CONTRACT/PR NO.

40044001-4

F. CONTRACTOR

1. DATA ITEM NO.

CERTIFICATION OF QUALITY

COMPLIANCE

4. AUTHORITY(DATA Item Description Number)

DD

9. DIST

DRAFT FINAL

8. APP. CODE

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

1.DATA ITEM NO.

CHEMICAL & MECHANICAL CERTIFICATION

4. AUTHORITY

DI-MISC-80678

5. CONTRACT REFERENCE

DD

9. DIST

DRAFT FINAL

8. APP. CODE

N/A

11. AS OF DATE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

133.2 0 1 0

16 REMARKS

1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.

2. Technical content as described in the respective contract line item(s).

3. This certification shall contain the actual Test results of all Chemical &

Mechanical Test required by the Specification

4. The Test results shall be quantitative & in the units required by the specification.

5. For Payment & Submission of Data refer to Clauses 252.232-7006 & 252.232-

7003 or 52.232-36. Each Data Item Submitted by Vendor must be Submitted under a Separate Shipment Number.

6. Fastener certification shall show evidence of testing of the correct number of specimens, new untested fasteners are required for each test where wedge tensile testing and yield strength testing are required.

G. PREPARED BY

01/04/2024

1
2
3
4

File details come from the government source that posted it. Updated .