Text version

SALIENT CHARACTERISTICS FOR

EFD INDUCTION SYSTEM

JML’S 3040-3925, 3926 & 3927

2/09/2023

MAIN POWER UNIT OUTPUT

o Continuous power output=50kW o Maximum output power= 80kW o Duty factor/Cycle time=50%/10min o Output power regulation range=2-100% o Frequency Range=10-25kHz o HHT 400 power cable length=5M/10M o NRTL completed on main cabinet.

MAIN POWER UNIT SUPPLY

o Supply voltage range=3 x 400-480 +or-10% o Frequency=50/60Hz o Nominal voltage=400 V o Nominal line current=89A (RMS) o Max line current intermittent=134A (RMS) o Nominal apparent power=62kVA o Maximum apparent power=93kVA o Recommended fuse=100 Amp o Mains cable length=5M

COOLING

o Water consumption, min=21l/min o Water inlet temperature=Max 35 degrees Celsius o Water Pressure min/max=4.5-6 bar o Cooling water quality PH=Between 7.0-9.0

ENCLOSURE

o Ambient operating temp=+5 degrees Celsius to +50 degrees Celsius o Outer dimensions (W x D x H)=345 x 708 x 453 mm o Weight with HHT 400/5M=80 kg (Approximately) o Enclosure protection=IP 54 o Color=RAL 7021 Black o HHT 400 outer dimension (L x OD)=183 x 77 mm o HHT 400 weight without handle=6kg

Transformer o Hand transformer with 10 meter long output cable

LINEAR/MANUAL SCANNING COILS

o Must heat and 8” wide band in a manual scanning condition o Copper tube construction o Miter joints silver brazed o Electrical contacts are silver-plated